0% found this document useful (0 votes)
72 views13 pages

Sparkmax Wash4C

Uploaded by

Alexandre Gomes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
72 views13 pages

Sparkmax Wash4C

Uploaded by

Alexandre Gomes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 13

USER MANUAL

1
INTRODUCTION
Thank you for having chosen our LED lighting
Unpack the device, inside the box you should find:
The fixture device
One power cable
One XLR connection cable
This manual
Please check carefully that there is no damage caused by
transportation. Should there be any problems, consult your dealer and
don’t install this device.

DESCRIPTION
Features
 Easy multi fixture hanging system, outdoor version available
 48pcs RGBW 4in1 LED, no ultraviolet radiation
 More than 20,000 hours for the LED light source
 15,000 lm
 35 degrees
 1/2/3/4/6/8F/9F/10F/10D/14/15 DMX channels
 16 Bit Dimmer
 DMX Mode /Master-slave mode
 AC 100-240V 50/60Hz 500W
 Diecasting heatsink with fans control, convection cooling with
temperature sensor to extend the lamp life
 7000 Hz LED scan rate
 L: 490mm H: 313mm W: 144mm
⚫ IP65

SAFETY INSTRUCTIONS
This device has left the factory in perfect condition. In order to
maintain this condition and to ensure a safe operation, it
is absolutely necessary for the user to follow the safety
instructions and warning notes written in this user manual.
This device falls under protection-class I. Therefore it is essential that
the device should be earthed.
The electric connection must carry out by qualified person.
If the external flexible cable or cord of this luminaire is damaged,
2
it shall be exclusively replaced by the manufacturer or his
service agent or a similar qualified person in order to avoid a hazard.
Make sure that the available voltage is not higher than stated at the
end of this manual.
Make sure the power cord is never crimped or damaged by sharp
edges.
If this would be the case, replacement of the cable must be done by
an authorized dealer.
Always disconnect from the mains, when the device is not in use or
before cleaning it. Only handle the power cord by the plug. Never
pull out the plug by tugging the power cord.

Never look directly into the light source, as


sensitive persons may suffer an epileptic shock.

Important:
Damages caused by the disregard of this user manual are not
subject to warranty. The dealer will not accept liability for any
resulting defects or problems.

DMX-512 control connection


The product has a DMX 512 input fitted with 3-pin XLR connectors.
Screened cables in compliance with EIA RS-485 specifications and the
following characteristics must be used for connections:
- 2 conductors plus screen
- 120Ohm impedance
- low capacitance
- max. transmission rate 250kBaud.

DMX-512 connection with DMX terminator


For installations where the DMX cable has to run a long distance or is
in an electrically noisy environment, such as in a discotheque, it is
recommended to use a DMX terminator. This helps in preventing
corruption of the digital control signal by electrical noise. The DMX
terminator is simply an XLR plug with a 120 OHM resistor connected

3
between pins 2 and 3,which is then plugged into the output XLR
socket of the last fixture in the chain.

Display Menu
Main menu Sub-menu
Address DMX Address Setting
Channel 1Ch

Channel 2Ch

Channel 3Ch

Channel 4Ch

Channel 6Ch

Channel Mode Channel 8ChF

Channel 9ChF

Channel 10ChF

Channel 10ChD

Config. Channel 14Ch

Channel 15Ch

Set Curve Mode L

Set Curve Mode Q


Dimmer Curve
Set Curve Mode I

Set Curve Mode S


Cipher Setup 0-999
Celsius Degree
Temp Unit CS
Fahrenheit Degree
Value Clear
DMX Status
Value Hold
4
Fan Speed Normal/ middle/ fast
WDMX Mode -
Disable
Display Mode
Enable
Temperature
System Info
Fixture Time
Red 0-255
Green 0-255
Color Menu
Blue 0-255
White 0-255
Set Red 0-255
White Balance Set Green 0-255
Set Blue 0-255
Static color Color 0-51 -
Effect Auto 01 -

Effect Auto 02 -
Auto Test
Effect Auto 03 -
Effect Auto 04 -
Fan Test Fan 1 On/ Off
Auto speed 00 - 40
Yes
Load Default
No
Firmware Strobe Wash
Version Version 6.00

Main functions
1. Address: Current DMX address
A. Setting DMX address by button
press ENTER button when show the address menu, then adjust

5
the DMX address by pressing [UP] or [DOWN] button
Press [ENTER] to confirm or press [ESC] to return to main menu.
B. Setting DMX address by controller
1.Set the DMX value of channel 5 to 10-15,channel 17 to 20-26,
channel 7 to 30-36,channel 8 to 40-46,then the devices
connected to the controller will enter to the setting address mode
2. Set the DMX value of channel 1 from 0-59,then you will see
the first number of the Address change to (channel 1 value)/10.
For example, when set the value of channel 1 to 20,the first DMX
address number will be 2(20/10=2),
3. Set the DMX value of channel 2 from 0-99,then you will see
the second number of the Address change to (channel 2
value)/10.
For example, when set the value of channel 2 to 30,the first DMX
address number will be 2(30/10=3),
4.Set the DMX value of channel 3 from 0-99,then you will see the
third number of the Address change to (channel 3 value)/10.
For example, when set the value of channel 1 to 40,the first DMX
address number will be 3(40/10=4),
And the DMX address you set by controller will be 234.
5. Set the DMX value of channel 4 to 255,then you will save the
DMX address settled by the controller.
Caution: It won’t save the address if the address number is
over 512
6. set the value of channel 5-8 out of the value range show on the
step 1,and the device will exit the setting address mode

2. Config.
Setting DMX mode
press ENTER button when show the channel menu, then select
the DMX mode by pressing [UP] or [DOWN] button

