Pump Performance:According to ISO9906-2012,Grade 2B

Pump Performance Datasheet


Customer Quote number
Customer Reference Pump size LF10153G
Item number Stages 1
Service Based on curve number 1
Quantity of pumps Data last saved 2024-12-17
Operating Conditions Liquid
Flow 700 m3/h Liquid type Water
Head(requested) 23 m Additional liquid description
Head(actual) 23 m Solids diameter,max 0 mm
Suction pressure,rated/max Temperature 20 C
NPSH available,rated Ample m Fluid density,rated/max 1000.00 kg/m3
Frequency 50 HZ Viscosity,rated 1.0 cst
Performance Material
Pump speed,rated 1485 rpm Casing Material CI
Impeller diameter,rated 306.8 mm Impeller Material SS
Impeller diameter,maximum 381.0 mm Pressure Data
Impeller diameter,minimum 305.0 mm Flange Rating PN10
Efficiency 82.76 % Maximum working pressure 0.28 MPa
NPSH 4.9 m Maximum allowable working requested 1.00 MPa
- - Maximum allowable suction pressure limit 0.72 MPa
MCSF 288.68 m3/h Casing hydrostatic test pressure 1.50 MPa
Head Maximum,rated diameter 28.8 m
Driver&Power Data
Head rise to shut off 82.63 %
Driver sizing specification 280S
Flow,best eff.Point(BEP) 728.66 m3/h Margin over specification 1.42
Flow ratio(rated/BEP) 96.07 % Service factor
Head ratio(rated/Max Diameter) 50.09 % Power,hydraulic 43.83 kW
Diameter ratio(ratio/max) 80.51 % Power,rated 52.96 kW
Viscous coefficients(CQ/CH/CE) 1.0/1.0/1.0 Power,maximum 54.87 kW
Selection status Acceptable Min recommended driver 75.00 kW

P(kW)
75

60

45

30

15
0
0 180 360 540 720 900 1080 1260 1440 1620 1800

H(m) Eff(%)
60 100

54

48 80

42

36 60

30 381.00mm

24 40

18
306.76mm
12 305.00mm 20

0 0
0 180 360 540 720 900 1080 1260 1440 1620 1800

NPSH(m) Q(m3/h)
9.0
7.2
5.4
3.6
1.8
0.0
0 180 360 540 720 900 1080 1260 1440 1620 1800

Printed from Grundfos Selector [V8.0.2023-12-30] Motor Sizing Method:ISO 5199


1/2
DIMENSIONS
End Suction Pumps

LF10153G Outline Drawing

L X Y Z HM HB HP HL HD HA
2150 352.3 289 327 1132 1870 200 710 601.6 580
HE n HH HR
510 6 24 210

SUCTION FLANGE DIMENSION


DN T n d K D
300 31.8 12 23 400 482.6
DISCHARGE FLANGE DIMENSION
DN T n d K D
250 47.5 12 23 350 444.5

Explanation:
1.Flange drilled to:PN10;
2.Motor:MMG IE3 motor,75kW,4poles,280S;
3.Weight:1210kg;
4.Recommend using DIN 529-A M20x500 foundation bolts.
5.Packaging:Complete package for motor and pump.

Note:All units are in [mm] unless others are stated. 2024-12-17