G SERIES ROTARY GAS FLOWMETER

APPROVAL
CE MARKING CN MARKING
JJG633
EN 12480
JB/T 7385
EN 60079
GB/T 3836.1-2021
EN IEC 60079
GB/T 3836.4-2021

PRODUCT FEATURES
1 High-strength surface treatment of the impellers and body, extremely strong anti-stress characteristics, non-contact
rotation, good oil lubrication, in order to avoid the impellers from jamming.
2 The wide measuring rangeability is up to 1:300.
3 High precision and high reliability, the base meter accuracy reaches level 1.0.
4 The minimum starting flow rate can be as low as 0.016m³/h.
5 The pressure loss for different sizes & specifications is between 0.1kPa and 0.78kPa.
6 Non-linear correction function: 8 sections of non-linear correction can be performed according to the metering error
curve of the flow meter, thereby improving the metering accuracy and expanding the rangeability.
7 It can detect live temperature and pressure of the gas flow, for volume compensation and compressibility factor
correction, in order to measure the standard flowrate and standard total volume of the gas.
8 Bluetooth set-up function: using the mobile phone APP software to program the meter set-up by Bluetooth, the
meter program set-up will be automatically recorded.
9 The upper and lower limit of alarms can be set for the flowrate, temperature, pressure, battery power and other
parameters, as well as the anti-damage, anti-magnetic, anti-dismantling alarm functions.
10 Remote upgrade function: by full network NB or 4G wireless communication, supports automatic switching between
long connection of main power and short connection of lithium battery, and supports remote upgrade function.
11 Optional built-in IC card control function, combined with remote function, can realize IC card prepayment, remote
recharge, price adjustment, valve control and other functions.
12 Adopt dynamic password design to prevent data from being modified arbitrarily and automatic recording of all key
data modification.

ACCESSORY FEATURES
1 Mechanical counter——It has permanent lubrication performance, long service life, no maintenance, and can be
used as a backup data reference.
2 The smart volume corrector has strong anti-interference and high reliability.
3 The low flow compensation to ensure accurate measurement of the flowrate below 10% FS.
4 All external ports of the circuit board adopt photoelectric isolation design to ensure the normal operation of the
volume corrector around the clock.
5 Volume corrector has different option of pulse output, as well as the RS485 communication port.
TECHNICAL SPECIFICATION

MODEL DIN FLANGE START FLOW FLOW RANGE MAXIMUM WEIGHT


RANGEABILITY PRESSURE LOSS CONNECTION
SIZE (mm) (m3/h) (m3/h) (kPa) (kg)

G6 DN20 0.016 0.16~10 63:1 0.2 THREAD、FLANGE 3

G6 DN25 0.016 0.16~10 63:1 0.2 THREAD、FLANGE 3

G10 DN25 0.016 0.16~16 100:1 0.2 THREAD、FLANGE 3

G16 DN25 0.02 0.25~25 100:1 0.25 THREAD、FLANGE 4

G25 DN25 0.02 0.4~40 100:1 0.25 THREAD、FLANGE 6

G16 DN32 0.02 0.25~25 100:1 0.2 THREAD、FLANGE 4

G25 DN32 0.02 0.4~40 100:1 0.2 THREAD、FLANGE 4

G10 DN40 0.03 0.32~16 50:1 0.2 FLANGE 10

G16 DN40 0.03 0.50~25 50:1 0.2 FLANGE 10

G25 DN40 0.03 0.50~40 80:1 0.25 FLANGE 11

G40 DN40 0.04 0.65~65 100:1 0.25 FLANGE 14

G16 DN50 0.03 0.50~25 50:1 0.1 FLANGE 10

G25 DN50 0.03 0.50~40 80:1 0.2 FLANGE 12

G40 DN50 0.04 0.65~65 100:1 0.2 FLANGE 14

G65 DN50 0.04 0.65~100 153:1 0.3 FLANGE 16

G100 DN80 0.04 0.80~160 200:1 0.4 FLANGE 19

G160 DN80 0.06 1.25~250 200:1 0.5 FLANGE 30

G160 DN100 0.06 1.25~250 200:1 0.5 FLANGE 30

G250 DN100 0.06 2~400 200:1 0.53 FLANGE 37

G400 DN100 0.10 3.25~650 200:1 0.75 FLANGE 45

G400 DN150 0.40 3.5~700 200:1 0.76 FLANGE 97

G650 DN150/DN200 0.50 5~1000 200:1 0.77 FLANGE 118

G1000 DN150/DN200 0.60 8~1600 200:1 0.77 FLANGE 118

NOTE: 1、The nominal pressure is PN1.6MPa, pressure sensor is 0.5MPa, special requirements please contact us for special requirement.
2、The flow range is indicated by the smart flowmeter.

