Calculation Report
Calculation Report
INPUT DATA
Fluid Type: Natural Gas
Fluid Name: Natural Gas
Pipe I.D. (Span): 4.026 in
Wall: 0.237 in
Flow Rates
Minimum:
Normal: 1600 Nm3/hr
Maximum:
Full Scale: 2000 Nm3/hr
CALCULATED DATA (Calculation Performed at Normal Conditions)
GUIDELINES
Structural Limit (Flow): 24155.000 Nm3/hr Primary Element Min Limit of Use: 234.357 Nm3/hr
inH2O@
Structural Limit (DP): 1215.524 Recommended Min Rod Reynolds Number: 6500
68F
Recommended Min DP: 0.1 inH2O@68F
Max. Allow. Pressure@Design Temp 99.2845 bar-g Max. Allow. Temp.:
Design Pressure/Temperature: 5 bar-g 30 C Min. Allow. Temp.:
WARNINGS
NOTES
It is the purchasers sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow
rate, abrasives, contaminants, etc.), when specifying product materials, options, and components for the particular application. Emerson is not in a position to
evaluate or guarantee the compatibility of the process fluid or other process parameters with the product options.
Printed On: 27-Nov-2024