OEM Relative and differential

pressure switch type 605

Pressure range
20 ... 400 Pa

Type 605 pressure switches are specially developed for use in gas Fitting of the switch Fast mounting with snap
fired heating systems. There are more than 40 million switches in bracket system
use worldwide. Produced on a fully automated production line.
Adjusting security
High setting accuracy and repeatability, combined with excellent
reliability characterise a quality of switch above the industry norm. High contact strength (typically 10 cN)
Essentially less susceptibility to polution of
contact
Roll operation of contact surface
Less sensitive to contact polution through
self cleaning effect
Diaphragm design / material
Better long term stability achieved though the
use of a 2 component silicon diaphragm.
Unique trapezoid diaphragm design provides
for a better contact release and therefore a
more accurate switching point

Huba Control type 605 - Technical data subject to change - Edition 10/2015a 1/5
Technical overview
Pressure range
Relative and differential 20 ... 400 Pa 1)

Operating conditions
Medium Air and neutral gases
Medium / ambient -30 ... +110 ÀC
Temperature 2)
Storage -30 ... +110 ÀC
< +85 ÀC 5000 Pa
Tolerable overload on one side
+85 ... +110 ÀC 1500 Pa
Smallest turn on pressure of 20 Pa 3) Smallest switching differential 8 Pa

Materials in contact with the medium


Sensor Silicone LSR
Case PC Lexan 500R 4)

Electrical overview
Switching load See Nominal loading limits
Contact system Changeover switch
Service life Mechanically > 106 switching cycles

Protection standard
Not mounted IP 00
With contact safety guard IP 30
With cover, without seal IP 54
With cover and seal IP 65

Reproducibility
Between μ 1 Pa

Electrical connection
6.3 mm
AMP connector 5)
4.8 mm

Pressure connections
Pipe ± 6.2 mm
Orifice installed for damping pulsating pressure at P1, P2 (option)

Mounting instructions
Installation arrangement Please indicate installation arrangement
With several brackets
Mounting
Fastening clip for quick mounting

Tests / Admissions
UL MFHX2/8 or XAAK2/8
DVGW acc. to DIN EN 1854
EC type examination certificate CE-0085AP0974
Electromagnetic compatibility CE conformity acc. to EN 61326-2-3
Low voltage directive 2006/95/EC
Gas appliance directive 2009/142/EC

Weight
Without accessories ~ 60 g

Packaging
300 pieces
Multiple packaging in cardboard
1200 pieces

Adjustable switching differences


Switching difference adjustment only inside
20 - 220 Pa 220 - 400 Pa
shaded area:

Example: Upper switching point 220 pascal.


Switching difference between 14 and 36 pascal.
Switching point above (Pa)

Switching point above (Pa)

Example: Upper switching point 40 pascal.


Switching difference between 9 and 30 pascal.

Example: Upper switching point 20 pascal,


smallest switching difference 8 pascal.

Swtching difference (Pa) Switching difference (Pa)

1)
Higher pressures on request 2)
Higher temperatures on request 3)
Switching differential is factory-set
4)
Fiberglass reinforced plastic 10% GF 5)
According to DIN 46244

2/5 Huba Control type 605 - Technical data subject to change - Edition 10/2015a
Dimensions in mm / Electrical connections

1 Feeder (COM)
2 NC contact
3 NO contact

Cover with / without sealing


and PT screw

Contact safety guard with PT srew


Cable exit AMP1 or AMP2

Tolerance of switching point The principle of high contact pressure

Simplified representation of the new DPS 605 contact system. The high contact
pressure results form the optimized length ratios of LC and LD.

Contact pressure (CP)


Diaphragm pressure (DP)
CP = DP ( )
LC
LD

Pivot point

Switching point
upwards LC
LD
LC = Length of contact lever
LM = Length of diaphragm lever

Huba Control type 605 - Technical data subject to change - Edition 10/2015a 3/5
Accessories supplied loose

Order number
Cover with seal and PT screw 100306
Cover without seal and PT screw 100307
Cover with PT screw and cable output AMP-1 100297 + 102981 (PT screw)
Cover with PT screw and cable output AMP-2 100298 + 102981 (PT screw)
Thickness of sheet metal 0.8 ... 1.1 mm 100294
Fastening clip
Thickness of sheet metal 1.8 ... 2.1 mm 100293
Fastening clip (with mounting holes) 106790
Bracket type A 100295
Bracket type B 100296
Mounting plate 106707
Mounting adaptor small 111223
Mounting adaptor large 112985
Calibration certificate 104551

Fastening clip Fastening clip Bracket type A Bracket type B


(Dimensions in mounted state) (with mounting holes)

Mounting plate Mounting adaptor small Mounting adaptor large

For screw PT40 For screw PT40

Thickness of sheet metal


0.8mm

Nominal loading limits


for AC for DC

1 = ohmic 1 = ohmic
2 = inductive (cosφ 0.7) 2 = inductive
Can also be operated with TTL-load

U (V) U (V)

4/5 Huba Control type 605 - Technical data subject to change - Edition 10/2015a
Huba Control AG
Headquarters
Industriestrasse 17
5436 Würenlos
Telefon +41 (0) 56 436 82 00
Telefax +41 (0) 56 436 82 82
[email protected]

Huba Control AG
Niederlassung Deutschland
Schlattgrabenstrasse 24
72141 Walddorfhäslach
Telefon +49 (0) 7127 23 93 00
Telefax +49 (0) 7127 23 93 20
[email protected]

Huba Control SA
Succursale France
Rue Lavoisier
Technopôle Forbach-Sud
57602 Forbach Cedex
Téléphone +33 (0) 387 847 300
Télécopieur +33 (0) 387 847 301
[email protected]

Huba Control AG
Vestiging Nederland
Hamseweg 20A
3828 AD Hoogland
Telefoon +31 (0) 33 433 03 66
Telefax +31 (0) 33 433 03 77
[email protected]

Huba Control AG
Branch Office United Kingdom
Unit 13 Berkshire House
County Park Business Centre
Shrivenham Road
Swindon Wiltshire SN1 2NR
Phone +44 (0) 1993 776667
Fax +44 (0) 1993 776671
[email protected]

www.hubacontrol.com

5/5 Huba Control type 605 - Technical data subject to change - Edition 10/2015a