ANALYSIS GROUND STATION


V14 SR3
INSTALLATION MANUAL

3300444038-02

DROITS DE PROPRIÉTÉ INDUSTRIELLE PROPRIETARY RIGHTS


Les informations contenues dans ce document sont la propriété de Sagem This document contains information of a proprietary nature to Sagem
Défense Sécurité et diffusées à titre confidentiel dans un but spécifique. Le Défense Sécurité company and is submitted in confidence for a specific
destinataire assure la garde et la surveillance de ce document et convient purpose. The recipient assumes custody and control and agrees that this
qu'il ne sera ni copié ni reproduit en tout ou partie et que son contenu ne document will not be copied or reproduced in whole or in part, nor its
sera révélé en aucune manière à aucune personne, excepté pour contents revealed in any manner or to any person except to meet the
répondre au but pour lequel il a été transmis. Cette recommandation est purpose for which it was delivered. This legend is applicable to all the
applicable à toutes les pages de ce document. pages of this document.

Sagem is the commercial name of the company Sagem Défense Sécurité.


Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 2/57

Page left blank intentionally.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 3/57

DOCUMENT CONTROL
_________________

COMPANY NAME POSITION DATE SIGNATURE

Sagem
Established by: M. MORAL RTE
Défense Sécurité

Sagem
Authorized by: L. KOKANOSKY PO
Défense Sécurité

HISTORY OF THE DOCUMENT MODIFICATIONS


_______________

Version Date Modification Statement

01-d1 16/02/2012 Creation of document for AGS V14


01-d2 20/02/2012 Take into account of QIR-AGS-InstMan-V14_SMQNI120154
01 20/02/2012 Official Issue for AGS V14
02 24/05/2019 New Issue for AGS V14 SR2 P6

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 4/57

TABLE OF CONTENTS
_______________

Page

DOCUMENT CONTROL ....................................................................................................................................3


HISTORY OF THE DOCUMENT MODIFICATIONS ..........................................................................................3
TABLE OF CONTENTS .....................................................................................................................................4
ABBREVIATIONS ..............................................................................................................................................6
1. INTRODUCTION ............................................................................................................................................7
1.1. PURPOSE OF DOCUMENT ...............................................................................................................7
1.2. AGS CONFIGURATION ......................................................................................................................7
1.2.1. Description ...................................................................................................................................7
1.2.2. License ........................................................................................................................................7
2. SYSTEM CONFIGURATION........................................................................................................................10
2.1. SYSTEM REQUIREMENTS..............................................................................................................10
2.1.1. Workstation ................................................................................................................................10
2.1.2. Server ........................................................................................................................................10
2.2. NECESSARY SETTINGS .................................................................................................................11
2.2.1. Operating system.......................................................................................................................11
2.2.2. User privileges ...........................................................................................................................11
2.2.3. Regional settings .......................................................................................................................14
2.2.4. Graphic card ..............................................................................................................................14
2.2.5. Hard disk space .........................................................................................................................15
2.2.6. Firewall ......................................................................................................................................15
2.2.7. File system settings ...................................................................................................................15
3. BEFORE STARTING ...................................................................................................................................16
3.1. COMPONENTS REQUIRED.............................................................................................................16
3.2. OVERVIEW OF THE INSTALLATION PROCEDURE ......................................................................16
3.2.1. Case of a first installation ..........................................................................................................16
3.2.2. Case of an AGS Service Release .............................................................................................16
3.2.3. Case of a Multi-User AGS .........................................................................................................17
3.3. THE AGS DVD CONTENT ................................................................................................................18
4. INSTALLATION GUIDE ...............................................................................................................................19
4.1. STARTING THE INSTALLATION .....................................................................................................19
4.2. MONO-USER AGS CONFIGURATION ............................................................................................20
4.2.1. Working mechanisms ................................................................................................................20
4.2.2. AGS Mono .................................................................................................................................20
4.3. MULTI-USER AGS CONFIGURATION ............................................................................................26
4.3.1. Working mechanisms ................................................................................................................26
4.3.2. AGS Database ...........................................................................................................................26
4.3.3. AGS Workstation .......................................................................................................................33
4.4. ADDITIONAL OPERATION AFTER INSTALLATION ON A REMOTE WORKSTATION
(CONNECTED THROUGH LOW SPEED NETWORK) ....................................................................41
4.4.1. Local Flight Data ........................................................................................................................41
4.4.2. Local terrain files ........................................................................................................................42
4.5. WHAT GETS INSTALLED ................................................................................................................44
4.5.1. Directory structures....................................................................................................................44
4.5.2. Windows update registry ...........................................................................................................46

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 5/57


5. STARTING AGS .......................................................................................................................................... 47
5.1. STARTING MONO USER AGS ........................................................................................................ 47
5.2. STARTING MULTI USER AGS ........................................................................................................ 47
6. INSTALLING THE AGS AIRPORT DATABASE......................................................................................... 48
7. INSTALLING THE DATABASE VERSIONS ............................................................................................... 49
8. USING THE TRAINING DATABASE .......................................................................................................... 50
9. PRE-DEFINED CONFIGURATION .............................................................................................................. 51
10. INSTALLATION OF SEVERAL DATABASES ON SERVER ................................................................... 52
10.1. PURPOSE ......................................................................................................................................... 52
10.1.1. Separate fleet ............................................................................................................................ 52
10.1.2. Historical database .................................................................................................................... 54
10.2. DATABASE MANAGEMENT ............................................................................................................ 55
10.2.1. Purpose ..................................................................................................................................... 55
10.2.2. Advice for the management for several Database .................................................................... 55
10.3. HISTORICAL DATABASE MANAGEMENT ..................................................................................... 56
10.3.1. Historical database creation ...................................................................................................... 56
10.3.2. Access to historical database on a workstation ........................................................................ 56
10.3.3. Historical database update ........................................................................................................ 56
10.3.4. Historical database backup ....................................................................................................... 56

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 6/57

ABBREVIATIONS
_______________

ADM AGS Database Management


AGS Analysis Ground Station
APMS Aircraft Performance Monitoring System
AQD Aviation Quality Database

CAPS Common Airline Procedure Set

DB DataBase
DBISQL SAP SQL Anywhere tool allowing database editing through SQL commands

FDAU Flight Data Acquisition Unit


FFT Fiche de Fait Technique
FOQA Flight Operation Quality Assurance

IEEE Institute of Electrical and Electronics Engineers


IHM Interface Homme Machine

MOQA Maintenance Operation Quality Assurance


MPC Multi Purpose Computer

N/A Non Applicable

QAR Quick Access Recorder

REQ REQuirement
RFF Realized Flight File

SMS Safety Management System


STD STandarD
SYS SYStem

TBD To Be Defined

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 7/57


1. INTRODUCTION

1.1. PURPOSE OF DOCUMENT


This document provides the information you need to install the SAGEM Analysis Ground Station (AGS)
V14 SR2 P7.
It concerns both the first installation and the AGS upgrade (including the database).

