OPERATING INSTRUCTIONS

Electronic digital position indicators

DD51-E (GN 9054)*


DD51-E-RF(GN 9154)*
*(Product series valid only for Germany)
DD51-E - DD51-E-RF Electronic digital position indicators

Contents

1. Safety Instructions 4
1.1 Product release information 5
2. Description 6
2.1 Version - DD51-E-RF 7
3. Installation 7
4. Display 8
5. Key functions 8
6. Switching on/off the device 11
6.1 Switching on the device 11
6.2 Switching off the device (for storage only)11
7. Operating mode 12
7.1 Reference points, origin and offset 12
7.2 Resolution 13
7.3 Absolute or relative measure selection13
7.4 Unit of measure selection 14
7.5 Reference measurement reset 14
7.6 Reference point setting 14
7.7 Direct programming of Origin, Offset
and Step parameters 15
7.8 Targets 16
7.8.1 Programming the targets 16
7.8.2 Load a target 16
7.8.3 Indications for reaching the target
position 16
7.8.4 Disabling the target 17
7.8.5 Display in target mode 17

EN

2 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

7.9. Version - DD51-E-RF 18


7.9.1 Programming the Net ID and Net
CH parameters 18
7.9.2 Targets 19
8. Programming mode 19
8.1 Input of numeric parameters 19
8.2 Programmable parameters (in
alphabetical order) 20
8.3 Main menu tree 23
8.4 Target menu tree 25
8.5 Additional functions 25
8.5.1 Reset 25
8.5.2 LCD test 25
8.5.3 Device version 26
8.5.4 Password 26
9. Battery replacement 26
10. Display messages and troubleshooting 27

EN

Models all rights reserved in accordance with the law. Always mention 3
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

1. Safety Instructions
This device has been designed and manufactured in
accordance with current legislation. To keep the product in
this state, it must be assembled and used correctly, in strict
compliance with the instructions contained in this instruction
manual and with the following specific safety precautions. This
manual is intended as an indispensable supplement to the
existing documentation (catalogues, data sheets and assembly
instructions). Make sure that the user has read and understood
the instruction manual and in particular this chapter "Safety
instructions". In addition to the instruction manual, all legal
regulations regarding accident prevention and environmental
protection must be observed. This device complies with Part
15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received,
including interference that may cause undesired operation.’
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates,uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.

IMPORTANT NOTE (only for RF version): To comply with FCC


RF exposure compliance requirements, the antenna used for
this transmitter not be co-located or operating in conjunction
with any other antenna or transmitter.

Use without respecting the specific descriptions/


parameters, in combination with systems/
machines/processes to be controlled, can lead
to product malfunction, which causes:
- health hazards,
- environmental hazards,

- damage to the product and to its proper functionality.

The device must not be used:

- in explosion hazard areas;


EN

4 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

- in medical/life support areas and equipment.


Do not open the equipment and do not apply any modifications!
Modification of the equipment could adversely affect the
reliability of the device and could lead to hazards! Do not
attempt any repairs. Always return any defective equipment to
the manufacturer! Any breach of the integrity of the device as
delivered will invalidate the warranty. Changes or modifications
not expressly approved by the manufacturer could void the
user’s authority to operate the equipment.
Configuration / Commissioning
In the event of abnormal behaviour (including change
of operating conditions), the device must be shut down
immediately. Installation and commissioning must only be
carried out by adequately trained and authorised personnel.
After correct assembly and commissioning, the device is ready
for operation.
Maintenance/repair
Switch off the power supply to the equipment before carrying
out any operation. Maintenance must be performed only by
trained and authorised persons.
Do not open or modify the indicator case. Tampering with this
product can compromise the correctness and accuracy of its
function. In the event of a malfunction, do not attempt to repair
the unit.

1.1 Product release information


Although almost all features are the same as in previous
releases, this manual specifically refers to devices updated to
firmware revision 6.0 or later.
Some menu items may not be described as they relate to
functionalities that are additional, experimental or reserved for
special use. In case of specific need, it is recommended to ask
the Elesa service staff for assistance.
Elesa reserves the right, without further communication, to
make improvements, additions, corrections to the menu items,
that do not modify or affect the described functionality of the
product but are necessary for the continuous improvement to
which these products are subjected.

