AEC

Unit 5

Linear applications of op-amp

5.1 Idealized analysis of op-amp circuits

An Operational Amplifier is basically a three-terminal device which consists of two high impedance
inputs. One of the inputs is called the Inverting Input, marked with a negative or “minus” sign, ( – ).
The other input is called the Non-inverting Input, marked with a positive or “plus” sign ( + ).

A third terminal represents the operational amplifiers output port which can both sink and source
either a voltage or a current.

In a linear operational amplifier, the output signal is the amplification factor, known as the amplifiers
gain ( A ) multiplied by the value of the input signal and depending on the nature of these input and
output signals, there can be four different classifications of operational amplifier gain.

 Voltage – Voltage “in” and Voltage “out”


 Current – Current “in” and Current “out”
 Transconductance – Voltage “in” and Current “out”
 Transresistance – Current “in” and Voltage “out”

Open Loop Gain (Avo)


The main function of an operational amplifier is to amplify the input signal and the more open loop
gain it has the better. Open-loop gain is the gain of the op-amp without positive or negative feedback
and for such an amplifier the gain will be infinite

Input impedance (ZIN)

Input impedance is the ratio of input voltage to input current and is assumed to be infinite to prevent
any current flowing from the source supply into the amplifiers input circuitry ( IIN = 0 ). Real op-amps
have input leakage currents from a few pico-amps to a few milli-amps.

Output impedance (ZOUT)

The output impedance of the ideal operational amplifier is assumed to be zero acting as a perfect
internal voltage source with no internal resistance so that it can supply as much current as necessary
to the load.

This internal resistance is effectively in series with the load thereby reducing the output voltage
available to the load. Real op-amps have output impedances in the 100-20kΩ range.

Bandwidth (BW)

An ideal operational amplifier has an infinite frequency response and can amplify any frequency signal
from DC to the highest AC frequencies, so it is therefore assumed to have an infinite bandwidth.

With real op-amps, the bandwidth is limited by the Gain-Bandwidth product (GB), which is equal to the
frequency where the amplifiers gain becomes unity.

Offset Voltage (VIO)

The amplifiers output will be zero when the voltage difference between the inverting and the non-
inverting inputs is zero, the same or when both inputs are grounded. Real op-amps have some amount
of output offset voltage.

5.2 Inverting and Non-Inverting Amplifier

Inverting Amplifier
The input signal vi is applied to the inverting input terminal through resistor R1 and non-inverting input
terminal is grounded. The feedback from the output of the inverting terminal is provided through the
feedback resistor Rf.

Since the input is applied to the inverting terminal vo and vi are opposite in polarity and hence the
feedback is negative. Since the non-inverting input terminal is grounded v2=0. Due to virtual short at
the input of op-amp the inverting and non-inverting input terminals are at the same potential.

Therefore, v1 = v2 = 0.

Due to high input impedance of Op-amp the current flowing into its inverting input terminal is zero.
Therefore, the same current flows through R1 and Rf .

i1=if

But i1 = vi – v1 / R1 = vi/R1

i f = v1 – vo / Rf = -vo/Rf

vi/R1 = - vo/Rf

Af = vo/vi = -Rf/R1

Af is the closed loop voltage gain or voltage gain with negative feedback.

Problem :
A 200mV peak to peak sine waveform voltage is applied to Op-amp inverting amplifier with Rf/R1 = 10.
Sketch the output.

Solution

Peak to peak input voltage

2Vm = 200 mV

Vm = 100 mV

Vi= Vm sin wt = 100 sin wt mV

Vo = -Rf/R1 x vi = -10 x 100 sinwt mV

= -1000 sin wt mV

The input and output voltages are shown below.

Non-inverting amplifier

Non- Inverting amplifier is one in which the output is in phase with respect to input that is if you apply
a positive voltage, output will be positive. The output is an non -inverted amplified version of input.

