DataMan® 280 Series

Quick Reference Guide

2024 October 01
Revision: 24.3.0.11
Precautions
To reduce the risk of injury or equipment damage, observe the following
precautions when you install the Cognex product:
l Connectivity is possible through the following options:
l 24 VDC (+/- 10%) output connection using a UL or NTRL listed
power supply
l Power over Ethernet (PoE) 13 W power supply
Any other voltage creates a risk of fire or shock and can damage the
components. Applicable national and local wiring standards and rules must
be followed.
l This product is intended for industrial use in automated manufacturing or
similar applications.
l The safety of any system incorporating this product is the responsibility of
the assembler of the system.
l Do not install Cognex products where they are exposed to environmental
hazards such as excessive heat, dust, moisture, humidity, impact,
vibration, corrosive substances, flammable substances, or static electricity.
l Route cables and wires away from high-current wiring or high-voltage
power sources to reduce the risk of damage or malfunction from the
following causes: over-voltage, line noise, electrostatic discharge (ESD),
power surges, or other irregularities in the power supply.
l Do not expose the image sensor to laser light. Image sensors can be
damaged by direct, or reflected, laser light. If your application requires
laser light that might strike the image sensor, use a lens filter at the
corresponding laser wavelength. For suggestions, contact your local
integrator or application engineer.

2
l This product does not contain user-serviceable parts. Do not make
electrical or mechanical modifications to product components.
Unauthorized modifications can void your warranty.
l Changes or modifications not expressly approved by the party responsible
for regulatory compliance could void the user’s authority to operate the
equipment.
l Include service loops with cable connections.
l Ensure that the cable bend radius begins at least six inches from the
connector. Cable shielding can be degraded or cables can be damaged or
wear out faster if a service loop or bend radius is tighter than 10X the cable
diameter.
l This device should be used in accordance with the instructions in this
manual.
l All specifications are for reference purposes only and can change without
notice.

3
Symbols
The following symbols indicate safety precautions and supplemental information:

WARNING: This symbol indicates a hazard that could cause death, serious personal injury or
electrical shock.

CAUTION: This symbol indicates a hazard that could result in property damage.

Note: This symbol indicates additional information about a subject.

Tip: This symbol indicates suggestions and shortcuts that might not otherwise be apparent.

4
DataMan 280 Series Accessories
You can purchase the following components separately. For a list of options and
accessories, contact your local Cognex sales representative.

Lenses
Accessory Product Number Illustration DM280 DM282

6.2 mm lens kit that includes: DM280-LENS-62



l 6.2 mm optics mount
l 6.2 mm lens
l Manual lens cap (assembled)
l Screws
UV Light Kit for 6.2 mm lens (Risk Group
DM280-UV365-62 ✓
Exempt acc. IEC 62471)
l UV light board (365 nm
wavelength)
l UV resistant front cover
l Screws
16 mm lens kit with extended optics mount DM260-LENS-16
(requires the use of an extended front cover ✓
and high-powered red LED). The kit
includes:
l 16 mm optics mount
l 16 mm lens
l Manual lens cap (assembled)
l Screws

5
Accessory Product Number Illustration DM280 DM282

IR 6.2 mm lens kit, 3-position with IR LED DM280-KIT-IR-62


includes: ✓

l 6.2 mm optics mount


l 6.2 mm lens (IR)
l Standard Infrared Light for
6.2mm (Risk Group Exempt acc.
IEC62471)
l Manual lens cap (not assembled)
l Screws
IR 16 mm lens kit that includes: DMA-KIT-IR-16

l 16 mm optics mount
l 16 mm lens (IR)
l Standard Infrared Light for 16mm
(Risk Group Exempt acc.
IEC62471)
l Manual lens cap (assembled)
l Screws
High Speed Liquid Lens Module (HSLL) to DMA-HSLL-280
be used with 6.2 mm lens or 16 mm lens ✓ ✓

