The users should have general information on water, hydrological cycle, basic
Pre-requisites
definitions like discharge, water flow and head of water
To understand the various water measure techniques available for measurement of
Objectives flowing water and assess their relevance in today’s current scenario
Introduction
Water was always a precious resource, today it is a scarce resource as well. With rising
development, the demand for water is increasing. Water is needed for agriculture, industries,
municipalities, commercial use, recreation, environmental flow in rivers amongst many others. Water
allocation to various sectors would involve estimation of water requirements at storage facilities,
estimation of losses incurred in conveyance and actual water consumption. The measurement
techniques that are discussed in these modules are for open channel flow measurement and pipe flow
measurement.
Good water measurement techniques lead to detection of losses in the urban water distribution
system and in water delivery in the agriculture sector. In case of urban areas, the pipe distribution
network is monitored for water losses (water losses are dependent on the age of pipes amongst other
defects) so that the water utility provider can determine the amount of water lost in supply and make
reassessments. On the consumer side when individual water use is accounted for, together with water
pricing policies excess water use can be brought under control. The flow measuring devices are used
to measure wastewater flow too in urban areas. This is very important considering the fact that both
dry weather flow and mixing of sewage effluent with storm water flow during rainy season determine
the load on the waste water treatment system.
In case of irrigation networks, the canal system is monitored for water losses. The canal lining
and canal age plays an important role in water losses. If measurement techniques are in place then
water supply assessment can be made, while if assessment is carried out in agriculture fields, the water
usage at field level is quantified. Amongst other benefits of water measurement in field level, one
3
In case of open channel flow or stream flow, both direct and indirect measurement techniques
are used. The direct methods of measurement of stream discharge include:
a. Area velocity methods
b. Dilution techniques
c. Electromagnetic method
d. Ultrasonic method
Measuring stream discharge continuously is generally not practiced; normally stage discharge (curves)
relationship is established. For this the discharge in a given stream is related to the water elevation in
the stream (stage) through a series of measurements. In order to measure stage (depth of water in the
stream), we use staff gauge (vertical single staff gauge and sectional staff gauge). Stage measurement
is carried out using staff gauge (manual gauge). The manual gauge is fixed to a structure like bridge
abutment, pier as shown below. It should be vertical with no inclination; the markings should be clear.
There should be no hindrance in taking the reading, the water surface elevation of the stream should be
clearly visible. When the depth of the stream is large, there are large fluctuations, sectional gauges are
used. They are also manual gauges which can measure large variation in water depth. Care should be
4
Sometimes wire gauges are used to measure depth of a stream, by hanging a wire with attached
weights from a bridge or other structure and depth is measured.
Automatic stage recorders are now used more often than manual stage recorders and the reading may
be recorded continuously. A float gauge recorder is typically housed in a stilling well as shown in the
diagram below. The float is balanced with a counter weight over a pulley system which is attached to a
recorder. The displacement of the float due to change in water surface elevation causes an angular
displacement in the pulley, which causes movement in the recorder. The recorder records stage versus
time data continuously. In the latest system stage versus time data recorded is transmitted through the
satellite so that instantaneous records are available.
The stilling well allows water to come from the stream through intake pipes, so that the float and
recorder are protected from debris and even when flood inundation takes place. Care should be taken
to see that the stage recorder is placed above the highest water level that may be reached at that site.
The arrangement of the stilling well installation is such that in functions in all weather conditions.
Many times a bubble gauge type recorder is used in which case compressed air or gas bubble is
released through an outlet placed at the bottom of the stream. The advantage of such recorders is that it
does not need a stilling well arrangement and the recorder assembly can be placed far away from the
stream. The other important characteristic of direct determination of discharge is the estimation of
velocity. Velocity is measured by many methods. The first is as follows:
Current Meters
The current meters can be both vertical axis and horizontal axis current meters. The current meter is
used to measure velocity at a point across the cross section of the stream. The vertical axis current
The normal range of velocities recorded is between 0.15-4.0m/s. The current meter is designed in such
a manner that the number of revolutions of the meter is related to the linear velocity as follows:
v=aNs+b
where v is the stream velocity at the instrument location in m/s,
Ns is the number of revolutions per section of the current meter and a,b are constants.
The vertical current meters are easy to use, however, whenever there is appreciable velocity difference
with depth, they are not that accurate, under such circumstances the horizontal axis current meter may
be used. The cups are of standard diameter 12.5cm and the constant values of a and b are at a=0.65 and
b=0.03. In case of broad streams, current meters are carried in boats.
Calibration is carried out to determined values of a and b in a special tank (towing tank) which
contains still water. The instrument is run over the entire range of velocities (each time the speed is
kept constant at a certain value, the number of revolutions per second, Ns is measured). Over the entire
range of velocities and revolutions, Ns, graph is plotted linearly, and equation constants a and b are
determined.
In the field, velocity is measured at a chosen cross section where there is least resistance to flow.
Depending on the depth of the stream, since stream velocity is subjected to friction resistance from
Stream velocity can also be measured with the help of floats also, these are generally used for
preliminary investigations, in case of small streams, and streams in which there is rapid change in
water surface. A simple floating object is measured for the distance travelled over a period of time.
This gives the surface velocity, many times a series of floats are released along the width of the stream
a regular interval, so that an average velocity can be determined.
