Footplate inspection in PUNE-LNL Section by ADME/Op/Pune
on
Date 17/11/2024
Train No: 01578(EMU) Loco No: 2182C-2184-2183-218
Date:17/11/2024
Station From:- PUNE Station To:- LNL
A. Loco Inspection:-
(i) LPM/MM : Shri. F.G ATTAR ii) ALP: NA
(iii)TM: Shri. D.N. THAKUR
1 Safety fittings of Loco, i) Head light: WKG ii) Flasher light: WKG
LP’s tool iii) Classification light: iv) Looking glass: Visibility
Visibility Clear Clear
v) Buffer: Intact vi) Cattle guard: Intact
vii) Coupling: Intact viii) LP tool/kit: Avl
ix) Wiper: WKG x) VCD Counter/ISU No-355
2 LP’s personal All available
equipment: (Spect.,
Detonator, T/Torch, Bio-
Data, etc.)
3 Train Load 12 coach
4 BPC (MV-5) 2182-2184-2183-2181 100%, done date-15/11/24, due
date- 29/11/24, TSRT/Pune.
5 LP’s bio-data i) PME due: 07/03/2025
ii) GR & SR due: 26/07/2026
iii) DSL Refresher due: NA
iv) Safety Camp due: 26/07/2026
v)MEMU training overdue on 09/09/2024
6 Sig. Visibility/focusing Visibility clear
7 Calling out Sig. aspect Loudly
8 Placement of Placed at proper location
caution board/speed
board
/Termination board
9 LP observing SR or not SR followed strictly.
10 Whistling at Level crossing Whistling properly by MM
11 Exchange of Alright NA
signals
12 Looking back by LP/ALP NA
13 Bad riding NIL
14 T-369(3b)&(1) Available
15 T-409 Caution order Available
16 Kilo meter Posts Available
17 Auto signaling Available
18 Brake Power tested: Yes, BFT & BPT carried out properly by MM
19 Unauthorized person NO
in loco cabin
20 Knowledge of safety Satisfactory
rules of LP/ALP
21 Practical problem faced No
by LP
22 PCP set available or not NA
23 Walkie-talkie set with PA system
spare battery ‘Yes’ or
‘Not’
24 Working Time Table Available
B. Running particulars:-
STATION ARRIVAL DEPARTURE REMARKS
Pune -- 20:45
LNL 22:02 ---
C. Observation:-
S.N. Observation Action by
1 Four wooden wedges available
2 CCH stn. UP loop line load secured
3 CCH stn. Dn goods passing through and crew exchanged signal.
4 VDN stn. EMU halt board nearest to LP-30 Signal (need to shift
before suitable palace.)
5
PA/loco Op/ADME Op/Insp./2024 Date: 18.11.2024
Insp. Note No.2
( )
ADME Op Pune
C/-DRM/Pune, ADRM/Pune: For kind information please.
C/-Sr. DOM/Pune, Sr. DSTE/Pune, Sr. DSC/Pune, Sr. DME/C&W/Pune : For kind
information & necessary action.
C/-Sr. DSO/Pune: For kind information please.
C/-DME/Op/Pune: For information and necessary action.
C/-SSE Incharge/ELTS/Pune, CCCOR All Lobbies:- For information & necessary action
Footplate inspection in LNL- PUNE Section by ADME/Op/Pune
on
Date 17/11/2024
Train No: 01577(EMU) Loco No: 2182C-2184-2183-218
Date:17/11/2024
Station From:-LNL Station To:- PUNE
A.
Loco Inspection:-
(i) LPM/MM : Shri. F.G ATTAR ii) ALP: NA
(iii)TM: Shri. D.N. THAKUR
1 Safety fittings of Loco, i) Head light: WKG ii) Flasher light: WKG
LP’s tool iii) Classification light: iv) Looking glass: Visibility Clear
Visibility Clear
v) Buffer: Intact vi) Cattle guard: Intact
vii) Coupling: Intact viii) LP tool/kit: Available
ix) Wiper: WKG x) VCD Counter/ISU No.: 323
2 LP’s personal All available
equipment: (Spect.,
Detonator, T/Torch, Bio-
Data, etc.)
3 Train Load 12 coach
4 BPC (MV-5) 2182-2184-2183-2181 100% , done date-15/11/24,due
date 29/11/24, TSRT/Pune.
5 LP’s bio-data i) PME due: 07/03/2025
ii) GR & SR due: 26/07/2026
iii) DSL Refresher due: NA
iv) Safety Camp due: 26/07/2026
v)MEMU training overdue on 09/09/2024
6 Sig. Visibility/focusing Visibility clear
7 Calling out Sig. aspect Loudly
8 Placement of Placed at proper location
caution board/speed
board
/Termination board
9 LP observing SR or not SR followed strictly.
10 Whistling at Level crossing Whistling properly by MM
11 Exchange of Alright NA
signals
12 Looking back by LP/ALP NA
13 Bad riding NIL
14 T-369(3b)&(1) Available
15 T-409 Caution order Available
16 Kilo meter Posts Available
17 Auto signaling Available
18 Brake Power tested: Yes, BFT & BPT carried out properly by MM
19 Unauthorized person NO
in loco cabin
20 Knowledge of safety Satisfactory
rules of LP/ALP
21 Practical problem faced No
by LP
22 PCP set available or not NA
23 Walkie-talkie set with PA system
spare battery ‘Yes’ or
‘Not’
24 Working Time Table Available
B. Running particulars:-
STATION ARRIVAL DEPARTURE REMARKS
LNL -- 22:12
Pune 23:35 ---
C. Observation:-
S.N. Observation Action by
1 Four wooden wedges available
2 Trespassing at LC 34, (KMST-VDN)
3 At KSMT Stn down goods train stop and Tail lamp flickering
4 LNL-MVL W/L board faded, needs to refroreflective
5 CCH Stn. 2nd down loop NMG load stable
6 SLRW Stn KM NO. 163/02-06, 30 KMPH TSR same observed by
crew
7 DEHR Stn. 2nd loop goods load stable
8 DEHR Stn. 1st loop goods train stopped and Tail lamp flickering
9 No fog observed in section
PA/loco Op/ADME Op/Insp./2024 Date: 18.11.2024
Insp. Note No.
( )
ADME Op Pune
C/-DRM/Pune, ADRM/Pune: For kind information please.
C/-Sr. DOM/Pune, Sr. DSTE/Pune, Sr. DSC/Pune, Sr. DME/C&W/Pune : For kind
information & necessary action.
C/-Sr. DSO/Pune: For kind information please.
C/-Sr.DME/Op/Pune: For information and necessary action.
C/-SSE Incharge/ELTS/Pune, CCCOR All Lobbies:- For information and necessary action.