M6.1. Static-Lateral-Procedure5-Storey
M6.1. Static-Lateral-Procedure5-Storey
Column : W310x179
Occupancy : Residential
Location : Carig, Tuguegarao City
I= 1.0 , Standard Occupancy Structure (Residential)
Special Moment Resisting Frame (SMRF)
Page 6
Near Source Factors
Na = 1.0
Nv = 1.0
Page 7
Near Source Factors
Page 8
Ca = 0.44
Cv = 0.64
Zone 4
Z= 0.4
Lateral Resistance Factor
R= 8
Page 11
Lateral Resistance Factor
Page 12
Design Base Shear using the Static Lateral Procedure
CvI
V= W 0.64(1)W
RT = = 0.1135 W (208-8)
8(0.7047)
0. 8ZNvI 0.8(0.4)(1.0)(1.0)W
V= W = = 0.0400 W (208-11)
R 8
Use V = 535.85 KN
Vertical Distribution of Design Base Shear(V) V= 535.85
Level W(KN) h(m) Wh (KN-m) Wh/ΣWh Ft(KN) (V-Ft)(Wh/ΣWh) Fx (KN)
ROOF 890 16.7 14863 0.3157 26.43 160.83 187.26
5F 950 13.4 12730 0.2704 0 137.75 137.75
4F 950 10.1 9595 0.2038 0 103.83 103.83
3F 950 6.8 6460 0.1372 0 69.90 69.90
2F 980 3.5 3430 0.0729 0 37.12 37.12
GROUND - 0 - - - -
Σ 4720 47078 1.0 Σ 535.85
187.26 KN
137.75 KN
103.83 KN
69.902 KN
37.12 KN
KN
Horizontal Distribution
Assume a Rigid Diaphragm
Assume origin at A-1 Column
1.) Locate the Center of Mass (CM)
12 EI c
k= (β)
h3
Assumption : β = 1.0 (pure bending , rigid supports)
Ratio Stiffness (normalized)
Kx = 29,718.67 N/mm , Sx = 1.000
Ky = 9,616.83 N/mm , Sy = 0.324
Horizontal Distribution
CM + Accidental Eccentricity
CMy’ = 4.5 +0.45 = 4.95 m
ey = 4.95 – 4.40 = 0.55 m
M = V(ey) = 102.99 KN-m