DM280_Quick_Reference
DM280_Quick_Reference
2024 October 01
Revision: 24.3.0.11
Precautions
To reduce the risk of injury or equipment damage, observe the following
precautions when you install the Cognex product:
l Connectivity is possible through the following options:
l 24 VDC (+/- 10%) output connection using a UL or NTRL listed
power supply
l Power over Ethernet (PoE) 13 W power supply
Any other voltage creates a risk of fire or shock and can damage the
components. Applicable national and local wiring standards and rules must
be followed.
l This product is intended for industrial use in automated manufacturing or
similar applications.
l The safety of any system incorporating this product is the responsibility of
the assembler of the system.
l Do not install Cognex products where they are exposed to environmental
hazards such as excessive heat, dust, moisture, humidity, impact,
vibration, corrosive substances, flammable substances, or static electricity.
l Route cables and wires away from high-current wiring or high-voltage
power sources to reduce the risk of damage or malfunction from the
following causes: over-voltage, line noise, electrostatic discharge (ESD),
power surges, or other irregularities in the power supply.
l Do not expose the image sensor to laser light. Image sensors can be
damaged by direct, or reflected, laser light. If your application requires
laser light that might strike the image sensor, use a lens filter at the
corresponding laser wavelength. For suggestions, contact your local
integrator or application engineer.
2
l This product does not contain user-serviceable parts. Do not make
electrical or mechanical modifications to product components.
Unauthorized modifications can void your warranty.
l Changes or modifications not expressly approved by the party responsible
for regulatory compliance could void the user’s authority to operate the
equipment.
l Include service loops with cable connections.
l Ensure that the cable bend radius begins at least six inches from the
connector. Cable shielding can be degraded or cables can be damaged or
wear out faster if a service loop or bend radius is tighter than 10X the cable
diameter.
l This device should be used in accordance with the instructions in this
manual.
l All specifications are for reference purposes only and can change without
notice.
3
Symbols
The following symbols indicate safety precautions and supplemental information:
WARNING: This symbol indicates a hazard that could cause death, serious personal injury or
electrical shock.
CAUTION: This symbol indicates a hazard that could result in property damage.
Tip: This symbol indicates suggestions and shortcuts that might not otherwise be apparent.
4
DataMan 280 Series Accessories
You can purchase the following components separately. For a list of options and
accessories, contact your local Cognex sales representative.
Lenses
Accessory Product Number Illustration DM280 DM282
5
Accessory Product Number Illustration DM280 DM282
6
Accessory Product Number Illustration DM280 DM282
7
Illumination
Product
Accessory Illustration DM280 DM282
Number
Red LED Light for 6.2 mm Lens (Risk Group Exempt acc. DM150- ✓
White LED Light for 6.2 mm Lens (Risk Group Exempt DM150- ✓
acc. IEC 62471) LED-WHT
Blue LED Light for 6.2 mm Lens (Risk Group Exempt acc. DM150- ✓
IEC 62471) LED-BLU
24 V DC supply is recommended. HP
8
Lens Covers
Accessory Product Number Illustration DM280 DM282
Standard DM280-CVR-62
front cover. ✓
Use with a
6.2 mm lens
only.
Standard DM280-LENS- ✓
front cover, 62CVR-P
half-
polarized.
Use with a
6.2 mm lens
only.
DM280-LENS-
Standard ✓
62CVR-F
front cover,
fully-
polarized.
Use with a
6.2 mm lens
only.
9
Accessory Product Number Illustration DM280 DM282
Extended
DM260-LENS- ✓
front cover.
Use with a 16 16CVR
mm lens
only.
Extended
DM260-LENS- ✓
front cover,
half- 16CVR-P
polarized.
Use with a 16
mm lens
only.
Extended
DM260-LENS- ✓
front cover,
fully- 16CVR-F
polarized.
Use with a 16
mm lens
only.
C-mount DM280-CMNT-00 ✓
adapter, IP40
C-mount DM280-CMNT-CVR
cover, IP65 ✓
10
Accessory Product Number Illustration DM280 DM282
Cross- 280-HPIT-COVPOL ✓
polarized
cover for
High-Power
Integrated
Torch
Power
Integrated
Torch
Power
Integrated
Torch
11
Accessory Product Number Illustration DM280 DM282
Dome 280-TORCH-DOME ✓
Diffuser
cover for
High-Power
Integrated
Torch
12
Cables
Note: Cables are sold separately.