EN

Models all rights reserved in accordance with the law. Always mention 5
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

2. Description
The DD51-E position indicators, with battery power supply,
can be used, mounted on pass-through shafts, to provide the
reading of the absolute or relative positioning of a machine
component.

Mechanical and electrical characteristics


Power supply Lithium battery CR2450 3.0 V
Up to 3 years
Battery life (up to 2 years for RF version)
5-digit LCD of 8 mm height
Display and special characters
Reading scale -19999; 99999
Number of decimal digits programmable
mm, inches, degrees
Unit of measure
programmable
300/600/1000 r.p.m. (2)
Rotation max. speed
programmable
Resolution 10.000 impulses/revolution
Protection level IP65 or IP67
Working temperature 0 °C ÷ +50 °C
Storage temperature -20 °C ÷ +60 °C
max. 95% a 25 °C
Relative humidity without condensation
Environment indoor use
For use in closed and
Conditions of use
sheltered places only
Altitude up to 2000 m
RF frequencies
(RF devices only) 2400-2416MHz

(2)
Default: 600 r.p.m.

A rotation speed higher than 600 rpm can only be maintained


for short periods of time.
The maximum speed value affects the battery life.
Battery life depends on the conditions of use (setup,
temperature, ...). The indicated value is an estimate made in
temperature conditions > 20 ° C and <30°C and default setup.
Furthermore, this value refers to the condition of the device
when it leaves the Elesa factory. Long storage times must
always be considered for the estimation of the battery life when
EN the device becomes operational.
6 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

2.1 Version – DD51-E-RF


The DD51-E-RF is compatible with Elesa wireless network
which allows meters and electronic indicators to communicate
via radio with a PLC.
Elesa wireless network is made by the following components:
- One control unit UC-RF
- Max 36 device as DD51-E-RF, DD52R-E-RF or MPI-R10-RF

Target positions

PLC

Current positions

The UC-RF exchanges information with the DD51-E-RF via


radio frequency and makes it possible to set the target position
and check the current position of each indicator. Through
an interface, available for the most common industrial buses
(ProfiNet, Ethernet/IP, Modbus/TCP, and others), the UC-RF
control unit allows the exchange of this information with a PLC
and/or a generic controller of the machine.

3. Installation
1.Drill a Ø 6x10 mm hole in the machine body with a 22 mm
centre distance from the shaft for mounting the rear reference
pin.

2. Mount the indicator on


the shaft and make sure the
reference pin fits into the hole.

3. Lock the bushing on the shaft


by tightening the grub screw
with a 2.5 mm hexagon socket
(as per UNI 5929-85).

EN

Models all rights reserved in accordance with the law. Always mention 7
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

4. Display

1 2 3 4

6 6

1. Relative mode indicator


2. Low battery level indicator
3. Connection indicator (only for DD51-E-RF)
4. Unit of measure: mm, inch
5. Unit of measure: degrees
(in the version with FW 6.1.99 the indication of the unit
of measurement in degrees is a D in position 4)
6. Target position indications
(these indicators are absent in the version with FW
6.1.99)

5. Key functions

EN

8 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

Key Or Key Operating Programming


Combination Mode Mode
Keeping the key pressed
down for 3s activate
programming mode.
When in target mode, it
reacts to a short press
according to the setting
of item _ _ _ _ 0 of the
main menu (chap. 8.3):
d_tArG: When
a target is loaded,
the display shows Select the item
the current absolute menu or
position. By pressing confirm selection
the key, the position of or
the destination to be insertion
reached appears on the of the
display. parameter value
d_toGO[DEFAULT]:
when a target is loaded,
the display flashes the
distance from the current
position to the target
position to be reached.
By pressing the key, the
current absolute position
will appear on the display.
OFF: the function is
disabled.