The area velocity method is used to determine the discharge of the stream at the selected cross-
sectional area otherwise called the gauging site. The stream is divided into sections as shown in the
figure 4, at each of these sub sections the average velocity is measured, the area of the sub section is
determined by measuring the depth and the width of the subsection. The discharge at each of these
subsections is the cross-sectional area multiplied by the average velocity at the sub section (the
velocity being measured by the current meter method as explained above). The discharge estimation at
the gauging site is the summation of all these individual discharges. Discharge is the volume of water
flowing through the stream or river at a certain time, so it is measured as
The area velocity method is thus the summation of individual discharges as measured below
∑Q =∑AV,
A rating curve is drawn plotting the discharge measured by area velocity method on the y axis and
the measured stage depth at the gauging station on the x axis. The more the number of measurements
of discharge and corresponding stage height, better is the representative plotted curve. The best fit
The dilution technique of stream flow uses tracers which may be chemicals, fluorescent dyes or
radioactive materials. An initial high quantity of tracer is mixed in a small discharge and then the
concentration of the diluted quantity is measured at another section using steady state continuity
equation. Care should be taken to see that the tracer is not absorbed by the sediment, channel boundary
and vegetation. It should not evaporated easily, should be non toxic and should be detectable even in
small quantities and be relatively inexpensive. The method is particularly recommended for small
turbulent mountainous streams and it is also used to check calibration of stage discharge curves
obtained by velocity area method.
Similarly, the electromagnetic flow meter is used to measure flows in tidal streams/channels where is
fluctuation in quantity and direction of flow. The minimum detectable velocity in this case is
10
Ultrasonic method of velocity measurement of flow uses two transducers fixed at two banks of the
river or channel, receive and send ultrasonic signals. The time taken from one end of the bank to the
other is different for the left and right bank. In one case the component of flow velocity in the
direction of the sound waves is added to the velocity of sound, while in case of the other bank the flow
velocity component is subtracted. The difference in the two velocity components since it can be
measured, and the width of the stream is known, the velocity of flow can be determined. This method
is recommended for unstable cross sections, which have fluctuating weed growth sections, high
suspended solids in flow and there is rapid change in magnitude and direction of flow. The systems are
used for channel widths of upto 500m.
Measuring stream flow using weirs, this forms a part of indirect measurement of flow in open
channels.
The field measurements involve only measurement of depth at specified locations. There exists a
predetermined relationship between discharge and depth. The two most common types of weirs are
rectangular weir and V notch type weir. Typically, a weir is a small wall constructed across the width
of the stream to create an obstruction to flow to measure discharge. The wall can be made of concrete
or thin steel plate as well, the material should be erosion resistant.
Fig. 6: Weirs
11
12
Measurement of Rainfall
Rainfall is measured with the help of rain gauges, it is sometimes called a pluviometer as well.
It is used by hydrologists and meteorologists to measure depth of rainfall over a given period (usually
24 hours). The Symons non-recording type of gauge is one such rain gauge, measures total rainfall
depth. Some instruments are used to measure rainfall on hourly basis as well, also called recording
type of rain gauge (tipping bucket type, which tips after the cylinder or bucket is full). The
measurement is in terms of depth of rainfall (mm or cm), the tipping bucket type measures intensity of
rainfall (mm/hr, cm/hr).
13
Summary
Measurement of discharge using velocity area method gives an estimate of stream velocity at various
points along the cross section however, the assumption is that the cross section remains constant.
While in case of weirs, though they may be more reliable in terms of channel section or site
consistency (parameters not changing with time) but since the formulae are empirically derived using
the coefficient of discharge, the variability may arise due to these constants.
So, the selection of instrumentation depends on the purpose of measurement, desired accuracy,
range of discharge measurement to be undertaken, operation and, maintenance standards desired, life
of the instrument, impact of instrumentation on the surrounding environment, ability to adapt to local
site conditions, user friendly devices are preferred. In conclusion we may say that there is no
instrument which can measure both large and small flows with equal accuracy. So, the range of
measurement required is very important to determine, also the accuracy desired (mostly it is in the
range of 3-5%).Typically broad crested weirs, are used for measuring large flows while V notch
triangular notches are used for measuring small flows. In case of weirs large drop in head is essential
for accurate measurement but in case of relatively flat slope gradient like in irrigation channels it is a
challenge. They are still preferred as they are relatively inexpensive, however, sophisticated flow
meters require very little head difference, though they may be expensive. Similarly, sophisticated
instruments cannot sustain contaminants in flow, acidity or alkalinity and may become inoperative
over time. Measurement of discharge is extremely important in hydraulics and hydrologic studies so
World Meteorology Organization recommends a minimum number of hygrometry stations in every
country depending on the geographical locations. An assessment of water flow helps to accurately
determine the working of the water system in an area.
15
Bos, M.G., (ed.) (1989), Discharge Measurement Structures, third revised edition, International
Institute for Land Reclamation and Improvement, Publication No. 20, Wageningen, The
Netherlands.
Fetter, C.W. (2001), Applied Hydrogeology. 4th ed. New Jersey: Prentice Hall.
Subramanya K.(2008), Engineering Hydrology, third edition, Tata McGraw Hill Publishing Co. ,
New Delhi, India
Subramanya K. (1997), Flow in open channels, second edition, Tata McGraw Hill Publishing Co,
New Delhi, India.
Weight, W.D. and Sonderegger, J.L. (2001), Manual of Applied Field Hydrology. New York:
McGraw Hill Publishing Co
16