Assuming the op-amp is ideal and applying the concept of virtual short, the voltage at the inverting
terminal is equal to non- inverting terminal.
Applying KCL at inverting node we get

Vi -Vo/ R2 + Vo – 0 / R1 = 0

By rearranging the terms, we will get

Voltage gain Av = Vo/ Vi = (1+ Rf/Ri)

Gain of non- inverting amplifier Av= (1+ Rf/Ri).

Problem

Design a non-inverting amplifier using Op-amp with a closed loop voltage gain of 10.

Af = 1 + Rf/R1 =10

Rf/R1 = 9

Rf = 9 R1

If R1 = 1K

Rf = 9K Ω

In an op-amp inverting amplifier R1 = 1K Ω and Rf = 100KΩ. The DC supply voltage of the


op-amp is ± 15V. Calculate the output voltage if input voltage is 1V.

R1 = 1KΩ Rf = 100KΩ

V+ = 15V and V-=-15V. vi = 1V

Af = -Rf/R1 = -100K/1K = -100

Af = vo/vi

Vo = Af vi

= -100 x 1V = -100V
The output voltage cannot exceed the DC power supply voltage . Since vo is negative and large it is
limited to V-

Vo ≈ V- = -15V

5.3 Differential Amplifier

The differential amplifier amplifies the difference between two voltages making this type of operational
amplifier circuit a Subtractor This type of operational amplifier circuit is commonly known as
a Differential Amplifier.

By connecting each input in turn to 0v ground we can use superposition to solve for the output
voltage Vout. Then the transfer function for a Differential Amplifier circuit is given as:

I1 = V1-Va/R1 ; I2 = V2-Vb/R2 ; If = Va –(Vout)/R3

Summing Point Va =Vb

Vb = V2(R4/R2+R4)

If V2 =0 then Vout = -V1 (R3/R1)


If V1=0 then Vout = V2(R4/R2+R4)(R1+R3/R1)

Vout = -Vout (a) + Vout(b)

Vout = -V1(R3/R1) + V2(R4/R2+R4)(R1+R3/R1)

When resistors, R1 = R2 and R3 = R4 the above transfer function for the differential amplifier can be
simplified to the following expression:

Vout = (V2 -V1)

The output is the difference between the two inputs hence, the op-amp can be used as subtractor.

5.4 Instrumentation Amplifier

The Instrumentation amplifiers consist of three op-amps. In this circuit, a non-inverting amplifier is
connected to each input of the differential amplifier.

This instrumentation amplifier provides high input impedance for exact measurement of input data
from transducers. The circuit diagram of an instrumentation amplifier is as shown in the figure below.

The op-amps 1 & 2 are non-inverting amplifiers and together form an input stage of the
instrumentation amplifier. The op-amp 3 is a difference amplifier that forms the output stage of the
instrumentation amplifier.

Working
The output stage of the instrumentation amplifier is a difference amplifier, whose output V out is the
amplified difference of the input signals applied to its input terminals.

If the outputs of op-amp 1 and op-amp 2 are Vo1 and Vo2 respectively, then the output of the difference
amplifier is given by,

Vout = (R3/R2)(Vo1-Vo2)

The expressions for Vo1 and Vo2 can be found in terms of the input voltages and resistances.

Consider the input stage of the instrumentation amplifier as shown in the figure below.

The potential at node A is the input voltage V1. Hence the potential at node B is also V1, from the
virtual short concept. Thus, the potential at node G is also V 1.

The potential at node D is the input voltage V2. Hence the potential at node C is also V2, from the
virtual short. Thus, the potential at node H is also V 2.

Ideally the current to the input stage op-amps is zero. Therefore, the current I through the resistors R1,
Rgain and R1 remains the same.