EN

Models all rights reserved in accordance with the law. Always mention 9
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

Select the measure mode:


ABS: absolute measure
mode
REL: relative measure mode
It is possible to choose one
of the following options (see
item _ _ 0 _ _ of the menu - Digit increase
chap.8.3): selected /
ArCLr [DEFAULT]: when exit
changing from ABS to REL
the counter is reset
Ar: when changing from
ABS to RELthe counter is
not reset.
OFF: the function is disabled.

Unit of measure selection.


The available options are:
millimetres, inches and
degrees. Scroll down
It is possible to choose one the list of
of the following options (see possible
item 0 _ _ _ _ of the menu – selections
chap. 8.3):
or menu
ALL [DEFAULT]:
selectable units of items / select
measure: mm, inch, D the next digit
nodEG: selectable units of
measure: mm, inch
OFF: the function is disabled.

Programmable for one of


the following functions (see
menu item 0 _ _ _ _ 0 –
chap.8.3):
P_OrG [DEFAULT]: shows
and allows you to set the
OriGin parameter.
+ P_OFS: shows and allows N/A
you to set the OFFS
parameters.
P_StP: shows and allows
you to set the StEP
parameters.
OFF: the combination is
disabled.
EN

10 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

In relative measure mode,


resets the measure.
In absolute measure mode
it is programmable for one
of the following functions
(see menu item _ _ 0 _ 0 –
chap.8.3):
+ L_OFS [DEFAULT]: N/A
select one of the offsets (see
chap.7.6 and 7.7).
SetOrg:the key combina-
tion allows to reset the origin
(see chap. 7.5)
OFF: the combination is
disabled.
Note: the words: increase, decrease, up and down, refer to
the direction of the arrow in the default configuration as shown
in the figure. By changing the orientation of the display, the
meaning of the keys is reversed accordingly.

6. Switching on/off the device


6.1 Switching on the device
After reading and understanding the “Safety Instructions”
section, proceed by switching on the indicator.

To switch on the indicator, hold down while pressing the

key . The display will switch on and the indicator will be


ready for use.
ATTENTION: When the device is turned on, especially after a
long period of storage, it is possible that some segments of
the display remain abnormally lit during the startup phase. The
phenomenon is transitory and does not affect correct operation
and use of the device as it will disappear in a short time.

6.2 Switching off the device (for storage only)

To switch the system off:


- select the rESEt item from the main menu (see chap.8.3)

- using the key , scroll through the items to select OFF.

- press the key to confirm. The display will switch off and
the indicator will go into sleep mode.
EN

Models all rights reserved in accordance with the law. Always mention 11
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

7. Operational mode
7.1 Reference points, origin and offset
When the device is turned on or reset, the position of the shaft
at that moment is set as the origin of the measure.
The value attributed to this position is given by the parameters,
Origin and Offset, which can be set by the user. Origin is an
arbitrary number that can be set in the range -19999÷99999
depending on the resolution set and is to be considered as the
machine’s limit switch value in its default conditions.The offset
is added to Origin which is always an arbitrary value that can
be set in the range -19999÷99999 depending on the resolution
and which allows you to move the actual origin of the measure
based on any changes in the machine configuration.
For example, a certain set point can operate different tools with
relative displacements of the point of origin. For example, in
the case of a tube cutting machine the device indicates the
position of the stop that determines the length of the tube. The
limit switch point is fixed but it does not necessarily correspond
to a zero length of the tube and therefore Origin will be different
from zero but always the same.
However, the machine makes it possible to mount different
blades depending on the type of tube and these can have
different positions and/or thicknesses.Therefore the actual
length will have to be corrected with a determined value which
will be memorised as an offset.
For greater flexibility of use, the DD51-E permits storage of up
to 10 different offset values. To program the offset values see
the OFFS parameter in chap. 8.2.
However, during installation and for other specific applications,
it is useful to be able to reset the internal reference value in
another position. For this purpose, see chap. 8.5.1.
WARNING:The value of the Origin parameters and the offsets
are the same for the mm and inch units of measure and are
displayed, depending on the unit of measure in use (see
chap. 7.4), with the appropriate conversion coefficient.In the
case of degrees, these parameters are totally different and
independent from the previous ones.