6
Accessory Product Number Illustration DM280 DM282

16 mm lens with ImageMax kit that includes: DM280-KIT-IMGMAX



l 16 mm optics mount
l 16 mm lens
l High Speed Liquid Lens Module
(DMA-HSLL-280)
l High Powered red LED
illumination (DM260-LED-RED-
HP) (Risk Group Exempt acc.
IEC62471)
l 2-LED half-polarized extended
cover (DM260-LENS-16CVR-P)
(Risk Group Exempt acc.
IEC62471)
Blue bandpass filter DM150-BP470

Blue bandpass filter, 450 nm 280-TORCH-BP450


Red bandpass filter DM150-BP635


Red bandpass filter, 635 nm 280-TORCH-BP635


7
Illumination
Product
Accessory Illustration DM280 DM282
Number

Red LED Light for 6.2 mm Lens (Risk Group Exempt acc. DM150- ✓

IEC 62471) LED-RED

White LED Light for 6.2 mm Lens (Risk Group Exempt DM150- ✓
acc. IEC 62471) LED-WHT

Blue LED Light for 6.2 mm Lens (Risk Group Exempt acc. DM150- ✓
IEC 62471) LED-BLU

High-Powered Red LED Light for 16 mm Lens (Risk DM280- ✓


Group Exempt acc. IEC 62471) For maximum light power LED-RED-

24 V DC supply is recommended. HP

High-Powered White LED Light for 16 mm Lens (Risk DM280- ✓

Group Exempt acc. IEC 62471)For maximum light power LED-

24 V DC supply is recommended. WHT-HP

8
Lens Covers
Accessory Product Number Illustration DM280 DM282

Standard DM280-CVR-62
front cover. ✓
Use with a
6.2 mm lens
only.

Standard DM280-LENS- ✓
front cover, 62CVR-P

half-

polarized.

Use with a

6.2 mm lens

only.
DM280-LENS-
Standard ✓
62CVR-F
front cover,

fully-

polarized.

Use with a

6.2 mm lens

only.

9
Accessory Product Number Illustration DM280 DM282

Extended
DM260-LENS- ✓
front cover.
Use with a 16 16CVR
mm lens
only.
Extended
DM260-LENS- ✓
front cover,
half- 16CVR-P
polarized.
Use with a 16
mm lens
only.
Extended
DM260-LENS- ✓
front cover,
fully- 16CVR-F
polarized.
Use with a 16
mm lens
only.

C-mount DM280-CMNT-00 ✓
adapter, IP40

C-mount DM280-CMNT-CVR
cover, IP65 ✓

10
Accessory Product Number Illustration DM280 DM282

Cross- 280-HPIT-COVPOL ✓
polarized

cover for

High-Power

Integrated

Torch

Clear cover 280-HPIT-COVCLR ✓


for High-

Power

Integrated

Torch

Diffuse cover 280-HPIT-COVDIF ✓


for High-

Power

Integrated

Torch

11
Accessory Product Number Illustration DM280 DM282

Dome 280-TORCH-DOME ✓
Diffuser

cover for

High-Power

Integrated

Torch

Note: A reader with HPIT does not need a lens cover.

CAUTION: For 280-HPIT-COVPOL, 280-HPIT-COVCLR, and 280-HPIT-


COVDIF equipped with a laser aimer, the device has been tested to be under
the limits of a Class 1 Laser device.

12
Cables
Note: Cables are sold separately.

Accessory Product Number Illustration DM280 DM282

Ethernet Cable, X-coded CCB-84901-2001-xx (straight, xx ✓ ✓


M12-8 to RJ-45 specifies length: 2m, 5m, 10m, 15m,

30m)

Ethernet Cable, X-coded CCB-84901-2002-xx (right-angled, xx ✓ ✓


M12-8 to RJ-45 specifies length: 2m, 5m, 10m)

Ethernet Cable, Robotic X- CCB-84901-2RBT-xx (straight, xx ✓ ✓


Coded M12-8 to RJ-45 specifies length: 2m, 5m, 10m)

X-Coded to A-Coded Ethernet CCB-M12X8MS-XCAC ✓ ✓


cable adapter, 0.5 m

Power and I/O Breakout CCB-M12x12Fy-05 (y = straight/angled, ✓ ✓


Cable, M12-12 to Flying Lead xx specifies length)

