1.Introduction 4.

Installation
The series of product is a new generation of multi-functional standalone access control. It adopts Remove the back cover from the keypad using the supplied special screw driver
new ARM core 32-bit microprocessor design, which is powerful, stable and reliable. It contains Drill 2 holes on the wall for the self-tapping screws and hole for the cable
reader mode and standalone access control mode etc.. It’s widely applied to different occasions, Put the supplied rubber bungs to into the two holes
such as office, residential communities, villa etc.. Fix the back cover firmly on the wall with 2 self-tapping screws
Thread the cable through the cable hole
Attach the keypad to the back cover. (as following illustration)

2.Features
Feature Specification

Read 125KHz EM Card and HID Card (Optional)


Card Type
Read 13.56MHz Mifare card and CPU card (Optional)

Keypad Characteristic Operate by infrared remote

Output Way Contain reader mode, the transmission format could be adjusted by users.

Access Way Support multi access ways: Card+Fingerprint, multi cards or multi fingerprints

Admin Card/Fingerprint Support admin card/admin fingerprint

User Capacity 10,000 card users and 300 fingerprint users


5.Wiring
Unlocking Signal Relay NO/NC/COM output
No. Color Marks Description
1 Green D0 Wiegand input (Wiegand output as reader mode)

2 White D1 Wiegand input (Wiegand output as reader mode)

3.Technical Specifications 3 Grey ALARM Alarm signal MOS tube drain output end (optional)

4 Yellow OPEN/ BEEP Exit button input end (Beeper input as reader mode)
Operating Voltage: DC 12-24V Standby Current: ≤ 35mA
5 Brown D_IN/ LED Door contact switch input end (LED input as reader mode) (optional)
Operating Current: ≤100mA Operating Temperature: -20℃~60℃
6 Red +12V Positive power supply
Operating Humidity: 0%~95% Electric lock signal relay contact current ≤1A
7 Black GND Negative power supply
Alarm signal MOS tube output current: ≤1A Unlocking time: 0~300s adjustable
8 Blue NO Relay NO end

9 Purple COM Relay COM end

10 Orange NC Relay NC end

1 2
6.Diagram 6.2 Special Power Supply

6.1 Common Power Supply

D0 Green
Green
D1 White
White
OPEN Yellow Electric control lock
Yellow
Exit button
Exit button
D_IN Brown Brown
Door contact

Special power supply


Door contact Magnetic lock
COM Purple Purple

Black Black
GND

Grey
ALARM Grey
Alarm Alarm
Red
NC Orange Magnetic lock
Blue
+12V Red
Orange

NO Blue

Note: The door contact and alarm function are optional Note: The door contact and alarm function are optional

3 4
6.3 Reader Mode 7.Sound and Light Indication
Operation Status Light indicator Buzzer
Stand by Red
Operation successful Green Beep—
Operation failed Beep-Beep-Beep
Admin card enter programming Beep-Beep
Admin card exit programming Beep—
Press digital key Beep
Green
Press * key Beep—
Read card under fingerprint + code mode Red indicator flash slowly
White
On process of reading multi user card Red indicator flash slowly
Enter programming mode Red indicator flash slowly
Grey
Enter setting status Orange
Unlocking Green
Yellow
Buzzer alarm Red indicator flash quickly Alarm

Brown
8.Admin Menu
Red 8.1 Standalone Mode Settings

Device Management
Black Enter Default
programming Menu Operation steps Description value
Access controller 0 New admin code # new admin
Blue code # Change admin code 999999

10001# Read card / Input a Set admin add card or admin add
fingerprint twice * fingerprint
Purple Press * 1 10002# Read card / Input a Set admin delete card or admin
Admin code # fingerprint twice * delete fingerprint
(Default Delete admin add card or admin
10001# *
Orange admin code is add fingerprint
2
"999999") Delete admin delete card or admin
10002# * delete fingerprint
11 # Standalone access control mode
3 12 # Relay toggle mode
11
13 # Reader mode
( 26-58 ) # Wiegand 26-58 bits output
8 8# WIFI matching Optional