EN

12 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

7.2 Resolution
The device manages different measure display resolution values
for each of the three units of measure managed (mm, inch and
degrees). The same display resolution set is used to set different
parameters such as Origin, offsets and targets.
WARNING: If the resolution of one of the units of measure is
changed, to avoid setting errors, all the parameters that are
affected are reset: Origin, offset, etc.: It is therefore advisable
to decide and set the display resolution of all units of measure
as a first step in installing the device.To make the most of the
device's measure capacity, the resolution is automatically
reduced if the measure to be displayed exceeds the capacity
of the display. The measure on the display will flash.
In this case, the resolution variation is temporary (it is restored
if the display is able to display the measurement with the set
resolution) and has no effect on the set parameters.

7.3 Absolute or relative measure selection


Press the key to select the absolute or relative measure
mode. The relative measure mode is indicated on the display
by the symbols:
ABS: absolute measure mode
REL: relative measure mode
__0__ It is possible to change the function of the key
by choosing one of the options available in the
menu item _ _ 0 _ _
The available options are:
- ArCLr(default): when changing from ABS to REL the
counter is reset.
- Ar: when changing from ABS to REL the counter is not reset.
In both cases, only in relative measure mode, the counter is set

to zero by pressing + .

- OFF: the key is disabled and it is not permitted to


change the measure mode.

EN

Models all rights reserved in accordance with the law. Always mention 13
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

7.4 Unit of measure selection

Press the key to select the required unit of measure.

The available options are millimetres, inches and degrees.

The selected measure mode is indicated on the display by the


symbols:
- mm: millimeters - INCH: inches - D: degrees
0____ It is possible to change the function of the key
by choosing one of the options available in the
menu item. 0_ _ _ _
The available options are:

- ALL (default): selectable units of measure: mm, inches and


degrees.

- nodEG: selectable units of measure: mm, inch

- OFF: the key is disabled and it is not permitted to


change the selected measure mode.

7.5 Reference measurement reset


It is possible to reset the internal reference of the measure
device of the device for the measurement by enabling the

appropriate SetOrg function of the pair of keys +


, to reset the internal reference see chap. 7.6.
In this case when the two keys are pressed at the same time,
the message SEtOrg is diplayed.

Pressing the button to confirm the choice ant to reset


the origin point to the current position. Alternatively, the Reset
command can be used as described in chap. 8.5.1.
7.6 Reference point setting

Using this key combination + it is possible to reset


the measure references of the device by loading the origin
value and an offset value (see chap. 7.1).

__0_0 It is possible to change the function of the key


combination by choosing one of the options

EN available in the menu item _ _0 _0

14 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

The available options are:


- L_OFS: the key combination allows you to select an offset .
- SetOrg: the key combination allows to reset the origin (see
chap. 7.5).

+
- OFF: the key combination is disabled.

WARNING: This function is available only in absolute


measure mode.
If the OFFS option has been selected, pressing the key

combination + lwill display the last used offset value


(e.g. OFFS 0). It is possible to choose the desired compensation

value among the 10 memorized by pressing the key . Then, by

pressing the key , the selected offset value will be loaded and

used in the measurement. By pressing the key , the operation


will be cancelled. If the SEtOrg option has been selected, pressing

the key combination + the screen will show SEtOrg. By

pressing the ke the origin of the measurement will be moved


to the current position and the display will show the value of the
origin point given by the value of Origin + Offset.

7.7 Direct programming of Origin, Offset and


Step parameters
+
The key combination allows direct access to the
programming of one of the following parameter: Origin, Offset
or Step.

0___0 It is possible to change the function of the


key combination by choosing one of the
options available in the menu item 0 _ _ _ 0.
The available options are:
- P_OrG: direct programming of the absolute reference
value (Origin parameter)
- P_StP: direct programming of the reading after one
revolution (Step parameter)
- P_OFS: direct programming of the offset value (OFFS EN

Models all rights reserved in accordance with the law. Always mention 15
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

parameter).
+
- OFF: the key combination is disabled.

7.8 Targets
The DD51-E allows you to set up to 32 target positions allowing
you to store any relevant and frequently used settings.

