DD51-E DD51-E-RF: Operating Instructions
DD51-E DD51-E-RF: Operating Instructions
Contents
1. Safety Instructions 4
1.1 Product release information 5
2. Description 6
2.1 Version - DD51-E-RF 7
3. Installation 7
4. Display 8
5. Key functions 8
6. Switching on/off the device 11
6.1 Switching on the device 11
6.2 Switching off the device (for storage only)11
7. Operating mode 12
7.1 Reference points, origin and offset 12
7.2 Resolution 13
7.3 Absolute or relative measure selection13
7.4 Unit of measure selection 14
7.5 Reference measurement reset 14
7.6 Reference point setting 14
7.7 Direct programming of Origin, Offset
and Step parameters 15
7.8 Targets 16
7.8.1 Programming the targets 16
7.8.2 Load a target 16
7.8.3 Indications for reaching the target
position 16
7.8.4 Disabling the target 17
7.8.5 Display in target mode 17
EN
2 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
EN
Models all rights reserved in accordance with the law. Always mention 3
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
1. Safety Instructions
This device has been designed and manufactured in
accordance with current legislation. To keep the product in
this state, it must be assembled and used correctly, in strict
compliance with the instructions contained in this instruction
manual and with the following specific safety precautions. This
manual is intended as an indispensable supplement to the
existing documentation (catalogues, data sheets and assembly
instructions). Make sure that the user has read and understood
the instruction manual and in particular this chapter "Safety
instructions". In addition to the instruction manual, all legal
regulations regarding accident prevention and environmental
protection must be observed. This device complies with Part
15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received,
including interference that may cause undesired operation.’
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates,uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
4 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
EN
Models all rights reserved in accordance with the law. Always mention 5
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
2. Description
The DD51-E position indicators, with battery power supply,
can be used, mounted on pass-through shafts, to provide the
reading of the absolute or relative positioning of a machine
component.
(2)
Default: 600 r.p.m.
Target positions
PLC
Current positions
3. Installation
1.Drill a Ø 6x10 mm hole in the machine body with a 22 mm
centre distance from the shaft for mounting the rear reference
pin.
EN
Models all rights reserved in accordance with the law. Always mention 7
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
4. Display
1 2 3 4
6 6
5. Key functions
EN
8 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
EN
Models all rights reserved in accordance with the law. Always mention 9
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
10 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
- press the key to confirm. The display will switch off and
the indicator will go into sleep mode.
EN
Models all rights reserved in accordance with the law. Always mention 11
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
7. Operational mode
7.1 Reference points, origin and offset
When the device is turned on or reset, the position of the shaft
at that moment is set as the origin of the measure.
The value attributed to this position is given by the parameters,
Origin and Offset, which can be set by the user. Origin is an
arbitrary number that can be set in the range -19999÷99999
depending on the resolution set and is to be considered as the
machine’s limit switch value in its default conditions.The offset
is added to Origin which is always an arbitrary value that can
be set in the range -19999÷99999 depending on the resolution
and which allows you to move the actual origin of the measure
based on any changes in the machine configuration.
For example, a certain set point can operate different tools with
relative displacements of the point of origin. For example, in
the case of a tube cutting machine the device indicates the
position of the stop that determines the length of the tube. The
limit switch point is fixed but it does not necessarily correspond
to a zero length of the tube and therefore Origin will be different
from zero but always the same.
However, the machine makes it possible to mount different
blades depending on the type of tube and these can have
different positions and/or thicknesses.Therefore the actual
length will have to be corrected with a determined value which
will be memorised as an offset.
For greater flexibility of use, the DD51-E permits storage of up
to 10 different offset values. To program the offset values see
the OFFS parameter in chap. 8.2.
However, during installation and for other specific applications,
it is useful to be able to reset the internal reference value in
another position. For this purpose, see chap. 8.5.1.
WARNING:The value of the Origin parameters and the offsets
are the same for the mm and inch units of measure and are
displayed, depending on the unit of measure in use (see
chap. 7.4), with the appropriate conversion coefficient.In the
case of degrees, these parameters are totally different and
independent from the previous ones.
EN
12 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
7.2 Resolution
The device manages different measure display resolution values
for each of the three units of measure managed (mm, inch and
degrees). The same display resolution set is used to set different
parameters such as Origin, offsets and targets.
WARNING: If the resolution of one of the units of measure is
changed, to avoid setting errors, all the parameters that are
affected are reset: Origin, offset, etc.: It is therefore advisable
to decide and set the display resolution of all units of measure
as a first step in installing the device.To make the most of the
device's measure capacity, the resolution is automatically
reduced if the measure to be displayed exceeds the capacity
of the display. The measure on the display will flash.
In this case, the resolution variation is temporary (it is restored
if the display is able to display the measurement with the set
resolution) and has no effect on the set parameters.
to zero by pressing + .