1.2. AGS CONFIGURATION


The AGS is a powerful modular tool for flight data analysis. According to your needs, 2 main system
configurations are available:

1.2.1. Description
AGS Configuration AGS Configuration Description

Mono User Single PC desktop system called AGS workstation

Multi User PC LAN client/server system composed of 1 server and several AGS
workstations

1.2.2. License
The AGS software application is available under several license types described below:

AGS "XL" Expert

AGS "L" Report Builder

AGS "M" Analyst

AGS "S" Viewer 3D

AGS "S" Viewer


 Manual Analysis

 3D bundle

 Automatic Analysis
 Import / Validate DB version
 Modify limt & trend file name
 Manage Fleet & Admin
 Refresh Stat Reports

 Create Stat Reports

 Full Programming

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 8/57


 AGS VIEWER
 Flight data display by importing Engineering Data Files (Stand Alone) or by database access (Server
Client Configuration)
 Export of Engineering Data (xls, csv to CEFA software)
 Display configuration management
 Video generation (avi files)
 Study access in Server Client Configuration
 AGS VIEWER 3D
 Same functions as AGS VIEWER
 3D bundle
 AGS ANALYST
 Same functions as AGS VIEWER
 Flight data analysis launching (Media, Autonomous), Flight Replay
 Event validation
 Procedures limits modification, Procedures activation or not
 Database versions validation
 Fleet creation
 Administration access (Users management…)
 Read-only access to other functions (Procedures code, Statistic Report Builder….)
 AGS REPORT BUILDER
 Same functions as AGS ANALYST
 Update statistical reports
 Create your own statistics reports
 AGS EXPERT
 Same as AGS REPORT BUILDER + full access to procedures programming
 Full access to AGS functions

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 9/57


The principle of each working mode is described in the following table :

Working Mode Working Mode Description

Determined License mode

A Determined License is designed to run on a single registered


workstation. It is a standalone license; the workstation does not need
to be connected to a network to register its license.
Concurrent License
mode

A Concurrent License mode is designed to allow from one up to a


predefined number of simultaneously connected workstations to run
the application (according to the number of users purchased). The
Concurrent License Service shall be installed on the AGS Server
(but the service must not be installed on an AGS workstation).
Note: each workstation that needs to run the application must stay
connected to the network (to the AGS Server, that acts as a license
server) as long as the application is being executed.
Note: the application installation and usage does not depend of the type of working mode. The only
difference between a Determined License and a Concurrent License is the location of the access key:
 With a Determined License, the access key is located on the workstation,
 With a Concurrent License, the access key is located on the AGS Server (on which will run the
License Server).

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 10/57


2. SYSTEM CONFIGURATION

2.1. SYSTEM REQUIREMENTS


Please, read this section to make sure you are ready to begin the install.
According to your AGS configuration (Mono/Multi), please find below the recommended hardware
requirements and the mandatory software configuration:

2.1.1. Workstation
WORKSTATION
Mono User AGS Multi User AGS
CPU INTEL I7 or AMD Athlon 64 X2
Hard Disk 250 GB SSD SATA 6Gb/s (Read speed >= 540 MB/s, Write speed >= 500 MB/s)
Memory 64 GB DDR4
Graphic Card nVidia GeForce GTX 1060 (*)
AMD Radeon RX 500 (*)
Network 1 Gb/s – Latency < 10 ms
Drives DVD+/-RW Single Layer or Dual Layer
Device Screen, Keyboard, Wheel Mouse
Operating System Windows 7 SP1 or Windows 10
Others .NET Framework v4.6.1 (or higher)

2.1.2. Server
SERVER
(Multi User AGS only)
CPU INTEL Xeon or AMD Phenom X4
Hard Disk 500 GB SSD SATA 6Gb/s (Read speed >= 540 MB/s, Write speed >= 500 MB/s)
Memory 64 GB DDR4
Screen Resolution 1024 x 768
Network 1 Gb/s – Latency < 10 ms
Drives DVD-ROM Single Layer or Dual Layer
Device Screen, Keyboard, Wheel Mouse
Operating System Windows Server 2008 R2 or Server 2012 R2 or Server 2016 or Server 2019

(*) For the 3D view. OpenGL 3.0 and later is required. In most cases, graphic card driver updates contain
the latest version of OpenGL.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 11/57


2.2. NECESSARY SETTINGS

2.2.1. Operating system


The AGS only works on the operating systems defined above. If it is not the case, an error message is
displayed and the installation is aborted.

2.2.2. User privileges

2.2.2.1. During AGS installation


During installation, a user with "Local Administrator" privilege is required because the Windows
configuration will be updated (Windows folders, registry).

2.2.2.2. During AGS using

2.2.2.2.1. Folder permissions


During AGS using, the following folders security must be configured to allow the "Full control" to AGS
users:
- Temp folder
- Trend output folder
- Win XP:
- Program Files\Sagem\AGS
- Program Files\Sagem\B3D
- Program Files\Business Objects
- Documents and Settings\All Users\Application Data (*) (used by BusinessObjects)
- Win 7:
- Program Files (x86)\Sagem\AGS
- Program Files (x86)\Sagem\B3D
- Program Files (x86)\Business Objects
- ProgramData\Business Objects
(*) Note: to see this folder before modifying security access, the following Folder Options must be
selected:

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 12/57


2.2.2.2.2. Registry permissions
During AGS using, the following key in the registry must be configured to allow the "Full control" to
AGS users:
- HKEY_LOCAL_MACHINE\Software\ODBC
- HKEY_LOCAL_MACHINE\Software\Sagem
- HKEY_LOCAL_MACHINE\Software\Business Objects
For that, a local administrator must launch REGEDIT program, go to the key defined above, use right
click menu "Permissions", select the user group and activate the "Full control"

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 13/57

-
-

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 14/57


2.2.3. Regional settings
To work properly, the AGS need the Windows’ regional settings to be in a certain configuration:
 The Decimal symbol must be ".".
 The Digit grouping symbol must be "," or blank.
 The Negative sign symbol must be "-"
If it is not the case a message will be displayed. By clicking “Yes” the installation program will change
your configuration. Click “No” to abort the installation.

2.2.4. Graphic card


 The new 3D view function requires a graphic card with at least a compatibility with OpenGL version 1.5
(*). If it is not the case a message will be displayed. By clicking “Yes” the installation program will
continue without installing the 3D view function. Click “No” to abort the installation.

Warning about remote AGS upgrade

The 3D view cannot be installed if you launch the AGS upgrade (from DVD or with
Service Release program) through Microsoft Windows Remote Desktop, as this program
do not use the 3D card.