FLOWMETEK (SHANG HAI) AUTOMATION & INSTRUMENT CO.,LTD


ADD: NO. 2199, GUANGTAI ROAD, JINHUI TOWN, FENGXIAN DISTRICT, SHANGHAI
WEBSITE: WWW.FLOWMETEK.COM.CN
MTTM SERIES TURBINE FLOWMETER

APPROVAL
CE MARKING CN MARKING
JJG 1037
EN 12261
GB/T 18940
EN IEC 60079
GB/T 3836.1-2021
EN 60079
GB/T 3836.4-2021

PRODUCT PRODUCT FEATURES


OVERVIEW
1 The unique rectification structure can maintain the reliability of measurement even when
the installation conditions are not ideal and the gas flow rate changes relatively greatly.
MTTM 8 series turbine 2 The double dustproof structure design can effectively prevent impurities in the gas from
flowmeter is a new type of entering the bearing and causing rapid wear and jamming.
precision flowmeter inde- 3 The meter head can be rotated 340°, which is easy to install and use.
pendently developed by 4 The straight pipe section requirement is low and the anti-flow disturbance ability is strong.
Flowmetek(Shanghai) 5 The meter housing protection grade is IP67.
Automation Co., Ltd., which 6 It can detect live temperature and pressure for volume compensation and compressibility
integrates flow, tempera- factor correction, in order to measure the standard flowrate and standard total volume of
ture and pressure detection the gas.
functions and can automat- 7 Adopting new sensor, low starting flow, small pressure loss, good anti-vibration and
ically correct and compen- anti-pulsation performance; not easy to corrode, stable and reliable, long service life.
sate temperature, pressure 8 Adopting new microprocessor and high-performance integrated chip, high calculation
and compressibility factor. accuracy, powerful working function and superior performance.
It is a metering instrument 9 Advanced micro-power consumption technology for overall low power consumption, it can
for gas measurement in be powered by internal battery as well as external power supply.
industries such as petro- 10 The low flow compensation is to ensure accurate measurement of the flowrate below 10% FS.
leum, chemical, electric 11 Non-linear correction: 8 sections of non-linear correction can be performed according to
power, metallurgy, industri- the metering error curve of the flow meter, thereby improving the metering accuracy and
al boilers, and urban gas expanding the rangeability.
measurement. 12 Large-screen LCD display, clear and intuitive, easy to read.
13 Variety of pulse output modes can be set and selected, as well as the calibration pulse value.
14 Large-capacity data storage and query functions, the data recording interval timing can be set.
15 RS485 interface is available for data collector to perform automatic meter reading and
management system through network, highly automated and convenient for users to manage.
16 Adopt dynamic password design to prevent data from being modified arbitrarily and automatic
recording of all key data modification.
TECHNICAL SPECIFICATION

DIN FLANGE START FLOW FLOW RANGE MAXIMUM


MODEL SIZE PRESSURE LOSS WEIGHT
(mm) (m3/h) (m3/h) (kPa) (kg)

MTTM-25A(Z) G16 ≤0.8 2.5~25 0.6


DN25 5
MTTM-25B(Z) G25 ≤1.3 4~40 1.1

MTTM-50A(Z) G40 ≤1.3 5~65 0.6


MTTM-50B(Z) G65 DN50 ≤1.6 8~100 0.9 7
MTTM-50C(Z) G100 ≤2.4 10~160 2.0

MTTM-80A(Z) G100 ≤2.4 8~160 0.7


MTTM-80B(Z) G160 DN80 ≤3.0 13~250 1.2 12
MTTM-80C(Z) G250 ≤5.0 20~400 2.2
MTTM-100A(Z) G160 ≤3.2 13~250 0.8
MTTM-100B(Z) G250 DN100 ≤4.2 20~400 1.3 13
MTTM-100C(Z) G400 ≤6.7 32~650 2.5

MTTM-150A(Z) G400 ≤7.8 32~650 0.7


MTTM-150B(Z) G650 DN150 ≤10.0 50~1000 1.0 23
MTTM-150C(Z) G1000 ≤12.0 80~1600 2.3
MTTM-200A(Z) G650 ≤12.0 50~1000 0.7
MTTM-200B(Z) G1000 DN200 ≤16.0 80~1600 0.9 40
MTTM-200C(Z) G1600 ≤20.0 130~2500 1.7

