MANUAL
KFU8-FSSP-1.D
Frequency voltage converter
(40 kHz version)
KFU8-DW-1.D
With regard to the supply of products, the current issue of the following doc-
ument is applicable: The General Terms of Delivery for Products and Servic-
es of the Electrical Industry, published by the Central Association of the
Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie
(ZVEI) e.V.) in its most recent version as well as the supplementary clause:
"Expanded reservation of proprietorship"
182828 2008-11
2
KFU8-DW-1.D
1 Introduction ............................................ 5
3 Safety ...................................................... 8
3.1 Symbols relevant to safety .......................................... 8
3.2 Intended use ................................................................. 8
3.3 General safety instructions ......................................... 9
5 Operation .............................................. 12
5.1 Operating mode .......................................................... 12
5.2 Setup mode ................................................................. 14
182828 2008-11
6 Appendix............................................... 23
3
KFU8-DW-1.D
182828 2008-11
4
KFU8-FSSP-1.D
KFU8-FSSP-1.D
Introduction
1 Introduction
Congratulations
You have chosen a device manufactured by Pepperl+Fuchs. Pepperl+Fuchs
develops, produces and distributes electronic sensors and interface modules for
the market of automation technology on a worldwide scale.
Before you install this device and put it into operation, please read the operating
instructions thoroughly. The instructions and notes contained in this operating
manual will guide you step-by-step through the installation and commissioning to
ensure the trouble-free usage of this product. This is useful to you, because with
this you:
• support the safe operation of the device
• can utilize the device’s entire range of functions
• reduce faulty operation and the associated errors
• reduce costs from downtime and incidental repairs
• increase the effectiveness and operating efficiency of your plant.
Store this operating manual somewhere safe in order to have it available for future
work on the device.
Directly after opening the packaging, please ensure that the device is intact and
that the package is complete.
182828 2008-11
5
KFU8-FSSP-1.D
Introduction
Symbols used
The following symbols are used in this manual:
NOTE!
This symbol brings important information to your attention.
Handling instructions
This symbol denotes handling instructions.
Contact
If you have any questions about the device, its functions, or accessories, please
contact us at:
Pepperl+Fuchs GmbH
Lilienthalstraße 200
68307 Mannheim
Telephone: +49 621 776-1111
Fax: +49 621 776-271111
E-Mail: [email protected]
182828 2008-11
6
KFU8-FSSP-1.D
KFU8-FSSP-1.D
Declaration of Conformity
2 Declaration of Conformity
This product has been developed and manufactured in accordance with applicable
European standards and directives.
NOTE!
A Declaration of Conformity can be requested from the manufacturer.
ISO9001
182828 2008-11
7
KFU8-FSSP-1.D
KFU8-FSSP-1.D
Safety
3 Safety
3.1 Symbols relevant to safety
Danger!
This symbol indicates a warning about a possible danger.
In the event the warning is ignored, the consequences may range from personal
injury to death.
Warning!
This symbol indicates a warning about a possible fault or danger.
In the event the warning is ignored, the consequences may course personal injury
or heaviest property damage.
Caution!
This symbol warns of a possible fault.
Failure to observe the instructions given in this warning may result in the devices
and any connected facilities or systems develop a fault or fail completely.
The KFU8* series comprises a range of devices used to display and monitor
periodic signals. The devices can be used as a control cabinet module or for field
applications. Use wiring designed specially for the devices.
8
KFU8-FSSP-1.D
Safety
9
KFU8-FSSP-1.D
KFU8-FSSP-1.D
Product description
4 Product description
4.1 Device description
The frequency voltage/current converter KFU8-FSSP-1.D is a device for displaying
and monitoring periodical signals which occur in almost all areas of process
automation, i.e. from general frequencies to specific speeds.
The input signals are evaluated and converted into a frequency or speed by a
powerful -controller in accordance with the cycle method. The -controller
calculates a voltage or current value proportional to the input frequency and
produces it with a digital/analog converter in accordance with the selected limit
value of the measurement range.
You can select either of the following analog signals:
• 0 V ... 10 V
• 2 V ... 10 V
• 0 mA ... 20 mA
• 4 mA ... 20 mA
The pulse output produces the input frequency which is subdivided by the
adjustable factor of 1 ... 9999.
NOTE!
Close attention was paid to the special case of speed measurement during the
development of the device. The indicators and inputs can therefore occur in Hz or
182828 2008-11
in rpm.
10
KFU8-FSSP-1.D
Product description
NOTE!
All currently available two, three or four-wire proximity switches and incremental
rotary encoders are acceptable as sensors. Moreover, two terminals are reserved
for the connection of proximity switches as per DIN 19234 (NAMUR).