(*) The minimum configuration consists in Nvidia GeForce Serie 6 graphic cards (recommended:
GeForce Serie 8). ATI cards - at least 9600 Pro - can also be chosen but we highly recommend
Nvidia which have more stable drivers.
 The color quality must be set to Highest (32bit) as described below. The check is perfomed at AGS
entry.

 Concerning Nvidia control panel used in Advanced settings mode, in the Adjust Desktop Color Settings,
the graph must be linear and must cover the full range as described below (otherwise, it is possible that
several colors cannot appear clearly like the drag area for zooming in Curves module which remains
blank):

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 15/57

 It is strongly advised to update the display driver with the latest stable one

2.2.5. Hard disk space


An error message is displayed if the hard disk(s) do(es) not include the following spaces:

Path Minimum space in GB


Program Files 1
Application Path 4
Database Path 7
Flight Data Path (*) 1
Deployment Path 5
(*) The Flight Data Path size must be defined according to the quantity of flight data to be analyzed for
the period required by the customer.

2.2.6. Firewall
The installation can be disturbed if there is a firewall activated during the process. So, the setup program
will do the followings:
 Case of Microsoft firewall: the system will propose to stop the firewall if activated. If it is not
possible to stop it, the installation will stop.
 Case of other firewall: a warning message will be displayed recommending to turn off any
firewall during the installation

2.2.7. File system settings


The file short names (like "PROGRA~1" for "Program Files") must be activated so that AGS could
work. If it is not the case, the setup program will change automatically this setting.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 16/57


3. BEFORE STARTING
This section supposes you have configured your system as defined in previous chapter 2.

Remind about AGS update

In case of an AGS update (only possible from the previous AGS version), please
perform a backup of your AGS database and export to external files the statistic reports
managed as "Corporate Documents" (if necessary).

3.1. COMPONENTS REQUIRED


To install the AGS application, you need several components provided by SAGEM:
 The AGS installation manual,
 The AGS DVD,
 The AGS access key(s) (according to the type and number of licenses purchased) (*),
 The AGS license file,
 The AGS database version(s) (option).

(*) The access key defines the AGS software license (see chapter 1.2).
To run the AGS application, the AGS access key must be plugged on the current workstation (determined
license) or on the license server (concurrent license, with dedicated service running).

Warning about AGS access key

In case of failure, SAGEM will send a new access key to the customer as soon as the
faulty access key will be returned to SAGEM.

3.2. OVERVIEW OF THE INSTALLATION PROCEDURE

3.2.1. Case of a first installation


In case of a first installation on a PC, the installation procedure consists in:
 Checking the configuration of the operating systems before the AGS installation (see
Chapter 2. ),
 Installing the AGS from the DVD (see Chapter 4. ),
 Installing the AGS airport database (see Chapter 6. ).
 Installing (if necessary) the database version(s) delivered by SAGEM (see Chapter 7. ).

3.2.2. Case of an AGS Service Release


An AGS Service Release is a single file which contains minor revision of the AGS (with bug
correction). It can be downloaded from the AGS web site (http://www.sagem-ds.com/ags).
 Making a backup of the current AGS Database, and to export to external files the statistic reports
managed as "Corporate Documents" (if necessary),
 Installing the Release (launch the corresponding program file),
Note: If you have chosen the release deployment option when you have installed the workstations, you
just have to install the release on the ”Workstation Master”. Restart the slave workstations, they
will be automatically updated.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 17/57


3.2.3. Case of a Multi-User AGS
In case of a multi-user AGS, the following operations must be performed:

 On the server:
 Installation of the AGS Database
 In case of concurrent license (protection key on the server), installation of the AGS License Server

 On all the workstations: Installation of the AGS Workstation

Remind: The AGS DVD can be used to install either a mono-user or a multi-user AGS or both.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 18/57


3.3. THE AGS DVD CONTENT
The AGS DVD contains components that are needed to run the Mono User AGS or the Multi User AGS:

Warning about runtimes

Delivered runtimes (Powerbuilder®, Graphics Server®, Open Watcom C compiler, SAP


SQL Anywhere®, Dynazip®, GMS®) are limited to the usage of the AGS application only
and cannot be used for any other purpose.

AGS DVD TREE STRUCTURE

\--+ AGS Setup Program


|
|-- B3D 3D Bundle
|
|-- Doc AGS documentation (Installation Manual, …)
|
|-- Install Setup program for each module
|
+-- Tools Refers to tools like “Parameter Rename” described
in the User’s Manual Chapter 8

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 19/57


4. INSTALLATION GUIDE

The AGS Setup program installs the AGS software in default drives and directories. Dialogs allow you to
modify the default configuration.
 Exit all the programs which are running. If you do not, the Setup program will not be able to
copy some files in Windows directories.
 Insert the AGS DVD in the DVD drive.
 Start the Setup program by using one of the following methods:
 In Windows Explorer, display the file list of the AGS DVD and double-clicking SETUP.EXE,
 In Windows "Start" menu, select "Run..." item and type X:\SETUP.EXE where X is the DVD
drive letter.
Then, the AGS Setup program displays the setup manager screen:

4.1. STARTING THE INSTALLATION

The setup Manager let you choose between the


different AGS installation types. To make a choice, just
select the blue link that matches your need. Or you
can also press the button on the bottom-right corner to
leave the installation process.

Remark: To work properly, the AGS needs the Windows’ regional settings to be in a certain configuration. If it
is not the case a message will be displayed. By clicking “Yes” the installation program will change
your configuration. Click “No” to abort the installation.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 20/57


4.2. MONO-USER AGS CONFIGURATION

4.2.1. Working mechanisms


In a mono-user configuration, the AGS works as a stand-alone station which have all the AGS
components. As soon as the installation program has finished preparing the station, the AGS can be used.

4.2.2. AGS Mono

4.2.2.1. Installation

Welcome

Reading this screen you can be sure that you are


about to install AGS Mono. Click Next to go to the first
step of the installation.

4.2.2.1.1. License Agreement

Read the license agreement. If you want, you can print


it by clicking the “Print” button. Select the first line to
accept the agreement and click “Next”.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 21/57


4.2.2.1.2. Company and Workstation Name

At this step, you just have to enter the name of the


airline/company the Database will refer to and give a
name to your workstation (up to 6 characters).

4.2.2.1.3. AGS Application Path

You have to indicate where you want AGS Mono


application to be installed.

Advice: It is possible after the end of installation to change the location of the working directory to improve
the performance. For that, the following key of the

HKEY_LOCAL_MACHINE\Software\Sagem\AGS\AGSMono\Workdir = "X:\Work"

4.2.2.1.4. Database Path

You can indicate here a path to the database


associated to the AGS Mono.
By default, the path is the same than the application
but it can be located on another disk (ex:
D:\Sagem\AGS).

In case of migration from AGS 2006, the default path


is chosen to have the database in the same disk than
previously.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 22/57


4.2.2.1.5. Flight Data Path

You can indicate here a path to the flight data stored


during flight input.
The path includes the last folder level.
Example of path:
 C:\Program Files\Sagem\AGS\AGSMono\FltData
 D:\FltData

By default, the path has the same root than the


application but it can be located on another disk.