7.8.1 Programming the targets


To program the targets:
- select tArGE in the main menu (see chap. 8.3)
- select PrOGt (see chap. 8.4)
- select the desired memory location (from PtG01 to PtG32)

using the key .

- press the key to select.

- follow the instructions in chap. 8.1 to set the desired value.

7.8.2 Load a target:


To load a target:
- selecttArGE in the main menu (see chap. 8.3)
- select LOAdt (see chap. 8.4)
- select the desired target value (from LtG01 to LtG32)

using the key .

- Press the key to select.


- The selected target value is displayed.

- Press again to confirm or press to return to the


target selection list.

7.8.3 Indications for reaching the target position


When a target is selected it is sent by the PLC (RF version
only), the device will sug gest the direction of rotation of
the shaft to reach the target through the symbols of
the target position indicators (from fw version 6.2).
It is possible to set an acceptable tolerance value for the
targets through the PtOLL parameter so that the target
EN position is considered to have been reached when the
16 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

difference between the set target and the current position


is less than PtOLL in absolute value.
The target position indicators work, depending on
the, dir and PtOLL parameters, as in the following
table:
T = target value set
M = actual measure
Toll = tolerance (see PtOLL)
dir –o dir o--

M < T - Toll
(blinking) (blinking)
T - Toll ≤ M < T
M=T
T < M ≤ T + Toll

M > T + Toll
(blinking) (blinking)
7.8.4 Disabling the target
If a target is active, it can be cancelled by accessing
programming mode and selecting the StOPt option.
WARNING: while a target is active, it will not be possible
to change the unit of measurement, set the origin
and other functions accessible from the keyboard.
The absolute or relative measurement function remains
available but remember that the target values both stored on
the device and sent via RF always refer to the absolute value.
7.8.5 Display in target mode
By pressing the key when a target is active, you can view
the current position or the target position depending on the
device settings.
It is possible to modify the function of the key
____0 and the target mode by selecting one of the
options available in the menu item _ _ _ _0 (see
chap. 8.3)
The available options are:

- OFF: the key is disabled. This setting is related to the


target mode. Other functions are not involved.
- dtArG (default): when a target is activated, the display
shows the actual absolute position and the indication to reach
the target (see chap. 7.8.3). EN

Models all rights reserved in accordance with the law. Always mention 17
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

Pressing the key shows the set target position.


- dtoGo: when a target is activated, the display flashes
showing the distance from the set target and the indication to
reach the target (see chap. 7.8.3). When the target is reached,
less than the set tolerance, the display shows the current
position and stops flashing.

Pressing the key ,the display shows the current absolute


position.

7.9 Version - DD51-E-RF


7.9.1 Programming the Net ID and Net CH
parameters
Each RF device is defined within the Elesa wireless network by
the following two parameters:
nEt id: this is a number between 0 and 99 and differentiates
different subnets allowing different systems to work on the
same RF channels.
nEt ch: this is the RF transmission channel and can be set
from 1 to 36. Two or more devices set to the same Net CH
cannot have the same Net ID.
These parameters can be configured in the indicator’s Radio
menu (see chap. 8.2) and must be set according to the PLC
settings to ensure perfect communication with UC-RF.
WARNING: In pre-existing systems in which a UC-RF with
a firmware release prior to 0F051120 is used (for more
information refer to the UC-RF manual) it is necessary to take
into consideration that the Net CHs are out of phase by 3
channels. In practice, a DD51-E-RF set with Net CH = 1 will
communicate with UC-RF on CH = 4 and so on for the following
channels.
It will not be possible for DD51-E-RF with firmware revision
6.0 or later to communicate with older generation UC-RF on
channels 1 to 3.

ATTENTION: some NetIds may conflict with each other, we


recommend consulting the document Elesa-R&D-DDEMAN-
005-01en - NetID - allowed values - feb 23 and for more
detailed information or the UC-RF user manual updated to
version R02 or later.

EN

18 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

7.9.2 Targets
Using the DD51-E-RF, the target positions can be sent from
the PLC to the indicators via the UC-RF control unit. When a
target is transmitted, it behaves in the same way described in
chap. 7.8.
WARNING: If the target transmission on UC-RF is enabled, it
will be refreshed on the DD every time a communication occurs.
Consequently, before disabling the target on the device (see
chap. 7.8.4), disable the target transmission on UC-RF.