182828 2008-11
11
KFU8-FSSP-1.D
KFU8-FSSP-1.D
Operation
5 Operation
5.1 Operating mode
Signal frequency
The frequency voltage/current converter processes input signals of 0.001 Hz ...
9999 Hz or speeds of 0.02 rpm ... 9999 rpm. Signals not having a duty rate of 1:1
must have a minimum pulse pause or pulse duration of 40 s in order to be
detected with certainty behind the input filter.
NOTE!
Select a wider measurement range.
182828 2008-11
12
KFU8-FSSP-1.D
Operation
message
During the measurement of very low signal frequencies, the measuring system has
detected that the signal has fallen below the last computed frequency. The time
between the last two signal edges has already elapsed. The device is now waiting
for the next positive signal edge in order to compute the next measured value.
Here, 'XXX' represents the positions of the first three digits of the last measured
value.
Error message
NOTE!
182828 2008-11
If, when switching on again, the error message appears, then the
factory presets were loaded.
13
KFU8-FSSP-1.D
Operation
NOTE!
You can modify the parameters in the parameter value display (flashing digits). The
parameters come into effect temporarily until the operating voltage is interrupted.
14
KFU8-FSSP-1.D
Operation
"Enter" and Closes parameter editor and stores all parameters in the EEPROM.
"+"
Button functions for the parameter value display (one digit flashes)
15
KFU8-FSSP-1.D
Operation
Pulse divider
(factory preset: 1 pulse/revolution)
Applications involving slow processes are frequently equipped with sensors which
provide several pulses per revolution. In the rotational speed measuring function,
the device undertakes the conversion to the actual value of rpm by inputting the
numerical value (of pulses/revolution), i.e. both the indication and the input of the
measurement range end value are obtained from the actual rate of rotation of the
drive.
Range: 1 ... 1200
Teaching in
Press the "Mode" button only and then press "Enter".
182828 2008-11
The frequency or speed of the current pending input signal are taught in.
16
KFU8-FSSP-1.D
Operation
Analog output
(factory preset: 0 V ... 10 V)
Selection of the analog output signal. You can only use the current output
(terminals 5 and 6) or current output (terminals 4 and 5).
0 0 V ... 10 V
1 2 V ... 10 V
2 0 mA ... 20 mA
3 4 mA ... 20 mA
Display function
(factory preset: frequency or speed)
The display shows the determined frequency or speed in Hz and rpm (depending
on Function selection) or the output voltage in V or the output current in mA
(depending on the selection in the Analog output) menu item.
182828 2008-11
17
KFU8-FSSP-1.D
Operation
0 0 - Frequency in Hz
1 - 0 Voltage in V
- 1 Voltage in V
- 2 Current in mA
- 3 Current in mA
Display rate
(factory preset: 0.33 s)
In order to ensure good readability of the display, the time taken to indicate the
current measured value in the display can be selected between 0.01 s and 2.5 s.
NOTE!
The display rate influences neither the time required to calculate the measured
value nor the switching characteristics of the output relay.
182828 2008-11
18
KFU8-FSSP-1.D
Operation
Example:
The maximum permissible rotational speed of the drive is 600.5 rpm. You can
select the first two measuring ranges. Select the second measurement range in
order to fully utilize the accuracy of the display.
Message
This message appears when an attempt has been made to change the range in
such a way that previously input limiting values lie outside the display and
182828 2008-11
measuring range, or the respective places following the decimal point would be cut
off.
19
KFU8-FSSP-1.D
Operation
approx. 10 µs approx. 10 µs
With division factors greater than 1, the pulse output goes to approx. 20 s after the
first positive input signal slope.
For even division factors the output level goes approx. 20 s after the ‘division
factor’/2-period to low level for the following periods.
182828 2008-11
20
KFU8-FSSP-1.D
Operation
4 periods
Example: 2 periods
division factor = 4
approx. 20 µs approx. 20 µs
For uneven division factors the output level goes approx. 20 s after the (‘division
factor’-1)/2 period to low level for the following periods.
5 periods
Example: 2 periods
division factor = 5
approx. 20 µs approx. 20 µs
182828 2008-11
21
KFU8-FSSP-1.D
Operation
NOTE!
You can only read out the version number of the software.