Power and I/O Breakout CCBL-05-01 ✓ ✓

Cable, M12-12 to Flying Lead

Power and I/O Breakout CCB-PWRIO- xx (straight, xx specifies ✓ ✓


Cable, M12-12 to Flying Lead length: 5m, 10m, 15m)

13
Accessory Product Number Illustration DM280 DM282

Power and I/O Breakout CCB-PWRIO-xxR (right-angled, xx ✓ ✓


Cable, M12-12 to Flying Lead specifies length: 5m, 10m, 15m)

Power and I/O Breakout CCB-PWRIO-MOD-xx (xx specifies ✓ ✓

Cable, M12-12 to DB15 length: 2m, 5m)

RS-232 Connection Cable CCB-M12xDB9Y-05 ✓ ✓

I/O Extension Cable CKR-200-CBL-EXT ✓ ✓

SealedUSB Type C Cable to DMA-STCBLE-IP65-25 ✓ ✓


USB Type A, Straight, 2.5 m

SealedUSB Type C Cable to DMA-STCBLE-IP65-36 ✓ ✓


USB Type A, Straight 3.6 m

Sealed USB Type C Cable to DMA-RTCBLE-IP65-25 ✓ ✓

USB Type A, Angled, 2.5 m

Sealed USB Type C Cable to DMA-RTCBLE-IP65-36 ✓ ✓


USB Type A, Angled, 3.6 m

14
Mounting Brackets
Accessory Product Number Illustration DM280 DM282

Universal mounting bracket DM100-UBRK-000 ✓ ✓

Pivot mounting bracket DM100-PIVOTM-01


✓ ✓

Tilted angle pivot bracket DMBK-DMPIVOT-00 ✓ ✓

Logistics mounting bracket and plate kit DMA-BKT-LGS ✓ ✓

Adjustable mirror bracket DMA-262-MIR ✓

DataMan 280 Series Systems

15
DataMan 280 Systems
2DMax -
Omni- 1D Max PowerGrid Multi-
High Speed Hard to
directional with - Damaged Reader Resolution
Decoding read 2D
1D Code Hotbars 2D codes Sync
codes
DM-280L
1D Codes

DM-
280QL
1D Codes

DM-280S
1D/2D
Codes 1440 x 1080

DM-280Q
1D/2D
Codes

DM-280X
1D/2D
Codes

16
DataMan 282 Systems
2DMax -
Omni- 1D Max PowerGrid Multi-
High Speed Hard to
directional with - Damaged Reader Resolution
Decoding read 2D
1D Code Hotbars 2D codes Sync
codes
DM-282L
1D Codes

DM-
282QL
1D Codes

DM-282S
1D/2D
Codes 1920 x
1080

DM-282Q
1D/2D
Codes

DM-282X
1D/2D
Codes

17
Setting Up Your DataMan Reader
Read this section to learn how the reader connects to its standard components and
accessories.

Note:
l Cables are sold separately.
l If a standard component is missing or damaged, immediately contact
your Cognex Authorized Service Provider (ASP) or Cognex
Technical Support.

CAUTION: All cable connectors are keyed to fit the connectors on the reader.
Do not force the connections or damage may occur.

Reader Layout
DataMan 280 Layout
The image and table below shows the elements of the reader.

18
Number Description

1 Power I/O Breakout cable connector

2 USB-C slot (with plastic cover)


3
Ethernet connector
4
Illumination LEDs
5 LED aimers
6 Trigger button
7 Tune button
8
Indicator LEDs

19
Number Description
9
Power LED indicator
10 Train status/Trigger status LED indicator
11 Good/bad read LED indicator
12 Communication LED indicator
13
Error LED indicator

DM282 Layout
The image and table below show the elements of the reader.