In case of migration from AGS 2006, the default path


is the same than previously.

4.2.2.1.6. Start Menu Configuration

At this step, you can select the Start Menu folder in


which the AGS’ shortcut will be placed. Check the
Database Management option if you want to use AGS
database management software.

Remark: It is strongly advised to manage locally the raw data and to backup the raw data locally. So, the
database management should be used in this workstation.
4.2.2.1.7. Protection Key Type

For security reasons, the AGS cannot work without a


protection. It is highly recommended to choose a
digital license called RLM as the USB key is
deprecated
.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 23/57


4.2.2.1.8. Terrain File Installation

This option allows installing the terrain files containing


elevation database and Landsat imagery.
It takes approximately 2 GB on the disk.
If the files are not installed, the 3D view will only
display a world "blue marble" in very low resolution
and the terrain will not be displayed using elevation
(no relief).

Check the box and click “Next” to continue the


installation.

Note: The terrain files can be installed later, in "Modify"


mode.

4.2.2.1.9. Summary

This is the last screen before the installation begins.


You can check if all given information are right. When
you are ready, click “Install”.

Remarks:
 The installation start by copying files in a temporary directory; you can cancel the installation while this
step is not finished. After, the installation cannot be stopped.
 The installation creates a training version (called AGS Training Mono) to learn how to use the AGS.

4.2.2.1.10. Installation Process


Let the program install the AGS components. When the process is finished, restart the computer and
plug the protection key.

4.2.2.2. Modify/Repair/Remove

4.2.2.2.1. Welcome
If AGS Mono is installed, you can modify or remove it. Modify action can be useful for repairing
application files or in case of a new 3D graphic card. In this case, the 3D module is installed and
activated.
Launch the installation, this screen will be displayed:

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 24/57

By selecting “Modify”, you can change your current


configuration.
By selecting “Repair”, you can reinstall the software
(but not the runtimes). The DVD is necessary at this
level.
By selecting "Remove", you can uninstall the AGS
Mono

4.2.2.2.2. Modify

4.2.2.2.2.1. Database selection

You can select the database you want to modify (the


different AGS Mono and the Training Mono).
The installed Mono database and their current version
(database and software which are normally the same)
is displayed
All the databases are selected by default.
Click "Next" to continue.

4.2.2.2.2.2. Modify Company and Workstation Name

You can change the company or the workstation


name. Click “Next” to change the protection key driver
if it is necessary. The installation will Change the AGS
Mono configuration. Restart the computer.

4.2.2.2.2.3. Other options


You can change the terrain file installation option. Read the summary screen and click on the “Install”
Button. The installation will change the configuration. Restart the computer.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 25/57


4.2.2.2.3. Repair
In case of binary or data file missing or corrupted, you can reinstall the AGS software installed by the
previous major setup (but not the drivers and runtimes).
At the end of this operation, if you had a service release previously installed, you must instal it again to
complete the repair.
Note: The repair has to be selected in the case of graphic card change to meet 3D requirement.

4.2.2.2.4. Remove
You have to backup your database and the flight data before removing AGS if you want to use later the
work you have made,
Then, you have to confirm the remove by answering “yes” to the next message. All components will be
deleted (including all the databases, flight data and configuration files).

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 26/57


4.3. MULTI-USER AGS CONFIGURATION
If you want that the flight data can be used by different stations, then you have to install the AGS in the
multi-user mode.

4.3.1. Working mechanisms


In a multi-user configuration, the AGS acts as a client-server application. Thus, it is necessary to use two
different programs:
 the AGS Database (server part),
 the AGS Workstation (client part).
Warning about installation steps

AGS Database has to be installed first. As soon as this part of AGS is running on the
server, the database is available and can be used by all the clients.
So, all the workstations must exit the AGS before starting the database installation.
During the process, the installation program will STOP THE DATABASES that are
running on the server.
Then you can install the AGS Workstation on each station you need.

4.3.2. AGS Database

4.3.2.1. Installation

4.3.2.1.1. Welcome

Reading this screen you can be sure that you are


about to install AGS Database. Click Next to go to the
first step of the installation.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 27/57


4.3.2.1.2. License Agreement

At this step, read the license agreement. If you want,


you can print it by clicking the “Print” button. Select the
first line to accept the agreement and click “Next”.

4.3.2.1.3. Setup Type

This screen let you choose different options. If it is the


first installation, you can create a new database.
Select “Create Database” and click the “Next” button. If
the AGS Database has been installed but you want to
change the configuration, select “Modify Database
setting”.

4.3.2.1.4. Company Name

At this step, you just have to enter the name of the


airline/company the Database will refer to.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 28/57


4.3.2.1.5. AGS Database Path

You have to indicate where you want AGS Database


to be installed. All AGS’ files will be there.
Keep in mind that this folder must be reachable by the
workstations. In our example we have created a folder
called “Apps” on the “D:” drive before launching the
installation.
This folder has to be shared to give all workstation the
rights to write on it. In the folder properties, select
"Share this folder” with the option “Maximum allowed”.
The “D:\Apps\SAGEM\AGS” will be created by the
installation program if necessary.

4.3.2.1.6. Database information

This screen allows changing the default options of the


Database (if necessary) before installing the AGS.

Field Meaning Default Value


Database The name of the Database which will be used. After, the program will add the AGS prefix. Multi
Name (Multi  AGSMulti)
Engine This engine is a SAP SQL Anywhere program which manages the AGS database. It can be ENGAGSMulti
Name changed but it is clearer to let it as Sagem proposed.
Port When the engine is running, it is waiting requests from the workstations on the chosen port 2638
number. In case of multiple databases, Sagem search the appropriate port number.
Cache The amount of memory (in MB) available for use as a database server cache is one of the 128M
Size key factors controlling performance. The more cache memory that can be given the server,
the better its performance.
Flight Allows defining the raw data (recorded flight data). \\Server_AGS\Apps\
Data This option has been made to let the possibility to store Flight Data in a different location SAGEM\AGS\AGS
Folder than the AGS Database. Multi\Fltdata
The path must be accessible by all workstations so it has to begin by:
 a valid server name (recommended solution)
 or IP address (in case of problem with server name method). But in this case, the
server IP address should be a fixed IP address.
From the workstations, the connected user must have the right to write on this folder. Here,
“Apps” is the share name defined in the precedent step of the installation

Note: according to the configuration, a problem of flight data storage can occur at the end
of the flight input.
This problem is visible when the flight display does not show any data.
In this case, it is necessary to map a driver letter to all the workstation
See § AGS Workstation for more details.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 29/57


4.3.2.1.7. Summary

This is the last screen before the installation begins.


You can check if all given information are right. When
you are ready, click “Install”. When the installation is
finished, restart the computer.

