DATA SHEET

Monitored eConnect® PDUs

Monitored eConnect® PDUs provide


remote power monitoring to the input
and branch circuit level, making it
possible to obtain and manage power
consumption at the cabinet level.

KEY FEATURES

Reduced Networking Costs and Complexity–


Secure Array® allows the use of a single
IP address for up to 48 connected PDUs
(32 when electronic locks are integrated).
Second IP address for the entire array
provides failover capability.

Resistance to High Temperature – Market-


leading temperature ratings of up to 149°F Vertical and Horizontal
(65°C) ensures reliability when mounted Options Available
toward hot aisles.

Simplified Load Balancing – Phase-balance


outlets on three-phase models ensure equal
loading across all phases; allows use of shorter Additional Features:
equipment power cords for better cable and
airflow management. • Input and branch circuit monitoring with billing-grade +/-1% accuracy

No Accidental Disconnections – Patented, • Field-replaceable controller module for easy serviceability and upgradeability while
low-profile locking outlets prevent accidental maintaining power to critical loads; SD-card transfers PDU configuration
disconnections without requiring special cords
• Onboard GUI, RESTful API, SNMP v1/v2/v3, Command Line Interface (CLI), and
Easy Identification of Failover Unit – native Power IQ® DCIM software integration allows users to easily manage PDUs
Redundancy Pack includes 2 PDUs (one in Black
and one in Glacier White) for easy identification • Zero Touch Provisioning (ZTP) automates configuration and provisioning of large
of the primary and secondary unit. deployments of PDUs

Electronic Lock Integration – Patented


• HTTPs support, 802.1x support, RADIUS and LDAP integration for enhanced authentication
technology seamlessly integrates PDU,
and security
environmental sensors and electronic locks into
a single hardware and software solution
• Customization capabilities: outlet configurations, color options, power cord length,
Gigabit Ethernet – Ensures compatibility with input connection types and more
enterprise routers and switches.
• Made in the United States, TAA-compliant
Latest UL Compliance – Meets UL and IEC 62368
for compliance with new listing requirements for
North America and the European Union.

Cabinet Preinstallation – Complete ecosystem


ships ready for IT equipment integration, and
saves deployment time and reduces packaging
waste.

High Power configurations – Configurations


supporting up to 100A Input provide an
optimized solution for GPU & AI based
applications. 30A branch circuit breakers
provide flexibility when plugging high power
IT equipment.

Availability: US, Canada, Latin America, Europe, Middle East & Africa

United States & Canada Latin America Europe Middle East & Africa Asia Pacific
Simi Valley, CA Mexico City, Mexico Buckinghamshire Dubai, UAE Jing'an District,
800-834-4969 +52-55-5203-7525 England, UK +971-4-2602125 Shanghai, China
Toronto, Ontario, Canada Toll Free within Mexico +44-1628-524-834 Doha, Qatar +86 21 6880-0266
+905-850-7770 800-201-7592 +974-4-267422 chatsworth.com.cn
chatsworth.com chatsworth.com.co
[email protected]
Monitored eConnect® PDUs
SPECIFICATIONS

