You are here: EPLAN Hop > Working with Connoctions » Connection symbols >
Interrupting Connections
Interrupting Connections
Autoconnecting can sometimes create unwanted connections in the
schematic (e.g., to motor overload switch auxiliary contacts). You can
interrupt these connections by inserting a break point between the
connection points. A| ‘ak point is an invisible symbol without connection
points that prevents < oconnecting or that interrupts an existing
autoconnect line.
Precondi
ns:
+ You have opened a project. You have opened a project page in the
graphical editor.
+ The page contains autoconnect lines,
1, Select the Insert tab in the ribbon.
2. In the command group Symbols click the ~ (Other) button and
below the Connectors field select the button “(Interrupt
connection).
3, Click between the two connection points on the autoconnect line to
be interrupted
> The autoconnect line is interrupted, i.e., the connection is
deleted,
4. Proceed in a similar way for all additional autoconnect lines that
are to be interrupted
5, End the action via the Cancel action popup menu item or via the
[Esc] button.