182828 2008-11
22
KFU8-FSSP-1.D
KFU8-FSSP-1.D
Appendix
6 Appendix
6.1 Technical data
Power supply
Rated voltage 196 ... 250 VAC; 98 ... 127 VAC; 47 ... 63 Hz
20,4 ... 27.6 VDC
Display/controls
Type 4-digit 7-segment display, red, 7 mm digit height
Input 1
Connection Terminals 8-, 9+
Switching point 1,2 ... 2.1 mA, switching hysteresis about 0.2 mA
Impedance 1.2 k
23
KFU8-FSSP-1.D
Appendix
Input 2
Connection Terminals 7+, 13- sensor supply
Terminals 14, 15 npn/pnp input (galvanically isolated)
Connectable sensor types Two, three or four-wire proximity switches, incremental rotary encoders or
externally generated pulses 16 ... 30 V
Sensor supply voltage 19 ... 28 VDC not stabilized; 30 mA short-circuit proof
Switching point high: 16 ... 30 VDC; max. 10 mA by way of an integral voltage current
sink; Ri 3 k
low: 0 ... 6 VDC
Output
Analog voltage output 0 ... 10 VDC; 2 ... 10 VDC; 30 mA max.; resolution: 12 mV; Ri 330
(Term. 5+, 6-)
Analog current output 0 ... 20 mA; 4 ... 20 mA; resolution: 25 A; Ri 600 (terminal 4-, 5+)
Digital incrementing (Ub -3 V), 20 mA, short-circuit proof (Terminals 1-, 2+) with frequency
division Fin /1 ... Fin /9999
Transfer characteristics
Input frequency 40000 Hz, pulse pause/duration: 12 s
24
KFU8-FSSP-1.D
Appendix
Ambient conditions
Ambient temperature -25 ... 50 °C (248 ... 323 K)
Altitude 0 - 2000 m
Conformity
Electromagnetic compatibility EN 50081-2, EN 50082-2
Mechanical data
Degree of protection IP20
Connection Coded, removable terminals, core cross-section: 0.34 ... 2.5 mm2
25
KFU8-FSSP-1.D
Appendix
26
KFU8-FSSP-1.D
Appendix
1 2 3 4 5 6
Drehzahlwächter
Output Speed monitor
7-segment-display
Mode +
107
93
Control keys Enter –
PEPPERL+FUCHS GERMANY
7 8 9 10 11 12
13 14 15 16 17 18
"+": Advance to next parameter selection or increase the value of the flashing digit
"-": Advance to next parameter selection or decrease the value of the flashing digit
"Mode": Display parameter value (right digit flashes) or shift the flashing digit to the left
"Enter": Exit parameter value display, the device now operates temporarily with the altered
parameter.
182828 2008-11
"Enter" and "+": Exit parameter editor, the parameters are now stored in the EEPROM in a non-volatile
manner.
27
KFU8-FSSP-1.D
Appendix
DC Ri ≤ 600 Ω
DC-3-wire DC-3-wire 7
sensor, PNP sensor, NPN Sensor power supply 24 V
L+ L+ mA
7 7, 15 15 I– 4
15 14 Galvanically Ri ≥ 330 Ω
13, 14 13 isolated input for D
L– L– 14 PNP- and NPN-
V
output circuits A U– 6
Encoder, Encoder,
push-pull push-pull 13 Sensor power
L+ L+ supply GND
7 7, 15
15 14
13, 14 13
L– L–
11 2
L+ Pulse output
Power supply 24 V DC 1
12 Sensor power
L– supply GND
16
L1 (230 V)
Power supply 230 V AC 18
3
N Not connected
28
KFU8-FSSP-1.D
Appendix
Operating mode
MODE + + + –
MODE + –
29
KFU8-FSSP-1.D
Appendix
X Analog output
MODE 0 0 V ... 10 V
1 2 V ... 10 V
ENTER 2 0 mA ... 20 mA
3 4 mA ... 20 mA Factory set: X = 0
+ –
MODE Display:
X=0: Frequency or speed
ENTER X=1: Voltage display or current display
Factory set: X = 0
+ –
MODE Display rate:
0.01 s ≤ X.XX ≤ 2.5 s
ENTER Factory set: X.XX = 0.33 s
+ –
MODE Division factor for pulse output:
1 ≤ XXXX ≤ 9999
Factory set: XXXX = 1
ENTER
+ –
MODE
Software-version number:
Can only be read.
ENTER
30
KFU8-FSSP-1.D
182828 2008-11
31
FACTORY AUTOMATION –
SENSING YOUR NEEDS
Worldwide Headquarters
Pepperl+Fuchs GmbH
68307 Mannheim · Germany
Tel. +49 621 776-0
E-Mail: [email protected]
USA Headquarters
Pepperl+Fuchs Inc.
Twinsburg, Ohio 44087 · USA
Tel. +1 330 4253555
E-Mail: [email protected]
www.pepperl-fuchs.com
Subject to modifications TDOCT0647A_ENG / 182828
Copyright PEPPERL+FUCHS • Printed in Germany 11/2008