Description: Single-input, vertical and horizontal rack-mount PDUs


Use: For indoor use in environmentally controlled areas or within environmental enclosures that maintain Operating Conditions (listed below)
• Alternating current, 50/60 Hz, 10 ft (3 m) input cord or Terminal Block available as standard; custom lengths between 3 - 15 ft. available
Power Input:
• Voltage, maximum current, and inlet/plug type varies per model (see ordering table)
Power Capacity: Specific to PDU, limited by circuit breakers or power input (see ordering table)
Power Output: NEMA 5-20R, Locking IEC C13 and/or IEC C19 Outlets, specific to PDU with up to 48 outlets (see order table)
• UL 489 listed, single- or two-pole, hydraulic-magnetic breakers available on single- and three-phase models with 30A and above input
Circuit Protection: • Low-profile design prevents accidental disconnection
• 30A breakers for 208V, 100A; 415V, 60A and 415V, 100A configurations
• Input line currents
Metering: • Voltage, current, power, energy and power factor at branch circuits
• +/- 1% billing-grade
• Liquid Crystal Display (LCD) with power-on autotext orientation, color
• Provides PDU information; allows initial IP setup, restore defaults and upgrade firmware
Local Display:
• Displays voltage, current, power for input lines and breakers
(Vertical PDUs only)
• Displays temperature and humidity when optional environmental sensor (P/N 14665-001) is attached to the PDU
• Displays alarm notifications – separate LED flashes red on alarm
• 10/100/1000MB Ethernet Port
• Secure Array IP Consolidation for up to 48 PDUs with no integrated electronic locks or 32 PDUs with integrated electronic locks
Networking:
• Secure Array IP Consolidation supports alternate/failover network connection through a second PDU
• Static IP and Dynamic Host Configuration Protocol (DHCP) Support, Zero Touch Provisioning (ZTP)
HTTP/HTTPs compatible onboard Web GUI, SNMP v1/v2/v3; RESTful API, CLI
Native Software Integration:
Remote - Sunbird Power IQ® DCIM and dcTrack DCIM
Management: - ZPE Systems Nodegrid Manager™
- RF Code Centerscape Software
- Nlyte DCIM
Console Access: Through serial console port connection and Command Line Interface (CLI)
• LDAP and Radius Authentication
• Password protection
• Separate user- and admin-level permissions
Security:
• Ability to upload custom HTTPs certificate
• Secure Shell (SSH)
• 802.1x Support
Controller: Field-replaceable controller module; SD-card transfers PDU configuration
Firmware: Flash upgradeable through USB port, Web interface, CLI, API or Power IQ.
Environmental
• Supports two Temperature & Humidity sensors
Sensor
• USB Type A ports
Integration:
Electronic Lock • Front and rear cabinet door locks (ordered separately) connected to AUX ports on the PDU
ADDITIONAL
Integration: FEATURES:
• Door locks are powered from and remotely accessed through the PDU
Vertical PDUs:
• 2 preinstalled tool-less mounting buttons; adjustable positions
Mounting:
• Top or bottom power cord entry orientation
Horizontal PDUs: Include rack-mount brackets for 19"EIA (482.6 mm) racks
• Bonded power inlet/plug and external bond connection with a threaded M5 attachment point
Grounding/Bonding:
• Includes a bonding kit for CPI cabinets
• Black or Glacier White available as standard options; other colors available as custom solutions
Color Options:
• Redundancy Pack includes (1) Black PDU and (1) Glacier White PDU
• Temperature: 32°F – 149°F (0°C – 65°C) at Input Power Rating (kW)
Operating
• Relative Humidity: 5% – 95%, noncondensing
Conditions:
• Elevation: 0 – 10,000' (0 – 3,000 m)
Storage/ • Temperature: -13°F – 149°F (-25°C – 65°C)
Non-operating • Relative Humidity: 5% – 95%, noncondensing
Conditions: • Elevation: 0 – 50,000’ (0 – 15,000 m)
Vertical PDUs: 27 lb (12 kg) single unit; 54 lb (24 kg) Redundancy Pack
Horizontal PDUs:
Shipping Weight:
• 1U is 18 lb (8.2 kg) single unit; 35 lb (15.9 kg) Redundancy Pack
• 2U is 23 lb (10.4 kg) single unit; 45 lb (20.4 kg) Redundancy Pack
Certifications: NEMKO certified to UL/IEC62368, CE (EU), FCC Part 15, Class A, EN 55022, RoHS Compliant
Warranty: 3 years standard with advanced replacement; 2 additional years optional

2 chatsworth.com
Monitored eConnect® PDUs
VERTICAL CONFIGURATION

Use Vertical eConnect PDUs in data centers and equipment rooms with 42U or higher racks, cabinets and
enclosures to provide power connections alongside equipment for higher-density applications.
Use Redundancy Pack to support redundant power circuits.