20
Number Description

1 Power I/O Breakout cable connector

2 USB-C slot (with plastic cover)

3 Ethernet connector
4
Illumination LEDs

5 LED Aimer

6 Distance Sensor

7 Trigger button
8 Tune button

21
Number Description

9 Indicator LEDs
10 Power LED indicator
11
Train status/Trigger status LED indicator
12
Good/bad inspection LED indicator
13 Communication LED indicator
14 Error LED indicator

22
Dimensions
The following sections list dimensions of the reader.

Note:
l Dimensions are in millimeters and are for reference purposes only.
l All specifications are for reference purposes only and can change
without notice.

23
DataMan 280 with 6.2 mm lens
The following image shows the dimensions of DataMan 280, equipped with 6.2 mm
lens.

24
DataMan 280 with 16 mm Lens
The following image shows the dimensions of DataMan 280 equipped with 16 mm
lens.

25
DataMan 280 with L-shaped extension, equipped with
6.2 mm Lens
The following image shows the dimensions of DataMan 280 equipped with L-
shaped extension and 6.2 mm lens.

26
DataMan 280 with L-shaped extension, equipped with
16 mm Lens
The following image shows the dimensions of DataMan 280 equipped with L-
shaped extension and 16 mm lens.

27
DataMan 282 with High Power Integrated Torch
The following image shows the dimensions of DataMan 282 equipped with high
power integrated torch.

28
DataMan 282 with High Power Integrated Torch - L-
Shaped Extension
The following image shows the dimensions of DataMan 282 equipped with high
power integrated torch and L-shaped extension.

29
DataMan 282 with Dome Front Cover
The following image shows the dimensions of DataMan 282 equipped with a dome
front cover.

30
DataMan 282 with Dome Front Cover - Right Angle
Configuration
The following image shows the dimensions of DataMan 282 equipped with L-
shaped extension and dome front cover.

31
Field of View and Reading Distance
This section provides the Field of View (FoV) values for 6.2 mm and 16 mm lenses.

DataMan 280 Readers with 6.2 mm Lens


6.2 mm lenses can be focused to 105 mm (short range) and to 190 mm (long
range).
Short Range (Focused to 105 mm)
The following tables show the Field of View (FoV) widths of the 6.2 mm lens
focused to 105 mm at various distances.

32
Working distance in mm Horizontal values in mm Vertical values in mm

Z1= 40 X1= 38 Y1= 29

Z2= 65 X2= 58 Y2= 44

Z3= 105 X3= 90 Y3= 68

Distances in mm 2D min. code in mil 1D min. code in mil

40 4 2

65 5 3

105 10 5

Long Range (Focused to 190 mm)


The following table shows the Field of View (FoV) widths of the 6.2 mm lens
focused to 190 mm at various distances.

Working distance in mm Horizontal values in mm Vertical values in mm

Z1= 190 X1= 159 Y1= 119

Z2= 225 X2= 187 Y2= 140

Z3 = 375 X3 = 307 Y3 = 230

Z4 = 1000 X4 = 808 Y4 = 606

33
Distances in mm 2D min. code in mil 1D min. code in mil

150 10 6

190 12 8

225 15 8

375 20 15

500 30 20

1000 60 35

34
DataMan 280 Readers with 16 mm lens

The following tables list the Field of View (FoV) widths of the 16 mm lens at various
distances:

