Check For Collar Bracket
Check For Collar Bracket
CONCESSIONAIRE:
CONTRACTOR:
AUTHORITY ENGINEER:
L N MALVIYA INFRA PROJECTS PVT. LTD.
Corporate Office:
T-10, IIIrd Floor, City Centre, Press Complex, Plot No. 1, M.P. Nagar,
Zone-I Bhopal (M.P.), 462011
Tel./Fax : 0755-4295421 Email: [email protected]
Website: www.lninfra.com
PROOF CONSULTANT:
PROJECT TITLE:
CONSTRUCTION OF 6-LANE GREENFIELD CONNECTIVITY TO JEWAR INTERNATIONAL AIRPORT FROM
DND - FARIDABAD-BALLABHGARH BYPASS KMP LINK - SPUR TO DELHI MUMBAI EXPRESSWAY ON
HYBRID ANNUITY MODE IN THE STATE OF HARYANA AND UTTAR PRADESH UNDER BHARATMALA
PARIYOJANA
TITLE OF CALCULATION:
DESIGN CONSULTANT:
CDS CONSULT (INDIA) PVT. LTD.
Plot No.-537, GROUND & 1st FLOOR, SECTOR 31, GURUGRAM 122001
Tel: 0124-4032864 ;Email : [email protected] Web: www.cdsconsultindia.com
P
A
Load P= 200 kN
Page 1 of 11
1. STAAD SPACE
2. START JOB INFORMATION
3. ENGINEER DATE 23-OCT-24
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 3 2.5 1.1147 0; 7 1.25 2 -0.15; 17 1.25 2 1.15; 22 1.25 2.363 -0.15
9. 27 1.25 2.363 1.15; 32 1.25 2.363 -2.325; 37 1.25 2.363 3.325
10. 38 1.25 2.363 -0.5; 39 1.25 2.363 1.5; 40 1.25 2.188 -0.15; 41 1.25 2.188 1.15
11. 42 1.25 2.188 -0.5; 43 1.25 2.188 1.5; 44 1.25 2.188 0.2829
12. 45 1.25 2.188 0.7158; 46 1.25 2 0.2829; 47 1.25 2 0.7158; 48 1.25 2.363 0.2829
13. 49 1.25 2.363 0.7158
14. MEMBER INCIDENCES
15. 55 7 40; 56 17 41; 66 32 38; 67 22 48; 68 27 39; 69 38 22; 70 39 37; 71 40 22
16. 72 41 27; 73 40 44; 74 41 43; 75 42 40; 76 44 45; 77 45 41; 80 48 49; 81 49 27
17. 82 42 38; 83 44 48; 84 45 49; 85 43 39; 86 46 44; 87 47 45
18. *START USER TABLE
19. *TABLE 1 SHS132PLATE10.UPT
20. *END
21. DEFINE MATERIAL START
22. ISOTROPIC STEEL
23. E 2.05E+008
24. POISSON 0.3
25. DENSITY 76.8195
26. ALPHA 1.2E-005
27. DAMP 0.03
28. TYPE STEEL
29. STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2
30. END DEFINE MATERIAL
31. MEMBER PROPERTY INDIAN
32. 71 72 82 TO 85 TABLE ST ISMB350
33. MEMBER PROPERTY INDIAN
34. 66 TO 70 73 TO 77 80 81 TABLE D ISMC175
35. MEMBER PROPERTY TATASTRUCTURA
36. 55 56 86 87 TABLE ST 132X132X4.8SHS
37. *MEMBER PROPERTY
38. *1 18 TAPERED 0.152 0.0096 0.152 0.132 0.0148 0.132 0.0148
STAAD SPACE -- PAGE NO. 2
39. CONSTANTS
40. MATERIAL STEEL ALL
41. SUPPORTS
42. *7 17 FIXED BUT FY FZ MX MY MZ
43. *1 11 PINNED
44. 7 17 46 47 PINNED
45. *6 16 FIXED BUT FY FZ MX MY MZ
46. *MEMBER RELEASE
47. *71 72 END MX MY MZ
48. LOAD 1 LOADTYPE DEAD TITLE LOAD CASE 1
**WARNING- JOINT NO. 3 NOT CONNECTED. OK, IF PART OF MASTER/SLAVE.
**WARNING- THIS STRUCTURE IS DISJOINTED. IGNORE IF
Page 2 of 11
MASTER/SLAVE OR IF UNCONNECTED JOINTS.