Hydraulic-Magnetic Breakers

Color-Coded Labels Printed on Metal

Status LED Light

Locking Outlets
Field-Replaceable Controller Module
for Vertical eConnect PDUs

1
3
2

1 Proprietary Auxiliary Ports for Lock Kits

2 Serial Console Port - USB Mini Type B


8
3 Status LED
Ethernet Port - RJ45
4
Serial Console Port - RJ45
5
USB Type A Ports for Firmware and Temperature/Humidity
6 Sensors
5
4 7 Secure Array Ports - RJ45 - for linking of up to 48 PDUs

6 8 LCD Local Display

7 Field-Replaceable Controller Module

3 chatsworth.com
Monitored eConnect® PDUs
ORDERING INFORMATION

Monitored eConnect PDU, Vertical - North America


Part Number
Input kW Capacity Cabinet
Redundancy Input Plug Outlets
Black Glacier White Amperage (UL) Compatibility
Pack**
120 Volt, Single-Phase Input

EA-3001-C EA-3001-E EA-3001-CE 20A C20 Inlet to L5-20 (24) 5-20 1.9 kW 42U & higher

EA-3002-C EA-3002-E EA-3002-CE 30A L5-30 (24) 5-20 2.9 kW 42U & higher

208 Volt, Single-Phase Input

EA-3003-C EA-3003-E EA-3003-CE 20A C20 Inlet to L6-20 (24) C13 3.3 kW 42U & higher

EA-3004-C EA-3004-E EA-3004-CE 30A L6-30 (24) C13 5 kW 42U & higher

EA-3015-C EA-3015-E EA-3015-CE 30A L6-30 (36) C13 + (6) C19 5 kW 42U & higher

120/208 Volt, Single-Phase Input

EA-3087-C EA-3087-E EA-3087-CE 30A L14-30 (30) C13 + (6) C19 + (6) 5-20 5 kW 42U & higher

120/208 Volt, Three-Phase Input

EA-3013-C EA-3013-E EA-3013-CE 20A L21-20 (30) C13 + (6) C19 + (6) 5-20 5.7 kW 42U & higher

EA-3017-C EA-3017-E EA-3017-CE 20A L21-20 (36) C13 + (6) C19 5.7 kW 42U & higher

EA-3014-C EA-3014-E EA-3014-CE 30A L21-30 (30) C13 + (6) C19 + (6) 5-20 8.6 kW 42U & higher

EA-3018-C EA-3018-E EA-3018-CE 30A L21-30 (36) C13 + (6) C19 8.6 kW 42U & higher

208 Volt, Three-Phase Input

EA-3016-C EA-3016-E EA-3016-CE 30A L15-30 (36) C13 + (6) C19 8.6 kW 42U & higher

EA-3007-C EA-3007-E EA-3007-CE 50A CS8365 (30) C13 + (12) C19 14.4 kW 42U & higher

EA-3019-C EA-3019-E EA-3019-CE 50A CS8365 (36) C13 + (6) C19 14.4 kW 42U & higher

EA-3125-C EA-3125-E EA-3125-CE 50A CS8365 (54) C13 14.4 kW 45U & higher

EA-3126-C EA-3126-E EA-3126-CE 60A IEC 60309 60A 3P+E (54) C13 17.2 kW 45U & higher

EA-3008-C EA-3008-E EA-3008-CE 60A IEC 60309 60A 3P+E (30) C13 + (12) C19 17.2 kW 42U & higher

EA-3020-C EA-3020-E EA-3020-CE 60A IEC 60309 60A 3P+E (36) C13 + (6) C19 17.2 kW 42U & higher

EA-3033-C EA-3033-E EA-3033-CE 60A IEC 60309 60A 3P+E (12) C13 + (18) C19 17.2 kW 42U & higher

EA-3089-C EA-3089-E EA-3089-CE 100A IEC60309 100A 3P+E (30) C13 + (12) C19 28.8kW 42U & higher

EA-3011-C EA-3011-E EA-3011-CE 100A AC Terminal Block 3P4W (30) C13 + (12) C19 28.8kW 42U & higher

