0% found this document useful (0 votes)
11 views6 pages

University of Engineering and Technology Abbottabad University of Engineering and Technology Abbottabad (Satellite Campus)

Uploaded by

Asjad Naseer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
11 views6 pages

University of Engineering and Technology Abbottabad University of Engineering and Technology Abbottabad (Satellite Campus)

Uploaded by

Asjad Naseer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 6

LAB REPORT ELACTRICAL MACHINE PERFOREMED BY ABDULLAH, MUJAHID, AHSAN AND MEHTAB

University of Engineering and Technology Abbottabad


University of Engineering and Technology Abbottabad
(Satellite Campus)
Faculty of Department of Electronics Engineering
Electrical Machine
5th Semester 2021
Group No 02

Group Members Name Mehtab Khan


Mujahid Bilal
Abdullah Jan
Ahsan Jamil Awan
Roll No 5,8,15,23

Registration No 19Abelt0829
19Abelt0831
19Abelt0838
19Abelt0845
Lab No 05
Date 24-12-2021
Report Verification:

Instructor Name: Eng. Wajid Mehmood


Signature:

Group#02
LAB REPORT ELACTRICAL MACHINE PERFOREMED BY ABDULLAH, MUJAHID, AHSAN AND MEHTAB

EXPERIMENT NO.6
Voltage regulation of synchronous generator

OBJECTIVE:
 The basic purpose of this experiment is to find percentage difference of voltage
regulation of synchronous generator

APPARATUS:
 DC shunt generator.
 R.P.M Meter.
 Power supply for DC shunt generator field (F1,F2).
 DC drive for Prime mover.
 Volt meters.
 Ammeters.
 Load.
 Connecting leads.

Procedure
 Generator is connected in star or Y connection.

 Set the manual excitation and adjust speed control of prime mover to zero.

 Start the prime mover and adjust the speed to nominal 3000 rev-min.

 Keep a constant excitation current Iƒ of 1Ã̃and vary the speed in increment of 50rev-min to
a maximum of 3500rev-min. at each increment, record the out-put terminal voltage and
speed in table 6-1.

 Repeat for constant excitation current 0-5A and 1.5A

Relations

 VαN

 Vαϕ

 ϕα Iƒ

 Vα Iƒ

Group#02
LAB REPORT ELACTRICAL MACHINE PERFOREMED BY ABDULLAH, MUJAHID, AHSAN AND MEHTAB

Circuit Diagram:

Hardware Circuit Diagram:

At No Load:

Group#02
LAB REPORT ELACTRICAL MACHINE PERFOREMED BY ABDULLAH, MUJAHID, AHSAN AND MEHTAB

At Full Load:

Voltage regulation on full load:

Voltage Full-
load
voltage

6.3V 87V

10V 116.5 V

15.5V 156.2 V

19.19V 169.1 V

Group#02
LAB REPORT ELACTRICAL MACHINE PERFOREMED BY ABDULLAH, MUJAHID, AHSAN AND MEHTAB

Voltage regulation on no load


VOLTAGE NO LOAD
VOLTAGE

6.3V 86.2V

9.94 V 148.9 V

14.95V 187.2 V

19.19V 204.2 V

Percentage difference of voltage regulation on full load and no load

Change∈Output voltage
Regulation=
no load output voltage
Voltage no load−voltage full load
Regulation=
voltage no load

Percentage voltage regulations

Voltage Full-load No load Percent voltage regulation=


voltage
Voltage no load−voltage full load
voltage no load
6.3V 87V 86.2V 0.92%

10V 116.5 V 128.9 V 9.6%

15.5V 176.2 V 187.2 V 5.6%

19.19V 193.1 V 204.2 V 5.44%

Group#02
LAB REPORT ELACTRICAL MACHINE PERFOREMED BY ABDULLAH, MUJAHID, AHSAN AND MEHTAB

Group#02

You might also like