8. Programming mode

Press the key for 3 seconds to access programming


mode. Depending on the setting of the PASS parameter
(see chap. 8.5.4), the system may ask for a password to

be entered. Press the key to scroll through the list of


menu items or parameters and select the desired one by

pressing the key . Press the key to return to the


previous menu level (when allowed) or exit programming
mode. Programming mode is automatically exited after 30
seconds of inactivity.
WARNING: When programming the parameters, the bushing
must be locked in the current position, otherwise there is the
possibility of obtaining a false measurement once you exit the
programming mode. If this is not possible, it is recommended
to check the device setting once back in measurement mode.
8.1 Input of numeric parameters
Press the key the selected digit, flashing, increases
in value up to 9 and then returns to 0.
If the first digit on the left is selected and the parameter
can assume negative values, -1 will be displayed after
digit 9 and, by pressing the key again, -.

It is possible to select the digit to be changed by

pressing the key With each press, the digit to the


right of the current one will be selected. If the selected
digit is already at the far right of the display, the selection
will jump to the first digit on the left.
EN

Models all rights reserved in accordance with the law. Always mention 19
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

Press the key to confirm the value entered. If the


confirmed parameter is different from the one currently
stored, the display will show the message CHAnGd.
WARNING: It is not possible to cancel the insertion of
a parameter value but only to confirm the displayed one.
If you do not want to change the value already stored, it
is obviously possible to set it to the same value as before
and check that the word CHAnGd. does not appear. Or,
by waiting 30s, the device will exit programming mode
without saving the changes.
The value of any modified parameters is stored only
when exiting the programming mode. If the operation was
successful, the display will show the messag StorE.

8.2 Programmable parameters (in alphabetical order)

Parameter Description Available options Default


dir Direction of --o anticlockwise --o
measure. o-- clockwise
Sets the
positive
rotation
direction of
the shaft.
diSPL Display 0° 180°
orientation 180°
Offset Offset It is possible to store up to 0
values 10 offset value:
OFS 0 ... OFS 9
The settable values depend
on the resolution set as
follows:
Res = 1 : -19999 ÷ 99999
Res = 0.1 : -1999.9 ÷ 9999.9
Res = 0.01: -199.99 ÷ 999.99
Res =0.001: -19.999 ÷ 99.999

EN

20 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

Parameter Description Available options Default


Origin Reference The settable values depend 0.0
value on the resolution set as
follows:
Res = 1 : -19999 ÷ 99999
Res = 0.1 : -1999.9 ÷ 9999.9
Res = 0.01: -199.99 ÷ 999.99
Res =0.001: -19.999 ÷ 99.999
Ptoll Tolerance The settable values depend mm:
of target on the unit of measure 0.10
position in use: inches:
mm: 0.01 ÷ 9.99 0.004
Degrees:
inches: 0.001 ÷ 0.393
0.10
degrees: 0.01 ÷ 9.99

Radio RF settings nEt id: id00 ÷ id99 Netid:


00
nEt ch: ch01 ÷ ch36
Netch:
01
rES Resolution Depending on the unit of mm:
of the measurement, the 0.01
displayed inches:
permitted values are:
0.001
measure mm: 1; 0.1; 0.01 degrees:
inches: 1; 0.1; 0.01; 0.001 0.01°
degrees: 1; 0.1; 0.01
An independent resolution is
stored for each unit of measure.