240/415 Volt, Three-Phase Input

EA-3021-C EA-3021-E EA-3021-CE 30A L22-30 (36) C13 + (6) C19 17.2 kW 42U & higher

EA-3127-C EA-3127-E EA-3127-CE 30A L22-30 (54) C13 17.2 kW 45U & higher

Monitored eConnect PDU, Vertical - Worldwide


Part Number kW Capacity kW Capacity
Input Cabinet
Redundancy Input Plug Outlets Worldwide North
Black Glacier White Amperage Compatibility
Pack** (CE) America (UL)

220 - 240 Volt, Single-Phase Input

C20 Inlet to IEC 60309 16A


EA-3005-C EA-3005-E EA-3005-CE 16A (24) C13 3.8 kW 3.8 kW 42U & higher
1P+N+E

EA-3006-C EA-3006-E EA-3006-CE 32A IEC 60309 32A 1P+N+E (24) C13 7.7 kW 6.1 kW 42U & higher

EA-3022-C EA-3022-E EA-3022-CE 32A IEC 60309 32A 1P+N+E (36) C13 + (6) C19 7.7 kW 6.1 kW 42U & higher

220 - 240/380-415 Volt, Three-Phase Input

EA-3023-C EA-3023-E EA-3023-CE 16/20A IEC 60309 16/20A 3P+N+E (36) C13 + (6) C19 11.5 kW 11.5 kW 42U & higher

EA-3009-C EA-3009-E EA-3009-CE 32A IEC 60309 32A 3P+N+E (30) C13 + (12) C19 23 kW 18.4 kW 42U & higher

EA-3024-C EA-3024-E EA-3024-CE 32A IEC 60309 32A 3P+N+E (36) C13 + (6) C19 23 kW 18.4 kW 42U & higher

EA-3128-C EA-3128-E EA-3128-CE 32A IEC 60309 20A 3P+N+E (54) C13 23 kW 18.4 kW 45U & higher

EA-3010-C EA-3010-E EA-3010-CE 60A IEC60309 60A 3P+N+E (30) C13 + (12) C19 34.5kW 34.5kW 42U & higher

EA-3193-C EA-3193-E EA-3193-CE 100A IEC 60309 100A 3P+N+E (8) C13 + (24) C19 57.5kW 57.5kW 45U & higher

Notes: **Redundancy Pack includes 2 PDUs in Black and Glacier White for easy identification of the primary and secondary unit.

4 chatsworth.com
Monitored eConnect® PDUs
HORIZONTAL CONFIGURATIONS

Use Horizontal eConnect PDUs in applications that require outlets at the top or bottom of cabinets for quick access, low- to medium-density
applications that require fewer connections and in distributed infrastructure for edge applications. Horizontal PDUs are available in 1U and
2U heights with up to 24 outlets.

Monitored eConnect PDU, 1U


Front/Back

Field-Replaceable
Controller Module

Monitored eConnect PDU, 2U


Front/Back

Preinstalled Adjustable
Depth Mounting Brackets Hydraulic-Magnetic Breakers

Locking Outlets

Field-Replaceable Controller Module


for Horizontal eConnect PDUs

1 Proprietary Auxiliary Ports for Lock Kits

2 Console 2 Port - USB 5


7 8
3 Status LED
3
4 Ethernet Port - RJ45
4 6
1
5 Console 1 Port - RJ45
2
6 USB Type A Ports for Firmware and Temperature/Humidity
Sensors Note: Horizontal eConnect PDUs do not have a LCD Local Display.