Applying Ohm’s law between the nodes E and F,

I = (Vo1-Vo2)/(R1+Rgain+R1) ——————— 1
I = (Vo1-Vo2)/(2R1+Rgain)

Since no current is flowing to the input of the op-amps 1 & 2, the current I between the nodes G and H
can be given as,

I = (VG-VH)/Rgain = (V1-V2)/Rgain ————————- 2

Equating equations 1 and 2,

(Vo1-Vo2)/(2R1+Rgain) = (V1-V2)/Rgain

(Vo1-Vo2) = (2R1+Rgain)(V1-V2)/Rgain —————— 3

The output of the difference amplifier is given as,

Vout = (R3/R2) (Vo1-Vo2)

Therefore, (Vo1 – Vo2) = (R2/R3)Vout

Substituting (Vo1 – Vo2) value in the equation 3, we get

(R2/R3)Vout = (2R1+Rgain)(V1-V2)/Rgain

i.e. Vout = (R3/R2){(2R1+Rgain)/Rgain}(V1-V2)

The above equation gives the output voltage of an instrumentation amplifier. The overall gain of the
amplifier is given by the term (R3/R2){(2R1+Rgain)/Rgain}.

Advantages

 The gain of a three op-amp instrumentation amplifier circuit can be easily varied and controlled by
adjusting the value of Rgain without changing the circuit structure.
 The gain of the amplifier depends only on the external resistors used. Hence, it is easy to set the
gain accurately by choosing the resistor values carefully.
 The input impedance of the instrumentation amplifier is dependent on the non-inverting amplifier
circuits in the input stage. The input impedance of a non-inverting amplifier is very high.
 The output impedance of the instrumentation amplifier is the output impedance of the difference
amplifier, which is very low.
 The CMRR of the op-amp 3 is very high and almost all of the common mode signal will be rejected.

Active filter

Active filters are the electronic circuits, which consist of active element like op-amp(s) along with
passive elements like resistor(s) and capacitor(s).
Active filters are mainly classified into the following four types based on the band of frequencies
that they are allowing and / or rejecting −
 Active Low Pass Filter
 Active High Pass Filter
 Active Band Pass Filter
 Active Band Stop Filter

Active Low Pass Filter

If an active filter allows or passes only low frequency components and rejects or blocks all other
high frequency components, then it is called as an active low pass filter.

The electric network, which is connected to the non-inverting terminal of an op-amp is a passive low
pass filter. So, the input of a non-inverting terminal of an op-amp is the output of a passive low pass
filter.

It produces an output which is (1+Rf/R1) times the input present at the non-inverting terminal.

Active High Pass Filter


If an active filter allows or passes only high frequency components and rejects or blocks all other
low frequency components, then it is called an active high pass filter.

So, the input of a non-inverting terminal of op-amp is the output of passive high pass filter.

The circuit resembles a non-inverting amplifier having the output of a passive high pass filter as an
input to non-inverting terminal of op-amp. Hence, it produces an output, which is (1+Rf/R1) times the
input present at its non-inverting terminal.

Active Band Pass Filter

If an active filter allows only one band of frequencies, then it is called as an active band pass filter.
In general, this frequency band lies between low frequency range and high frequency range. So,
active band pass filter rejects both low and high frequency components.
There are two parts in the circuit diagram of active band pass filter: The first part is an active high
pass filter, while the second part is an active low pass filter.

The output of the active high pass filter is applied as an input of the active low pass filter. That
means, both active high pass filter and active low pass filter are cascaded in order to obtain the
output in such a way that it contains only a particular band of frequencies.
Active Band Stop filters

If an active filter rejects (blocks) a particular band of frequencies, then it is called as an active band
stop filter. In general, this frequency band lies between low frequency range and high frequency
range. So, active band stop filter allows passes both low and high frequency components.

The block diagram of an active band stop filter consists of two blocks in its first stage: an active low
pass filter and an active high pass filter. The outputs of these two blocks are applied as inputs to the
block that is present in the second stage. So, the summing amplifier produces an output, which is
the amplified version of sum of the outputs of the active low pass filter and the active high pass filter.
 P, PI and PID controllers

P Control.

The Output power is directly proportional to control error. The higher the proportion coefficient, the
less the output power at the same control error

Proportional control is mainly for fast-response systems with a large transmission coefficient. To adjust
the proportional controller first set the maximum proportion coefficient where in the output power
decreases to zero.