Working distance in mm Horizontal values in mm Vertical values in mm

Z1= 150 X1= 46 Y1= 34

Z2 = 225 X2 = 69 Y2 = 52

35
Working distance in mm Horizontal values in mm Vertical values in mm

Z3 = 375 X3 = 116 Y3 = 87

Z4 = 1000 X4 = 310 Y4 = 232

Distances in mm 2D min. code in mil 1D min. code in mil

80 2 2

150 3 2

190 4 3

225 5 3

375 8 5

500 10 7

1000 20 15

36
DataMan 282 Readers with 8 mm Lens

Working distance in mm Horizontal values in mm Vertical values in mm

Z1 = 300 X1 = 223 Y1 = 125

Z2 = 750 X2 = 526 Y2 = 295

Z3 = 1200 X3 = 828 Y3 = 466

Working Distance in mm 2D min. code in mil 1D min. code in mil

300 12 7

750 18 12

1200 22 15

37
DataMan 282 Readers with 12 mm Lens

Working distance in mm Horizontal values in mm Vertical values in mm

Z1 = 300 X1 = 141 Y1 = 79

Z2 = 750 X2 = 343 Y2 = 193

Z3 = 1200 X3 = 545 Y3 = 306

Working Distance in mm 2D min. code in mil 1D min. code in mil

300 10 6

750 18 11

1200 22 15

38
DataMan 282 Readers with 16 mm Lens

Working distance in mm Horizontal values in mm Vertical values in mm

Z1 = 300 X1 = 105 Y1 = 59

Z2 = 750 X2 = 256 Y2 = 144

Z3 = 1200 X3 = 407 Y3 = 229

Working Distance in mm 2D min. code in mil 1D min. code in mil

300 8 5

750 16 9

1200 22 14

39
Mounting the Reader
The reader provides mounting holes for attachment to a mounting surface.

CAUTION: The reader has to be grounded, either by mounting the reader to


a fixture that is electrically grounded or by attaching a wire from the reader’s
mounting fixture to frame ground or Earth ground. If a ground wire is used, it
has to be attached to one of the four mounting points on the bottom plate of
the reader and not to the mounting points on the front of the reader.

The method of mounting depends on whether the reader is in straight or right-angle


configuration, regardless of the product variant.

Mounting the Reader in Straight Configuration

40
Align the holes on the mounting surface with the mounting holes on the reader.
Insert the M3X5 screws into the mounting holes.

Mounting the Reader in Right-Angle Configuration

Align the holes on the mounting surface with the mounting holes on the reader. With
the reader in right-angle position, only the back mounting holes can be used. To
mount the device in right-angle position, use the M3X9 screws.

41
Note:
Mounting the reader at a slight angle (15°) reduces reflections and improves
performance.

42
Connecting the Ethernet Cable
CAUTION: The Ethernet cable shield has to be grounded at the far end.
Whatever this cable is plugged into (typically a switch or router) should have a
grounded Ethernet connector. A digital voltmeter has to be used to validate
the grounding. If the far end device is not grounded, a ground wire should be
added in compliance with local electrical codes.

1. Connect the Ethernet cable's M12 connector to the reader ENET


connector.
2. Connect the Ethernet cable’s RJ-45 connector to a switch/router or PC, as
applicable.

Note:

Besides powering the DataMan 280 readers through a Breakout


Cable, it is possible to power DataMan through PoE connection as
well, in which case it is not necessary to use a Breakout Cable.
DataMan 282 readers do not support PoE.

DataMan 282 Readers LED Behavior with PoE


DataMan 282 Readers require 24 V DC to operate. If you try to power the reader
with a PoE cable, the reader boots up, but the illumination shuts down. The error
LED of the reader turns solid red to indicate an underpowered state. You can
overwrite the behavior of the error LED in the Inputs / Outputs application step of
the DataMan Setup Tool. For more information on how to configure the error LED,
refer to the DataMan Questions and Answers document.

43
Connecting the Power and I/O Breakout Cable
CAUTION: To reduce emissions, connect the far end of the Breakout cable
shield to frame ground.

Note:
l Perform wiring or adjustments to I/O devices when the reader is not
receiving power.
l You can clip unused wires short or use a tie made of non-conductive
material to tie them back. Keep bare wires separated from the +24 V
DC wire.

1. Verify that the 24 V DC power supply is unplugged and not receiving


power.
2. Attach the +24 V DC connector of the Power and I/O Breakout cable and
Ground wires to the corresponding terminals on the power supply. For
more information, see Specifications on page 45.

CAUTION: Never connect voltages other than 24 V DC. Always


observe the polarity shown.

3. Attach the M12 connector of the Power and I/O Breakout Cable to the 24 V
DC connector of the reader.
4. Restore power to the 24 V DC power supply and turn it on if necessary.

Using your Device through USB


For a detailed description, see the DataMan 280 Reference Manual.