SPEEd Maximum 300; 600; 1000 600


permitted
shaft rotation
speed

EN

Models all rights reserved in accordance with the law. Always mention 21
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

Parameter Description Available options Default


StEP Conversion The programmable 001.00
coefficient values depend on the
between selected unit of measure:
the number mm: 0.01 ÷ 999.99
of shaft inch : 0.001 ÷ 99.999
rotations
and the degrees: 0.01 ÷ 999.99
selected The step value for
unit of mm and inch is the
measure same except for the
appropriate conversion
when viewing the
measure. The Step value
for degrees is, on the
other hand, independent.
“t_Sho” Display d_toG0
mode when or
the target is
d_tArG:
active.
In the menu
appears as d_toG0
See chap. 7.8.5.
the setting
for the
key
(_ _ _ _ 0)

EN

22 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

Parameter Description Available options Default


tArGE Target It is possible to store up to 0.0
positions 10 offset values: TG 01, ...,
TG 32.
The settable values depend
on the resolution set as
follows:
Res = 1 : -19999 ÷ 99999
Res = 0.1 : -1999.9 ÷ 9999.9
Res = 0.01: -199.99 ÷ 999.99
Res =0.001: -19.999 ÷ 99.999

8.3 Main menu tree

o--
dir
--o

OrG -19999 ÷ 99999*


OFS 0 -19999 ÷ 99999*
OFFS ...
OFS 9 -19999 ÷ 99999*

StEP mm: 0.01 ÷ 999.99


inch: 0.001 ÷ 99.999
Scrolling direction

gradi: 0.01 ÷ 999.99

rES mm inch deg


1 1 1
0.1 0.1 0.1
0.01 0.01 0.01
0.001

*
The values must be divided by the number of decimal
places of the resolution set.

EN

Models all rights reserved in accordance with the law. Always mention 23
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators


diSPL
180°

300
SPEEd 600
1000
00
nEt id ...
99
rAdio ch 01
nEt ch ...
ch 36

mm 0.01 ÷ 9.99
PtoLL
inch 0.001 ÷ 0.393
degrees 0.01÷9.99

tArGE See chap. 8.4

0____ ALL
nodEG
OFF
ArCLr
__0__
Scrolling direction

Ar
OFF

____0 dtoGo
dtArG
OFF
P_OrG
0___0 P_StP
P_OFS
OFF

__0_0 L_OFS
SEtOrG
OFF

PASS See chap. 8.5.4

rESEt See chap. 8.5.1

LcdtS See chap. 8.5.2

r6.0.00** Release Version (see chap.8.5.3)


**
The revision code may vary depending on the actual
revision of the firmware loaded on the device.

EN

24 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

8.4 Target menu tree

StoPt
Scrolling direction

PtG 01 -19999 ÷ 99999*


PrOGt ...
PtG 32 -19999 ÷ 99999*

LtG 01
LOAdt ...
LtG 32
*
The values must be divided by the number of decimal
places of the resolution set.

8.5 Additional functions

8.5.1 Reset
To restore the factory settings on the device:

- select the voice rESEt from the main menu (see chap. 8.3)

- using the key select ALL.

- press the key to confirm.

To reset the only internal reference measure:

- select the voice rESEt from the main menu (see chap. 8.3)

- using the key selezionare OrG.

- press the key to confirm.

To exit the reset command, press the key or:

- using the key select No.

- press the key to confirm.

8.5.2 LCD test


The LcdtS item in the main menu allows you to turn on all
the segments and symbols of the display to check that it is
working correctly. EN

Models all rights reserved in accordance with the law. Always mention 25
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

8.5.3 Device version


The device version code is displayed as the last item of the
main menu, with the r as the first character. By pressing the key

several times, other data are displayed which, if support


is required, must be noted and provided to Elesa.

WARNING: A variation of the last two digits in the revision code


has no impact on the device’s features and performance.

8.5.4 Password
You can avoid unwanted access to the device menu by
choosing “on“ in the PASS menu item. In this case to enter the
menu the password 22011 must be inserted.

9. Battery replacement

The internal lithium battery CR2450 - 3.0 V guarantees a


battery life up to 3 years (up to 2 years for RF). The symbol

appears on the display when the battery needs replacing.


To replace the battery, simply remove the battery cover without
removing the indicator from the drive shaft, keeping all the
configuration parameters unchanged. The cover is screwed
with two TORX T6 screws. To facilitate the removal of the
battery from the battery compartment, the use of a magnet is
recommended.