When the measured value is stabilized, set a specified value and gradually reduce the proportion
coefficient and the control error will decrease.

If there are periodic oscillations in the system, the proportion coefficient should be increased so that
control error is minimal periodic oscillations decrease to the limit.
PI Control.

The Output power equals to the sum of proportion and integration coefficients. The higher the
proportion coefficient, the less the output power at the same control error. The higher the integration
coefficient, the slower the accumulated integration coefficient.

PI control provides zero control error and and is insensitive to interference of the measurement
channel. The PI control disadvantage is slow reaction to disturbances.

To adjust the PI controller first set the integration time equal to zero, and the maximum proportion
time. Then by decreasing the coefficient of proportionality, achieve periodic oscillations in the system.

PID Control.

The Output power equals to the sum of three coefficients: proportional, integral and differential. The
higher the proportion coefficient, the less the output power at the same control error.

The higher the integration coefficient, the slower the accumulated integration coefficient. The higher
the differentiation coefficient, the greater the response of the system to the disturbance.

The PID controller is used in inertial systems with relatively low noise level of the measuring channel.

The advantage of PID is fast warm up time, accurate setpoint temperature control and fast reaction to
disturbances.

 Lead/lag compensator using an op-amp

Lag compensator

A lag compensator is one which adds a pole to the system and is used to improve the steady state
response of the system. A lag compensator provides phase lag negative phase in the frequency
response of system.

Using the concept of virtual ground, the op-amp lag compensator can be redrawn as shown in the
figure
Using voltage divider principle, the transfer function of the system is

Vo/Vs =(1+s*C*R1)/(1+(R1+R2)*s*C),

hence the phase added to system is given as

Ω = tan-1(ω*C*R1) – tan-1(ω*C*(R1+R2))

Since R1<R1+R2 and tan-1(x) is increasing function (if a <b, tan-1(a)< tan1(b)) Ω is negative phase lag.

Lead compensator

A lead compensator is one which adds a zero the system and is used to improve the transient
response of the system. A lead compensator provides phase lead positive phas) in the frequency
response of system

Using the concept of virtual ground, the op-amp lag compensator can be redrawn as shown in the
figure

Using voltage divider principle, the transfer function of the system is

Vo/Vs=(1+s*C*R1)/(1+(R1*R2/(R1+R2))*s*C),

hence the phase added to system is given as

Ω =tan-1(ω*C*R1) -tan-1(ω*C*R1*R2/(R1+R2)).

Since R1 > R1*R2/(R1+R2) Ω is positive(phase lead).

5.5 Integrator
Since the non-inverting input terminal of op-amp is grounded v2=0. Due to
virtual short at the input of op-amp the inverting and non-inverting input
terminals are at the same potential

Therefore v1=v2=0

Due to high impedance of op-amp the current flowing into its input
terminal is zero. Therefore the same current flows through R and C

That is

i1 = if -------------------(1)

where i1 = vi – v1 /R = vi -/R---------------------(2)

and if = C d/dt[v1 – v0] = -C dv0/dt --------------------(3)

Substituting (2) and (3) in (1) we get

vi = - C/R dv0/dt ------------------------(4)

dvo/dt = (-1/RC) vi ---------------------------- (5)

Integrating both sides of eq(5) we get


v0 = - 1/RC + v0(0) --------------------------(6)

where v0(0) is the initial voltage on the capacitor at t=0.

Note: v0(o) represents the constant of integration.

From eq(6) we find that the output voltage is proportional to the integral
of the input voltage.

Therefore v0 = - 1/RC

Problem:

The integrator circuit as shown in the figure has R = 500K Ω and C=1µF.
Find and plot the output voltage for the inputs as shown in the figure.
c)vi= 2 sin 4tV d) vi= 4tV

Solution:

We know that

v0 = - 1/RC + v0(0)

Here R= 500K Ω and C = 1µF

1/RC = 1/ 500 x 1000 x 1 x 10 -6

= 1/RC = 2

= -2 ; vi =- 5V

= -2

= 10t V

Which means it is a ramp voltage with positive slope.


