NETYS RT Data Sheet
NETYS RT Data Sheet
> Switching
> Storage
> Servers and networking
devices
> VoIP communication systems
> Structured cabling systems
> Control systems
> Video surveillance systems
Certifications
GAMME 110 A
Advantages
Technical data
NeTYS RT
Sn 1100 VA 1700 VA 2200 VA 3000 VA 5000 VA 7000 VA 9000 VA 11000 VA
Pn 800 W 1200 W 1600 W 2100 W 4500 W 5400 W 7200 W 9000 W
Architecture online double conversion VFI with input PFC and automatic bypass
Parallel redundant function - - - - 1+1 1+1 1+1 1+1
INPUT
Voltage 230 V (1ph) 160~275 Vac; up to 130 Vac @70% load 230 V (1ph) 181~280 Vac up to 100 Vac @50% load
Frequency 50/60 Hz +/-10% (Auto-Selectable)
Power factor / THDi >0.98 / <6% >0.99 / <5%
OUTPUT
Voltage 230 V (1ph) selectable 200 / 208 / 220 / 240V - 50 or 60 Hz + /- 2 % (+/- 0.05 Hz in battery mode)
Efficiency up to 91% online mode up to 92% online mode
Overload capability up to 105% continuously; 125% x 3 min; 150% x 30 sec up to 105% continuously; 125% x 5 min; 150% x 30 sec
6 x IEC 320-C13
Output connections 6 x IEC 320-C13 (10 A) + 1 x IEC 320-C20 (16 A) terminals
(10 A)
BATTERY
Standard autonomy* 8 12 8 10 8 6 8 6
Voltage 24 Vdc 48 Vdc 48 Vdc 72 Vdc 192 Vdc 192 Vdc 240 Vdc 240 Vdc
Recharge time < 6h to recover 90% capacity < 4h to recover 90% capacity
COMMUNICATION
Mimic panel LED LCD 6 languages
RS232 (DB9 port) Jbus protocol • • • • • • • •
USB HID protocol • • • • - - - -
WEB/SNMP (Ethernet RJ45 port) option option option option • • • •
COMM slot • • • • • • • •
Dry contacts card option option option option option option option option
EPO input (RJ11 port) • • • • • • • •
Modem/ADSL surge protection • • • • - - - -
Parallel port - - - - • • • •
STANDARDS
Performance & topology EN 62040-3 (VFI-SS-111)
Safety /EMC EN 62040-1 (TÜV-GS certified) EN 62040-2
Product certifications CE, TÜV-GS, C-Tick
IP rating IP20
ENVIRONMENT
Operating ambient temperature from 0 °C to +40 °C (from 15 °C to 25 °C for best battery life)
Storage temperature range from -15 °C to +50 °C (from 15 °C to 25 °C for best battery life)
Relative Humidity 5-95% non-condensing
Noise level (ISO 3746) < 45 dB < 55 dB
DIMENSIONS & WEIGHT
UPS size std (W x D x H) 88.7 x 332 x 440 mm 88.7x 430 x 440 mm 88.7 x 430 x 440 mm 88.7 x 608 x 440 mm 177.4 x 670 x 440 mm 177.4 x 670 x 440 mm 261.2 x 623 x440 mm 261.2 x 623 x 440 mm
UPS size RACK 2U 2U 2U 2U 2U+2U 2U+2U 3U+3U 3U+3U
UPS weight std 13 kg 21 kg 22 kg 31 kg 15.5+40 kg 16+40 kg 19.5+66 kg 20+66 kg
EBM module size (W x D x H) 88.7 x 332 x 440 mm 88.7x 430 x 440 mm 88.7x 430 x 440 mm 88.7 x 608 x 440 mm 88.7 x 608 x 440 mm 88.7 x 608 x 440 130.6 x 623 x 440 mm 130.6 x 623 x 440 mm
EBM module RACK 2U 2U 2U 2U 2U 2U 3U 3U
EBM module weight 16 kg 29 kg 29 kg 43 kg 40 kg 40 kg 66 kg 66 kg
* @ 75% of nominal load.
9 11
4 4
5 5
6 6
9 9
NETYS 066 A
NETYS 067 A
10 10
11 7
7
1100 VA 1700 VA - 2200 VA - 3000 VA
10 10
5 16
17 5
6 17
11 11
2
2
2
15
15 15
13 13
14 14
5000 VA - 7000 VA + battery 9000 VA - 11000 VA + battery
NRT-U2200 2 x NRT-B2200
load sharing, whereby both units are always
NRT-U3000 Internal kept active.
NRT-U3000 1 x NRT-B3000 In a redundant configuration, overall system
UPS + 2 EBM NRT-U3000 2 x NRT-B3000 availability is much higher than a conventional
50% of nominal load 75% of nominal load 100% of nominal load UPS system using similar technology.
1+1 redundant configuration does not
require additional circuits and can therefore
N TYS RT 5000-11000 VA - Battery extension be set up at a later date, simply by using
two UPS modules and a collector / manual
bypass module which simplifies cabling and
UPS EBM Back up time (minutes) maintenance of the UPS installation.
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170
NRT-5000K Standard To further streamline the solution, it is also
possible to select between operation with
NRT-5000K 1 x NRT-B7000
separate battery or shared battery, which is
UPS NRT-5000K 2 x NRT-B7000 extremely useful in the case of applications
(standard)
NRT-7000K Standard requiring high levels of autonomy.
NRT-7000K 1 x NRT-B7000
NRT-7000K 2 x NRT-B7000
NRT-9000K Standard
UPS + 1 EBM
NRT-9000K 1 x NRT-B11000
NETYS116 A - NETYS 119 A GB
NRT-9000K 2 x NRT-B11000
NRT-11000K Standard
NRT-11000K 1 x NRT-B11000
UPS + 2 EBM NRT-11000K 2 x NRT-B11000
50% of nominal load 75% of nominal load 100% of nominal load
Lo
ad
NETYS 117 A GB
Lo
ad
Control panel
1 1 1. Yellow LED lit. Operation in bypass mode
2 8 2. Green LED lit. Mains healthy
4 4
9 3. OFF button
4. Green LED lit. Normal operation (inverter
in-line)
5. ON / TEST and buzzer override button
6. LED bar. Depending on the situation, this
indicates either the charge level or the
capacity of the battery
7. Navigator buttons
8. Alphanumeric LCD display
S 108 A
NETYS 1
5 5
6 7
3 2
3