Remark: The installation start by copying files in a temporary directory; you can cancel the installation while
this step is not finished. After, the installation cannot be stopped.

4.3.2.2. Modify/Repair/Remove

4.3.2.2.1. Welcome
If AGS Database is installed, you can modify or remove it. Launch the installation, this screen will be
displayed:

By selecting “Modify”, you can change your current


configuration.
By selecting “Repair”, you can reinstall the runtime and
terrain files (if any). The DVD is necessary at this level.
By selecting "Remove", you can uninstall the AGS
Database including all the different databases.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 30/57


4.3.2.2.2. Modify

4.3.2.2.2.1. Setup Type

Select “Modify Database Setting” and click “Next”.

4.3.2.2.2.2. Modify Company Name

If it is necessary, you can change the name of the


company.

4.3.2.2.2.3. Modify Database information

This screen displays the current information of the


Database.

It is possible to change the port number, the size of the


cache that will be used and the Flight data folder

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 31/57

Click on the “Save” button to make a record of your


changes. If the fields become empty, you can be sure
that the save process is successful.

Click “Next” to continue the installation as usual. The


program will change the configuration of the AGS
Database. Restart the computer.

Modification of port number


 When the port number is modified at this level, this modification is also automatically done on the
workstation (trough the AGS database configuration file)

Modification of Flight Data Folder


 It can be useful to transfer the flight data from one computer to another one or to declare a new name
for the server
 The setup program will accept the new location if it is available
 It will operate the transfer if the previous location is available
 It also manages the case of simple server name rename with the flight data staying at the same
location. In this case, no transfer is performed as the previous location is no longer available.

Remarks:
 If you click on the line of the database, all information will be displayed again.
 If you click next before the modifications have been saved, the program will ask you if you want to
record your changes. Click “Yes” to continue or “No” to cancel

4.3.2.2.3. Repair
In case of binary or data file missing or corrupted, you can reinstall the software. The DVD is
necessary at this level.

4.3.2.2.4. Remove
You have to backup your database and the flight data before removing AGS if you want to use later the
work you have made,
Then, you have to confirm the remove by answering “yes” to the next message. All components will be
deleted (including all the databases, flight data and configuration files).

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 32/57


4.3.2.3. Several Databases
It you want to use more than one Database, it is possible to create as many as you need.
After the first database is in place, repeat the installation process and create a new database.
Select Modify at the “Welcome” screen, then “Create Database” and choose the name of the
company.
The program will display the database(s) already installed and the default database options for the
new database.

When you have finish to give information, click “Next”


and “install”. Repeat this operation for all new
databases you need. Restart the computer each time.

Remark: The “Database Name”, the “Engine Name” and the “Port” must be different for each database

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 33/57


4.3.3. AGS Workstation
Before you begin to install the AGS Workstation, make sure that AGS Database is running on the
server. If you plan to use more than one database, create all the databases on the server first.

4.3.3.1. Installation

4.3.3.1.1. Welcome

Reading this screen you can be sure that you are


about to install AGS Workstation. Click Next to go to
the first step of the installation.

4.3.3.1.2. License Agreement

At this step, read the license agreement. If you want,


you can print it by clicking the “Print” button. Select the
first line to accept the agreement and click “Next”.

4.3.3.1.3. Workstation Name

Choose a name for this workstation (up to 6


characters) and click “Next”.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 34/57


4.3.3.1.4. AGS Workstation Path

Here you have to indicate where you want AGS


application to be installed. All AGS’ files will be there.
If you want to change the default path click “Browse”,
select the correct path, click on the “Ok” button then
“Next” to continue the installation.

Advice: It is possible after the end of installation to change the location of the working directory to improve
the performance. For that, the following key of the

HKEY_LOCAL_MACHINE\Software\Sagem\AGS\AGSMono\Workdir = "X:\Work"

4.3.3.1.5. Start Menu Configuration

At this step, you can select the Start Menu folder in


which the AGS’ shortcut will be placed.
Check the Database Management option if you want
to use AGS database management software on the
workstation but generally, the database management
is done on the server.

4.3.3.1.6. Database Path

To communicate, with the server, the AGS


Workstation needs to know where the AGS Database
is installed. Select the path by clicking on the “Browse”
button. In our example, a database is installed on the
“Server_Ags” server in “Apps\SAGEM\AGS\”.

To reach the location, a network drive must be

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 35/57


mapped. Open the Windows’ Explorer (“Start Menu”
then “My Computer”) Choose “Tools Menu” and “Map
Network Drive” item.
In our example the drive is “P:” and the folder is
“\\Server_Ags\Apps\”. So the Database Path becomes:
P:\SAGEM\AGS. If the path is correct, the screen
displays the database information.

If the server provides multiple databases, the screen


will display them. Select the databases you want this
workstation to work with.

4.3.3.1.7. Deployment option


The deployment option has been designed to avoid wasting time in the workstation updating process.
Sagem provides its customers with updates for the AGS. If you use many workstations, you should
use this option. You update one Workstation (we call it the Workstation Master) and the others
workstation (we call them Slave Workstations) will be updated when they will be restarted.

Remark: This option has to be chosen at the first installation and will be available for the next updates. The
first time, all workstation must be installed manually.

If you do not plan to use this option, select the first line
and click “Next”.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 36/57

If you are interested by the automatic deployment,


select the second option.
You have to choose the folder where files of the next
releases will be stored (the same in all the
workstations).
When you will receive an update, install it on any
workstation.
The other workstations will be updated on Windows
restart after a confirmation message.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 37/57


Deployment overview

Server Once the master has copied


The workstation
the release on the server,
master will copy
the slave workstations will
the release on
be automatically updated at
the server
restart

P:\SAGEM\AGS\UPDATE

Automatic

Installation of the
next releases on
this station

Master Workstation Slave Workstations

4.3.3.1.8. Protection Key Type

For security reasons, the AGS cannot work without a


protection. It is highly recommended to choose a
digital license called RLM as the USB key is
deprecated
.

Warning about protection key type selection

If you choose skip during the migration process, the AGS will not work properly.

Warning about USB protection key

The USB protection key must not be plugged during the installation process. It can
be plugged after the installation and PC reboot.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 38/57


4.3.3.1.9. Terrain File Installation
This option allows installing the terrain files containing
elevation database and Landsat imagery.
It takes approximately 2 GB on the same disk than the
database.
If the files are not installed, the 3D view will only
display a world "blue marble" in very low resolution
and the terrain will not be displayed using elevation
(no relief).
Check the box and click “Next” to continue the
installation.

Note 1: The terrain files are installed once, on the first


workstation where this option is activated.
Note 2: the terrain files can be installed later, in
"Modify" mode.

4.3.3.1.10. Summary

This is the last screen before the installation begins.


You can check if all given information are right. When
you are ready, click “Install”.