EN

26 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

10. Display messages and troubleshoting

Message on
Description Action
the display
In operational mode, the
device continues to correctly
measure the position of the
shaft. If the measured value
is within the capacity of
the display, it will be shown
correctly. If you are viewing a
The value cannot parameter, the problem may
be displayed be due to the difference in
because it units of measure between
----- exceeds the when it was set and when
capacity of the it is displayed. Change the
display current unit of measure
(-19999;99999) and try again to view the
parameter. Attempting to
change a parameter when the
display shows
------, automatically returns the
parameter to the first value
that can be displayed, losing
the initial setting.
The shaft has
exceeded
Press the key to go
S_Err the maximum
back to reading the measured
permitted
value.
rotation speed.

Replace the battery


Low Battery as soon as possible
Flashing
battery symbol
(see chap. 9).

EN

Models all rights reserved in accordance with the law. Always mention 27
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

EU DECLARATION OF CONFORMITY (DoC)


COMPANY NAME: Elesa S.p.a.
POSTAL ADDRESS: Via Pompei 29
POSTCODE AND CITY: 20900 Monza
TELEPHONE NUMBER: +39 039 28111
E-MAIL ADDRESS: [email protected]

Declare that the DoC is issued under our sole responsibility and
belongs to the following product:
PRODUCT: Electronic Position Indicators
APPARATUS MODEL: DD51-E
TRADE MARK: Elesa

The object of the Declaration described above is in conformity


with the relevant Union Harmonization Legislation:
2014/30/UE (EMC): Electromagnetic Compatibility Directive
2011/65/UE (RoHS): Restriction of the use of certain Hazardous
Substances in electrical and electronic equipment

The following harmonized standards and technical specifications


have been applied:
EN 61326-1:2013

Notified Body:
Not Involved (Annex II - Conformity Assessment Module A)
Additional information:
Software Version: 5.1 or higher

PLACE, DATE OF ISSUE: CARLO BERTANI


Monza – Italy MANAGING DIRECTOR
03/11/2021 GENERAL MANAGER

EN

28 Models all rights reserved in accordance with the law. Always mention
the source when reproducing our drawings and photos.
DD51-E - DD51-E-RF Electronic digital position indicators

EU DECLARATION OF CONFORMITY (DoC)


COMPANY NAME: Elesa S.p.a.
POSTAL ADDRESS: Via Pompei 29
POSTCODE AND CITY: 20900 Monza
TELEPHONE NUMBER: +39 039 28111
E-MAIL ADDRESS: [email protected]

Declare that the DoC is issued under our sole responsibility and
belongs to the following product:
PRODUCT: Electronic Position Indicators
APPARATUS MODEL: DD51-E-RF
TRADE MARK: Elesa

The object of the Declaration described above is in conformity


with the relevant Union Harmonization Legislation:
2014/53/EU (RED) Radio Equipment Directive
2011/65/UE (RoHS) Restriction of the use of certain Hazardous
Substances in electrical and electronic equipment

The following harmonized standards and technical specifications


have been applied:
EN 62311:2008
EN 61010-1:2010
ETSI EN 301 489-1 V2.1.1
ETSI EN 301 489-1 V2.2.3
ETSI EN 301 489-17 V3.1.1
Draft ETSI EN 301 489-17 v3.2.2
EN 61326-1:2013
ETSI EN 300 328 V2.2.2

Notified Body:
Not Involved (Annex II - Conformity Assessment Module A)
Additional information:
Software Version: 5.1 or higher

PLACE, DATE OF ISSUE: CARLO BERTANI


Monza – Italy MANAGING DIRECTOR
03/11/2021 GENERAL MANAGER

EN

Models all rights reserved in accordance with the law. Always mention 29
the source when reproducing our drawings and photos.
Elesa S.p.A., Monza, September 2023

The texts and examples have been written with great care,
nonetheless, mistakes can always happen.

The Company Elesa S.p.A. can neither be held legally


responsible nor liable for lacking or incorrect information and
the ensuing consequences.

The Company Elesa S.p.A. reserves the right to alter or


improve the electronic position indicators or parts of them and/
or the enclosed brochures without prior notice.

Art. Nr. ZZDOIU-DD51E-EN-R02


© COPYRIGHT ELESA 2023