MTTM-250A(Z) G1000 ≤20.0 80~1600 0.6


MTTM-250B(Z) G1600 DN250 ≤22.0 130~2500 1.0 120
MTTM-250C(Z) G2500 ≤25.0 200~4000 2.0

MTTM-300A(Z) G1600 ≤22.0 130~2500 0.7


MTTM-300B(Z) G2500 DN300 ≤25.0 200~4000 1.0 172
MTTM-300C(Z) G4000 ≤35.0 320~6500 2.0

NOTE: 1、The nominal pressure is PN1.6MPa, pressure sensor is 0.5MPa, special requirements please contact us for special requirement.
2、All meter accurancy class reaches level 1.5 or 1.0.
3、Model with (Z) is smart meter with EVC.

FLOWMETEK (SHANG HAI) AUTOMATION & INSTRUMENT CO.,LTD


ADD: NO. 2199, GUANGTAI ROAD, JINHUI TOWN, FENGXIAN DISTRICT, SHANGHAI
WEBSITE: WWW.FLOWMETEK.COM.CN
MG SERIES ULTRASONIC GAS METER

MG series ultrasonic gas meter is a velocity type full


electronic meter. Different from traditional diaphragm
gas meter, it can achieve accurate measurement of
wide flow range through electronic correction technol-
ogy. The product uses imported high-sensitivity ultrason-
ic sensor to measure gas flow rate, converts ultrasonic
signal into electrical signal, and intelligent control
module converts the received electrical signal into
digital signal. The core metering algorithm measures
the gas flow rate of the measured gas and displays it
as volume.

PRODUCT FEATURES

1 The ultrasonic technology is adopted, which has high precision, long service life and no special maintenance is
required for long-term operation.
2 Integrates CPU/IC card operation, flow measurement, automatic temperature and pressure compensation, com-
pressibility factor correction calculation and flow control, all in one unit with compact structure and high reliability.
3 The minimum flow rate can be as low as 0.016m³/h and can provide accurate measurement, with a wide rangeabili-
ty of up to 1:375.
4 No mechanical moving parts, no wear and tear, and little pressure loss.
The detectable starting flow rate can reach 0.004m³/h.
5 The internal power supply adopts the best mode of metering battery and communication battery for power supply
respectively, which can also be switched automatically according to needs. The whole meter has low power
consumption and the internal battery can be used for more than 10 years (communication once a day).
6 According to user requirements, various cards such as user card, set-up card, acquisition card, clear card, valve
opening card, etc. can be issued to facilitate usage and management.
7 The card holder can prevent metal sheet attacks and strong magnetic interference.
8 It has alarm and cut-off functions for backflow, abnormal flow, abnormal temperature, water inflow, constant flow,
minor leakage, anti-dismantling, etc.
9 Through the wireless network and the meter reading system, it can be connected to the network for full-automatic
network meter reading and remote meter switch valve control, recharge, price adjustment and meter parameter
setting.
10 Using the public network, users can choose our network service platform or other network service platforms for
remote meter reading, and the daily gas consumption is stored in the cloud data server. The network structure is
simple, the meter side communicates directly with the background server side, and supports the use of NB-IoT
wireless modules.
11 Remote real-time monitoring: when low power, low volume, meter dead, sampling failure, or leakage alarm (external
link leakage alarm) occurs, the alarm information is uploaded to the background application platform in real time.
12 Remote maintenance: prepaid meters can implement tiered gas prices through the meter end, and postpaid meters
can implement tiered gas price charging through the background software.
TECHNICAL SPECIFICATION

MODEL MG1.6 MG2.5 MG4 MG6 MG10 MG10W MG16 MG16W MG25 MG40 MG65

Qmax(m3/h) 2.5 4 6 10 16 16 25 25 40 65 100

Qmin(m3/h) 0.016 0.025 0.04 0.06 0.1 0.06 0.16 0.1 0.25 0.4 0.65

Qt(m3/h) 0.25 0.4 0.6 1 1.6 1 2.5 1.6 4 6.5 10

Rangeability 1:160 1:160 1:160 1:160 1:160 1:250 1:160 1:250 1:160 1:160 1:160

Weight 1.65kg 2.3kg 4.3kg

Body Material Carbon Steel Aluminium

Light Pulse(limp) 1L 1L/5L 5L/10L 10L/20L

Electricalpulse(limp) 0.001L 0.01L 0.1L


≤300Pa ≤400Pa
Pressure Loss ≤250Pa(with control valve) ≤375Pa(with control valve) (without control valve) (without control valve)