Remark:
 The installation starts by copying files in a temporary directory; you can cancel the installation while
this step is not finished. After, the installation cannot be stopped.
 The installation creates a training version (called AGS Training Multi) to learn how to use the AGS.

4.3.3.1.11. Installation Process


Let the program install the AGS components. When the process is finished, restart the computer and
plug the protection key.

Warning about flight data storage problem

According to the configuration, a problem of flight data storage can occur at the end of
the flight input. This problem is visible when the flight display does not show any data.
In this case, it is necessary to map a driver letter to all the workstation.
For instance, the drive letter R: can be used to map the flight data path defined during
AGS Database installation (ex: \\Server_AGS\Apps\SAGEM\AGS\AGSxxxx\Fltdata)
This same letter must be used in all the workstation.
Then, the flight data path must be replaced by the driver letter:
- in the registry of the workstation already installed

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 39/57


[HKEY_LOCAL_MACHINE\Software\ Sagem\AGS\AGSxxxx\fltdatadir]
- in the following file on server: P:\SAGEM\AGS\AGSDBLIST.TXT (useful for the
installation of the next workstations)

4.3.3.2. Modify/Repair/Remove

4.3.3.2.1. Welcome
If AGS Workstation is installed, you can modify or remove it. Modify action can be useful for repairing
application files or in case of a new 3D graphic card. In this case, the 3D module is installed and
activated.
Launch the installation, this screen will be displayed:

By selecting “Modify”, you can change your current


configuration.
By selecting “Repair”, you can reinstall the AGS
software installed by the previous major setup (but not
the drivers and runtimes).
By selecting "Remove", you can uninstall the AGS
Workstation including the access from the workstation
to all databases on server.

4.3.3.2.2. Modify

4.3.3.2.2.1. Modify Workstation Name

If it is necessary, you can change the name of the


workstation.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 40/57


4.3.3.2.2.2. Modify Database Path

You can choose the database you want. Click “Next”


to continue the installation.

Warning about database selection

The databases selected will be kept or installed. The others will be removed. A
message will be displayed to warn you about that. Click “Yes” to continue or “No” to cancel.

4.3.3.2.2.3. Other options


You can change the Workstation’s type of deployment, the protection key driver and the terrain file
installation option. Read the summary screen and click on the “Install” Button. The installation will
change the configuration. Restart the computer.

4.3.3.2.3. Repair
In case of binary or data file missing or corrupted, you can reinstall the AGS software installed by the
previous major setup (but not the drivers and runtimes). At the end of this operation, if you had a
service release previously installed, you must install it again to complete the repair.
Note: The repair has to be selected in the case of graphic card change to meet 3D requirement.

4.3.3.2.4. Remove
You have to backup your database and the flight data before removing AGS if you want to use later the
work you have made,
Then, you have to confirm the remove by answering “yes” to the next message. All components will be
deleted (including training database + flight data and all configuration files).

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 41/57


4.4. ADDITIONAL OPERATION AFTER INSTALLATION ON A REMOTE
WORKSTATION (CONNECTED THROUGH LOW SPEED NETWORK)
This chapter concerns an AGS remote workstation connected to a server through a low speed
network.

4.4.1. Local Flight Data


We strongly advise to manage locally the stored flight raw data in a workstation disk, in order to
decrease the time to analyse flight data (Function Engineering data display and Replay)

4.4.1.1. How to configure local flight data path


For that, please follow this procedure:
 After the AGS Installation, please modify the registry and add the following string key:

HKEY_LOCAL_MACHINE\SOFTWARE\SAGEM\AGS\<Database Name>
local_fltdatadir=C:\FLTDATAL

where <Database Name> is the name chosen for the database; like AGSMulti

Example of Registry with AGSMulti:

 To create the flight data directory, select the "Run..." item in the Windows "Start" menu, and
execute the command

"<Program Files>\SAGEM\AGS\<Database Name>\MKFLTDIR C:\FLTDATAL"

where <Program Files> is to be replaced by the Program Files folder


Notes:
 In all the workstations (remote or not), the AGS searches first for a local flight data directory, and if
not found, will take the server flight data directory.

4.4.1.2. How to synchronize flight data with server


It is necessary to synchronize the flight data between local path and server one:
 From local path to server to add the new locally analyzed flight data to the server
 From server to local path to be able to analyze flight added in the server

For that, any synchronization tool can be used, like the free tool SyncBack which allow synchronizing
two folders in a scheduled task (for instance, every hour or every night).

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 42/57


4.4.2. Local terrain files
We strongly advise to manage locally the terrain files in a workstation disk, in order to decrease the
time to access to graphic functions (All except Tabular Data)

4.4.2.1. How to configure local terrain files


As shown in the following example, we advise to:
 Use the B3D folder under the binary folders for the copy of Jeppesen AGS Airports
ex: <Program Files>\SAGEM\AGS\<Database Name>\B3D\AGSAirports
 Create a B3D folder besides the binary folders
ex: <Program Files>\SAGEM\AGS\B3D

1) Modify the <Program Files>\SAGEM\AGS\<Database Name>\B3D\General\Default.xml file:


...
<!-- Configuration for directories -->
<!-- This part defines the location of each directory -->
<Directories lockTimeOutInSeconds="600">
<SharedLocal url="./B3D" />
<SpecificNetwork url="<Program Files>\SAGEM\AGS\<Database Name>\B3D" />
<SharedNetwork url"<Program Files>\SAGEM\AGS\B3D" />
</Directories>
...

2) Copy the server files to local path:


 XCOPY /s P:\SAGEM\AGS\<Database Name>\B3D\AGSAirports
<Program Files>\SAGEM\AGS\<Database Name>\B3D\AGSAirports

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 43/57


 XCOPY /s P:\SAGEM\AGS\B3D <Program Files>\SAGEM\AGS\B3D

4.4.2.2. How to synchronize terrain files with server


It is necessary to synchronize the terrain file between local path and server one:
 To share the new charts
 To update in the local folder the new terrain file in the server, in case of AGS software update

For that, the same kind of tool than previous chapter (local flight data) can be used.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 44/57