7 Secure Array/PDU Linking/Serial Port (link-in)

8 Secure Array/PDU Linking/Serial Port (link-out)

5 chatsworth.com
Monitored eConnect® PDUs
ORDERING INFORMATION

Monitored eConnect PDU, Horizontal - North America


Part Number
Input kW Capacity Form Factor
Redundancy Input Plug Outlets
Black Glacier White Amperage (UL) (U) Height
Pack**
120 Volt, Single-Phase Input

EA-3243-C EA-3243-E EA-3243-CE 20A C20 Inlet to L5-20 (12) 5-20 1.9 kW 1U

EA-3244-C EA-3244-E EA-3244-CE 30A NEMA L5-30P (12) 5-20 2.9 kW 1U

208 Volt, Single-Phase Input

EA-3245-C EA-3245-E EA-3245-CE 20A C20 Inlet to L6-20 (12) C13 3.3 kW 1U

EA-3270-C EA-3270-E EA-3270-CE 20A C20 Inlet to L6-20 (8) C13 + (4) C19 3.3 kW 1U

EA-3246-C EA-3246-E EA-3246-CE 30A NEMA L6-30P (12) C13 5 kW 1U

EA-3253-C EA-3253-E EA-3253-CE 30A NEMA L6-30P (9) C19 5 kW 1U

EA-3271-C EA-3271-E EA-3271-CE 30A NEMA L6-30P (8) C13 + (4) C19 5 kW 1U

120/208 Volt, Three-Phase Input

EA-3248-C EA-3248-E EA-3248-CE 20A NEMA L21-20P (12) C13 5.7 kW 1U

EA-3255-C EA-3255-E EA-3255-CE 20A NEMA L21-20P (9) C19 5.7 kW 1U

EA-3273-C EA-3273-E EA-3273-CE 20A NEMA L21-20P (8) C13 + (4) C19 5.7 kW 1U

EA-3249-C EA-3249-E EA-3249-CE 30A NEMA L21-30P (12) C13 8.6 kW 1U

EA-3256-C EA-3256-E EA-3256-CE 30A NEMA L21-30P (9) C19 8.6 kW 1U

EA-3274-C EA-3274-E EA-3274-CE 30A NEMA L21-30P (8) C13 + (4) C19 8.6 kW 1U

208 Volt, Three-Phase Input

EA-3247-C EA-3247-E EA-3247-CE 30A NEMA L15-30P (12) C13 8.6 kW 1U

EA-3254-C EA-3254-E EA-3254-CE 30A NEMA L15-30P (9) C19 8.6 kW 1U

EA-3272-C EA-3272-E EA-3272-CE 30A NEMA L15-30P (8) C13 + (4) C19 8.6 kW 1U

Notes:**Redundancy Pack includes 2 PDUs in Black and Glacier White for easy identification of the primary and secondary unit.

Monitored eConnect PDU, Horizontal - Worldwide


Part Number kW Capacity kW Capacity
Input Form Factor
Redundancy Input Plug Outlets Worldwide North
Black Glacier White Amperage (U) Height
Pack** (CE) America (UL)

220 - 240 Volt, Single-Phase Input

C20 Inlet to IEC 60309 16A


EA-3250-C EA-3250-E EA-3250-CE 16A (12) C13 3.8 kW 3.8 kW 1U
1P+N+E

C20 Inlet to IEC 60309 16A


EA-3275-C EA-3275-E EA-3275-CE 16A (8) C13 + (4) C19 3.8 kW 3.8 kW 1U
1P+N+E

EA-3252-C EA-3252-E EA-3252-CE 32A IEC 60309 32A 1P+N+E (12) C13 7.7 kW 6.1 kW 1U

EA-3257-C EA-3257-E EA-3257-CE 32A IEC 60309 32A 1P+N+E (9) C19 7.7 kW 6.1 kW 1U

EA-3277-C EA-3277-E EA-3277-CE 32A IEC 60309 32A 1P+N+E (8) C13 + (4) C19 7.7 kW 6.1 kW 1U

220 - 240/380 - 415 Volt, Three-Phase Input

EA-3251-C EA-3251-E EA-3251-CE 16/20A IEC 60309 16/20A 3P+N+E (12) C13 11.5 kW 11.5 kW 1U

EA-3258-C EA-3258-E EA-3258-CE 16/20A IEC 60309 16/20A 3P+N+E (9) C19 11.5 kW 11.5 kW 1U

EA-3276-C EA-3276-E EA-3276-CE 16/20A IEC 60309 16/20A 3P+N+E (8) C13 + (4) C19 11.5 kW 11.5 kW 1U

Notes:**Redundancy Pack includes 2 PDUs in Black and Glacier White for easy identification of the primary and secondary unit.