30m)
13
Accessory Product Number Illustration DM280 DM282
14
Mounting Brackets
Accessory Product Number Illustration DM280 DM282
15
DataMan 280 Systems
2DMax -
Omni- 1D Max PowerGrid Multi-
High Speed Hard to
directional with - Damaged Reader Resolution
Decoding read 2D
1D Code Hotbars 2D codes Sync
codes
DM-280L
1D Codes
DM-
280QL
1D Codes
DM-280S
1D/2D
Codes 1440 x 1080
DM-280Q
1D/2D
Codes
DM-280X
1D/2D
Codes
16
DataMan 282 Systems
2DMax -
Omni- 1D Max PowerGrid Multi-
High Speed Hard to
directional with - Damaged Reader Resolution
Decoding read 2D
1D Code Hotbars 2D codes Sync
codes
DM-282L
1D Codes
DM-
282QL
1D Codes
DM-282S
1D/2D
Codes 1920 x
1080
DM-282Q
1D/2D
Codes
DM-282X
1D/2D
Codes
17
Setting Up Your DataMan Reader
Read this section to learn how the reader connects to its standard components and
accessories.
Note:
l Cables are sold separately.
l If a standard component is missing or damaged, immediately contact
your Cognex Authorized Service Provider (ASP) or Cognex
Technical Support.
CAUTION: All cable connectors are keyed to fit the connectors on the reader.
Do not force the connections or damage may occur.
Reader Layout
DataMan 280 Layout
The image and table below shows the elements of the reader.
18
Number Description
19
Number Description
9
Power LED indicator
10 Train status/Trigger status LED indicator
11 Good/bad read LED indicator
12 Communication LED indicator
13
Error LED indicator
DM282 Layout
The image and table below show the elements of the reader.
20
Number Description
3 Ethernet connector
4
Illumination LEDs
5 LED Aimer
6 Distance Sensor
7 Trigger button
8 Tune button
21
Number Description
9 Indicator LEDs
10 Power LED indicator
11
Train status/Trigger status LED indicator
12
Good/bad inspection LED indicator
13 Communication LED indicator
14 Error LED indicator
22
Dimensions
The following sections list dimensions of the reader.
Note:
l Dimensions are in millimeters and are for reference purposes only.
l All specifications are for reference purposes only and can change
without notice.
23
DataMan 280 with 6.2 mm lens
The following image shows the dimensions of DataMan 280, equipped with 6.2 mm
lens.
24
DataMan 280 with 16 mm Lens
The following image shows the dimensions of DataMan 280 equipped with 16 mm
lens.
25
DataMan 280 with L-shaped extension, equipped with
6.2 mm Lens
The following image shows the dimensions of DataMan 280 equipped with L-
shaped extension and 6.2 mm lens.
26
DataMan 280 with L-shaped extension, equipped with
16 mm Lens
The following image shows the dimensions of DataMan 280 equipped with L-
shaped extension and 16 mm lens.
27
DataMan 282 with High Power Integrated Torch
The following image shows the dimensions of DataMan 282 equipped with high
power integrated torch.
28
DataMan 282 with High Power Integrated Torch - L-
Shaped Extension
The following image shows the dimensions of DataMan 282 equipped with high
power integrated torch and L-shaped extension.
29
DataMan 282 with Dome Front Cover
The following image shows the dimensions of DataMan 282 equipped with a dome
front cover.
30
DataMan 282 with Dome Front Cover - Right Angle
Configuration
The following image shows the dimensions of DataMan 282 equipped with L-
shaped extension and dome front cover.
31
Field of View and Reading Distance
This section provides the Field of View (FoV) values for 6.2 mm and 16 mm lenses.
