COMPRESSOR TECHNICAL DATA

COMPRESSOR DEFINITION
Designation EM 3Y60HLP
Nominal Voltage/Frequency 115-127 V 60 Hz
Engineering Number 513301619
A - APPLICATION / LIMIT WORKING CONDITIONS
1 Type Hermetic reciprocating compressor
2 Refrigerant R-134a
3 Nominal voltage and frequency 115-127 / 60 [ V / Hz ]
4 Application type Low Back Pressure
4.1 Evaporating temperature range -35°C to -10°C (-31°F to 14°F)
5 Motor type RSCR
6 Starting torque LST - Low Starting Torque
7 Expantion device Capillary tube
8 Compressor cooling Operating voltage range
50 Hz 60 Hz
8.1 LBP (32ºC Ambient temperature) Static - 103 to 140 V
8.2 LBP (43ºC Ambient temperature) Static - 103 to 140 V
8.3 HBP (32ºC Ambient temperature) - - -
8.4 HBP (43ºC Ambient temperature) - - -
9 Maximum condensing temperature
9.1 Operating 14.2 [kgf/cm²] (202 psig) / ºC - ºF
9.2 Peak 15.9 [kgf/cm²] (226 psig) / ºC - ºF
10 Maximum winding temperature 130 [ °C ]
B - MECHANICAL DATA
1 Commercial designation 1/4 [hp]
2 Displacement 5.19 [cm³] (0.317 cu.in)
2.1 Bore [mm] 21.000
2.2 Stroke [mm] 15.000
3 Lubricant charge 150 [ml] (5.07 fl.oz.)
3.1 Lubricants approved
3.2 Lubricants type/viscosity ESTER / ISO10
4 Weight (with oil charge) 7.3 [kg] (16.09 lb.)
5 Nitrogen charge 0.2 to 0.3 [kgf/cm²] (2.84 to 4.27 psig)
C - ELECTRICAL DATA
1 Nominal Voltage/Frequency/Number of Phases 115-127 V 60 Hz 1 ~ (Single phase)
2 Starting device type PTC
2.1 Starting device 8EA14B3/8EA14C3/QPS2-A4R7MD3
3 Start capacitor - [µF(VAC minimum)]
4 Run capacitor 12(180)/15(180) [µF(VAC minimum)]
5 Motor protection 4TM427KFBYY-53
6 Start winding resistance 6.41 [W at 25ºC (77ºF)] +/- 8%
7 Run winding resistance 5.16 [W at 25ºC (77ºF)] +/- 8%
8 LRA - Locked rotor amperage (60 Hz) 12.97 [A] - Measured according to UL 984
9 FLA - Full load amperage L/MBP (60 Hz) 1.70 [A] - Measured according to UL 984
10 FLA - Full Load Amperage HBP (60 Hz) 2.42 [A] - Measured according to UL 984
11 Approval boards certification UL

UPDATE: 13AUG2015 513301619


COMPRESSOR TECHNICAL DATA

D - PERFORMANCE - CHECK POINT DATA

TEST CONDITIONS: ASHRAELBP32 Evaporating temperature -23.3°C (-9.94°F)


@115V60Hz Static (Condensing temperature 54.4°C (129.92°F))
Input power Electric Mass flow Efficiency EER & COP
Cooling capacity (Qe) (We) current rate
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
[Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
648 163 190 112 1.05 3.68 5.79 1.46 1.70

E - PERFORMANCE - CURVES

TEST CONDITIONS: ASHRAE32 (Condensing temperature 35ºC (+95ºF) )


@115V60Hz Static
Input power Electric current Mass flow Efficiency EER & COP
Evaporating Cooling capacity (Qe)
(We) rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 373 94 109 73 0.76 2.11 5.15 1.30 1.51
-30 (-22) 500 126 146 83 0.84 2.83 6.04 1.52 1.77
-25 (-13) 654 165 192 94 0.92 3.71 6.99 1.76 2.05
-20 (- 4) 843 212 247 105 1.01 4.80 8.04 2.03 2.36
-15 (+ 5) 1075 271 315 116 1.11 6.14 9.20 2.32 2.70
-10 (+14) 1357 342 398 129 1.22 7.78 10.50 2.65 3.08