4.5. WHAT GETS INSTALLED

4.5.1. Directory structures


The default installation places the AGS components in different directories as follow:
4.5.1.1. Mono User AGS configuration:
C:\Program Files\Sagem\Ags\
|
+-- AGSMono Software and Database Location
| |-- B3D Ags 3D bundle
| | |-- AGSAirports Jeppesen database export for bundle
| | |-- General Configuration, A/C, Mapping
| | |-- Geodata
| | |-- GUI Menu, pictures
| | |-- Temp
| | |-- Tools
| | +-- UndoRedo
| |-- CONFIG Memorization of configuration files
| |-- FLTDATA Flight data location
| | |-- T0
| | |-- Ti
| | +-- T9
| |
| |-- FLTREC
| | +-- A320
| | +-- 10385 Data file for AGS training
| |-- LOGO Pre-defined logo in AGS report
| |-- OBPM Executable files for the analysis
| |-- RDB Relational database files
| |-- SET Pre-defined configuration (report, parameter set, ..)
| +-- WORK Working space
|
+-- AGSTrainingMono Software and Database Location
| |-- B3D Ags 3D bundle
| | |-- AGSAirports Jeppesen database export for bundle
| | |-- General Configuration, A/C, Mapping
| | |-- Geodata
| | |-- GUI Menu, pictures
| | |-- Temp
| | |-- Tools
| | +-- UndoRedo
| |-- CONFIG Memorization of configuration files
| |-- FLTDATA Flight data location
| | |-- T0
| | |-- Ti
| | +-- T9
| |
| |-- FLTREC
| | +-- A320
| | +-- 10385 Data file for AGS training
| |-- LOGO Pre-defined logo in AGS report
| |-- OBPM Executable files for the analysis
| |-- RDB Relational database files
| |-- SET Pre-defined configuration (report, parameter set, ..)
| +-- WORK Working space
|
+-- B3D
|-- 3D
| |-- Aircrafts Aircraft models
| |-- Airports Runways, taxiways marking
| |-- BMNG Blue Marble images
| |-- Landsat LandSat images
| +-- SRTM Terrain elevation
|-- Airports
| |-- Charts Chart used for each airport
| |-- Customs Customer points
| |-- Navaids Waypoints
| +-- Taxiways Taxiway data
|-- Charts Chart and their geo-ref data
|-- Cockpit Cockpit models
+-- Xairports Xplane airport database

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 45/57


4.5.1.2. Multi User AGS configuration:
  On the workstations:
C:\Program Files\Sagem\Ags\
|
+-- <Database Name> Software location
| |-- B3D AGS 3D bundle
| | |-- General Configuration, A/C, Mapping
| | |-- Geodata
| | |-- GUI Menu, pictures
| | |-- Temp
| | |-- Tools
| | +-- UndoRedo
| |-- CONFIG Memorization of configuration files
| |-- OBPM Executable files for the analysis
| +-- WORK Working space
.
. (as many database(s) installed)
.
|
|-- AGSTrainingMulti Software and Database Location
|-- B3D AGS 3D bundle
| |-- AGSAirports Jeppesen database export for bundle
| |-- General Configuration, A/C, Mapping
| |-- Geodata
| |-- GUI Menu, pictures
| |-- Temp
| |-- Tools
| +-- UndoRedo
|-- CONFIG Memorization of configuration files
|-- FLTDATA Flight data location
| |-- T0
| |-- Ti
| +-- T9
|
|-- FLTREC
| +-- A320
| +-- 10385 Data file for AGS training
|-- LOGO Pre-defined logo in AGS report
|-- OBPM Executable files for the analysis
|-- RDB Relational database files
|-- SET Pre-defined configuration (report, parameter set, ..)
+-- WORK Working space

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 46/57


 On the Server:
P:\Sagem\Ags\
|
|-- <Database Name> AGS database location
| +-- B3D
| | +-- AGSAirports Jeppesen database export for bundle
| +-- CONFIG Memorization of configuration files
| +-- FLTDATA Flight data location
| | |-- T0
| | |-- Ti
| | +-- T9
| |
| |-- LOGO Pre-defined logo in AGS report
| |-- OBPM Executable files for the analysis
| |-- RDB Relational database files
| |-- SET Pre-defined configuration (report, parameter set, ..)
| +-- WORK Working space
+-- B3D
|-- 3D
| |-- Aircrafts Aircraft models
| |-- Airports Runways, taxiways marking
| |-- BMNG Blue Marble images
| |-- Landsat LandSat images
| +-- SRTM Terrain elevation
+-- Airports
| |-- Charts Chart used for each airport
| |-- Customs Customer points
| |-- Navaids Waypoints
| +-- Taxiways Taxiway data
|-- Charts Chart and their geo-ref data
|-- Cockpit Cockpit models
+-- Xairports Xplane airport database

4.5.2. Windows update registry


The AGS Setup program has updated the Windows base registry. That concerns the AGS application,
drivers, runtimes and ODBC data sources.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 47/57


5. STARTING AGS

5.1. STARTING MONO USER AGS


To run the Mono User AGS, just double-click on the "AGS Mono" icon in the Windows desktop.
When the connection window appears on the screen, at the first start, the default user is STATION
without password. Press enter to run the AGS.

5.2. STARTING MULTI USER AGS


On each workstation, if you want to run the Multi User AGS, just double-click on the
"AGS <Database Name>" icon in the Windows desktop.
When the connection window appears on the screen, at the first start, the default user is STATION
without password. Press enter to run the AGS.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 48/57


6. INSTALLING THE AGS AIRPORT DATABASE

An airport database is available with the AGS. To import it in the AGS database (only one time, from any
workstation in multi-AGS configuration), proceed as follow:
 In the "Fleet" menu, select the "Airport List" item and click the "Import" button
 In the "File name" field, let the default proposed value ("<Database Name>\SET\AIRPORT.CRP")
and click on the "Start" button
 After few minutes, a new window displays the result of the operation.

Note: For complementary information, please refers to the AGS User Manual, chapter 2.4 "Integration of
an airport database".

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 49/57


7. INSTALLING THE DATABASE VERSIONS

If your AGS package contains some database versions (on floppy disk support), you must import them
into the AGS database (only from the first workstation in multi-AGS configuration). For each database
version, proceed as follow:
 In the AGS, "Programming" menu, select the "Database Version" item and click the "Import"
button
 In the "File name" field, enter A:\DATAVER.VEC and click on the search button.
 In the target "Version No" appears the SAGEM version number. We advice you to keep this
number. Press enter to start the import operation. A window appears to confirm the operation,
press enter. After few seconds, a new window displays the result of the operation. The database
version has been imported.
 Finally, the database version must be validated to be used for analysis purpose:
Select the imported database version and click on the "Validate" button. Then press enter to
validate the version

Remark about import of SAGEM database version: Procedure must be imported towards versions with
decoding frame
AGS Database Version
Decoding Frame

10320 10306 A320 SFIM ED43A1D3/D4 FDIU, v2, ED55

10320 A320 SFI M ED4 5 DM U , Standard DAR Fram e

Flight Operation

10370 Maintenance

10380

Import_procedure.dsf

Note2: For complementary information, please refer to the AGS User Manual, chapter 5 "Database
version Programming".

Important note about trend monitoring


After the import of procedures for maintenance (point  above), it is necessary to enter
in AGS and, in the procedure list:
- activate the procedures (between 8000 and 9000) for the output of the trend
monitoring that you want to use,
- configure the path of the generated file. This path is defined inside the procedure text.
It must be in accordance with the path installed with the trend monitoring software.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 50/57

8. USING THE TRAINING DATABASE

When the AGS is installed, another icon called 'AGS Training xxxx' is also installed in a local drive. This
AGS configuration allows the user to familiarize with the AGS without danger of modifying real
programming.
In addition to the initial database which already contains a programming configuration (A320 database
version), the training database contains media, flights, events and snapshot parameters for statistic
purpose.
To see the AGS training description, please refer to Appendix I of the User Manual.