49. MEMBER LOAD
50. 70 CON GY -1.485 1.825
51. 70 CON GY -49.4 0.54
52. 70 CON GY -14.586 0.6
53. 66 CON GY -1.485 0
54. 66 CON GY -49.4 1.285
55. 66 CON GY -14.586 1.225
56. 66 UNI GY -36 1.225 1.825
57. 70 UNI GY -36 0 0.6
58. *70 UNI GY -36 0 0.38
59. 67 TO 69 80 81 UNI GY -36
60. 67 CON GY -27 0.15
61. 81 CON GY -27 .283
62. LOAD 3 GENERATED INDIAN CODE GENRAL_STRUCTURES 1
63. REPEAT LOAD
64. 1 1.2
65. *LOAD 4 GENERATED INDIAN CODE GENRAL_STRUCTURES 2
66. *REPEAT LOAD
67. *1 1.0
68. PERFORM ANALYSIS PRINT ALL
PROBLEM STATISTICS
-----------------------------------
Page 3 of 11
70 -1.4850 GY 1.82
70 -49.4000 GY 0.54
70 -14.5860 GY 0.60
66 -1.4850 GY 0.00
66 -49.4000 GY 1.28
66 -14.5860 GY 1.23
66 -36.0000 GY 1.23 1.83
70 -36.0000 GY 0.00 0.60
67 -36.0000 GY 0.00 0.43
68 -36.0000 GY 0.00 0.35
69 -36.0000 GY 0.00 0.35
80 -36.0000 GY 0.00 0.43
81 -36.0000 GY 0.00 0.43
67 -27.0000 GY 0.15
81 -27.0000 GY 0.28
70 -1.7820 GY 1.82
70 -59.2800 GY 0.54
70 -17.5032 GY 0.60
66 -1.7820 GY 0.00
66 -59.2800 GY 1.28
66 -17.5032 GY 1.23
66 -43.2000 GY 1.23 1.83
70 -43.2000 GY 0.00 0.60
67 -43.2000 GY 0.00 0.43
68 -43.2000 GY 0.00 0.35
69 -43.2000 GY 0.00 0.35
80 -43.2000 GY 0.00 0.43
81 -43.2000 GY 0.00 0.43
67 -32.4000 GY 0.15
81 -32.4000 GY 0.28
*WARNING- ZERO STIFFNESS IN DIRECTION 1 AT JOINT 3 EQN.NO. 1
LOADS APPLIED OR DISTRIBUTED HERE FROM ELEMENTS WILL BE IGNORED.
THIS MAY BE DUE TO ALL MEMBERS AT THIS JOINT BEING RELEASED OR
EFFECTIVELY RELEASED IN THIS DIRECTION.
*WARNING- ZERO STIFFNESS IN DIRECTION 2 AT JOINT 3 EQN.NO. 2
*WARNING- ZERO STIFFNESS IN DIRECTION 3 AT JOINT 3 EQN.NO. 3
STAAD SPACE -- PAGE NO. 4
Page 4 of 11
PROBABLE CAUSE SINGULAR-ADDING WEAK SPRING
K-MATRIX DIAG= 5.6898456E+01 L-MATRIX DIAG= -8.2005158E-10 EQN NO 102
***NOTE - VERY WEAK SPRING ADDED FOR STABILITY
THE ABOVE CONDITIONS COULD ALSO BE CAUSED BY VERY STIFF OR VERY WEAK
ELEMENTS AS WELL AS TRUE SINGULARITIES.
FOR LOADING - 1
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
22 0.00000E+00-3.36136E+01 0.00000E+00 1.92431E+00 0.00000E+00 0.00000E+00
27 0.00000E+00-3.35736E+01 0.00000E+00-1.93233E+00 0.00000E+00 0.00000E+00
32 0.00000E+00-1.75446E+01 0.00000E+00 8.55903E+00 0.00000E+00 0.00000E+00
37 0.00000E+00-1.75446E+01 0.00000E+00-8.55903E+00 0.00000E+00 0.00000E+00
38 0.00000E+00-7.58264E+01 0.00000E+00-2.07904E+01 0.00000E+00 0.00000E+00
39 0.00000E+00-7.58264E+01 0.00000E+00 2.07904E+01 0.00000E+00 0.00000E+00
48 0.00000E+00-2.30630E+01 0.00000E+00-9.17073E-01 0.00000E+00 0.00000E+00
49 0.00000E+00-2.31498E+01 0.00000E+00 9.29942E-01 0.00000E+00 0.00000E+00
X = 0.125000004E+01
Y = 0.236299992E+01
Z = 0.499892082E+00
Page 5 of 11
SUMMATION OF MOMENTS AROUND THE ORIGIN-
MX= -150.04 MY= 0.00 MZ= 375.18
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
7 0.00 0.00 0.00 0.00 0.00 0.00
0.00 -200.57 61.63 0.00 0.00 0.00 111000
FOR LOADING - 3
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
22 0.00000E+00-4.03364E+01 0.00000E+00 2.30917E+00 0.00000E+00 0.00000E+00
27 0.00000E+00-4.02884E+01 0.00000E+00-2.31879E+00 0.00000E+00 0.00000E+00
32 0.00000E+00-2.10535E+01 0.00000E+00 1.02708E+01 0.00000E+00 0.00000E+00
37 0.00000E+00-2.10535E+01 0.00000E+00-1.02708E+01 0.00000E+00 0.00000E+00
38 0.00000E+00-9.09917E+01 0.00000E+00-2.49485E+01 0.00000E+00 0.00000E+00
39 0.00000E+00-9.09917E+01 0.00000E+00 2.49485E+01 0.00000E+00 0.00000E+00
48 0.00000E+00-2.76756E+01 0.00000E+00-1.10049E+00 0.00000E+00 0.00000E+00
49 0.00000E+00-2.77797E+01 0.00000E+00 1.11593E+00 0.00000E+00 0.00000E+00
Page 6 of 11
X = 0.125000004E+01
Y = 0.236299992E+01
Z = 0.499892113E+00
JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ
SUPPORT=1
7 0.00 0.00 0.00 0.00 0.00 0.00
0.00 -240.68 73.95 0.00 0.00 0.00 111000
Page 7 of 11
************ END OF DATA FROM INTERNAL STORAGE ************
69. PARAMETER 1
70. CODE IS800 LSD
71. CHECK CODE MEMB 55 56 66 TO 77 80 81
|----------------------------------------------------------------------------------|
| Member Number: 55 |
| Member Section: ST 132X132X4.8SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.703 Critical Load Case: 2 Location: 0.19 |
| Critical Condition: Sec. 9.3.2.2 |
STAAD SPACE -- PAGE NO. 7
