VRLA Battery P E R F O R M A N C E DATA

CPC 135-12 Cyclic AGM battery (600 cycles)


Dimensions (mm) Standard terminal (mm)

287
341 M8

M8 Insert

Typical applications Nominal voltage 173 12 V


Nominal capacity (1.70V/c, 25⁰C) 20Hr: 144.0 Ah
• Electric vehicles
• Mobility scooters 10Hr: 135.0 Ah
• Electric wheelchairs 5Hr: 118.0 Ah
• AGV and warehouse equipment 1Hr: 80.0 Ah
• Medical equipment Internal resistance ≤3.8mΩ (fully charged)
• Solar energy
Maximum charge current 40.2 A
• Recreational vehicles
Maximum discharge current 950 A (max. 5 sec)
• Marine
• Camper and caravan Number of cycles 600 (50% D.O.D.)
Float use / cyclic use 13.6 - 13.8V / 14.5 - 14.9V
Features Charge temperature range -10⁰C ~ 60⁰C
• Valve Regulated Lead Acid (VRLA) Discharge temperature range -20⁰C ~ 60⁰C
• Maintenance free Standard terminal Insert M8 (19 Nm torque)
• Absorbent Glass Mat Technology (AGM)
Housing material ABS (UL94-HB)
• Low self discharge
• Designed for cyclic use Dimensions Length 341 mm
• Can be discharged or stored in any Dimensions Width 173 mm
position without leakage
• Battery cannot be charged while upside
Dimensions Height 287 mm
down Approximate Weight 40.00 kg
• Produced under ISO 9001 & ISO 14001 Packing 1 pcs / box

Recommended
Restrictions
This battery is classified as non spilla- Having the right battery is often just
ble and is therefore not restricted for the beginning. Optimal use of a battery
transport under ADR regulations (road requires having a good battery charger,
transport), IMDG code (sea transport) and so that the user can be sure that their
IATA regulations (air transport). battery is always optimally charged and
has maximum lifespan.
Built to comply with Cellpower offers various intelligent bat-
• DIN 43534 tery chargers, as well as battery testers,
battery monitors and battery guards. All
• IEC896-2
designed to easily monitor the battery
• BS6290-pt.4 quality and make sure the battery re- Recommended for CPC 135-12: L CP 12-20 battery charger
mains in the best condition possible.

WWW.CELLPOWERBATTERIES.COM | [email protected] CPC 135-12 Datasheet V2.0 PAGE 1 OF 2


VRLA Battery P E R F O R M A N C E DATA

Charge characteristics Capacity in relation to temperature

0.21 15 Charge voltage 140


12 0
0.18 14 120
me 0. 05CA
Charge volu 0. 1CA
10 0
Charge Current (CA)

Charge Voltage (V)

0.15 13 100

Charge Volume (%)


-Discharge 0. 25CA
100%(0.05CA x 20h) 80 0. 6CA

Capacity (%)
0.12 12 50%(0.05CA x 10h) 80
1CA
-Constant Voltage Charging
Charge voltage: 2.45V/cell
60 2CA
0.09 11 60
Charge current: 0.1CA
40
0.06 10 40

0.03 20 20
Charge current
0 0 0 0
0 5 10 15 20 25 -2 0 -1 0 0 10 20 30 40 50 60
Charge time (hr)

Charge voltage in relation to temperature Cycle service life in relation to depth of discharge
Testing conditions: Discharge current 0.17CA (FV 1.70V/cell) CPC serie
2.60 CPX serie
Ambient temperature: 25°C
CPG serie
2.55 120

2.50
Charge voltage per cell (V)

Cyclic Voltage 100


2.45

2.40 80
Capacity (%)

2.35

2.30 60
100% 50% 30%
D.O.D D.O.D D.O.D
2.25 Float Voltage
40
2.20
2.15 20

2.10
-20 -10 0 10 20 30 40 50 0
0 200 400 600 800 1000 1200 1400 1600 1800
Number of cycles

Models available Cellpower family

Capacity Dimensions Weight Cellpower supplies a broad range of reliable AGM, GEL and Li-
Model Voltage
(Ah) (mm) (kg) thium batteries. Each product series has its own unique charac-
CPC 225-6 6 225 243x187x276 33.00 teristics, so that there is a suitable battery for every application
CPC 9-12 12 9.0 151x65x100 2.80
with its associated specific usage profile. Combined with the
CPC 10-12 12 10 151x65x118 3.30
CPC 12-12 12 12 151x98x98 3.90 right Cellpower battery accessories, you are able to assemble a
CPC 18-12 12 18 181x76x167 6.08 high-quality and reliable battery system.
CPC 24-12 12 24 175x166x125 9.30
CPC 33-12 12 33 197x131x170 10.50 The sealed, maintenance-free AGM lead battery type has a long
CPC 38-12 12 38 198x166x171 13.30 operational lifetime. When used correctly, the Absorbent Glass
CPC 38-12S 12 38 197x131x168 10.70 Mat (AGM) technology offers dependable, lasting service. Addi-
CPC 50-12 12 50 198x166x171 14.30 tionally, AGM batteries
CPC 55-12 12 55 226x135x214 17.00
exhibit very little self-
CPC 62-12 12 62 226x135x214 18.70
CPC 75-12LW 12 75 260x170x207 24.40 discharge when com-
CPC 80-12AJ 12 80 353x174x190 25.70 pared with other lead-
CPC 90-12 12 90 306x169x215 29.00 acid batteries. Sealed
CPC 110-12 12 110 330x171x220 30.00 lead-acid batteries re-
CPC 120-12 12 120 408x176x227 37.00 quire low maintenance
CPC 135-12 12 135 341x173x287 40.00
CPC 150-12 12 150 482x170x240 44.50
and do not need to be
CPC 160-12 12 160 530x209x220 55.50 refilled with water or
CPC 200-12 12 200 522x238x223 62.50 other liquids.
CPC 250-12 12 250 520x269x227 74.00

WWW.CELLPOWERBATTERIES.COM | [email protected] CPC 135-12 Datasheet V2.0 PAGE 2 OF 2