TEST CONDITIONS: ASHRAE32 (Condensing temperature 45ºC (+113ºF) )


@115V60Hz Static
Input power Electric current Mass flow Efficiency EER & COP
Evaporating Cooling capacity (Qe)
(We) rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 339 85 99 74 0.77 1.92 4.55 1.15 1.33
-30 (-22) 471 119 138 88 0.87 2.67 5.38 1.36 1.58
-25 (-13) 626 158 184 101 0.98 3.56 6.23 1.57 1.83
-20 (- 4) 813 205 238 115 1.09 4.63 7.12 1.79 2.09
-15 (+ 5) 1038 262 304 128 1.21 5.92 8.08 2.04 2.37
-10 (+14) 1308 330 383 143 1.34 7.50 9.12 2.30 2.67

TEST CONDITIONS: ASHRAE32 (Condensing temperature 55ºC (+131ºF) )


@115V60Hz Static
Input power Electric current Mass flow Efficiency EER & COP
Evaporating Cooling capacity (Qe)
(We) rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 271 68 79 70 0.74 1.53 3.85 0.97 1.13
-30 (-22) 413 104 121 87 0.87 2.34 4.70 1.18 1.38
-25 (-13) 574 145 168 104 1.01 3.26 5.52 1.39 1.62
-20 (- 4) 762 192 223 121 1.15 4.34 6.32 1.59 1.85
-15 (+ 5) 984 248 288 138 1.29 5.62 7.15 1.80 2.10
-10 (+14) 1248 315 366 156 1.44 7.15 8.02 2.02 2.35

UPDATE: 13AUG2015 513301619


COMPRESSOR TECHNICAL DATA

E - PERFORMANCE - CURVES

TEST CONDITIONS: ASHRAE32 (Condensing temperature 65ºC (+149ºF) )


@115V60Hz Static
Input power Electric current Mass flow Efficiency EER & COP
Evaporating Cooling capacity (Qe)
(We) rate
temperature
+/- 5% +/- 5% +/- 5% +/- 5% +/- 7%
°C (°F) [Btu/h] [kcal/h] [W] [W] [A] [kg/h] [Btu/Wh] [kcal/Wh] [W/W]
-35 (-31) 169 43 50 58 0.66 0.96 2.94 0.74 0.86
-30 (-22) 325 82 95 81 0.83 1.85 3.88 0.98 1.14
-25 (-13) 497 125 146 103 1.00 2.82 4.73 1.19 1.39
-20 (- 4) 691 174 202 125 1.18 3.93 5.53 1.39 1.62
-15 (+ 5) 915 231 268 146 1.36 5.22 6.29 1.59 1.84
-10 (+14) 1176 296 345 168 1.54 6.74 7.05 1.78 2.07

UPDATE: 13AUG2015 513301619


COMPRESSOR TECHNICAL DATA

F - EXTERNAL CHARACTERISTICS
1 Base plate Universal
2 Tray holder No
3 Connectors
3.1 SUCTION 6.5 +0.12/-0.08 [mm] (0.256" +0.005"/-0.003")
3.1.1 Material Copper
3.1.2 Shape Slanted 42º up + 45° to Back
3.2 DISCHARGE 4.94 +0.08/-0.08 [mm] (0.194" +0.003"/-0.003")
3.2.1 Material Copper
3.2.2 Shape Slanted 30° up + 24° to Back
3.3 PROCESS 6.5 +0.12/-0.08 [mm] (0.256" +0.005"/-0.003")
3.3.1 Material Copper
3.3.2 Shape Slanted 45° up + 45° to Back
3.4 Oil cooler (Copper) No [mm]
3.5 Connector sealing Rubber Plugs

UPDATE: 13AUG2015 513301619