ACS800 Ordering Information

Frequency Converters
and Factory-Installed
Optional Devices

Code: 3AFY64556568
Effective from: 17 October 2011
Supersedes: 17 June 2011
Ordering Information
Updated: 12 October 2011
Overview

This document consists of:


- a Type Code Key
- ACS800-... Type Code Sheets (=Order Sheets).

Only the ACS 800 units and the built-in optional devices specified in this document can be
ordered with the codes given here. However, many of the optional devices are also
available as Add-On Kits, and these kits must be ordered separately. For the Add-On Kits
ordering codes, please see the ACS 800 price list.

The Type Code for ordering an ACS 800 unit consists of two parts: the characters in the
first part (min. 16 characters), identify the basic product with default features. The optional
devices are ordered by four-digit option codes which are separated by '+' signs. On the next
page you will find an example of a Type Code Key with legends. With the aid of the Type
Code Sheet you will be able to form the correct ordering code (technical definition) for the
unit(s) you wish to buy.

Various combinations of and restrictions to the available options are explained in detail on
the respective Option Sheets. Not released products are shown in grey

The Type Code Sheet filled in with the requested information about the basic product and
quantity of the selected options can be included in the order or you can copy the correct
Type Code onto your order sheet. Please send the order by Lotus Notes or by fax to the
country responsible Sales Administrator in Helsinki.
Type Code Key
ACS 8 0 0 - 0 1 - 0 0 7 0 - 3 + X X X X +

Product Series

Construction

Size

Voltage Rating

Option codes

Example ACS800 - 01 - 0020 - 3 + E202 + 2L501 + L503

20 kVA 400 V basic drive

EMC filter

2pcs of Digital I/O extensions RDIO-01

DDCS Communication 3
Ordering Information
Updated on 12 October 2011

How to fill in the Industry Segment, Application Area and Distribution Channel
boxes on the Order Sheets
On the subsequent Order Sheets (Type Code Sheets), you will need to fill in the Industry Segment,
Application Area and Distribution Channel boxes on top of each sheet.
Below is a list of the Industry Segment, Application Area and Distribution Channel abbreviations
defined in our Order Processing System (SAP). On the Order Sheets, you may view these using the
Industry Segment, Application Area and Distribution Channel scroll bars and then select the respective
abbreviations from the Industry Segment, Application Area and Distribution Channel drop-down menus.
Abbreviations for Industry Segments and Application Areas (you may view these on the Order Sheets)
Industry Segments Application Areas

AUT - Automotive CAB - Cable car


CEM - Cement CAL - Calander line
CHE - Chemical CEN - Centrifuge
CON - Consumer industry COA - Coating
ELE - Electronics COM - Compressor
FOO - Food and Beverage CON - Conveyor
HVA - HVAC CRA - Crane
MAH - Material handling CRU - Crusher
MAR - Marine CUT - Cutting,Shear,Saw
MET - Metal DRI - Drilling
MIN - Mining DRU - Drum
MUL - Multiple segments OEM ELE - Elevator
OFF - Offshore EXT - Extruder
OGA - Oil and Gas field FAN - Fan
PAP - Pulp and Paper FLA - Flat rolling
PEC - Petrochemical IND - Induction heating
PHA - Pharmaceutical KIL - Kiln
PRI - Printing MAC - Machinetool
POW - Power Plant MIX - Mixer,Stirrer
REC - Recreation PAC - Packaging machine
RUB - Rubber,Plastics PAP - Paper Machine
SAW - Sawmill POW - Power Electronics
TAD - Transmission and Distribution PRC - Processing line
TEX - Textile PRE - Press
WAT - Water PRI - Printing Machine
OTH - Other PRO - Profile rolling
NKN - Not Known PRP - Propulsion
PAR - Not known partner sales PUM - Pump
ROL - Roller table
Distribution Channels SKI - Skilift
SOL - Solar power
DSAL - Direct sales to end customer SPI - Spinning
SOEM - Serial OEM TES - Testbench
POEM - Project OEM THU - Thruster
LDIS - Electrical wholesaler WIC - Winch
TDIS - Technical distributor WID - Windmill
SINT - System integrator WIN - Winder
AHOU - EPCC and automation house NKN - Not Known
LCEN - Local ABB logistics centers OTH - Other
PBIN - Panel builders and installers PAR - Not known partner sales
AINT - ABB internal
Distribution Channel definitions:
Electrical Wholesalers (LDIS): Electrical Wholesalers/distributors has the ability to provide a wide
range of electrical products readily available from one location. Electrical Wholesalers/distributors
normally stocks leading brand name products, and the customer usually specifies the products
required from the catalogue. Electrical Wholesalers/distributors channels are cost driven and
normally use EDI-based ordering. This channel type includes Electrical wholesalers/distributors (e.g.
in US referred as electrical distributor), and also Catalogue houses.

Technical Distributor (TDIS): Technical product and service oriented channel. A technical
distributor has a good technical knowledge of the promoted product. Technical distributor offers
complementary products or services, which add value to the end customer. They do their business
locally, normally have a local stock and have a good working knowledge of local companies. This
channel type includes Drives Specialists, Motor repair shops, Power Transmission Distributors, but
partly also the ‘immaterial’ channels like contractors, specifiers, consultants, representatives and
agents.

System Integrator (SINT): Technical solution oriented channel. System Integrators are specialized
in providing turn key automation solutions. System Integrator has value adding complementary
products and services in the offering. Business is normally done locally, and System Integrator has
a good working knowledge of local companies and standards. System Integrators are focused to
certain e.g. process industries.

EPCC and Automation House (AHOU): Complete automation solution oriented channel.
Automation Houses are specialized in providing the complete factory automation solutions as turn
key projects. Automation house uses They use one or several sub contractors to carry out the
automation project. Offering covers all the industrial automation products and/or systems. They
operate normally in several countries. EPCC (Engineering, Procurement and construction
contractors) agrees to deliver the keys of a commissioned plant to the owner for an agreed amount

Serial OEM (SOEM): Machine manufacturers that are purchasing products on the regular basis
(=serial) according to the predefined delivery schedule. The scope of supply of ABB product is also
predefined and does not vary significantly from customer to customer.

Project OEM (POEM): Machine manufacturer that purchases the product according to the frame
agreements made with the supplier. Purchase occurs after the project and the customer is known.
The Scope of supply varies from customer to customer.

Panel Builders and Installers (PBIN): Companies taking care of electrical panel building and panel
customization as well as installation of electrical equipments. Often working as sub-suppliers for
other more solution orientated industrial channels. They have good knowledge about local
standards.

Direct sales to end customer (DSAL): Sales directly from ABB to the end customers without using
intermediaries ( = without using other channels in the list above) ABB Internal: Sales to other ABB
units (stock orders, end customer not known)

Local ABB Logistic Center (LCEN): Purchases to local ABB logistic center without knowledge
about the final channel to the market.

ABB Internal (AINT): Sales to other ABB business units and ABB companies
ACS800-01 Type Code Sheet 1 - 200 kW, Wall Mounted
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 1 Construction
01 = Wall mounted, IP21 (UL type 1), With control panel CDP312R, No EMC Channel
filter, Standard software, Cable lead through entry, Braking chopper in frame
sizes R2, R3 and R4 (only 690V), Boards without coating, One set of default
language documents

10…14 - Size
Frame Size R2 Frame Size R3 Frame Size R4 Frame Size R5 Frame Size R6
230V 0001 0002 0003 0006 0009 0011 0016 0020 0025 0030 0040 0050 0060 0070
0004 0005
400V 0003 0004 0005 0011 0016 0020 0025 0030 0040 0050 0060 0100 0120 0135
0006 0009 0075 0165 0205
500V 0004 0005 0006 0016 0020 0025 0030 0040 0050 0060 0070 0120 0140 0165
0009 0011 0105 0205 0255
690V 0011 0016 0050 0060 0070 0100 0120
0020 0025 0145 0175 0205
0030 0040

15…16 - Voltage Rating


2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01 L516 available only with Motion control
L502 Pulse encoder interface RTAC-01 and PMSM application softwares
L517 available only with standard control
L516 Resolver interface RRIA-01 and N651, N652, N654, N668, N677,
L517 Pulse encoder interface TTL RTAC-03 N685, N697 and N698 programs
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02 1 or 2 Digital extensions
L508 DDCS Communication 1 RDCO-01 1or 2 Analogue extensions, one for
I/O, the other only for motor temp.
measurement
Fieldbus 2 slots available for I/O options or Fieldbus adapters Communication board has always one
K451 DeviceNet adapter RDNA-01 dedicated slot.
Modbus adapter can be used with
K452 LONWorks adapter RLON-01 other Fieldbus adapter
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-01 - 1 3AFY64556568
ACS800-01 Type Code Sheet 1 - 200 kW, Wall Mounted
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control *) Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control

Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library

Control panel
0J400 No control panel

Protection class
B056 IP55 (UL type 12)