Note:1 The database used for the training has not been built from real flights but only created from
laboratory data, with the only purpose to be able to display consistent numerical data and
aesthetical graphics.
Note 2: In case of AGS upgrade, the AGS training database will be also updated

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 51/57

9. PRE-DEFINED CONFIGURATION

The AGS system is delivered 'Ready to work', that is to say, the initial database contains a configuration
which allows the user to work immediately with the AGS. This configuration includes:
 A user 'STATION' without password, with all access rights,
 A default aircraft called 'F-AAAA',
 A default database version no 10385 for A320,
 A corresponding A320 flight data file for test FT.AGS in the '<Database Name>\FLTREC\A320\10385'
directory,
 Several screen template for manual analysis,
 Some pre-defined reports including statistics reports (in the Corporate documents section).
 A default 'SAGEM' logo.
Moreover, a file export of the parameter set and the pre-defined reports is available in the '<Database
Name>\SET' directory of the database disk.

HOW TO CHANGE THE LOGO IN THE AGS REPORT


To change the logo in the AGS report, you must copy your logo to replace the default logo file ‘<Database
Name>\LOGO\LOGODEF.BMP' in the database disk.

Note: This bitmap file (65536 colors) will be displayed and resized with the size proportional to 160 * 32
pixels.
If the customer logo has not the proportion width / height near 5 (case of a square logo for
example), it should be re-designed filled with blank at the right part to reach this proportion.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 52/57

10. INSTALLATION OF SEVERAL DATABASES ON SERVER

10.1. PURPOSE
Two reasons can justify creation of several databases :
- To separate physically fleets by airline, aircraft type or A/C Tail list.
- To have an historical database.
For the installation of several databases, please refer to the previous chapter “Multi-User AGS
configuration”.

10.1.1. Separate fleet


The purpose of creating several database is to separate physically the fleet by airline, by type (B737,
A320, etc…) or by A/C Tail list (for important companies). In this case, each database will be managed
by its own staff.

10.1.1.1. Separate fleet by aircraft type


The following example shows case of a big airline with fleet mainly composed by A320 and B737
which want to physically separate its database in three parts. Three databases allow managing this
airline.
On server, following databases are installed:
1. A database dedicated to fleet of A320
2. A database dedicated to fleet of B737
3. A database for others aircraft

SERVER

AGS AGS2 AGS3


Other type A320 B737

WORKSTATIONS

MANAGEMENT OF MANAGEMENT OF MANAGEMENT


MANAGEMENT OF
OTHER A320 OF
B737
AIRCRAFTS B737

separate1.dsf

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 53/57

10.1.1.2. Separate fleet by A/C Tail list


The following example shows a case where aircrafts are managed by list.

SERVER

AGS AGS2 AGS3 AGS


List 1 List 3 List 4
List 2

WORKSTATIONS

MANAGEMENT MANAGEMENT MANAGEMENT MANAGEMENT


OF LIST 1 : OF LIST 2 : OF LIST 3 : OF LIST 4 :
F_AAAA F_BBBA F_CCCA F_DDDA
F_AAAB F_BBBB F_CCCB F_DDDB
F_AAAC F_BBBC F_CCCC F_DDDC
etc... etc... etc... etc...

separate2.dsf

10.1.1.3. Separate fleet by airline


The following example shows a case where several airlines are managed. In this case, each airline is
managed by a dedicated database
1. A database dedicated to the first airline
2. A database dedicated to the second airline

SERVER

AGS AGS2
AIRLINE 1 AIRLINE 2

WORKSTATIONS

MANAGEMENT OF MANAGEMENT
MANAGEMENT OF
AIRLINE 1 OF 2
AIRLINE
B737

separate3.dsf

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 54/57

10.1.2. Historical database


The purpose of creating an additional database is to have an historical database, containing the flight
data from the 5 last years for example. So you can process statistics on a longer period without slow
down the analysis process of new flights on the multi database. So the server will manage two
different databases:
 A main database for daily task with 18 months of data,
 An historical database to keep trace of flight result and process investigation on a long period (5 years).
Main Server
Flight Data Backup media
Input
Daily backup
Main database
18 month / 1 Gbytes

Automatic copy of
flight information
every month

Historic Database
Backup after update
5 years / 3.5 Gbytes

Statistic at long term

Daily report

Statistic report

In order to improve statistic performance on biggest historical databases, the process can be moved
on local AGS workstation, by creating a temporary database.
Main Server
Flight Data
Input

Main database
18 month / 1 Gbytes

Local AGS Workstation


Filter (pre-selection)
Example:
Last 12 months of flight
Historic Database Approach to CDG, LHR, JFK
Temporary database
5 years / 3.5 Gbytes
35 Mbytes

Query
Example:
Not stabalized approach per aircraft type on runway
26L CDG, 09L LHR and 22L JFK.

Statistic report

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 55/57

10.2. DATABASE MANAGEMENT

10.2.1. Purpose
Each database must have the "AGS database management" module on server or on a workstation.
Several databases can be managed by the server or a particular workstation:

SERVER

AGS AGS2 AGSn

WORKSTATIONS

MANAGEMENT
OF
AGS Automatic process for AGS and AGS2 AGS Automatic processB737
for AGSn
AGS Database Management for AGS and AGS2 AGS Database Management for AGSn

separate4.dsf

10.2.2. Advice for the management for several Database


Some precautions must be taken, principally for flight de-identification, because management of each
database is separated: be careful to program the flight de-identification configuration for all databases
in the same way.

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 56/57

10.3. HISTORICAL DATABASE MANAGEMENT

10.3.1. Historical database creation


If AGS Database is already installed on a server, you can add a new database to work with (see
chapter 4.3.2.3). If it is not the case, you must install first AGS Database (see chapter 4.3.2.1).

10.3.2. Access to historical database on a workstation


Once the new database is created, you have to connect it to a workstation. If you want to use a station
only for this job, then install AGS Workstation on a computer (see chapter 4.3.3). If you want to use a
workstation that already exists, then change its configuration (see chapter 4.3.3.2.2).

10.3.3. Historical database update


To update the historical database from the central database; please use the "Database management"
module, function "Transfer/Copy Flights To Another Database":

10.3.4. Historical database backup


The historical database must have a "Database management" module on a specific workstation, to
enable the database backup

© Propriété de Sagem Défense Sécurité - Reproduction et Divulgation interdites / Disclosure and copy prohibited.

24039597-D
Analysis Ground Station V14 SR3
Installation Manual

3300444038-02 – Page 57/57