Setting Dimmer Curve


press ENTER button when show the dimmer curve menu, then
select the dimmer curve by pressing [UP] or [DOWN] button
Setting Cipher
press ENTER button when show the cipher setup menu, then
setup cipher by pressing [UP] or [DOWN] button

6
Key mode
press ENTER button when show the key mode menu, then
select lock or unlock by pressing [UP] or [DOWN] button
Show Temperature
press ENTER button when show the Temp Unit CS menu, select
the way of showing the fixture’s temperature in ℃ or ℉ by
pressing [UP] or [DOWN] button
DMX status
press ENTER button when show the DMX Status menu, then
select clear value or hold value by pressing [UP] or [DOWN]
button
Display mode
press ENTER button when show the Display Mode menu, then
select auto or on by pressing [UP] or [DOWN] button

3. System info
Temperature
press ENTER button when show the Temperature menu, then it
will show the temperature of the fixture
Fixture time
press ENTER button when show the Fixture time menu, then it
will show how long time of the fixture already used

4. Color menu
press ENTER button when show the Color menu, press Enter
button to select the color mode, then adjust the color by pressing
[UP] or [DOWN] button
5. White balance
press ENTER button when show the white balance menu, press
Enter button to select the color mode, then adjust the color by
pressing [UP] or [DOWN] button

6. Auto test
press ENTER button when show the auto test menu, select test
mode by pressing [UP] or [DOWN] button

7
DMX functions and values
1 ch Mode
Ch Value Function
1 0-255 Static Color

2 ch Mode
Ch Value Function
0-7 Blackout
8-15 Shutter Open
16-151 Strobe
1 152-175 Fade In
175-199 Fade Out
200-244 Random Strobe
245-255 Shutter Open
2 0-255 Master Dimmer

3 ch Mode
Ch Value Function
1 0-255 Red
2 0-255 Green
3 0-255 Blue

4 ch Mode
Ch Value Function
1 0-255 Red
2 0-255 Green
3 0-255 Blue
4 0-255 White

6 ch Mode
Ch Value Function

8
0-7 Blackout
8-15 Shutter Open
16-151 Strobe
1 152-175 Fade In
175-199 Fade Out
200-244 Random Strobe
245-255 Shutter Open
2 0-255 Master dim
3 0-255 Red
4 0-255 Green
5 0-255 Blue
6 0-255 White

8 ch Mode
Ch Value Function
1 0-255 Red
2 0-255 Fine Red
3 0-255 Green
4 0-255 Fine Green
5 0-255 Blue
6 0-255 Fine Blue
7 0-255 White
8 0-255 Fine White

9 ch Mode
Ch Value Function
1 0-255 Master Dimmer
2 0-255 Red
3 0-255 Fine Red
4 0-255 Green
5 0-255 Fine Green
6 0-255 Blue

9
7 0-255 Fine Blue
8 0-255 White
9 0-255 Fine White

10 chF Mode
Ch Value Function
1 0-255 Master Dimmer
2 0-255 Fine Master Dimmer
3 0-255 Red
4 0-255 Red dimmer fine
5 0-255 Green
6 0-255 Green dimmer fine
7 0-255 Blue
8 0-255 Blue dimmer fine
9 0-255 White
10 0-255 White dimmer fine

10 chD Mode
Ch Value Function
0-7 Blackout
8-15 Shutter Open
16-151 Strobe
1 152-175 Fade In
175-199 Fade Out
200-244 Random Strobe
245-255 Shutter Open
2 0-255 Master dim
3 0-255 Red1
4 0-255 Green1
5 0-255 Blue1
6 0-255 White1
7 0-255 Red2
8 0-255 Green2

10
9 0-255 Blue2
10 0-255 White2

14 Ch Mode
Ch Value Function
1 0-255 Master Dimmer
2 0-255 Red1
3 0-255 Green1
4 0-255 Blue1
5 0-255 White1
6 0-255 Red2
7 0-255 Green2
8 0-255 Blue2
9 0-255 White2
0-15 Shutter Open
10
16-255 Strobe (fast to slow)

11 0-255 Color macro, color+black

0-35 Shutter Open


36-71 Fade Out
72-107 Fade In
12 108-143 Fade In and Out
144-179 Color mix
180-215 Four Color Flow
216-255 Eight Leds Flow
13 0-255 Dimmer Speed
0-63 Linear
64-127 Square
14
128-191 Invert Square
192-255 S-Curve

11
15 Ch Mode
Ch Value Function
1 0-255 Master dim
2 0-255 Master Dimmer fine
3 0-255 Red
4 0-255 Red dimmer fine
5 0-255 Green
6 0-255 green dimmer fine
7 0-255 Blue
8 0-255 blue dimmer fine
9 0-255 White
10 0-255 white dimmer fine
0-15 No strobe
11
16-255 Strobe (fast to slow)
12 0-255 Color Macro color+black
0-35 Shutter Open
36-71 Fade Out
72-107 Fade In
13 108-143 Fade In and Out
144-179 Fade By SIN Curve
180-215 Four Color Flow
216-255 Eight Leds Flow
14 0-255 Dimmer speed
0-63 Linear
64-127 Square
15
128-191 Invert square
192-255 S-curve

12
CLEANING AND MAINTENANCE
We recommend a frequent cleaning of the device. Please use a soft
lint-free and moistened cloth. Never use alcohol or solvents!
CAUTION!
Disconnect from mains before starting maintenance
operation.
There are no serviceable parts inside the device. Maintenance and
service operations are only to be carried out by authorized dealers.
If you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to
be replaced by authorized dealers only in order to avoid hazards.
If you have further questions, please contact your dealer.

INSTALLATION
The device must only be installed at a vibration-free, oscillation-free
and fire-resistant location.

13