Construction
C131 Vibration dampers Only for R4, R5 and R6, not available with IP55 (B056)
C132 Marine Drive Coated boards included. Requires Vibration dampers (C131) which are not needed, if
installed in a cabinet. Type approval of classicication socities. Only ABS, BV and
Lloyd's for -0135-3, -0165-3, -0165-5, -0205-5, -0145-7, -0175-7 and -0205-7. ABS
and BV for -0075-3, -0105-5, -0205-3 and -0255-5
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frames R2 - R5 only
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, frame R6 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E202 not available for 690V units

Resistor braking
D150 Braking chopper Included as standard in frame sizes R2 , R3 and 690V
frame R4

ACS800-01 - 2 3AFY64556568
ACS800-01 Type Code Sheet 1 - 200 kW, Wall Mounted
Updated on 12 October 2011

Cabling
H358 Cable conduit entry (US & UK version)

Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Specialities
P901 Coated boards Not applicable with C132
P904 Extended warranty

ACS800-01 - 3 3AFY64556568
ACS800-02 Type Code Sheet 90 - 500 kW, Free standing
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 2 Construction
02 = Free standing, 6 pulse diode bridge, IP21 (UL type 1), With control Channel
panel CDP312R, No EMC filter, Standard software, Bottom entry and exit of
cables, Cable lead through entry, Boards without coating, One set of default
language documents

10…14 - Size
Frame Size R7 Frame Size R8
230V 0080 0100 0140 0170 0210
0120 0230 0260 0300
400V 0140 0170 0260 0320 0400
0210 0440 0490
500V 0170 0210 0320 0400 0440
0260 0490 0550 0610
690V 0140 0170 0320 0400 0440
0210 0260 0490 0550 0610

15…16 - Voltage Rating


2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01 L516 available only with Motion
L502 Pulse encoder interface RTAC-01 control and PMSM control
L516 Resolver interface RRIA-01 L517 available only with standard
L517 Pulse encoder interface TTL RTAC-03 control and N651, N652, N654,
N668, N677, N685, N697 and N698
L503 DDCS Communication 3 RDCO-03 programs
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01

Fieldbus 2 slots available for I/O options or Fieldbus adapters


K451 DeviceNet adapter RDNA-01 1 or 2 Digital extensions
1or 2 Analogue extensions, one for I/O,
K452 LONWorks adapter RLON-01
the other only for motor temp.
K454 Profibus-DP adapter RPBA-01 measurement
Communication board has always one
K457 CANOpen adapter RCAN-01
dedicated slot.
K458 Modbus adapter RMBA-01 Modbus adapter can be used with other
Fieldbus adapter
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-02 - 1 3AFY64556568
ACS800-02 Type Code Sheet 90 - 500 kW, Free standing
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter Control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library

Control panel
0J400 No control panel

Filters
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E208 Common mode filter E202 not available for 690V units neither for R8 frame
size
Resistor braking
D150 Braking chopper

Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Specialities
P901 Coated boards
P904 Extended warranty

ACS800-02 - 2 3AFY64556568
ACS800-04 Type Code Sheet 1 - 200 kW, Drive module
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 4 Construction
04 = Module, IP20 (UL Open type),No control panel, No EMC filter, Channel
Standard application software, Braking chopper in frame sizes R2, R3 and
R4 (only 690V), Boards without coating, One set of default language
documents

10…14 - Size
Frame Size R2 Frame Size R3 Frame Size R4 Frame Size R5 Frame Size R6
230V 0001 0002 0003 0006 0009 0011 0016 0020 0025 0030 0040 0050 0060 0070
0004 0005
400V 0003 0004 0005 0011 0016 0020 0025 0030 0040 0050 0060 0100 0120 0135
0006 0009 0023 0035 0075 0165 0205
500V 0004 0005 0006 0016 0020 0025 0030 0040 0050 0060 0070 0120 0140 0165
0009 0011 0028 0045 0105 0205 0255
690V 0011 0016 0050 0060 0070 0100 0120
0020 0025 0145 0175 0205
0030 0040

15…16 - Voltage Rating


2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L516 available only with Motion control and
L501 Digital I/O extension RDIO-01 PMSM control
L517 available only with standard application
L502 Pulse encoder interface RTAC-01
program and N651, N652, N654, N668,
L516 Resolver interface RRIA-01 N677, N685, N697 and N698 programs
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03 1 or 2 Digital extensions
1or 2 Analogue extensions, one for I/O, the
L509 DDCS Communication 2 RDCO-02 other only for motor temp. measurement
L508 DDCS Communication 1 RDCO-01 With motion control sw it is possible to have
1 or 2 pulse encoder/resolver interfaces
Fieldbus 2 slots available for I/O options or Fieldbus adapters Communication board has always one
dedicated slot.
K451 DeviceNet adapter RDNA-01 Modbus adapter can be used with other
K452 LONWorks adapter RLON-01 Fieldbus adapter

K454 Profibus-DP adapter RPBA-01


K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-04 (R2-R6) - 1 3AFY64556568


ACS800-04 Type Code Sheet 1 - 200 kW, Drive module
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control

Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
Control panel
J400 CDP312R control panel in module (in R2 - R4 includes also the J414 holder)
J414 Control panel holder for frame sizes R2 - R4 (not to be used with J400 option)
Construction
C132 Marine Drive Coated boards included. Type approval of classicication socities. Only ABS, BV and
Lloyd's for -0135-3, -0165-3, -0165-5, -0205-5, -0145-7, -0175-7 and -0205-7. ABS and
BV for -0075-3, -0105-5, -0205-3 and -0255-5
C135 Flange mounting C135: Flange mounting plate ready assembled. Heat sink side IP55, front
side IP20.
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frames R2 - R5 only
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, frame R6 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E202 not available for 690V units
Resistor braking
D150 Braking chopper Included as standard in frame sizes R2 , R3 and 690V
frame R4
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.

ACS800-04 (R2-R6) - 2 3AFY64556568


ACS800-04 Type Code Sheet 1 - 200 kW, Drive module
Updated on 12 October 2011
Documentation language
0R715 No documentation +0R715: Module is delivered without manuals. This needs to be
approved by customer.
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Specialities
P901 Coated boards Not applicable with C132
P904 Extended warranty

ACS800-04 (R2-R6) - 3 3AFY64556568


ACS800-04 Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 4 Construction
04 = Drive module, 6 pulse diode bridge, IP00 (UL Open type), Top entry of Channel
cables, side exit, RDCU motor control and I/O unit, No control panel, No
EMC filter, Standard software, Boards without coating, Bookshelf pedestal
with output busbars for motor, Bars for floor and wall fixing, One set of default
language documents

10…14 - Size
Frame Size R7 Frame Size R8
230V 0080 0100 0140 0170 0210
0120 0230 0260 0300
400V 0140 0170 0260 0320 0400
0210 0440 0490
500V 0170 0210 0320 0400 0440
0260 0490 0550 0610
690V 0140 0170 0320 0400 0440
0210 0260 0490 0550 0610

15…16 - Voltage Rating


2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01 L516 available only with Motion control
L501 Digital I/O extension RDIO-01 and PMSM control
L517 available only with standard
L502 Pulse encoder interface RTAC-01 application program and N651, N652,
L516 Resolver interface RRIA-01 N654, N668, N677, N685, N697 and
N698 programs
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03 1 or 2 Digital extensions
L509 DDCS Communication 2 RDCO-02 1or 2 Analogue extensions, one for I/O,
the other only for motor temp.
L508 DDCS Communication 1 RDCO-01 measurement
With motion control sw it is possible to
Fieldbus 2 slots available for I/O options or Fieldbus adapters have 1 or 2 pulse encoder/resolver
interfaces
K451 DeviceNet adapter RDNA-01 Communication board has always one
K452 LONWorks adapter RLON-01 dedicated slot.
Modbus adapter can be used with other
K454 Profibus-DP adapter RPBA-01 Fieldbus adapter
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-04(R7-R8) - 1 3AFY64556568
ACS800-04 Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
Program
N687 Pump control
Master follower includes optic fibres, requires DDCS
N651 Master/follower control
communication (add L503, L509 or L508 to code)
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control

Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
Control panel
J400 CDP 312R control panel (incl. 3 m control panel cable)
J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)
J413 RPMP-21 control panel mounting platform ("pocket" model to be mounted inside
the enclosure without control panel)
Filters
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network
E208 Common mode filter

Resistor braking
D150 Braking chopper (Including output busbar kit for braking chopper and DC unless +0H354 has been
selected)
Pedestal
0H354 No pedestal

ACS800-04(R7-R8) - 2 3AFY64556568
ACS800-04 Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950

Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
Documentation language
0R715 No documentation +0R715: Module is delivered without manuals. This
R700 English needs to be approved by customer.