Base Temperature 20℃

Base Pressure 101.325kPa

Battery ER34615H/3.6V

Accuracy Class 1.5

Indication qmin≤q<qt ±3%


error qt≤q≤qmax ±1.5%
Measurement
Resolution 0.1L
Relative
Humidity ≤95% H
Atmospheric
Pressure 86kPa~106kPa
Working
Temperature -10℃~40℃

Class of protection IP65

Explosion proof Ex ib IIB T3 Gb

Communication NB-IoT 4G/NB

Battery Life Built-in lithium battery ≥10 years (communication once a day); Alkaline battery ≥1 year

Medium Air、Natural gas

FLOWMETEK (SHANG HAI) AUTOMATION & INSTRUMENT CO.,LTD


ADD: NO. 2199, GUANGTAI ROAD, JINHUI TOWN, FENGXIAN DISTRICT, SHANGHAI
WEBSITE: WWW.FLOWMETEK.COM.CN
MTUM_T SERIES ULTRASONIC FLOW METER

PRODUCT OVERVIEW ULTRASONIC BASE METER PART

MTUM_T series gas ultrasonic flowmeter 1 Two to three-section four-channel layout, with eddy current and asym-
is a new type of gas ultrasonic flowmeter metric flow detection and compensation functions
based on ultrasonic time difference 2 With multiple self-diagnosis and self-correction functions.
method to measure flow velocity. 3 Independent metering core structure design is easy to maintain and can
improve product reliability and service life.
The flow meter adopts a four-channel 4 Wide rangeability, ≥100:1 (DN25~DN40) and 160:1 (DN50~DN200).
design, which can effectively reduce the 5 The starting flow rate is low, and the lower limit of the measurable flow
influence of vortex and asymmetric flow, rate is no more than 15mm/s.
and improve the measurement accuracy 6 With zero point self-tracking function, it can effectively eliminate zero
and reliability. The product integrates flow point drift.
measurement and volume correction, and 7 Four-channel redundant design, even if some channels fail, the mea-
can directly measure the volume flow, surement can still be basically accurate and the reliability is high.
temperature, pressure under gas mea- 8 Straight-through measuring tube design, zero pressure loss.
surement conditions (referred to as "work-
ing conditions"), volume flow under refer-
ence conditions (referred to as "standard
conditions") and total volume. The Internet
CORRECTOR PART
of Things communication and system 1 The volume corrector and ultrasonic base meter use UART commu-
platform prepaid settlement functions can nication mode to ensure that the base meter and the corrector data
also be added as needed. It is an ideal are completely synchronized. At the same time, the main status diag-
instrument for urban gas trade measure- nostic information of the base meter can be collected and alarms can
ment and industrial gas measurement in be displayed.
petrochemical, metallurgical, electric 2 The volume corrector adopts a fully digital design, with high conver-
power and other industries. sion accuracy and perfect data management capabilities
3 The IoT communication module and the corrector adopt a unique
This product complies with the China structural design, and the IoT module design is standardized, 2G,
4G, and NB can be directly interchanged and upgraded.
national standard JJG1030-2007 "Ultra-
4 Adopts a variety of electromagnetic compatibility design technolo-
sonic Flowmeter Calibration Regulations".
gies and has strong anti-interference ability.
TECHNICAL SPECIFICATION

DN FLANGE FLOW RANGE START FLOW WORKING PRESSURE


(MPa.a)
MODEL
mm m3/h m3/h /NOMINAL PRESSURE
(MPa.g)

MTUMT-025 25 0.4~40 0.10

MTUMT-040 32 0.65~65 0.12

MTUMT-065 40 1.0~100 0.14

MTUMT-100 50 1.0~160 0.20


1.6/1.6

MTUMT-250 80 2.5~400 0.40

MTUMT-400 100 4.0~650 0.65

MTUMT-1000 150 10~1600 1.0

MTUMT-1600 200 16~2500 1.2

FLOWMETEK (SHANG HAI) AUTOMATION & INSTRUMENT CO.,LTD


ADD: NO. 2199, GUANGTAI ROAD, JINHUI TOWN, FENGXIAN DISTRICT, SHANGHAI
WEBSITE: WWW.FLOWMETEK.COM.CN
SMARC-PTZ
INTELLIGENT VOLUME
CORRECTION INSTRUMENT