6 chatsworth.com
Monitored eConnect® PDUs
ORDERING INFORMATION

Monitored eConnect PDU, Horizontal - North America


Part Number
Input kW Capacity Form Factor
Redundancy Input Plug Outlets
Black Glacier White Amperage (UL) (U) Height
Pack**
120 Volt, Single-Phase Input
EA-3401-C EA-3401-E EA-3401-CE 20A C20 Inlet to L5-20 (24) 5-20 1.9 kW 2U
EA-3402-C EA-3402-E EA-3402-CE 30A NEMA L5-30P (24) 5-20 2.9 kW 2U
208 Volt, Single-Phase Input
EA-3403-C EA-3403-E EA-3403-CE 20A C20 Inlet to L6-20 (24) C13 3.3 kW 2U
EA-3459-C EA-3459-E EA-3459-CE 20A C20 Inlet to L6-20 (18) C13 + (6) C19 3.3 kW 2U
EA-3404-C EA-3404-E EA-3404-CE 30A NEMA L6-30P (24) C13 5 kW 2U
EA-3461-C EA-3461-E EA-3461-CE 30A NEMA L6-30P (18) C13 + (6) C19 5 kW 2U
EA-3478-C EA-3478-E EA-3478-CE 30A NEMA L6-30P (6) C13 + (12) C19 5 kW 2U
120/208 Volt, Single-Phase Input
EA-3469-C EA-3469-E EA-3469-CE 30A NEMA L14-30P (12) C13 + (6) C19 + (4) 5-20 5 kW 2U
120/208 Volt, Three-Phase Input
EA-3439-C EA-3439-E EA-3439-CE 20A NEMA L21-20P (24) C13 5.7 kW 2U
EA-3463-C EA-3463-E EA-3463-CE 20A NEMA L21-20P (18) C13 + (6) C19 5.7 kW 2U
EA-3480-C EA-3480-E EA-3480-CE 20A NEMA L21-20P (6) C13 + (12) C19 5.7 kW 2U
EA-3467-C EA-3467-E EA-3467-CE 20A NEMA L21-20P (12) C13 + (6) C19 + (4) 5-20 5.7 kW 2U
EA-3440-C EA-3440-E EA-3440-CE 30A NEMA L21-30P (24) C13 8.6 kW 2U
EA-3464-C EA-3464-E EA-3464-CE 30A NEMA L21-30P (18) C13 + (6) C19 8.6 kW 2U
EA-3482-C EA-3482-E EA-3482-CE 30A NEMA L21-30P (6) C13 + (12) C19 8.6 kW 2U
EA-3468-C EA-3468-E EA-3468-CE 30A NEMA L21-30P (12) C13 + (6) C19 + (4) 5-20 8.6 kW 2U
208 Volt, Three-Phase Input
EA-3441-C EA-3441-E EA-3441-CE 30A NEMA L15-30P (24) C13 8.6 kW 2U
EA-3465-C EA-3465-E EA-3465-CE 30A NEMA L15-30P (18) C13 + (6) C19 8.6 kW 2U
EA-3483-C EA-3483-E EA-3483-CE 30A NEMA L15-30P (6) C13 + (12) C19 8.6 kW 2U
EA-3484-C EA-3484-E EA-3484-CE 50A CS8365 (6) C13 + (12) C19 14.4 kW 2U
EA-3485-C EA-3485-E EA-3485-CE 60A IEC 60309 60A 3P+E (6) C13 + (12) C19 17.2 kW 2U

Notes:**Redundancy Pack includes 2 PDUs in Black and Glacier White for easy identification of the primary and secondary unit.