When vi=5V

-2 ; vi = 5V

= -2

= -10t V

Which means it is a ramp voltage with negative slope.


When vi= 2 sin4t V

Vo = -2

= -4 [-cos 4t] /4

= cos 4t
When vi=4t V

Vo =

= -8 [t2/2]

= - 4V

5.6 Voltage Regulator

By utilizing an op-amp and few other external components, linear voltage


regulator is built The same circuit is also a voltage stabilizer, able to
stabilize voltage at a grade better than The transistor is used to supply the
load with much more current than the op-amp itself could possibly supply.

The D1 diode is a Zener -type diode and it is used for voltage reference.
Basic op-amp voltage regulator

D1 is biased through Rz. When correctly reserve biased, the Zener diode
keeps the voltage across its leads close to the Zener breakdown voltage. The
op-amp is used as a linear voltage amplifier.

Due to the high open loop voltage gain of the op-amp the op-amp remains in
its linear region, the voltage difference between its inverting (V ) and non-
-

inverting input (V ) is almost equal to zero.


+

In other words, the voltage at its non-inverting input, in respect to the


ground, equals the voltage at its inverting input:

V =V
- + -------(1)

Equation (1) holds true for any op-amp working at its linear region (as an
amplifier).

R1 and R2 form a voltage divider, and the voltage (V ) at their connection


-

point is also given by the well- known voltage-divider formula:

V =V ·R1/(R1+R2) ------
- L (2)

However, V+ is also equal to the Zener breakdown voltage (Vz), because the
non-inverting input of the op-amp is directly connected to the cathode of the
Zener diode.

V =V -----------------(3)
+ Z

After solving (1),(2) and (3), we get:


V =V ·(1+R2/R1)
L Z --------------(4)

From equation (4), we conclude that V voltage which is the voltage applied
L

to the load is directly proportional to the Zener voltage.

As long as Zener voltage remains stable, V also remains stable. Additionally,


L

the voltage applied to the load, can be easily adjusted by adjusting R1, R2 or
both. For continues voltage adjustment, R1 and R2 can be replaced by a
potentiometer, having its wiper at the non-inverting input of the op-amp, and
its other leads at the ground and the V line, respectively.
L

5.7 Oscillators
 Wein Bridge Oscillators

Wien bridge oscillator is an audio frequency sine wave oscillator of high


stability and simplicity. The feedback signal in this circuit is connected to the
non-inverting input terminal so that the op-amp is working as a non-inverting
amplifier.

The feedback network does not provide any phase shift. The circuit can be
viewed as a Wien bridge with a series combination of R1 and C1 in one arm
and parallel combination of R2 and C2 in the adjoining arm. Resistors R3 and
R4 are connected in the remaining two arms.

The condition of zero phase shift around the circuit is achieved by balancing
the bridge. The series and parallel combination of RC network form a lead-
lag circuit.

At high frequencies, the reactance of capacitor C1 and C2 approaches zero.


This causes C1 and C2 appears short. Here, capacitor C2 shorts the resistor
R2. Hence, the output voltage Vo will be zero since output is taken across R2
and C2 combination. So, at high frequencies, circuit acts as a 'lag circuit'.

At low frequencies, both capacitors act as open because capacitor offers very
high reactance. Again, output voltage will be zero because the input signal is
dropped across the R1 and C1 combination. Here, the circuit acts like a 'lead
circuit'.