PRODUCT OVERVIEW
SMARC intelligent volume corrector (hereinafter referred to as the corrector) integrates flow, temperature and pressure
detection functions, automatically compensates for temperature and pressure, and automatically corrects the natural gas
compression factor. This corrector adopts advanced low-power microprocessors, stable and reliable software and hard-
ware design, and advanced patch welding technology. The reliability and stability of the instrument are guaranteed from
design to production. At the same time, we also track the latest domestic and foreign technologies and standards as well
as feedback from end customers to ensure the practicality, advancement and reliability of the product. In addition, SMARC
corrector also has RS-485, (4-20) mA and other signal output modes, which is convenient for communication connection
with any monitoring system. It is an ideal supporting instrument for gas measurement.

PRODUCT FEATURES
Temperature and pressure compensation function: It uses high-precision imported digital temperature and pressure
sensors, and calculates the pressure factor coefficient according to the standard gas state equation based on the set
gas components. It can perform online temperature and pressure compensation correction on the volume and flow of
the gas in and out of the flow meter, and convert it into the flow and volume under standard conditions, thereby realizing
the temperature and pressure compensation function.
Multi-screen display function: standard condition, working condition instantaneous flow and cumulative flow, tempera-
ture, pressure, time, battery power, valve status, consumption amount, total amount, remaining amount/total amount, etc.
Alarm function: The upper and lower limits of the volume corrector's flow, temperature, pressure, battery and other
parameters can be set, and an alarm will be triggered when the limit is exceeded; at the same time, anti-cutter, anti-mag-
netic, and anti-disassembly alarm functions can be set.
Non-linear correction function: The corrector can perform up to 8 sections of non-linear correction according to the
metering error curve of the meter, thereby improving the metering accuracy of the flow meter and expanding the rangeability.
Automatic correction function of compressibilty factor: You can choose standard formulas such as AGA-8, SGERG-88,
AGA-NX19, etc., or to choose the fix compressibility factor correction.
It adopts lightning protection, surge protection, pulse group suppression and other circuit protection designs, and has
powerful anti-interference function.
4G/NB communication module can be embedded, and the working mode of the wireless communication module can be
set and selected by yourself.
It can embed smart IC card to form a prepaid charging system, which is convenient for users to manage charges and
supports remote valve switch control.
Dynamic password design is adopted to prevent data tampering and realize automatic recording of key data modification.
MAIN TECHNICAL PARAMETERS
Conditions of use
a. Ambient temperature: -25°C~+70°C
b.Relative humidity: 5%~95%
c. Atmospheric pressure: 70kPa~106kPa
d. Temperature sensor measurement range: -40°C~+120°C
e. Pressure sensor overload: ≤1.5Pmax (5.0MPa standard and below); ≤1.1Pmax (10.0Mpa standard).
Accuracy level
05: Maximum overall indication error: ±0.5%; Among them, the maximum pressure indication error: ±0.2% (≥
20%Pmax, at -15C ~ +65); Maximum temperature indication error: ±0.5 .
Input signal
a. Pulse signal: high frequency signal (0-5kHz, VPP=3V) or low frequency signal (unit pulse is 0.01m³/0.1m³/1m³/10m³,
VPP=3V);
b. Temperature signal and pressure signal: 12C digital communication interface, 100KHz.
Pulse output
a. uncorrected pulse signal, directly output the uncorrected pulse signal detected by the flow sensor through photoelectric
isolation and amplification, high level ≥ 20V, low level ≤ 1V (24Vd.c. power supply);
b. After the uncorrected pulse is corrected nonlinearly, it is amplified and output through photoelectric isolation. The high
level is ≥20V and the low level is ≤1V (24Vd.c.powered by);
c. The pulse frequency signal is proportional to the volume flow rate under working or standard conditions, and is amplified
and outputted through photoelectric isolation. The high level amplitude is ≥20V, the low level is ≤1V, and the corresponding
flow value of the full range of 2000Hz can be set (24Vd.c. power supply);
d. Calibration pulse signal, matching with IC card valve controller, high level amplitude ≥2.8V, low level amplitude ≤0.2V,
unit pulse represents volume, the setting range is: 0.01m²/0.1m³/1m³/10m³, but when selecting this value, it must be noted
that the calibration pulse signal frequency should be ≤50Hz.