R701 German Delivered set may include manuals in English


R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P901 Coated boards

P904 Extended warranty

ACS800-04(R7-R8) - 3 3AFY64556568
ACS800-04M Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 4 M Construction
04M = Modular drive module, 6 pulse diode bridge, IP00 (UL Open type), Top Channel
entry of cables, exit requires pedestal, RDCU motor control and I/O unit, No
control panel, No EMC filter, Standard software, Boards without coating, No
pedestal, No output busbars, One set of default language documents,
Pedestal & mechanical accessories delivered as loose parts

10…14 - Size
Frame Size R7 Frame Size R8
230V 0080 0100 0140 0170 0210
0120 0230 0260 0300
400V 0140 0170 0260 0320 0400
0210 0440 0490
500V 0170 0210 0320 0400 0440
0260 0490 0550 0610
690V 0140 0170 0320 0400 0440
0210 0260 0490 0550 0610

15…16 - Voltage Rating


2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters

L500 Analogue I/O extension RAIO-01 L516 available only with Motion control and
PMSM control
L501 Digital I/O extension RDIO-01 L517 available only with standard
L502 Pulse encoder interface RTAC-01 application program and N651, N652,
N654, N668, N677, N685, N697 and N698
L516 Resolver interface RRIA-01 programs
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03 1 or 2 Digital extensions
1or 2 Analogue extensions, one for I/O,
L509 DDCS Communication 2 RDCO-02 the other only for motor temp.
L508 DDCS Communication 1 RDCO-01 measurement
With motion control sw it is possible to
Fieldbus 2 slots available for I/O options or Fieldbus adapters have 1 or 2 pulse encoder/resolver
interfaces
K451 DeviceNet adapter RDNA-01
Communication board has always one
K452 LONWorks adapter RLON-01 dedicated slot.
Modbus adapter can be used with other
K454 Profibus-DP adapter RPBA-01
Fieldbus adapter
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-04M - 1 3AFY64556568
ACS800-04M Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library

Control panel
J400 CDP 312R control panel (incl. 3 m control panel cable)

J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)
J413 RPMP-21 control panel mounting platform ("pocket" model to be mounted inside the enclosure
without control panel)
Filters
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E202 not available for 690V units
E208 Common mode filter
Resistor braking
D150 Braking chopper (if +H354 or +H360 are selected, select also +H356)

Pedestal, pedestal accessories


H352 Bottom exit kit (available only for R7; wall mounting; includes DC and braking chopper busbars;
alternatives H354 and H360)
H354 Bookshelf pedestal (alternatives H352 and H360)
H360 Flat type ("side against wall") mounting pedestal (alternatives H352 and H354)
H356 Pedestal busbar kit for DC and braking chopper outputs (requires +H354 or +H360)
H355 Vertical busbars for motor output cable connection (incl. also supports for busbars). Requires +H354
or +H360.
H362 Vertical busbars for DC and braking chopper output cable connection. Requires pedestal +H354 or
+H360 and DC busbar kit +H356.
H363 Kit for DC and brake outputs on different sides (one long horisontal pedestal busbar, one extra
vertical busbar, one extra support for vertical busbars). Requires +H354 AND +H356.

ACS800-04M - 2 3AFY64556568
ACS800-04M Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.

B060 IP20 shroud. Available only for R7 frame size bottom exit version (+H352) and R8 frame size
bookshelf version with vertical busbars (+H354 +H355).
Documentation language
0R715 No documentation +0R715: Module is delivered without manuals. This
needs to be approved by customer.
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P901 Coated boards
P904 Extended warranty

ACS800-04M - 3 3AFY64556568
ACS800-U1 Type Code Sheet 1 - 200 HP, Wall Mounted
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - U 1 Construction
U1 = Wall mounted (USA), UL type1 (IP21), With control panel CDP312R, No Channel
EMC filter, Standard software (US), Cable conduit entry, Braking chopper in
frame sizes R2, R3 and R4 (only 600V), Boards without coating, One set of
default language documents

10…14 - Size
Frame Size R2 Frame Size R3 Frame Size R4 Frame Size R5 Frame Size R6
230V 0002 0003 0004 0006 0009 0011 0016 0020 0025 0030 0040 0050 0060 0070

500V 0004 0005 0006 0016 0020 0025 0030 0040 0050 0060 0070 0120 0140 0205
0009 0011 0105
690V 0011 0016 0050 0060 0070 0100 0120
(600V) 0020 0025 0145 0175 0205
0030 0040

15…16 - Voltage Rating


2 = 230 V 5 = 500 V 7 = 690 V (600V)
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01 L516 available only with Motion control
L501 Digital I/O extension RDIO-01 and PMSM control
L517 available only with standard
L502 Pulse encoder interface RTAC-01
application program and N651, N652,
L516 Resolver interface RRIA-01 N654, N668, N677, N685, N697 and
N698 programs
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02
1 or 2 Digital extensions
L508 DDCS Communication 1 RDCO-01 1or 2 Analogue extensions, one for I/O,
the other only for motor temp.
Fieldbus measurement
Communication board has always one
K451 DeviceNet adapter RDNA-01 dedicated slot.
K452 LONWorks adapter RLON-01 Modbus adapter can be used with other
Fieldbus adapter
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-U1 - 1 3AFY64556568
ACS800-U1 Type Code Sheet 1 - 150 HP, Wall Mounted
Updated on 12 October 2011
Program
N687 Pump control
Master follower includes optic fibres, requires DDCS
N651 Master/follower control communication (add L503, L509 or L508 to code)
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control Software compatibility with different option modules must be
N685 Motion control checked from ACS800 software compatibility document (doc
no. 3AFE64638211) in ABB Library
N697 Crane control
N698 Winch control
N678 Test bench control

Control panel
0J400 No control panel

Protection class
B056 IP55 (UL type 12)

Construction
C131 Vibration dampers Only for R4, R5 and R6, not available with UL type 12 (B056)
C132 Marine Drive Coated boards included. Requires Vibration dampers (C131) which are not needed, if
installed in a cabinet. Type approval of classicication socities. Only ABS, BV and Lloyd's
for -0205-5, -0145-7, -0175-7 and -0205-7
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frames R2 - R5 only
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, frame R6 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network

Resistor braking E202 not available for 690V units


D150 Braking chopper Included as standard in frame sizes R2 , R3 and
690V (600V) frame R4
Cabling
H357 Cable lead through entry (European)

ACS800-U1 - 2 3AFY64556568
ACS800-U1 Type Code Sheet 1 - 150 HP, Wall Mounted
Updated on 12 October 2011
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Specialities
P901 Coated boards Not applicable with C132
P904 Extended warranty

ACS800-U1 - 3 3AFY64556568
ACS800-U4 Type Code Sheet 150 - 600 HP, Drive module
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - U 4 Construction
U4 = Drive module (USA), 6 pulse diode bridge, UL Open type (IP00), Top entry Channel
of cables, side exit, RDCU motor control and I/O unit, No control panel, No EMC
filter, Standard software (US), Common mode filter in R8, Bookshelf pedestal
with output busbars for motor, Bars for floor and wall fixing, One set of default
language documents

10…14 - Size
Frame Size R7 Frame Size R8
230V 0080 0100 0140 0170 0210
0120 0230 0260 0300
500V 0170 0210 0270 0300 0320 0400
0260 0440 0490 0550 0610
690V 0140 0170 0320 0400 0440
0210 0260 0490 0550 0610

15…16 - Voltage Rating


2 = 230 V 5 = 500 V 7 = 690 V

Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01 L516 available only with Motion control and
PMSM control
L502 Pulse encoder interface RTAC-01 L517 available only with standard
L516 Resolver interface RRIA-01 application program and N651, N652,
N654, N668, N677, N685, N697 and N698
L517 Pulse encoder interface TTL RTAC-03 programs
L503 DDCS Communication 3 RDCO-03
1 or 2 Digital extensions
L509 DDCS Communication 2 RDCO-02
1or 2 Analogue extensions, one for I/O,
L508 DDCS Communication 1 RDCO-01 the other only for motor temp.
measurement
With motion control sw it is possible to
Fieldbus 2 slots available for I/O options or Fieldbus adapters
have 1 or 2 pulse encoder/resolver
K451 DeviceNet adapter RDNA-01 interfaces
Communication board has always one
K452 LONWorks adapter RLON-01
dedicated slot.
K454 Profibus-DP adapter RPBA-01 Modbus adapter can be used with
K457 CANOpen adapter RCAN-01 other Fieldbus adapter

K458 Modbus adapter RMBA-01


K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-U4 - 1 3AFY64556568
ACS800-U4 Type Code Sheet 150 - 600 HP, Drive module
Updated on 12 October 2011

Program
N687 Pump control
Master follower includes optic fibres, requires DDCS
N651 Master/follower control
communication (add L503, L509 or L508 to code)
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
Control panel
J400 CDP 312R control panel (incl. 3 m control panel cable)

J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)
J413 RPMP-21 control panel mounting platform ("pocket" model to be mounted inside
the enclosure without control panel)

Filters
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network
E208 Common mode filter (Only for R7)

Resistor braking
D150 Braking chopper (Including output busbar kit for braking chopper and DC unless +0H354 has been
selected)

Pedestal
0H354 No pedestal
Documentation language
0R715 No documentation +0R715: Module is delivered without manuals. This needs to be
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Specialities
P901 Coated boards
P904 Extended warranty
ACS800-U4 - 2 3AFY64556568
ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 7 Construction
07 = Cabinet built, IP21 (UL type1), Main switch fuse with aR fuses, 230 VAC Channel
control voltage, Control Panel CDP312R, No EMC filter, Standard software,
Bottom entry and exit of cables, Cable lead through entry, Boards without
coating, One set of default language documents