EN
Models all rights reserved in accordance with the law. Always mention 13
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
14 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
+
- OFF: the key combination is disabled.
pressing the key , the selected offset value will be loaded and
Models all rights reserved in accordance with the law. Always mention 15
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
parameter).
+
- OFF: the key combination is disabled.
7.8 Targets
The DD51-E allows you to set up to 32 target positions allowing
you to store any relevant and frequently used settings.
M < T - Toll
(blinking) (blinking)
T - Toll ≤ M < T
M=T
T < M ≤ T + Toll
M > T + Toll
(blinking) (blinking)
7.8.4 Disabling the target
If a target is active, it can be cancelled by accessing
programming mode and selecting the StOPt option.
WARNING: while a target is active, it will not be possible
to change the unit of measurement, set the origin
and other functions accessible from the keyboard.
The absolute or relative measurement function remains
available but remember that the target values both stored on
the device and sent via RF always refer to the absolute value.
7.8.5 Display in target mode
By pressing the key when a target is active, you can view
the current position or the target position depending on the
device settings.
It is possible to modify the function of the key
____0 and the target mode by selecting one of the
options available in the menu item _ _ _ _0 (see
chap. 8.3)
The available options are:
Models all rights reserved in accordance with the law. Always mention 17
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
EN
18 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
7.9.2 Targets
Using the DD51-E-RF, the target positions can be sent from
the PLC to the indicators via the UC-RF control unit. When a
target is transmitted, it behaves in the same way described in
chap. 7.8.
WARNING: If the target transmission on UC-RF is enabled, it
will be refreshed on the DD every time a communication occurs.
Consequently, before disabling the target on the device (see
chap. 7.8.4), disable the target transmission on UC-RF.
8. Programming mode
Models all rights reserved in accordance with the law. Always mention 19
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
EN
20 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
EN
Models all rights reserved in accordance with the law. Always mention 21
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
EN
22 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
o--
dir
--o
*
The values must be divided by the number of decimal
places of the resolution set.
EN
Models all rights reserved in accordance with the law. Always mention 23
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
0°
diSPL
180°
300
SPEEd 600
1000
00
nEt id ...
99
rAdio ch 01
nEt ch ...
ch 36
mm 0.01 ÷ 9.99
PtoLL
inch 0.001 ÷ 0.393
degrees 0.01÷9.99
0____ ALL
nodEG
OFF
ArCLr
__0__
Scrolling direction
Ar
OFF
____0 dtoGo
dtArG
OFF
P_OrG
0___0 P_StP
P_OFS
OFF
__0_0 L_OFS
SEtOrG
OFF
EN
24 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
StoPt
Scrolling direction
LtG 01
LOAdt ...
LtG 32
*
The values must be divided by the number of decimal
places of the resolution set.
8.5.1 Reset
To restore the factory settings on the device:
- select the voice rESEt from the main menu (see chap. 8.3)
- select the voice rESEt from the main menu (see chap. 8.3)
Models all rights reserved in accordance with the law. Always mention 25
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
8.5.4 Password
You can avoid unwanted access to the device menu by
choosing “on“ in the PASS menu item. In this case to enter the
menu the password 22011 must be inserted.
9. Battery replacement
EN
26 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
Message on
Description Action
the display
In operational mode, the
device continues to correctly
measure the position of the
shaft. If the measured value
is within the capacity of
the display, it will be shown
correctly. If you are viewing a
The value cannot parameter, the problem may
be displayed be due to the difference in
because it units of measure between
----- exceeds the when it was set and when
capacity of the it is displayed. Change the
display current unit of measure
(-19999;99999) and try again to view the
parameter. Attempting to
change a parameter when the
display shows
------, automatically returns the
parameter to the first value
that can be displayed, losing
the initial setting.
The shaft has
exceeded
Press the key to go
S_Err the maximum
back to reading the measured
permitted
value.
rotation speed.
EN
Models all rights reserved in accordance with the law. Always mention 27
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
Declare that the DoC is issued under our sole responsibility and
belongs to the following product:
PRODUCT: Electronic Position Indicators
APPARATUS MODEL: DD51-E
TRADE MARK: Elesa
Notified Body:
Not Involved (Annex II - Conformity Assessment Module A)
Additional information:
Software Version: 5.1 or higher
EN
28 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators
Declare that the DoC is issued under our sole responsibility and
belongs to the following product:
PRODUCT: Electronic Position Indicators
APPARATUS MODEL: DD51-E-RF
TRADE MARK: Elesa
Notified Body:
Not Involved (Annex II - Conformity Assessment Module A)
Additional information:
Software Version: 5.1 or higher
EN
Models all rights reserved in accordance with the law. Always mention 29
the source when reproducing our drawings and photos.
Elesa S.p.A., Monza, September 2023
The texts and examples have been written with great care,
nonetheless, mistakes can always happen.
ELESA S.p.A.
Via Pompei, 29
DDEMAN-001-12IT