32
Working distance in mm Horizontal values in mm Vertical values in mm
40 4 2
65 5 3
105 10 5
33
Distances in mm 2D min. code in mil 1D min. code in mil
150 10 6
190 12 8
225 15 8
375 20 15
500 30 20
1000 60 35
34
DataMan 280 Readers with 16 mm lens
The following tables list the Field of View (FoV) widths of the 16 mm lens at various
distances:
Z2 = 225 X2 = 69 Y2 = 52
35
Working distance in mm Horizontal values in mm Vertical values in mm
Z3 = 375 X3 = 116 Y3 = 87
80 2 2
150 3 2
190 4 3
225 5 3
375 8 5
500 10 7
1000 20 15
36
DataMan 282 Readers with 8 mm Lens
300 12 7
750 18 12
1200 22 15
37
DataMan 282 Readers with 12 mm Lens
Z1 = 300 X1 = 141 Y1 = 79
300 10 6
750 18 11
1200 22 15
38
DataMan 282 Readers with 16 mm Lens
Z1 = 300 X1 = 105 Y1 = 59
300 8 5
750 16 9
1200 22 14
39
Mounting the Reader
The reader provides mounting holes for attachment to a mounting surface.
40
Align the holes on the mounting surface with the mounting holes on the reader.
Insert the M3X5 screws into the mounting holes.
Align the holes on the mounting surface with the mounting holes on the reader. With
the reader in right-angle position, only the back mounting holes can be used. To
mount the device in right-angle position, use the M3X9 screws.
41
Note:
Mounting the reader at a slight angle (15°) reduces reflections and improves
performance.
42
Connecting the Ethernet Cable
CAUTION: The Ethernet cable shield has to be grounded at the far end.
Whatever this cable is plugged into (typically a switch or router) should have a
grounded Ethernet connector. A digital voltmeter has to be used to validate
the grounding. If the far end device is not grounded, a ground wire should be
added in compliance with local electrical codes.
Note:
43
Connecting the Power and I/O Breakout Cable
CAUTION: To reduce emissions, connect the far end of the Breakout cable
shield to frame ground.
Note:
l Perform wiring or adjustments to I/O devices when the reader is not
receiving power.
l You can clip unused wires short or use a tie made of non-conductive
material to tie them back. Keep bare wires separated from the +24 V
DC wire.
3. Attach the M12 connector of the Power and I/O Breakout Cable to the 24 V
DC connector of the reader.
4. Restore power to the 24 V DC power supply and turn it on if necessary.
44
Specifications
The following sections list general specifications for the reader.
Ethernet
Supply
45
Specification DataMan 280 DataMan 282
0–40 °C (32–104 °F)
Operating
Temperature
-10–60 °C (14–140 °F)
Storage
Temperature
Note: IP67 rating applies only if all blind plugs and cables are attached properly, or
the provided connector plug is installed. Also, make sure that the IP67-rated cover is
installed properly.
IEC 60068-2-27 - 500 shocks in each polarity of each (X, Y, and Z) axis, 3000 shocks total,
Shock
semi-sinusoidal, 11 g, 10 ms
ISTA-1A Standardized Testing - Packaged Products 150 lb or less
Shock
(Shipping and
Storage)
Vibration IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to 500
2
Hz at 100m/s / 15 mm)
FedEx Vibration Testing for packaged products 150 lbs or less
Vibration
(Shipping and
Storage)
1-D barcodes: Codabar, Code 39, Code 128, Code 93, Code 25, Interleaved 2 of 5, Postal
Codes
Codes, UPC/EAN/JAN, MSI
2-D barcodes: Data Matrix (IDMax and IDQuick: ECC 0, 50, 80, 100, 140, and 200), QR
Code, microQR, PDF 417, AztecCode, DotCode, MaxiCode
46
DataMan 280 Series Reader Image Sensor
Specification DataMan 280 DataMan 282
1/3-inch CMOS, global shutter 1/3-inch CMOS, global shutter
Image Sensor
Diagonal size: 6.21 mm Diagonal size: 6.17 mm
Image Sensor Properties Pixel size: 3.45 μm (H) x 3.45 μm (V) Pixel size: 2.8 μm (H) x 2.8 μm (V)
1440 x 1080 (1.6 mp) 1920 x 1080 pixels (2 mp)
Image Resolution (pixels)
Minimum exposure: 43 μs Minimum exposure: 30 μs
Electronic Shutter Speed Maximum exposure: 200 ms (with Maximum exposure: 200 ms (with
external illumination) external illumination)
Maximum: 45 Hz
Image Acquisition at Full
Resolution
l 6.2 mm (3 pos or LLM) with l 8 mm
Lens Type
IR blocking filter
l 12 mm
l 16 mm (manual or LLM) with
IR blocking filter l 16 mm High Speed Liquid
l 6.2 mm UV, 6.2 mm Lens
47
LED Wavelengths
The following table shows LED types and the related dominant wavelengths.