5 6
Add and Delete Users Advanced Settings
Enter Default
programming Menu Operation steps Description
value Enter Menu Operation steps Description Default
programming value
Read card / Input a Add card users or fingerprint
fingerprint twice... * users continuously Door opening time range: 0-300S
4 (0-300) # 5
Press 8 or 10 digits card 0 equals to 50mS
Add card users by card number
number # … * “…” means (0-99) # Alarming time range: 0-99 min.
1 5 0
Press ID number # Read repeating the
Add card users or fingerprint previous
card / Input a fingerprint users by specific ID number Read user card,
twice … * operation,
Press * Press * key input the first
Admin code # fingerprint twice, Match fingerprints to a card
Press ID number # Press 8 Add card users by specific ID to exit. 6 (Maximum 2 fingerprints)
(Default or 10 digits card number # input the second
number and card number
admin code is …* fingerprint
"999999") twice...*
Delete users

Read card / Input a Delete card users by reading


“…” means Press ID number
fingerprint once … * card / Delete fingerprint users
by inputting fingerprint repeating the # press 8
Press * or 10 digits card
previous Add conductive number card
Press 8 or 10 digits card Delete card users by card number operation, Admin code # 7 number #
2 number #… * (Default input card
Press * key
Press ID number # … * Delete users by ID number to exit. admin code is quantity #
"999999")
0000# Delete ALL users
0# Normal working mode

The external alarm and built-in buzzer


1# will work if wrong operations are over 5
times. 0
Access Ways
The device will be locked out for 10 min
Enter Menu Operation Description Default 2# if wrong operations are over 5 times.
programming steps value 8

Press * 3# Disable light indicator


0# Entry by card or fingerprint 4
Admin code #
4# Enable light indicator
(Default 3 1# Entry by card + fingerprint 0
admin code is 5# Disable buzzer
"999999") 2-10 # Entry by multi-card / multi-fingerprint 6
6# Enable buzzer

7 8
8.2 Reader Mode Settings 9.2 Delete Users
Read admin delete card / Input admin delete fingerprint , Read the 1st user card / Input the 1st
Enter Default
programming Menu Operation steps Description fingerprint twice Read the 2nd user card / input the 2nd fingerprint once …, Read admin delete card
value

New admin code # Repeat Note The admin delete card / admin delete fingerprint is used to delete card / fingerprint users
0 new admin code # Change admin code 999999 continuously and quickly. When you read the admin delete card / admin delete fingerprint at the
first time, you will hear short "BEEP" sounds twice and the indicator light turns orange, it means
10001# Read card / Input Set admin add card or you have entered into delete user programming, when you read the admin delete card / admin
a fingerprint twice * admin add fingerprint delete fingerprint at the second time, you will hear long "BEEP" sound once, the indicator light
1 turns red, it means you have exited the delete user programming.
10002# Read card Set admin delete card or
/ Input a fingerprint twice * admin delete fingerprint
10. Other Operation
Press * 10.1 Remove Alarm
Admin code # Delete admin add card or
10001# * admin add fingerprint
(Default Read valid card or Input valid fingerprint or Press admin code#
2
admin code is
Delete admin delete card or Note When the alarm is activated, users can remove the alarm by reading a valid card or
"999999") 10002# * admin delete fingerprint inputting valid fingerprint or pressing valid admin code.

Add fingerprint users 10.2 Reset to Factory Default


Input a fingerprint twice... * continuously
1 “…” means Users can reset to the factory default when the admin code is forgotten, or the default settings
Press ID number # Input a Add fingerprint users by repeating the have been modified disorderedly, operations as below:
fingerprint twice … * specific ID number previous Power off, press and hold the exit button continuously, power on, release the exit button until
operation,
hearing beep sound twice, the admin code has been reset to 999999, factory default settings
Input a fingerprint once... * Delete fingerprint users Press * key
2 to exit. are successful.
0000 # Delete ALL users
Note: Registered user data won’t be deleted when reset to factory default.
3 (26-58) # Wiegand 26-58 bits output 26
5 (0-99) # Alarming time range: 0-99 min 0
9 (0-255) # Device number 0

9.Admin Operation
9.1 Add Users
Read admin add card / Input admin add fingerprint , Read the 1st user card / Input the 1st fingerprint twice

Read the 2nd user card / Input the 2nd fingerprint twice …, Read admin add card / Input admin add fingerprint

Note The admin add card / admin add fingerprint is used to add card / fingerprint users
continuously and quickly. When you read the admin add card / input the admin add fingerprint
at the first time, you will hear short "BEEP" sounds twice and the indicator light turns orange, it
means you have entered into add user programming, when you read the admin add card / input
the admin add fingerprint at the second time, you will hear long "BEEP" sound once and the
indicator light turns red, it means you have exited the add user programming.

9 10