But at one particular frequency between the two extremes, the output
voltage reaches to the maximum value. At this frequency only, resistance
value becomes equal to capacitive reactance and gives maximum output.
Hence, this frequency is known as oscillating frequency (f).
Consider the feedback circuit, on applying voltage divider rule

Vf(s) = Vo(s) x Zp(s)/ Zp(s) + Zs(s)

Zs(s) = R1 + 1/sC1 and Zp(s) = R2|| 1/sC2

Let R1=R2=R and C1=C2=C . On solving

β = V (s)/ Vo(s) = RsC /(RsC) + 3RsC + 1 ---------------------------(1)


f
2

Since the op-amp is operated in the non-inverting configuration the voltage


gain

Av = Vo(s)/ Vf(s) = 1 + R3/R4 -------------------(2)

Applying the condition for sustained oscillations, = Av β =1

RsC /(RsC) + 3RsC + 1. 1 + R3/R4


2

S=jw

(1 + R3/R4) ( jwRC/ - R C w + 3 jwRC + 1) =1


2 2 2

jw RC (1 + R3/R4)= (- R C w + 3 jwRC + 1)
2 2 2

jw[(1 + R3/R4)RC – 3RC] = 1- R C w 2 2 2

To obtain the frequency of oscillation equate the real part to zero

1- R C w = 0
2 2 2

w = 1/RC

f = 1/ 2 π RC

To obtain the condition for gain at the frequency of oscillation equate the
imaginary part to zero.

jw[(1 + R3/R4)RC – 3RC] = 0

jw[(1 + R3/R4)RC= jw3RC


[(1 + R3/R4) =3

R3/R4 =2

Therefore R3 = 2 R4 is the required condition.

Phase Shift oscillator

In an RC Oscillator circuit, the input is shifted 180 through the feedback


o

circuit returning the signal out-of-phase and 180 again through an inverting
o

amplifier stage to produces the required positive feedback.

This then gives us “180 + 180 = 360 ” of phase shift which is effectively the
o o o

same as 0 , thereby giving us the required positive feedback.


o

In other words, the total phase shift of the feedback loop should be “0” or
any multiple of 360 to obtain the same effect.
o
The circuit on the left shows a single resistor-capacitor network whose output
voltage “leads” the input voltage by some angle less than 90 . o

In a pure or ideal single-pole RC network. it would produce a maximum


phase shift of exactly 90 , and because 180 of phase shift is required for
o o

oscillation, at least two single-poles networks must be used within an RC


oscillator design.

However, in reality it is difficult to obtain exactly 90 of phase shift for each


o

RC stage so we must therefore use more RC stages cascaded together to


obtain the required value at the oscillation frequency.

The amount of actual phase shift in the circuit depends upon the values of
the resistor (R) and the capacitor (C), at the chosen frequency of oscillations
with the phase angle ( φ ) being given as:

Xc = 1/2π fc R=R

Z = [ R + Xc ]
2 2 ½

Ø = tan -1
Xc /R
5.8 Analog to Digital Converter

Analog to digital converter samples the analog signal on each falling or rising
edge of sample clock. In each cycle, the ADC gets of the analog signal,
measures and converts it into a digital value. The ADC converts the output
data into a series of digital values by approximates the signal with fixed
precision.

In ADCs, two factors determine the accuracy of the digital value that
captures the original analog signal. These are quantization level or bit rate
and sampling rate.

The figure depicts how analog to digital conversion takes place. Bit rate
decides the resolution of digitized output

The figure displays 3-bit ADC is used for converting analog signal.

Assume that one volt signal has to be converted from digital by using 3-bit
ADC as shown below. Therefore, a total of 2^3=8 divisions are available for
producing 1V output. This results 1/8=0.125V is called as minimum change
or quantization level represented for each division as 000 for 0V, 001 for
0.125, and likewise upto 111 for 1V. If we increase the bit rates like 6, 8, 12,
14, 16, etc. we will get a better precision of the signal. Thus, bit rate or
quantization gives the smallest output change in the analog signal value that
results from a change in the digital representation.

References:
 Analog devices by S.N . Ali
2. Electronic Devices and Circuits by VENKATA RAO, McGraw Hill

3. Microelectronic circuits by Smith

4. Analog Electronic circuits by A.P Godse

5. Analog Electronic circuits by J.B Gupta.