Monitored eConnect PDU, Horizontal - Worldwide


Part Number kW Form
kW Capacity
Input Capacity Factor
Redundancy Input Plug Outlets North
Black Glacier White Amperage Worldwide (U)
Pack** America (UL)
(CE) Height
220 - 240 Volt, Single-Phase Input
EA-3405-C EA-3405-E EA-3405-CE 16A C20 Inlet to IEC 60309 16A 1P+N+E (24) C13 3.8 kW 3.8 kW 2U
EA-3460-C EA-3460-E EA-3460-CE 16A C20 Inlet to IEC 60309 16A 1P+N+E (18) C13 + (6) C19 3.8 kW 3.8 kW 2U
EA-3406-C EA-3406-E EA-3406-CE 32A IEC 60309 32A 1P+N+E (24) C13 7.7 kW 6.1 kW 2U
EA-3462-C EA-3462-E EA-3462-CE 32A IEC 60309 32A 1P+N+E (18) C13 + (6) C19 7.7 kW 6.1 kW 2U
EA-3479-C EA-3479-E EA-3479-CE 32A IEC 60309 32A 1P+N+E (6) C13 + (12) C19 7.7 kW 6.1 kW 2U
220 - 240/380 - 415 Volt, Three-Phase Input
EA-3442-C EA-3442-E EA-3442-CE 16/20A IEC 60309 16/20A 3P+N+E (24) C13 11.5 kW 11.5 kW 2U
EA-3466-C EA-3466-E EA-3466-CE 16/20A IEC 60309 16/20A 3P+N+E (18) C13 + (6) C19 11.5 kW 11.5 kW 2U
EA-3481-C EA-3481-E EA-3481-CE 16/20A IEC 60309 16/20A 3P+N+E (6) C13 + (12) C19 11.5 kW 11.5 kW 2U
EA-3486-C EA-3486-E EA-3486-CE 32A IEC 60309 32A 3P+N+E (6) C13 + (12) C19 23 kW 18.4 kW 2U

Notes:**Redundancy Pack includes 2 PDUs in Black and Glacier White for easy identification of the primary and secondary unit.

7 chatsworth.com
Monitored eConnect® PDUs

PLUG/INLET TABLE POWER RECEPTACLE/OUTLET TABLE


Single-Phase Receptacles/
Outlets

NEMA L5-20P NEMA L5-30P NEMA L6-20P NEMA L6-30P IEC C20 NEMA 5-20R IEC C13 IEC C19
110-125 VAC/20A 110-125 VAC/30A 200-240 VAC/20A 200-240 VAC/30A 200-240VAC/20A 120 VAC/20A 100-240V/10A 200-240 VAC/16A

IEC 16A 1P+N+E IEC 32A 1P+N+E


200-240VAC/16A 200-240VAC/32A

Three-Phase

NEMA L15-20P NEMA L15-30P NEMA L21-20P NEMA L21-30P NEMA L22-20P NEMA L22-30P 50A CS8365 IEC 60A 3P+E IEC 100A 3P+E
208 VAC/20A 208 VAC/30A 120/208 VAC/20A 120/208 VAC/30A 240/415 VAC, 20A 380/415 VAC/30A 208 VAC/50A 208V/60A 208V/100A

IEC 16A 3P+N+E IEC 32A 3P+N+E IEC 60A 3P+N+E IEC 100A 3P+N+E
240/415VAC/16A 240/415VAC/32A 240/415VAC/60A 240/415VAC/100A

ACCESSORIES

Extended Limited Warranties


Extended Limited Warranties on CPI-Branded Part
Description
Electronic products, available for two additional Number
years beyond the expiration of the Original
L1-2YEXTWAR- 2-Year Warranty Extension
Warranty Period (3 years).
ELECTRONICS-C for PDUs with MSRP up to $1700
Contact CPI Customer Service, or visit L2-2YEXTWAR- 2-Year Warranty Extension
chatsworth.com/warranty for more information. ELECTRONICS-C for PDUs with MSRP $1701 - $3400
L3-2YEXTWAR- 2-Year Warranty Extension
ELECTRONICS-C for PDUs with MSRP > $3400