LED λ [nm]
RED 617
BLUE 470
IR 850
IR HPIL 850
UV 365
48
Regulations and Conformity
Note: For the most current CE and UKCA declaration and regulatory
conformity information, see the Cognex support site: cognex.com/support.
DataMan 280 readers have Regulatory Model numbers 50208, 50210, 50215,
50216, and meet or exceed the requirements of all applicable standards
organizations for safe operation. However, as with any electrical equipment, the
best way to ensure safe operation is to operate them according to the agency
guidelines that follow. Please read these guidelines carefully before using your
device.
49
Safety and Regulatory
FCC Part 15, Class A
FCC This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
Korea This device is certified for office use only and if used at home, there can be
frequency interference problems.
A급 기기 (업 무용 방송통신기 자재): 이 기기 는 업 무용(A급) 전자 파적 합 기기 로
서 판 매 자 또는 사용 자는 이 점을 주 의하시 기 바라 며 , 가정외 의 지역 에 서 사
용 하는 것 을 목 적으 로 합니다.
DataMan 280 1.6 MP: R-R-CGX-50208
DataMan 280 1.6 MP L-shaped: R-R-CGX-50210
DataMan 280 2 MP: R-R-CGX-50215
DataMan 280 2 MP L-shaped: R-R-CGX-50216
DataMan 280 1.6 MP: Regulatory Model 50208
TÜV DataMan 280 1.6 MP L-shaped: Regulatory Model 50210
DataMan 280 2 MP: Regulatory Model 50215
DataMan 280 2 MP L-shaped: Regulatory Model 50216
50
中 国 大 陆 RoHS (Information for China RoHS
Compliance)
根据 中国 大陆 《电子信息 产品 污染 控制管 理办 法 》( 也称 为中 国大陆 RoHS),以
下部 份列 出了 本产 品中可 能包 含的 有 毒有 害物 质或 元素的 名称 和含 量 。
Hazardous Substances 有 害物 质
Part Name Lead (Pb) Mercury Cadmium Hexavalent Polybrominated Polybrominated
部件 名称 铅 (Hg) (Cd) Chromium biphenyls (PBB) diphenyl ethers
汞 镉 (Cr (VI)) 多 溴联苯 (PBDE)
六价铬 多溴二 苯 醚
Regulatory
X O O O O O
Model
50208
Regulatory
Model
50210
Regulatory
Model
50215
Regulatory
Model
50216
This table is prepared in accordance with the provisions of SJ/T 11364.
这个 标签 是根据 SJ / T 11364 的规 定 准备的 。
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is
below the limit requirement of GB / T26572 - 2011.
表示 本部 件所有 均 质材 料中含 有的 有害物 质低 于GB / T26572 - 2011 的限 量要求 。
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials used for
this part is above the limit requirement of GB / T26572 - 2011.
表示 用于 本部件 的 至少 一种均 质材 料中所 含的 危害物质超 过GB / T26572 - 2011 的限 制要 求 。
51
For European Community Users
Cognex complies with Directive 2012/19/EU OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic
equipment (WEEE).
This product has required the extraction and use of natural resources for its
production. It may contain hazardous substances that could impact health and the
environment, if not properly disposed.
In order to avoid the dissemination of those substances in our environment and to
diminish the pressure on the natural resources, we encourage you to use the
appropriate take-back systems for product disposal. Those systems will reuse or
recycle most of the materials of the product you are disposing in a sound way.
The crossed out wheeled bin symbol informs you that the product should not
be disposed of along with municipal waste and invites you to use the appropriate
separate take-back systems for product disposal.
If you need more information on the collection, reuse, and recycling systems,
please contact your local or regional waste administration.
You may also contact your supplier for more information on the environmental
performance of this product.
52
Copyright © 2024
Cognex Corporation. All Rights Reserved.