HSTP3T60KE/HSTP3T80KE
HSTP3T90KE/HSTP3T100KE/HSTP3T120KE
Online (Double
Three-phase Conversion) UPS UPS Parallel
ECO Mode LCD Touch Panel Dual Inputs
Design Topology Expansion
The 3-Phase UPS with parallel expansion capability to achieve N+X power redundancy for
enterprise applications
Designed for server room and data center applications, the HSTP3T (3-Phase) Series adopts double-conversion topology
to provide seamless Pure Sine Wave output. The products also adopt ECO Mode to save on energy costs, Smart Battery
Management (SBM) to extend battery lifespan, and multifunction LCD readout to display precise information. The power
management software allows users to easily control and monitor the UPS system.
SERIES FEATURES
• Three-phase Design • Generator Compatible
• Online (Double Conversion) UPS Topology • Pure Sine Wave Output
• Hot-swappable Power Modules • Overload Protection
• ECO Mode • Maintenance Bypass Switch
• Color LCD Panel • LCD Status Display
• LCD Touch Panel • Emergency Power Off (EPO) Port
• UPS Parallel Expansion • SNMP/HTTP Remote Management Capability (Optional)
• Dual Inputs • PowerPanel Management Software
PRODUCT CALLOUTS
1 . LCD Control Panel
2 . Maintenance Bypass Circuit Breaker 1
3 . Main Input Circuit Breaker 12
1 1 . Bypass Fan 3
2
1 2 . Power Module 4 5
11
11
HSTP3T60KE HSTP3T80/90/100/120KE
Copyright © 2024 Cyber Power Systems, Inc. All rights reserved. www.cyberpower.com
HSTP3T60KE/HSTP3T80KE/HSTP3T90KE
HSTP3T100KE/HSTP3T120KE
TECHNICAL SPECIFICATIONS
Model Name HSTP3T60KE HSTP3T80KE HSTP3T90KE HSTP3T100KE HSTP3T120KE
General
Phase Three Phase
Form Factor Tower
Energy Saving Technology Online ECO Mode Efficiency up to 98%
Normal Mode Efficiency (%) 95% 96% 95% 96% 95%
Battery Mode Efficiency (%) 95% 96% 95% 96% 95%
Parallel Expansion (Max. Units) 4
Input
Dual Power Inputs Yes
Nominal Input Voltage (Vac) Line to Neutral (L-N): 220, 230, 240 Vac, Line to Line (L-L): 380, 400, 415 Vac
Input Voltage Range (Vac) Line to Neutral (L-N): 132 ~ 276 Vac, Line to Line (L-L): 228 ~ 478 Vac
Input Frequency (Hz) 50 ± 3, 60 ± 3
Input Frequency Range (Hz) 40 ~ 70
Input Power Factor 0.99
Output
Capacity (VA) 60000 80000 90000 100000 120000
Capacity (Watts) 54000 72000 81000 90000 108000
Rated Output Voltage (Vac) Line to Neutral (L-N):220, 230, 240 Vac, Line to Line (L-L):380, 400, 415 Vac
Output Voltage Tolerance (%) 1.5%
Output Frequency (Hz ± %) 50 ± 0.1, 60 ± 0.1
Power Factor 0.9
Overload Protection (Line Mode) 105~110% Load for 60 min, 110~125% Load for 10 min, 125~150% Load for 1 min, >150% Load Immediately
Crest Factor 3:1
Harmonic Distortion (Linear Load) THD1%
Harmonic Distortion (Non-linear Load) THD5.5%
Battery
Compatible Battery Types VRLA, AGM, Gel, Wet
Recharge Power (%) Default 10% (Selectable from 1~20% x UPS Capacity)
Charger Voltage Tolerance (%) ≤1%
Battery Solution Extended Battery
Battery Voltage (V) ±240 (480)
Compatible Extended
SMBF17, SMBF20, SMBF26, SMBF40, SMBF65, BCA100N125, BCA12N63, BCA20N125, BCA40N125
Battery Cabinet (EBC)
Operating Elevation
≤1000, Load Derated 1% per 100m from 1000m and 2000m
(feet/meters)
Certifications
Certifications* CE, IEC62040-1, IEC62040-2
*Certifications may vary according to different regions. Visit www.cyberpower.com for more information.
#All specifications are subject to change without notice.
CyberPower and the CyberPower logo are trademarks of Cyber Power Systems, Inc., and/or affiliates, which are
registered in many countries and regions. All other trademarks are the property of their respective owners.
Copyright © 2024 Cyber Power Systems, Inc. All rights reserved. www.cyberpower.com