Maximum working pressure Pmax (sensor range upper limit)


0.2, 0.5, 1.0, 2.0, 5.0, 10.0 (MPa, absolute pressure)

Working power supply and power consumption


a. External power supply: 24 (1±15%) Vd.c, ripple ≤±%, suitable for 4mA~20mA output, pulse output, RS485, 4G (NB-IoT)
IoT communication, power consumption ≤2.5W;
b. Internal power supply: 2 sets of batteries are built in. The IoT communication battery can communicate once a day and
can be used for about 3 years. The metering battery can be used for more than 5 years.

RS485 communication
Adopt photoelectric isolation 485 communication module, which can be directly connected to the host computer or second-
ary instrument, baud rate: 9600bps.

4mA-20mA standard current signal


The standard current module adopts photoelectric isolation design, and can select one of the physical quantities of
temperature, pressure, working volume flow, and standard volume flow to output.
a. When the selected physical quantity is temperature, 4mA corresponds to a temperature value of -40; when other phys-
ical quantities are selected, 4mA corresponds to a value of 0;
b. The corresponding value of 20mA can be set;
c. Standard: two-wire system; maximum error ±025%FS.

Operation history data recording function


using large-capacity EEPROM storage chip, recording up to 5 years of hourly records, 3 years of daily records, 10 years of
monthly records and other rabnormal alarm records and parameter modification records.

Explosion-proof mark: Intrinsically safe type


Ex ia IIC T4 Ga.

FLOWMETEK (SHANG HAI) AUTOMATION & INSTRUMENT CO.,LTD


ADD: NO. 2199, GUANGTAI ROAD, JINHUI TOWN, FENGXIAN DISTRICT, SHANGHAI
WEBSITE: WWW.FLOWMETEK.COM.CN
WIRELESS REMOTE TRANSMISSION
DIAPHRAGM GAS METER
(IOT DIAPHRAGM GAS METER)

PRODUCT OVERVIEW PRODUCT FEATURES


Wireless remote transmission
diaphragm gas meter, also
Communication function
known as Internet of Things The gas company management platform uses the telecom operator's
diaphragm gas meter, is a NB-IOT platform to check the user's meter data at regular or real-time
diaphragm gas meter that relies intervals, set parameters, check the meter's operating status and
on the Internet to perform remote battery power in real time, and open or close the gas meter valve in real
measurement, remote communi- time;
cation and remote control of the
gas meter. It can also realize Upload method
functions such as automatic Scheduled data upload (upload according to the time set in the meter)
meter reading, operation status Meter button to upload (press the button for 3 seconds to upload, limit 10
monitoring, online self-service times per day);
recharge and payment, safety
alarm and valve control. It assists Display function
in the formulation of gas opera-
LCD displays the meter's real-time operating status, working mode,
tion and management decisions
valve status, cumulative information, etc.;
through gas consumption analy-
sis, forming an intelligent network Prompt function
metering model.
Alarm prompts the meter to indicate low power and other working condi-
tions;

Protection function
The valve will be automatically closed when the meter is abnormal, and
the internal data will be automatically saved without loss;
Abnormal conditions include: magnetic attack, low power, gas leakage,
large flow, small flow, inversion, and disassembly;
Data storage function
The meter can store 120 days of daily gas consumption and 2 years of monthly gas consumption records;

Supplementary reading function


The staff can use infrared communication on-site with a handheld tablet computer to check the gas meter usage status
(including gas usage, battery status, meter operation status, etc.).

TECHNICAL SPECIFICATION

ARGUMENT VOLUME OF PRESSURE LOSS


NOMINAL FLOW MAXIMUM FLOW MINIMUM FLOW STARTING FLOW
ROTATION
qm3/h qm3/h qm3/h dm3/h
MODEL Vc dm3 WITH VALVE WITHOUT VALVE

YG 1.6-NB01 1.6 2.5 0.016 ≤3 0.7 ≤250Pa ≤200Pa

YG 2.5-NB01 2.5 4.0 0.025 ≤5 1.2 ≤250Pa ≤200Pa

YG 4-NB01 4 6.0 0.04 ≤5 1.2 ≤250Pa ≤200Pa

FLOWMETEK (SHANG HAI) AUTOMATION & INSTRUMENT CO.,LTD


ADD: NO. 2199, GUANGTAI ROAD, JINHUI TOWN, FENGXIAN DISTRICT, SHANGHAI
WEBSITE: WWW.FLOWMETEK.COM.CN