44
Specifications
The following sections list general specifications for the reader.

DataMan 280 Series Reader


Specification DataMan 280 DataMan 282
6.2 mm: 141 g HPIT: 290 g
Weight 16 mm: 169 g Right angle configuration adds 50 g
Right angle configuration adds 50 g
24 V DC +/- 10%, PoE (Power over Ethernet) 24 V DC ± 10%
Power
24 V DC ± 10%
24 V Supply LPS or NEC class 2
Power consumption without USB device Power consumption:
attached:
l Average ≤ 5 W
l Average ≤ 5 W using High-
l Peak 10.7 W
Powered Light
l Average ≤ 6 W using High
Frequency High-Powered Light
l Peak ≤ 1.6 A using internal
illumination
PoE Class 3
Power over N/A

Ethernet

Supply

45
Specification DataMan 280 DataMan 282
0–40 °C (32–104 °F)
Operating

Temperature
-10–60 °C (14–140 °F)
Storage

Temperature

Humidity <95% non-condensing


IP67
Environmental

Note: IP67 rating applies only if all blind plugs and cables are attached properly, or
the provided connector plug is installed. Also, make sure that the IP67-rated cover is
installed properly.

IEC 60068-2-27 - 500 shocks in each polarity of each (X, Y, and Z) axis, 3000 shocks total,
Shock
semi-sinusoidal, 11 g, 10 ms
ISTA-1A Standardized Testing - Packaged Products 150 lb or less
Shock

(Shipping and

Storage)

Vibration IEC 60068-2-6: vibration test in each of the three main axis for 2 hours @ 10 Gs (10 to 500
2
Hz at 100m/s / 15 mm)
FedEx Vibration Testing for packaged products 150 lbs or less
Vibration

(Shipping and

Storage)
1-D barcodes: Codabar, Code 39, Code 128, Code 93, Code 25, Interleaved 2 of 5, Postal
Codes
Codes, UPC/EAN/JAN, MSI
2-D barcodes: Data Matrix (IDMax and IDQuick: ECC 0, 50, 80, 100, 140, and 200), QR
Code, microQR, PDF 417, AztecCode, DotCode, MaxiCode

46
DataMan 280 Series Reader Image Sensor
Specification DataMan 280 DataMan 282
1/3-inch CMOS, global shutter 1/3-inch CMOS, global shutter
Image Sensor
Diagonal size: 6.21 mm Diagonal size: 6.17 mm
Image Sensor Properties Pixel size: 3.45 μm (H) x 3.45 μm (V) Pixel size: 2.8 μm (H) x 2.8 μm (V)
1440 x 1080 (1.6 mp) 1920 x 1080 pixels (2 mp)
Image Resolution (pixels)
Minimum exposure: 43 μs Minimum exposure: 30 μs
Electronic Shutter Speed Maximum exposure: 200 ms (with Maximum exposure: 200 ms (with
external illumination) external illumination)
Maximum: 45 Hz
Image Acquisition at Full

Resolution
l 6.2 mm (3 pos or LLM) with l 8 mm
Lens Type
IR blocking filter
l 12 mm
l 16 mm (manual or LLM) with
IR blocking filter l 16 mm High Speed Liquid
l 6.2 mm UV, 6.2 mm Lens

l 16 mm IR, C-Mount acc.

47
LED Wavelengths
The following table shows LED types and the related dominant wavelengths.

LED λ [nm]

RED 617

RED HPIL 617

BLUE 470

WHITE 6500K (Color temperature)

IR 850

IR HPIL 850

UV 365

48
Regulations and Conformity
Note: For the most current CE and UKCA declaration and regulatory
conformity information, see the Cognex support site: cognex.com/support.

DataMan 280 readers have Regulatory Model numbers 50208, 50210, 50215,
50216, and meet or exceed the requirements of all applicable standards
organizations for safe operation. However, as with any electrical equipment, the
best way to ensure safe operation is to operate them according to the agency
guidelines that follow. Please read these guidelines carefully before using your
device.