10…14 - Size

Frame Size R5 R6 R7 R8

400V 0075 0100 0120 0135 0260 0320 0400


0165 0205 0440 0490

500V 0105 0120 0140 0165 0320 0400 0440


0205 0255 0490 0550 0610

690V 0070 0100 0120 0320 0400 0440


0145 0175 0205 0260 0490 0550 0610

15…16 - Voltage Rating


3 = 400 V 5 = 500 V 7=690 V

Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01 L516 available only with PMSM
L502 Pulse encoder interface RTAC-01 control

L516 Resolver interface RRIA-01 Standard control supports


3 Digital extensions and
L503 DDCS Communication 3 RDCO-03
2 Analogue extensions, one for
L509 DDCS Communication 2 RDCO-02 I/O, the other only for motor temp.
measurement
L508 DDCS Communication 1 RDCO-01
Communication board has always
L504 Additional I/O-Terminal Block one dedicated slot.
Modbus adapter can be used with
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)
other Fieldbus adapter
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
L515 I/O extension adapter Requires DDCS communication I/O extension adapter
(requires DDCS
Fieldbus 2 slots available for I/O options or Fieldbus adapters communication), adds three
K451 DeviceNet adapter RDNA-01 slots for I/O extension and
Pulse encoder. Check
K452 LONWorks adapter RLON-01 compatibility with different
K454 Profibus-DP adapter RPBA-01 application softwares.
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
N-type fieldbus adapters require DDCS
K453 Interbus-S adapter NIBA-01 Communication board.
K456 AF100 adapter NAFA-01 Add L503 or L509 to code

ACS800-07(R5-R8) - 1 3AFY64556568
ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
Master follower includes optic fibres, requires DDCS
N651 Master/follower control
communication (add L503, L509 or L508 to code)
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter Control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library

Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R

Construction
C121 Marine construction Reinforced mechanics and fastening, door handels, self extinctive materials,
requires marking of conductors (G338-G342)
Not available with C129 or C134

C129 includes US type main switch fuse, Top entry and exit,115VAC control
C129 UL listed voltage, US Cable conduit entry, all components UL listed/recognized, max.
supply voltage 600 V

C134 CSA approved C134 Includes US/CSA type main switch fuse, Bottom entry and exit,
115VAC control voltage, US Cable conduit entry, all components UL/CSA
listed/recognized, max. supply voltage 600 V
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frame R5 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
Not for 690V, adds width by 200 mm for R7, 400 mm for R8
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, not for frame R5
E205 Du/dt limitation by choke
E208 is not available for R5 and R6 except 0135-3, 0165-3, 0205-
E208 Common mode filter 3, 0165-5, 0205-5, 0255-5, 0145-7, 0175-7 and 0205-7
E206 Sine output filter
E206 is not available for R5 and R6 except 0135-3, 0205-3, 0165-5, 0255-5,
0145-7 and 0175-7. Not available for 0260-7, 0490-7, 0610-7 or with C121,
C129 or E205. Available output current reduced for some types

ACS800-07(R5-R8) - 2 3AFY64556568
ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011

Resistor braking
D150 Braking chopper
D151 Braking resistor Braking resistor is not available as IP54, IP54R, or with C121, C129 or C134.
Available output current reduced for some types
Line fuses
F251 gG line fuses Replaces standard aR fuses, not available with C129
or C134
Line options
F250 Line contactor
Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H356 DC cable connection busbars
H358 Cable conduit entry (US & UK version) (Included with C129 or C134)
Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1 Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
G339 Wire marking class A2 Class A2, equipment and terminal block pin numbers printed on
G340 Wire marking class A3 conductors
Class A3, like A2 but marking by rings
G341 Wire marking class B1 Class B1, equipment and terminal block pin numbers and equipment
G342 Wire marking class C1 Ids marked by rings
Class C1, like B1 but remote end address is also marked

Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

ACS800-07(R5-R8) - 3 3AFY64556568
ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Starter for auxiliary Motor fan
M600 1...1,6 A (1 pc)
M601 1,6...2,5 A (1 pc)
M602 2,5...4 A (1 pc)
M603 4...6,3 A (1 pc)
M604 6,3...10 A (1 pc) M604 and M605 are not available for R5 or R6 except 0165-3,
M605 10...16 A (1 pc) 0205-3, 0205-5, 0255-5, 0175-7 and 0205-7

Safety features
Q950 Prevention of unexpected start up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker Q951 and Q952 require line
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *) contactor F250

Q963 Emergency Stop, Category 0 without opening main contactor/breaker


Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
* Category 1 E-stop reserves one RDIO module with Standard-, Master follower-, Centrifuge- or
Permanent Magnet Control Std application (add +L501 to code)
Specialities
P901 Coated boards
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)

ACS800-07(R5-R8) - 4 3AFY64556568
ACS800-U7 Type Code Sheet 150 - 600 HP, Cabinet built
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - U 7 Construction
U7 = Cabinet built(USA), UL type1 (IP21), US type main switch fuse, 115VAC control Channel
voltage, Control panel CDP312R, No EMC filter, Standard software (US), Top entry
and exit of cables, Cable conduit entry, Common mode filter in R8, One set of default
language documents

10…14 - Size

Frame Size R6 R7 R8
0270 0300
500V 0100 0120 0140 0320 0400 0440
0165 0205 0490 0550 0610
690V
(600V) 0070 0100 0120 0320 0400 0440
0145 0175 0205 0260 0490 0550 0610

15…16 - Voltage Rating


5 = 500 V 7=690 V (600V)

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01 L516 available only with PMSM
control
L516 Resolver interface RRIA-01
L503 DDCS Communication 3 RDCO-03 Standard control supports
3 Digital extensions and
L509 DDCS Communication 2 RDCO-02 2 Analogue extensions, one for I/O,
L508 DDCS Communication 1 RDCO-01 the other only for motor temp.
measurement
L504 Additional I/O-Terminal Block Communication board has always
L505 Thermistor Relay (1 or 2 pcs) (Not with L506) one dedicated slot.
Modbus adapter can be used with
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505) other Fieldbus adapter
L515 I/O extension adapter Requires DDCS communication
I/O extension adapter (requires DDCS
communication), adds three slots for
Fieldbus 2 slots available for I/O options or Fieldbus adapters
I/O extension and Pulse encoder.
K451 DeviceNet adapter RDNA-01 Check compatibility with different
application softwares.
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
N-type fieldbus adapters require
K453 Interbus-S adapter NIBA-01 DDCS Communication board.
K456 AF100 adapter NAFA-01 Add L503 or L509 to code

ACS800-U7(R6-R8) - 1 3AFY64556568
ACS800-U7 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011

Program
N687 Pump control
Master follower includes optic fibres, requires DDCS
N651 Master/follower control
communication (add L503, L509 or L508 to code)
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library

Protection class
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)

Filters
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
Not for 690V, adds width by 200 mm for R7, 400 mm for R8
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network
E205 Du/dt limitation by choke
E208 Common mode filter Standard in R8, not available for R5 and R6 except 0135-3, 0165-3, 0205-
3, 0165-5, 0205-5, 0255-5, 0145-7, 0175-7 and 0205-7
Resistor braking
D150 Braking chopper

Line options
F250 Line contactor

Cabling
H350 Bottom entry
H352 Bottom exit
H356 DC cable connection busbars
H357 Cable lead through entry (European)

Control voltage
G320 230 VAC Control Voltage

ACS800-U7(R6-R8) - 2 3AFY64556568
ACS800-U7 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Cabinet options
G300 Cabinet heater (External supply)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230 VAC or 115 VAC (UPS)
G330 Halogen free wiring and materials
G338 Wire marking class A1 Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
G339 Wire marking class A2 Class A2, equipment and terminal block pin numbers printed on
G340 Wire marking class A3 conductors
Class A3, like A2 but marking by rings
G341 Wire marking class B1 Class B1, equipment and terminal block pin numbers and equipment
G342 Wire marking class C1 Ids marked by rings
Class C1, like B1 but remote end address is also marked

Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Starter for auxiliary Motor fan
M600 1...1,6 A (1 pc)
M601 1,6...2,5 A (1 pc)
M602 2,5...4 A (1 pc)
M603 4...6,3 A (1 pc)
M604 6,3...10 A (1 pc)
M604 and M605 are not available for R5 or R6 except 0165-3, 0205
M605 10...16 A (1 pc) 3, 0205-5, 0255-5, 0175-7 and 0205-7

Safety features
Q950 Prevention of unexpected start up Not with Q968,Q963,Q964
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
Q951 and Q952 require
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *) line contactor (add F250 to
Q963 Emergency Stop, Category 0 without opening main contactor/breaker Not with Q950
Q964 Emergency Stop, Category 1 without opening main contactor/breaker *) Not with Q950
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
* Category 1 E-stop reserves one RDIO module with Standard-, Master follower-, Centrifuge- or
Permanent Magnet Control Std application (add +L501 to code)
Specialities
P901 Coated boards
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)