|----------------------------------------------------------------------------------|
| Member Number: 56 |
| Member Section: ST 132X132X4.8SHS (TATA STRUCTURA SECTIONS) |
| Status: PASS Ratio: 0.702 Critical Load Case: 2 Location: 0.19 |
| Critical Condition: Sec. 9.3.2.2 |
|----------------------------------------------------------------------------------|
| Member Number: 66 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.808 Critical Load Case: 2 Location: 1.82 |
| Critical Condition: Sec. 8.2.2 |
|----------------------------------------------------------------------------------|
| Member Number: 67 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.374 Critical Load Case: 2 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |
|----------------------------------------------------------------------------------|
| Member Number: 68 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.431 Critical Load Case: 2 Location: 0.00 |
| Critical Condition: Sec. 8.2.1.2 |
|----------------------------------------------------------------------------------|
| Member Number: 69 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.431 Critical Load Case: 2 Location: 0.35 |
| Critical Condition: Sec. 8.2.1.2 |
Page 8 of 11
|----------------------------------------------------------------------------------|
| Member Number: 70 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.808 Critical Load Case: 2 Location: 0.00 |
| Critical Condition: Sec. 8.2.2 |
|----------------------------------------------------------------------------------|
| Member Number: 71 |
| Member Section: ST ISMB350 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.203 Critical Load Case: 2 Location: 0.17 |
| Critical Condition: Sec. 9.3.2.2 |
|----------------------------------------------------------------------------------|
| Member Number: 72 |
| Member Section: ST ISMB350 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.202 Critical Load Case: 2 Location: 0.17 |
| Critical Condition: Sec. 9.3.2.2 |
|----------------------------------------------------------------------------------|
| Member Number: 73 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.352 Critical Load Case: 2 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |
|----------------------------------------------------------------------------------|
| Member Number: 74 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.586 Critical Load Case: 2 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |
|----------------------------------------------------------------------------------|
| Member Number: 75 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.586 Critical Load Case: 2 Location: 0.35 |
| Critical Condition: Sec. 9.3.2.2 |
|----------------------------------------------------------------------------------|
| Member Number: 76 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.111 Critical Load Case: 2 Location: 0.00 |
| Critical Condition: Sec. 9.3.2.2 |
|----------------------------------------------------------------------------------|
| Member Number: 77 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.352 Critical Load Case: 2 Location: 0.43 |
| Critical Condition: Sec. 9.3.2.2 |
Page 9 of 11
STAAD SPACE -- PAGE NO. 10
|----------------------------------------------------------------------------------|
| Member Number: 80 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.147 Critical Load Case: 2 Location: 0.00 |
| Critical Condition: Sec. 6.2 |
|----------------------------------------------------------------------------------|
| Member Number: 81 |
| Member Section: D ISMC175 (INDIAN SECTIONS) |
| Status: PASS Ratio: 0.374 Critical Load Case: 2 Location: 0.43 |
| Critical Condition: Sec. 8.2.1.2 |
72. PARAMETER 2
73. CODE IS800 LSD
74. STEEL MEMBER TAKE OFF LIST 66 TO 70 73 TO 77 80 81
STAAD SPACE -- PAGE NO. 11
STEEL TAKE-OFF
--------------
Page 10 of 11
************ END OF DATA FROM INTERNAL STORAGE ************
75. PARAMETER 3
76. CODE IS800 LSD
77. FYLD 240000 MEMB 66 TO 70 73 TO 77 80 81
78. STP 1 MEMB 66 TO 70 73 TO 77 80 81
79. TMAIN 180 MEMB 66 TO 70 73 TO 77 80 81
80. TRACK 2 MEMB 66 TO 70 73 TO 77 80 81
81. FU 410000 MEMB 66 TO 70 73 TO 77 80 81
82. FINISH
Page 11 of 11