Safety and Regulatory


Cognex Corporation
Manufacturer One Vision Drive
Natick, MA 01760 USA
DataMan 280 1.6 MP: Regulatory Model 50208
DataMan 280 1.6 MP L-shaped: Regulatory Model 50210
DataMan 280 2 MP: Regulatory Model 50215
DataMan 280 2 MP L-shaped: Regulatory Model 50216
This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take immediate measures.
This equipment complies with the essential requirements of the EU Directive
2014/30/EU. Declarations are available from your local representative.

EU RoHS Compliant to the most recent applicable directive.

49
Safety and Regulatory
FCC Part 15, Class A
FCC This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his
own expense.
Korea This device is certified for office use only and if used at home, there can be
frequency interference problems.
A급 기기 (업 무용 방송통신기 자재): 이 기기 는 업 무용(A급) 전자 파적 합 기기 로
서 판 매 자 또는 사용 자는 이 점을 주 의하시 기 바라 며 , 가정외 의 지역 에 서 사
용 하는 것 을 목 적으 로 합니다.
DataMan 280 1.6 MP: R-R-CGX-50208
DataMan 280 1.6 MP L-shaped: R-R-CGX-50210
DataMan 280 2 MP: R-R-CGX-50215
DataMan 280 2 MP L-shaped: R-R-CGX-50216
DataMan 280 1.6 MP: Regulatory Model 50208
TÜV DataMan 280 1.6 MP L-shaped: Regulatory Model 50210
DataMan 280 2 MP: Regulatory Model 50215
DataMan 280 2 MP L-shaped: Regulatory Model 50216

NRTL: TÜV SÜD SCC/NRTL OSHA Scheme for UL/CAN 61010-1.

CB report available upon request. TÜV SÜD, IEC/EN 61010-1.


DataMan 280 1.6 MP: Regulatory Model 50208
DataMan 280 2 MP L-shaped: Regulatory Model 50216
This is a class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take immediate measures.
This equipment complies with the essential requirements of the Electromagnetic
Compatibility Regulations 2016. Declarations are available from your local
representative.

50
中 国 大 陆 RoHS (Information for China RoHS
Compliance)
根据 中国 大陆 《电子信息 产品 污染 控制管 理办 法 》( 也称 为中 国大陆 RoHS),以
下部 份列 出了 本产 品中可 能包 含的 有 毒有 害物 质或 元素的 名称 和含 量 。

Hazardous Substances 有 害物 质
Part Name Lead (Pb) Mercury Cadmium Hexavalent Polybrominated Polybrominated
部件 名称 铅 (Hg) (Cd) Chromium biphenyls (PBB) diphenyl ethers
汞 镉 (Cr (VI)) 多 溴联苯 (PBDE)
六价铬 多溴二 苯 醚
Regulatory
X O O O O O
Model
50208
Regulatory
Model
50210
Regulatory
Model
50215
Regulatory
Model
50216
This table is prepared in accordance with the provisions of SJ/T 11364.
这个 标签 是根据 SJ / T 11364 的规 定 准备的 。
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is
below the limit requirement of GB / T26572 - 2011.
表示 本部 件所有 均 质材 料中含 有的 有害物 质低 于GB / T26572 - 2011 的限 量要求 。
X: Indicates that said hazardous substance contained in at least one of the homogeneous materials used for
this part is above the limit requirement of GB / T26572 - 2011.
表示 用于 本部件 的 至少 一种均 质材 料中所 含的 危害物质超 过GB / T26572 - 2011 的限 制要 求 。

51
For European Community Users
Cognex complies with Directive 2012/19/EU OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic
equipment (WEEE).
This product has required the extraction and use of natural resources for its
production. It may contain hazardous substances that could impact health and the
environment, if not properly disposed.
In order to avoid the dissemination of those substances in our environment and to
diminish the pressure on the natural resources, we encourage you to use the
appropriate take-back systems for product disposal. Those systems will reuse or
recycle most of the materials of the product you are disposing in a sound way.

The crossed out wheeled bin symbol informs you that the product should not
be disposed of along with municipal waste and invites you to use the appropriate
separate take-back systems for product disposal.
If you need more information on the collection, reuse, and recycling systems,
please contact your local or regional waste administration.
You may also contact your supplier for more information on the environmental
performance of this product.

52