ACS800-U7(R6-R8) - 3 3AFY64556568
ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 0 7 Construction
07 = Cabinet built, IP21 (UL type1), Main Switch, 230 VAC control voltage, Control Channel
panel CDP312R, DDCS communication RDCO-03, EMC/RFI-filter 2nd Environment,
Du/dt limitation by choke, Common mode filter, Standard software, Bottom entry and
exit of cables, Cable lead through entry, Coated boards, One set of default language
documents

10…14 - Size

Frame Size 2xR8i 3xR8i 4xR8i 5xR8i 6xR8i


1xD4 2xD4 2xD4 3xD4 2xD4 3xD4 3xD4 3xD4 4xD4
400V 0610 0770 1230 1540 1850
0870
1030
500V 0760 0910 1540 1820 2310
1090
1210
690V 0750 1160 1500 2120 2320 2900 3190 3490
0870 1740
1060

15…16 - Voltage Rating


3 = 400 V 5 = 500 V 7=690 V

+V992 Equipped with the new DSU module

Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01 RDCO-02 and RDCO-01 will
L501 Digital I/O extension RDIO-01 replace standard RDCO-03

L502 Pulse encoder interface RTAC-01 L516 available only with PMSM
L516 Resolver interface RRIA-01
Standard control supports
L509 DDCS Communication 2 RDCO-02
3 Digital extensions and
L508 DDCS Communication 1 RDCO-01 2 Analogue extensions, one for
I/O, the other only for motor
L504 Additional I/O-Terminal Block
temp. measurement
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514) Communication board has
always one dedicated slot.
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)
Modbus adapter can be used
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
I/O extension adapter Requires DDCS communication
I/O extension adapter adds three
L515 I/O extension adapter Requires DDCS communication
slots for I/O extension and Pulse
encoder. Check compatibility with
Fieldbus 2 slots available for I/O options or Fieldbus adapters different application softwares.
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
N-type Fieldbus adapters require DDCS
K453 Interbus-S adapter NIBA-01 Communication board.
K456 AF100 adapter NAFA-01
ACS800-07(nxR8i) - 1 3AFY64556568
ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control Master follower includes optic fibres, requires DDCS
communication (add L509 or L508 to code)
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library

Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R

Construction
C121 Marine construction Reinforced mechanics and fastening, door handels, self extinctive materials,
requires marking of conductors (G338-G342)
Not available with C129 or C134
C129 UL listed C129 includes aR line fuses and Load switch, Top entry and exit, 115VAC
control voltage, US Cable conduit entry, all components UL
listed/recognized, max. supply voltage 600 V. 3xD4 and 4xD4 require 12-
pulse operation A004 or Air circuit breaker F255

C134 CSA approved C134 includes 115VAC control voltage, Bottom entry and exit, US Cable
conduit entry, all components UL/CSA listed/recognized, max. supply voltage
600 V
Filters
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E206 Sine output filter EMC filter only for 6-pulse 0610-3 and 0760-5, requires Load
switch, Line fuses+additional field. Add F253 and F260 to
Sine filter is not available with
code

Resistor braking (standard option only for 2xR8i)


D150 Braking chopper Braking resistor is not available as IP54, IP54R, or with C129 or C134.
D151 Braking resistor Marine construction C121 available only for 500V and 690V.
Available output current reduced for some types

ACS800-07(nxR8i) - 2 3AFY64556568
ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
Line options
F250 Line contactor F250 and F255 are alternative options

Line options, not available with C129 (UL listed)


F253+F260 aR Line fuses and Load switch, 6-pulse operation
A004+F253+F260 aR Line fuses and Load switch, 12-pulse operation
F253 includes additional field with input terminals. Load switches inside DSU modules are removed
Limitation with CSA C134: 6-pulse not available with 3xD4 or 4xD4

F255+F260 Air circuit breaker, aR Line fuses, 6-pulse operation


Air circuit breaker is alternative to Load switch F253, not available with 1xD4.
Load switches inside DSU modules are removed
F259 Earthing switch (only with F253 or F255, not available with C129/C134)
Line options available only with UL C129 (one of these required always with 3xD4 and 4xD4)
A004 12-pulse operation, includes two fields
F255 Air circuit breaker, 6-pulse operation
Air circuit breaker replaces Load switch, not available with 1xD4.

Cabling
H351 Top entry (included with C129) IP54 or IP54R with top entry require Load switch F253 or Air
circuit breaker F255. Dimensions may increase.
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H358 Cable conduit entry (US & UK version) (Included with C129 or C134)
H359 Common motor terminal cubicle

Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G317 Busbar Supply Conductors (6-pulse only, requires load switch F253 or air circuit breaker F255)
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1 Class A1, equipment pin numbers printed on conductors, conductors
G339 Wire marking class A2 to terminal blocks not marked
Class A2, equipment and terminal block pin numbers printed on
G340 Wire marking class A3 conductors
G341 Wire marking class B1 Class A3, like A2 but marking by rings
Class B1, equipment and terminal block pin numbers and equipment
G342 Wire marking class C1 Ids marked by rings
Class C1, like B1 but remote end address is also marked

ACS800-07(nxR8i) - 3 3AFY64556568
ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fan

M602 2,5...4 A (1,2 or 4 pcs)


M603 4...6,3 A (1,2 or 4 pcs)
M604 6,3...10 A (1,2 or 4 pcs)
M605 10...16 A (1 or 2 pcs)
M606 17…25 A (1 pc)

Safety features
Q950 Prevention of unexpected start up Not with Q968,Q963,Q964, Q971
Q951 and Q952 require
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
line contactor F250 or
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *) breaker F255

Q963 Emergency Stop, Category 0 without opening main contactor/breaker

Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)


Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q959 Red tripping push button for external breaker
Q971 ATEX certified safety function Only with L513 and L514, not with Q950

* Category 1 E-stop reserves one RDIO module with Standard-, Master follower-,
Centrifuge- or Permanent Magnet Control Std application (add +L501 to code)

Specialities
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)

ACS800-07(nxR8i) - 4 3AFY64556568
ACS800-11 Type Code Sheet 7.5 - 110 kW, Wall Mounted
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 1 1 Construction
11 = Wall mounted regenerative drive, IP21, With control panel CDP312R, Channel
RDCO-03, No EMC filter, Standard software, Cable lead through entry,
Boards with coating, One set of default language documents.

10…14 - Size
Frame Size R5 Frame Size R6
230V 0011 0016 0020 0040 0050
0025 0030 0060

400V 0016 0020 0025 0060 0070


0030 0040 0050 0100

500V 0020 0025 0030 0070 0100


0040 0050 0060 0120

690V 0060 0070


0100

15…16 - Voltage Rating


2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters


L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01 L516 available only with Motion control and
L516 Resolver interface RRIA-01 PMSM control
L517 Pulse encoder interface TTL RTAC-03
L509 DDCS Communication 2 RDCO-02 1 or 2 Digital extensions
L508 DDCS Communication 1 RDCO-01 1or 2 Analogue extensions, one for
I/O, the other only for motor temp.
Fieldbus 2 slots available for I/O options or Fieldbus adapters measurement
With motion control sw it is possible to
K451 DeviceNet adapter RDNA-01 have 1 or 2 pulse encoder/resolver
K452 LONWorks adapter RLON-01 interfaces
Communication board has always one
K454 Profibus-DP adapter RPBA-01 dedicated slot.
K457 CANOpen adapter RCAN-01 Modbus adapter can be used with
other Fieldbus adapter
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-11 - 1 3AFY64556568
ACS800-11 Type Code Sheet 7.5 - 110 kW, Wall Mounted
Updated on 12 October 2011

Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control

Software compatibility with different option modules must be checked from ACS800 software compatibility
(doc no. 3AFE64638211) in ABB Library.
Control panel
0J400 No control panel

Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E202 not available for 690V units
Cabling
H358 Cable conduit entry (US & UK version)

Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Specialities
P904 Extended warranty

ACS800-11 - 2 3AFY64556568
ACS800-U11 Type Code Sheet 10 - 125 HP, Wall Mounted
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - U 1 1 Construction
U11 = Wall mounted regenerative drive (USA), IP21, With control panel Channel
CDP312R, RDCO-03, No EMC filter, Standard software (US), Cable conduit
entry, Boards with coating, One set of default language documents.

10…14 - Size
Frame Size R5 Frame Size R6
230V 0011 0016 0020 0040 0050
0025 0030 0060

500V 0020 0025 0030 0070 0100


0040 0050 0060 0120

690V 0060 0070


(600V) 0100

15…16 - Voltage Rating


2 = 230 V 5 = 500 V 7 = 690 V (600V)

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters


L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 available only with Motion control and
L516 Resolver interface RRIA-01 PMSM control
L517 Pulse encoder interface TTL RTAC-03
L509 DDCS Communication 2 RDCO-02 1 or 2 Digital extensions
1or 2 Analogue extensions, one for
L508 DDCS Communication 1 RDCO-01 I/O, the other only for motor temp.
measurement
Fieldbus 2 slots available for I/O options or Fieldbus adapters With motion control sw it is possible to
have 1 or 2 pulse encoder/resolver
K451 DeviceNet adapter RDNA-01 interfaces
K452 LONWorks adapter RLON-01 Communication board has always one
dedicated slot.
K454 Profibus-DP adapter RPBA-01 Modbus adapter can be used with
K457 CANOpen adapter RCAN-01 other Fieldbus adapter
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-U11 - 1 3AFY64556568
ACS800-U11 Type Code Sheet 10 - 125 HP, Wall Mounted
Updated on 12 October 2011

Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control

Software compatibility with different option modules must be checked from ACS800 software compatibility
(doc no. 3AFE64638211) in ABB Library..
Control panel
0J400 No control panel

Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E202 not available for 690V units
Cabling
H357 Cable lead through entry (European)

Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.

Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Specialities
P904 Extended warranty

ACS800-U11 - 2 3AFY64556568
ACS800-31 Type Code Sheet 7.5 - 110 kW, Wall Mounted
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 3 1 Construction
31 = Wall mounted low harmonic drive, IP21, With control panel CDP312R, Channel
RDCO-03, No EMC filter, Standard software, Cable lead through entry,
Boards with coating, One set of default language documents.

10…14 - Size
Frame Size R5 Frame Size R6
230V 0011 0016 0020 0040 0050
0025 0030 0060

400V 0016 0020 0025 0060 0070


0030 0040 0050 0100

500V 0020 0025 0030 0070 0100


0040 0050 0060 0120

690V 0060 0070


0100

15…16 - Voltage Rating


2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters


L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01 L516 available only with PMSM
control
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01 1 or 2 Digital extensions
1or 2 Analogue extensions, one for
Fieldbus 2 slots available for I/O options or Fieldbus adapters I/O, the other only for motor temp.
K451 DeviceNet adapter RDNA-01 measurement
Communication board has always
K452 LONWorks adapter RLON-01
one dedicated slot.
K454 Profibus-DP adapter RPBA-01 Modbus adapter can be used with
K457 CANOpen adapter RCAN-01 other Fieldbus adapter
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-31 - 1 3AFY64556568
ACS800-31 Type Code Sheet 7.5 - 110 kW, Wall Mounted
Updated on 12 October 2011

Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control

Software compatibility with different option modules must be checked from ACS800 software compatibility
(doc no. 3AFE64638211) in ABB Library.
Control panel
0J400 No control panel

Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E202 not available for 690V units
Cabling
H358 Cable conduit entry (US & UK version)

Safety features
Q967 Safe torque off STO, without safety relay
Separate gate driver power supply board (ASTO) and connection wires included in the converter package.
Does not include e.g. safety relay.

Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Specialities
P904 Extended warranty

ACS800-31 - 2 3AFY64556568
ACS800-U31 Type Code Sheet 10 - 125 HP, Wall Mounted
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - U 3 1 Construction
U31 = Wall mounted low harmonic drive (USA), IP21, With control panel Channel
CDP312R, RDCO-03, No EMC filter, Standard software (US), Cable conduit
entry, Boards with coating, One set of default language documents.

10…14 - Size
Frame Size R5 Frame Size R6
230V 0011 0016 0020 0040 0050
0025 0030 0060

500V 0020 0025 0030 0070 0100


0040 0050 0060 0120

690V 0060 0070


(600V) 0100

15…16 - Voltage Rating


2 = 230 V 5 = 500 V 7 = 690 V (600V)

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters


L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01 L516 available only with PMSM
L509 DDCS Communication 2 RDCO-02 control
L508 DDCS Communication 1 RDCO-01 1 or 2 Digital extensions
1or 2 Analogue extensions, one for
Fieldbus 2 slots available for I/O options or Fieldbus adapters I/O, the other only for motor temp.
K451 DeviceNet adapter RDNA-01 measurement
Communication board has always
K452 LONWorks adapter RLON-01
one dedicated slot.
K454 Profibus-DP adapter RPBA-01 Modbus adapter can be used with
K457 CANOpen adapter RCAN-01 other Fieldbus adapter
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02

ACS800-U31 - 1 3AFY64556568
ACS800-U31 Type Code Sheet 10 - 125 HP, Wall Mounted
Updated on 12 October 2011

Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control

Software compatibility with different option modules must be checked from ACS800 software compatibility
(doc no. 3AFE64638211) in ABB Library.
Control panel
0J400 No control panel

Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E202 not available for 690V units
Cabling
H357 Cable lead through entry (European)

Safety features
Q967 Safe torque off STO, without safety relay
Separate gate driver power supply board (ASTO) and connection wires included in the converter package.
Does not include e.g. safety relay.

Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Specialities

ACS800-U31 - 2 3AFY64556568
P904 Extended warranty

ACS800-U31 - 3 3AFY64556568
ACS800-17 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 1 7 Construction
17 = Cabinet built regenerative drive, IP21 (UL type1), Main switch fuse with Channel
aR fuses, Line contactor (option for frame R6), 230 VAC control voltage,
RDCO-03, Control Panel CDP312R, EMC 2nd Environment (R6 no EMC
filter), Du/dt limitation by choke in 690V R8i, Common mode filter (not for R6),
Standard software, Bottom entry and exit of cables, Cable lead through entry,
Coated boards, One set of default language documents

10…14 - Size

Frame Size R6 R7i R8i

400V 0060 0070 0140 0170 0210 0260 0320


0100 0390 0490

500V 0070 0100 0170 0210 0260 0320 0400


0120 0460 0510 0580

690V 0060 0070 0160 0200 0260 0320 0400


0100 0440 0540

15…16 - Voltage Rating


3 = 400 V 5 = 500 V 7=690 V

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01
Standard control supports
L501 Digital I/O extension RDIO-01 3 Digital extensions and
2 Analogue extensions, one for
L502 Pulse encoder interface RTAC-01
I/O, the other only for motor
L516 Resolver interface RRIA-01 temp. measurement
L516 available only with PMSM control Communication board has
always one dedicated slot.
L509 DDCS Communication 2 RDCO-02
Modbus adapter can be used
L508 DDCS Communication 1 RDCO-01 with other Fieldbus adapter
L504 Additional I/O-Terminal Block
I/O extension adapter adds three
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514) slots for I/O extension and Pulse
encoder. Check compatibility
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)
with different control softwares.
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
L515 I/O extension adapter

Fieldbus 2 slots available for I/O options or Fieldbus adapters


K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02 N-type fieldbus adapters require DDCS
Communication board.
K453 Interbus-S adapter NIBA-01 RDCO-03 included by default, L509 is
K456 AF100 adapter NAFA-01 optional

ACS800-17 (R6-R8i) - 1 3AFY64556568


ACS800-17 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Software compatibility with different option modules must be checked from ACS800 software compatibility
(doc no. 3AFE64638211) in ABB Library.

Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R
Construction
C121 Marine construction Reinforced mechanics and fastening, door handels, self extinctive
materials, requires marking of conductors (G338-G342)
Not available with C129 or C134

C129 includes: US type main switch fuse, Supply frequency 60 Hz, Top
C129 UL listed entry and exit,115VAC control voltage, US Cable conduit entry, all
components UL listed/recognized, max. supply voltage 600 V.

C134 CSA approved C134 Includes: US/CSA type main switch fuse, Supply frequency 60 Hz,
115VAC control voltage, US Cable conduit entry, all components UL/CSA
listed/recognized, max. supply voltage 600 V
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, R6 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network, not available for 690V
E202 in frames R7i and R8i requires a common motor terminal cubicle, adds width by 300mm
(insert H359 to type code).
E205 Du/dt limitation by choke (included in 690V R8i)
E205 in frame R7i requires a common motor terminal cubicle, adds width by 300mm
(insert H359 to type code).

E206 Sine output filter


Not available for R6 or with C121 or C129. Available output current reduced
for some types

Line options
F250 Line contactor (only for R6, included in other types)
Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H356 DC cable connection busbars
H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)
H365 Cable conduit entry (US & UK version), brass 6 mm
H359 Common motor terminal cubicle Only with E202 in R7i/R8i or with E205 in R7i
ACS800-17 (R6-R8i) - 2 3AFY64556568
ACS800-17 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011

Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1 Class A1, equipment pin numbers printed on conductors, conductors
G339 Wire marking class A2 to terminal blocks not marked
Class A2, equipment and terminal block pin numbers printed on
G340 Wire marking class A3 conductors
G341 Wire marking class B1 Class A3, like A2 but marking by rings
Class B1, equipment and terminal block pin numbers and equipment
G342 Wire marking class C1 Ids marked by rings
Class C1, like B1 but remote end address is also marked

Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fan


M600 1...1,6 A (1 pc)
M601 1,6...2,5 A (1 pc)
M602 2,5...4 A (1 pc)
M603 4...6,3 A (1 pc)
M604 6,3...10 A (1 pc) (not for R6)
M605 10...16 A (1 pc) (not for R6)

Safety features
Q950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker Q951 and Q952 require
Q952 Emergency Stop, Category 1 with opening main contactor/breaker contactor F250 for R6

Q963 Emergency Stop, Category 0 without opening main contactor/breaker


Q964 Emergency Stop, Category 1 without opening main contactor/breaker
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
Category 1 e-stop reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or
Permanent Magnet Control Std applicatrion (add +L501 to code)
Specialities
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)

