ROSEMOUNT INC.

Rosemount™ 485 Annubar™ Primary Element


CALCULATION REPORT
GENERAL DATA
Customer:
P. O. No:
S. O. No:
Tag No:
Application Name: TESTE
Product Advisor ID:
Calculation Date: 27-Nov-2024
Model No:
PRODUCT DESCRIPTION
Annubar Type: Pak-Lok Line Size: 4 in
Sensor Size: 1 Pipe Sch: 40S
Primary Element Material: 316 Stainless Steel Flow Direction: Horizontal
Mounting Material: 316/316L Stainless Steel Transmitter Connection: Direct Mount
Mounting Type: Compression/Threaded Connection Opposite Side Support: No Opposite Side Support

INPUT DATA
Fluid Type: Natural Gas
Fluid Name: Natural Gas
Pipe I.D. (Span): 4.026 in
Wall: 0.237 in

Normal Operating Conditions


Pressure: 3 bar-g Base Pressure: 14.730 psia
Temperature: 27 C Base Temperature: 32.0 F
Density: 0.192 lb/ft3 Base Density: 0.053050 lb/ft3
Compressibility: 0.990840
Isentropic Exponent: 1.3 Atmospheric Pressure: 14.696 psia
Absolute Viscosity: 0.01027 cP

Flow Rates
Minimum:
Normal: 1600 Nm3/hr
Maximum:
Full Scale: 2000 Nm3/hr
CALCULATED DATA (Calculation Performed at Normal Conditions)

DP at Min Flow: Flow Coefficient: 0.54485


DP at Normal Flow: 4.660 inH2O@68F Rod Reynolds Number (Minimum): 8388.19030
DP at Max Flow: Rod Reynolds Number (Normal): 67105.52237
DP at Full Scale Flow: 7.283 inH2O@68F Gas Expansion Factor: 0.9997
Resonant Frequency: 1149.566 Hz Permanent Pressure Loss:
Wake Frequency: 199.580 Hz at Normal Flow: 0.869 inH2O@68F
Blockage: 0.18659 at Full scale flow: 1.358 inH2O@68F
Velocity at Full Scale Flow: 61.3 ft/sec

GUIDELINES
Structural Limit (Flow): 24155.000 Nm3/hr Primary Element Min Limit of Use: 234.357 Nm3/hr
inH2O@
Structural Limit (DP): 1215.524 Recommended Min Rod Reynolds Number: 6500
68F
Recommended Min DP: 0.1 inH2O@68F
Max. Allow. Pressure@Design Temp 99.2845 bar-g Max. Allow. Temp.:
Design Pressure/Temperature: 5 bar-g 30 C Min. Allow. Temp.:

WARNINGS

NOTES

It is the purchasers sole responsibility to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow
rate, abrasives, contaminants, etc.), when specifying product materials, options, and components for the particular application. Emerson is not in a position to
evaluate or guarantee the compatibility of the process fluid or other process parameters with the product options.
Printed On: 27-Nov-2024