Field-Replaceable Controller Module


Field-replaceable controller module for Shipping
Part
eConnect® Power Distribution Unit (PDU). Description Weight
Number
Compatible with eConnect Monitored, Monitored lb (kg)
Pro, Switched or Switched Pro eConnect PDUs. eConnect Controller 4 (MCM4)
Allows replacement of controller module while 14676-001 1 (0.5)
for Vertical eConnect PDUs
maintaining power to critical loads. Ability to eConnect Controller 4H (MCM4)
use an SD-card to transfer PDU configuration. 14812-001 1 (0.5)
for Horizontal eConnect PDUs
Available in two options, to match to either a
14676-001 Note: Compatible with PDU P/Ns: EA-3xxx, EA-4xxx, EA-5xxx, EA-6xxx.
Vertical or Horizontal eConnect PDU form factor.
Both controller modules include connections
for ethernet, Secure Array IP Consolidation,
temperature and humidity sensors, RFID
Electronic Locks and serial/console interface.
14812-001 Controller module for Vertical eConnect PDUs also
includes a local display.

8 chatsworth.com
Monitored eConnect® PDUs
ACCESSORIES

POWER MANAGEMENT, ENVIRONMENTAL MONITORING


AND PHYSICAL SECURITY INTEGRATION

eConnect® RFID Electronic Lock Kit


Integrate cabinet access control along with Shipping
Part
power management and environmental Description Weight
Number
monitoring under a single network connection,
lb (kg)
one user interface and one user database for eConnect® RFID Electronic Lock Kit
dramatically reduced deployment savings. 14666-001 3 (1.4)
For ZetaFrame Cabinets
Fully compatible with DCIM software. Available Note: Order your ZetaFrame cabinet with eConnect PDUs and RFID Electronic Lock Kit preinstalled.
on vertical Monitored, Monitored Pro,
Switched and Switched Pro eConnect PDUs
that have Field-Replaceable Controller Modules
with AUX ports.

|
Power IQ® (PIQ) for eConnect Power IQ for eConnect Software and License,
| |

With 1-Year Maintenance Plan


|
|
|
| Power IQ® is a data center energy, power,
environmental and access control monitoring
|
|

Part Number of Part Number of


|
|

software that provides out-of-the-box support for Number Licenses Number Licenses
|
|

|
|

eConnect PDUs, Networked Control Module as


36603-001 Up to 10 Devices 36603-020 Up to 200 Devices
|
|

well as devices from many other manufacturers.


|
|

36603-002 Up to 20 Devices 36603-030 Up to 300 Devices


|
|

36603-005 Up to 50 Devices 36603-040 Up to 400 Devices


36603-010 Up to 100 Devices 36603-050 Up to 500 Devices

USB Temperature and Humidity Sensor Additional Accessories


Attaches to the USB port in the PDUs.
Part
Description
Number
14665-001 USB Temperature and Humidity Sensor 3 (1.4)

Simplify ordering, shipping and installation by requesting eConnect

power PDUs and RFID Electronic Lock Kit to be installed in CPI's ZetaFrame
Cabinets before they leave the factory. Request Redundancy Pack for
easy identification of primary and secondary units.

Order locks and PDUs


preinstalled into your cabinet.
Add power. Make it easy.

chatsworth.com
[email protected]
800-834-4969

While every effort has been made to ensure the accuracy of all information, CPI does not accept liability
for any errors or omissions and reserves the right to change information and descriptions of listed
services and products.
©2024Chatsworth Products, Inc. All rights reserved. Chatsworth Products, Clik-Nut, CPI, CPI Passive
Cooling, CUBE-iT, Secure Array, eConnect, Evolution, GlobalFrame, MegaFrame, QuadraRack, RMR, Saf-
T-Grip, SeismicFrame, SlimFrame, TeraFrame, Motive, EuroFrame, Oberon, Velocity and ZetaFrame are
federally registered trademarks of Chatsworth Products. H-Plane, Hi-Bar, In-Plane, M-Frame, NetPoint,
Simply Efficient, Skybar, and Wi-Tile and are trademarks of Chatsworth Products. All other trademarks
belong to their respective companies. Rev.7, 08/24 MKT-60020-726

You might also like