ACS800-17 (R6-R8i) - 3 3AFY64556568


ACS800-17 Type Code Sheet 500 - 2500 kW, Cabinet built
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 1 7 Construction
17 = Cabinet built regenerative drive, IP21 (UL type1), Air circuit breaker, aR fuses, 230 Channel
VAC control voltage, Control panel CDP312R, RDCO-03, EMC 2nd Environment, Du/dt
limitation by choke, Common mode filter, Standard software, Bottom entry and exit of
cables, Cable lead through entry, Coated boards, One set of default language
documents

10…14 - Size

Frame Size 2xR8i 3xR8i 4xR8i 6/5xR8i 6xR8i

400V 0640 0770 1070 1370 1810


0960

500V 0780 0870 1330 1640 2160


1140

690V 0790 0870 1330 1510 1980 2780 2940


1050

15…16 - Voltage Rating


3 = 400 V 5 = 500 V 7=690 V

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01 Standard control supports
L501 Digital I/O extension RDIO-01 3 Digital extensions and
2 Analogue extensions, one for
L502 Pulse encoder interface RTAC-01 I/O, the other only for motor temp.
L516 Resolver interface RRIA-01 measurement
Communication board has always
L516 available only with PMSM control one dedicated slot.
L509 DDCS Communication 2 RDCO-02 Modbus adapter can be used with
other Fieldbus adapter
L508 DDCS Communication 1 RDCO-01
L504 Additional I/O-Terminal Block I/O extension adapter adds three
slots for I/O extension and Pulse
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514) encoder. Check compatibility with
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514) different application softwares.
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
L515 I/O extension adapter

Fieldbus 2 slots available for I/O options or Fieldbus adapters


K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
N-type fieldbus adapters require DDCS
K466 Ethernet adapter(EIP,MB/TCP) RETA-01 Communication board.
RDCO-03 included by default, L509 is
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
optional
K453 Interbus-S adapter NIBA-01
K456 AF100 adapter NAFA-01

ACS800-17 (nxR8i) - 1 3AFY64556568


ACS800-17 Type Code Sheet 500 - 2500 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control

Software compatibility with different option modules must be checked from ACS800 software compatibility (doc
no. 3AFE64638211) in ABB Library.
Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R

Construction
C121 Marine construction Reinforced mechanics and fastening, door handels, self extinctive materials,
requires marking of conductors (G338-G342)
Not available with C129 or C134

C129 includes: Top entry and exit, Supply frequency 60 Hz, 115VAC control
C129 UL listed voltage, US Cable conduit entry, all components UL/CSA listed/recognized,
max. supply voltage 600 V

C134 CSA approved C134 includes: 115VAC control voltage, US Cable conduit entry, Supply
frequency 60Hz, all components UL/CSA listed/recognized, max. supply
voltage 600 V
Filters
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E206 Sine output filter EMC filter only for 0640-3, 0770-3, 0780-5
Sine filter is not available with
C121 or C129. and 0870-5
Line options
F259 Earthing switch (not available with C129)

Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)
H365 Cable conduit entry (US & UK version), brass 6 mm
H359 Common motor terminal cubicle

ACS800-17 (nxR8i) - 2 3AFY64556568


ACS800-17 Type Code Sheet 500 - 2500 kW, Cabinet built
Updated on 12 October 2011

Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G317 Busbar Supply Conductors
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1 Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
G339 Wire marking class A2
Class A2, equipment and terminal block pin numbers printed on
G340 Wire marking class A3 conductors
Class A3, like A2 but marking by rings
G341 Wire marking class B1 Class B1, equipment and terminal block pin numbers and equipment
G342 Wire marking class C1 Ids marked by rings
Class C1, like B1 but remote end address is also marked

Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fan


M602 2,5...4 A (1,2 or 4 pcs)
M603 4...6,3 A (1,2 or 4 pcs)
M604 6,3...10 A (1,2 or 4 pcs)
M605 10...16 A (1 or 2 pcs)
M606 17…25 A (1 pc)

Safety features
Q950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)
Q963 Emergency Stop, Category 0 without opening main contactor/breaker
Q964 Emergency Stop, Category 1 without opening main contactor/breaker*)
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
* Category 1 reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or Permanent Magnet
Control Std applicatrion (add +L501 to code)

Specialities
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)

ACS800-17 (nxR8i) - 3 3AFY64556568


ACS800-37 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 3 7 Construction
37 = Cabinet built low harmonic drive, IP21 (UL type1), Main switch fuse with Channel
aR fuses, Line contactor (option for frame R6), 230 VAC control voltage,
RDCO-03, Control Panel CDP312R, EMC 2nd Environment (R6 no EMC
filter), Du/dt limitation by choke in 690V R8i, Common mode filter (not for R6),
Standard software, Bottom entry and exit of cables, Cable lead through entry,
Coated boards, One set of default language documents

10…14 - Size

Frame Size R6 R7i R8i

400V 0060 0070 0140 0170 0210 0260 0320


0100 0390 0510

500V 0070 0100 0170 0210 0260 0320 0400


0120 0460 0510 0610

690V 0060 0070 0170 0210 0260 0320 0400


0100 0440 0540

15…16 - Voltage Rating


3 = 400 V 5 = 500 V 7=690 V

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01 Standard control supports
L501 Digital I/O extension RDIO-01 3 Digital extensions and
2 Analogue extensions, one for
L502 Pulse encoder interface RTAC-01 I/O, the other only for motor
L516 Resolver interface RRIA-01 temp. measurement
Communication board has
L516 available only with PMSM control always one dedicated slot.
L509 DDCS Communication 2 RDCO-02 Modbus adapter can be used
L508 DDCS Communication 1 RDCO-01 with other Fieldbus adapter

L504 Additional I/O-Terminal Block I/O extension adapter adds


L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514) three slots for I/O extension and
Pulse encoder. Check
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514) compatibility with different
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs) application softwares.
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
L515 I/O extension adapter

Fieldbus 2 slots available for I/O options or Fieldbus adapters


K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02 N-type fieldbus adapters require
DDCS Communication board.
K453 Interbus-S adapter NIBA-01 RDCO-03 included by default, L509
K456 AF100 adapter NAFA-01 is optional

ACS800-37 (R6-R8i) - 1 3AFY64556568


ACS800-37 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter Control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control Software compatibility with different option modules must be checked
N678 Test bench control from ACS800 software compatibility (doc no. 3AFE64638211) in ABB
Library.
Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R
Construction
C121 Marine construction Reinforced mechanics and fastening, door handels, self extinctive
materials, requires marking of conductors (G338-G342)
Not available with C129 or C134

C129 UL listed C129 includes: US type main switch fuse, Supply frequency 60 Hz, Top
entry and exit,115VAC control voltage, US Cable conduit entry, all

C134 CSA approved C134 Includes: US/CSA type main switch fuse, Supply frequency 60 Hz
115VAC control voltage, US Cable conduit entry, all components UL/CSA

Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, R6 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network, not available for 690V
E202 in frames R7i and R8i requires a common motor terminal cubicle, adds width by 300mm
(insert H359 to type code).

E205 Du/dt limitation by choke (included in 690V R8i)


E205 in frame R7i requires a common motor terminal cubicle, adds width by 300mm
(insert H359 to type code).

E206 Sine output filter Not available for R6, or with C121 , C129, D150 or D151. Available output
current reduced for some types
Resistor braking
D150 Braking chopper Braking resistor is not available as IP54, IP54R, or with C121 , C129 or
D151 Braking resistor E206. Available output current reduced for some types
Line options
F250 Line contactor (only for R6, included in other types)
Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H356 DC cable connection busbars
H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)
H365 Cable conduit entry (US & UK version), brass 6 mm
H359 Common motor terminal cubicle Only with E202 in R7i/R8i or with E205 in R7i
ACS800-37 (R6-R8i) - 2 3AFY64556568
ACS800-37 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011

Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1 Class A1, equipment pin numbers printed on conductors, conductors
G339 Wire marking class A2 to terminal blocks not marked
Class A2, equipment and terminal block pin numbers printed on
G340 Wire marking class A3 conductors
G341 Wire marking class B1 Class A3, like A2 but marking by rings
Class B1, equipment and terminal block pin numbers and equipment
G342 Wire marking class C1 Ids marked by rings
Class C1, like B1 but remote end address is also marked

Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fan


M600 1...1,6 A (1 pc)
M601 1,6...2,5 A (1 pc)
M602 2,5...4 A (1 pc)
M603 4...6,3 A (1 pc)
M604 6,3...10 A (1 pc) (not for R6)
M605 10...16 A (1 pc) (not for R6)

Safety features
Q950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker Q951 and Q952 require
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *) contactor F250 for R6
Q963 Emergency Stop, Category 0 without opening main contactor/breaker
Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
* Category 1 reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or Permanent
Magnet Control Std applicatrion (add +L501 to code)
Specialities
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)

ACS800-37 (R6-R8i) - 3 3AFY64556568


ACS800-37 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
1…6 A C S 8 0 0 Product Series Industry Application

7…9 - 3 7 Construction
37 = Cabinet built low harmonic drive, IP21 (UL type1), Air circuit breaker, aR fuses, 230 Channel
VAC control voltage, Control panel CDP312R, RDCO-03, EMC 2nd Environment, Du/dt
limitation by choke, Common mode filter, Standard software, Bottom entry and exit of
cables, Cable lead through entry, Coated boards, One set of default language
documents

