T Berd Mts 5800 Ethernet Bit Error Rate Testing Bert Quick References en
T Berd Mts 5800 Ethernet Bit Error Rate Testing Bert Quick References en
QUICK CARD
LAUNCH TEST
5. Tap to continue.
CONFIGURE TEST
C O N N E C T TO L I N E U N D E R T E S T
► For Optical Interfaces:
1. Use the VIAVI P5000i or FiberChek Probe
microscope to inspect both sides of every
connection being used (SFP, attenuators,
patch cables, bulkheads)
o Focus the fiber on the screen.
o If it appears dirty, clean the fiber end-face
and re-inspect.
o If it appears clean, run the inspection test.
o If it fails, clean the fiber and re-run
inspection test. Repeat until it passes.
2. If necessary, insert optical attenuators into
Figure 11: Inspect Before You Connect
the SFP TX and/or RX ports.
3. Connect the SFP to the port under test
using a jumper cable compatible with the
line under test.
4. Select the Laser tab in the Actions panel.
RUN TEST
Notes:
• The Summary/Status screen with turn red if there is a single bit error, regardless of
the Payload Error Rate threshold.
• If the test traffic is transported though any Layer 2 or Layer 3 network equipment,
including Ethernet Switches, Routers, NIDs, and Layer 2 Loopback devices, they will
drop all errored frames. This will result in multiple Bit Errors, Lost Frames, and
Pattern Losses.
+1 844 GO VIAVI
© 2023 VIAVI Solutions, Inc, Contact Us (+1 844 468-4284)
Product specifications and descriptions in this
document are subject to change without notice. To reach the VIAVI office nearest you,
T-BERD/MTS-5800
Patented as describedPortable Network Tester
at viavisolutions.com/patents visit viavisolutions.com/contact
VIAVI//Public