10…14 - Size

Frame Size 2xR8i 3xR8i 4xR8i 6/5xR8i 6xR8i

400V 0640 0770 1070 1430 1810


0960

500V 0780 0870 1330 1820 2200


1160

690V 0790 0870 1330 1510 2320 2780 3310


1160

15…16 - Voltage Rating


3 = 400 V 5 = 500 V 7=690 V

Option codes

I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01 Standard control supports
L501 Digital I/O extension RDIO-01 3 Digital extensions and
2 Analogue extensions, one for I/O,
L502 Pulse encoder interface RTAC-01 the other only for motor temp.
L516 Resolver interface RRIA-01 measurement
Communication board has always
L516 available only with PMSM control one dedicated slot.
L509 DDCS Communication 2 RDCO-02 Modbus adapter can be used with
other Fieldbus adapter
L508 DDCS Communication 1 RDCO-01
L504 Additional I/O-Terminal Block I/O extension adapter adds three
slots for I/O extension and Pulse
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)
encoder. Check compatibility with
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514) different application softwares.
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
L515 I/O extension adapter

Fieldbus 2 slots available for I/O options or Fieldbus adapters


K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02 N-type fieldbus adapters require
DDCS Communication board.
K453 Interbus-S adapter NIBA-01 RDCO-03 included by default, L509
K456 AF100 adapter NAFA-01 is optional

ACS800-37 (nxR8i) - 1 3AFY64556568


ACS800-37 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control

Program compatibility with different option modules must be checked from ACS800 software compatibility (doc
no. 3AFE64638211) in ABB Library.
Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R

Construction
C121 Marine construction Reinforced mechanics and fastening, door handels, self extinctive materials,
requires marking of conductors (G338-G342)
Not available with C129 or C134

C129 includes: Top entry and exit,115VAC control voltage, Supply frequency
C129 UL listed 60 Hz, US Cable conduit entry, all components UL/CSA listed/recognized,
max. supply voltage 600 V

C134 includes: 115VAC control voltage, US Cable conduit entry, Supply


C134 CSA approved frequency 60Hz, all components UL/CSA listed/recognized, max. supply
voltage 600 V
Filters
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E206 Sine output filter Sine filter is not available with EMC filter only for 0640-3, 0770-3, 0780-5
. and 0870-5

Resistor braking (standard option only for 2xR8i)


D150 Braking chopper
Braking resistor is not available as IP54, IP54R, with C129 or E206. Marine
D151 Braking resistor construction C121 available only for 500V and 690V.
Available output current reduced for some types
Line options
F259 Earthing switch (not available with C129)

Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)
H365 Cable conduit entry (US & UK version), brass 6 mm
H359 Common motor terminal cubicle
ACS800-37 (nxR8i) - 2 3AFY64556568
ACS800-37 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011

Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)

Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G317 Busbar Supply Conductors
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1 Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
G339 Wire marking class A2
Class A2, equipment and terminal block pin numbers printed on
G340 Wire marking class A3 conductors
Class A3, like A2 but marking by rings
G341 Wire marking class B1 Class B1, equipment and terminal block pin numbers and equipment
G342 Wire marking class C1 Ids marked by rings
Class C1, like B1 but remote end address is also marked

Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English

Starter for auxiliary Motor fan


M602 2,5...4 A (1,2 or 4 pcs)
M603 4...6,3 A (1,2 or 4 pcs)
M604 6,3...10 A (1,2 or 4 pcs)
M605 10...16 A (1 or 2 pcs)
M606 17…25 A (1 pc)

Safety features
Q950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)
Q963 Emergency Stop, Category 0 without opening main contactor/breaker
Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
* Category 1 reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or
Permanent Magnet Control Std applicatrion (add +L501 to code)
Specialities
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)

ACS800-37 (nxR8i) - 3 3AFY64556568


ABB Oy, Drives Technical Appendix for ACS800-x7
Revision:

ABB Company: Date: Page:


Your ref: End Customer:
Contact Person: Project Title:
Phone / Fax: Application:
eMail: Customer ref:

ACS800-07/-17/-37 Non-Standard Options in ACS 800 Price List


All options below needs also +P902 option
No engineering needed only standard as build drawings with customer specific drawing title blocks
(specify above project title, end customer and customer ref) no additional engineering
Document approval not needed, send them just for information before starting the production
Supply freq. for options 60Hz (default 50Hz) Signal lamps (specify colours pcs:
and function)
Power for RMIO board from internal Additional relays (specify type pcs:
230 VAC (Only for ACS800-07, R6-R8) and function)
Ammeter AI/O galvanic isolation for mA signal (1-4 pcs)
Voltmeter
Running hour meter Customer specific cable lead through (gland) plate
(specify below)
+P913 Special colour RAL Empty cabinet (specify on separate page)

NAMUR I/O, requires also +H366 Internal parallel connection busbars for 2xR8i and 3xR8i
+F250+Q951+L501+K454+P902
+C164 Plinth for the cabinet, height: 100mm
+C130 Air outlet channel (IPxxR) 200mm
+D150 Braking chopper (NBRA-6X9) (3-6xR8i)
+C128 Air inlet through bottom +D151 Braking resistor (SAFUR) (3-6xR8i)
3 phase braking chopper (ACS800-607)
Bypass, specify on page "Bypass" (specify the braking power)

+Q965 SLS with encoder


+Q966 SLS without encoder

Design by the old reference project. FIDRI No.: or Purchace No.:


Detailed description of desired function:

Other information
Customer/Local ABB delivers components to FIDRI
and sends the Data Sheets of the components with Technical Appendix. (min. 9weeks before loading date)
Customer/Local ABB delivers predesign documentation
Special door labels (specify using separate appendix)
Preliminary documentation required: Delivery time must be agreed with FIDRI Area Manager
Dimension drawings By Lotus Notes
Control circuit diagrams

Delivery of final documentation By Lotus Notes


Company
Attention Phone
Country e-mail
Address TechnApp - 1 3AFY64556568
ABB Oy, Drives Technical Appendix for ACS800-x7 with Bypass
Revision:

ABB Company: Date: Page:


Your ref: End Customer:
Contact Person: Project Title:
Phone / Fax: Application:
eMail: Customer ref:

ACS800-07/-17/-37 Engineered DOL Bypass

Please specify nominal motor power (P), full load current (FLC) in the direct on line (DOL) supply:

Nominal power: kW

Full load current: A

Network voltage: VAC

Options required also:

+G307 (Terminals for External Control Voltage)

+P902 (Customized)

Protections for the motor included in the SACE Tmax PR222MP as standard

Adjustable protection against overload, rotor block, short-circuit and missing phase or unbalanced

Ground leakage protection in earthed networks as an option (please select if required).

Ground leakage monitoring by sum current transformer and monitoring relay

Change over control

Manual Local

External

Automatic Synchronization

Please note:

Engineered DOL bypass not for +C129 (UL listed) ; +C134 (CSA approved) nor +E202 (EMC/RFI-filter)

Additional information:
ABB Oy, Drives Technical Appendix for ACS800-x7
Empty cabinets

ABB Company: Date: Page:


Your ref: End Customer:
Contact Person: Project Title:
Phone / Fax: Application:
Email:

Number of empty cabinets

Colour
RAL 7035 (std.) Special

Mounting

Mounted to the frequency converter Stand-alone

On the left side of the frequency converter


(front view)

On the right side of the frequency converter


(front view)

Enclosure

IP21 Normal door with air inlet openings

IP22 Normal door with control panel mounting platform

IP42 Blank door and roof & no air inlet openings

IP54 (no cooling fans)

IP54R (outlet connection to ventilation channel)

Cable lead through (for empty cabinet)


Standard cable lead through No need for cable lead through
(sealed roof and bottom)

Top Cable gland plate 6mm brass (undrilled)


Cable gland plate 3mm steel (undrilled)
Bottom Cable gland plate 3mm aluminium (undrilled)

Cabinet width
300mm 700 mm

400 mm 800 mm

600 mm 1000 mm

Assembly plates on both sides and on back as standard

Additional information:

TechnApp - 1 3AFY64556568
ABB Oy, Drives Technical Appendix for ACS800-x7
Labels

ABB Company: Date: Page:


Your ref: End Customer:
Contact Person: Project Title:
Phone / Fax: Application:
eMail:

Labels described in this specification are not included as standard only with option +P902.
Models A and B are factory preferred types. If location of labels is not specified, standard location will
be used. Specify location using the lay-out drawing.

Rivet mounting Customer delivers own door labels

Stick-on label Customer defined labels


Specify:
label size
Factory preferred types
character height
A Main reference label
size 140 x 33 mm characters per line
Char. height 20 mm
Max 5 characters

B Description label
size 140 x 33 mm
Char. height 6 mm
23 char. per line , max 3 lines

C Apparatus label
52 x 13 mm
Char. height 3,5 mm
17 char. per line, max 2 lines
Standard location is about 12 mm below the apparatus

Model Sign text pcs. Location

TechnApp - 1 3AFY64556568