Agilent U1730C Series Handheld LCR Meters: Take Your Expectations Higher With The Latest LCR Meters
Agilent U1730C Series Handheld LCR Meters: Take Your Expectations Higher With The Latest LCR Meters
Agilent U1730C Series Handheld LCR Meters: Take Your Expectations Higher With The Latest LCR Meters
Agilents U1730C Series handheld LCR meters allow you to measure at frequencies as high as 100 kHza capability typically found only in benchtop meters. Get measurements done faster using the one-touch automatic identification function button which displays component type and more detailed component analysis such as Z, ESR, and DCR. Ideal for testing on the go, these LCR meters operate on a battery that lasts up to 16 hours. With the U1730C Series that is built for your convenience, you can perform quick and basic LCR measurements at an affordable price. Its a good time to retool your expectations in handheld LCR meters.
Features
Key features
20,000 counts resolution 0.2% basic accuracy Wide LCR ranges with three to five selectable test frequencies (up to 100 kHz for U1733C) Auto identification (Ai) automatically determines and displays component type and measurements Detailed component analysis with DCR, ESR, Z, D, Q, and functions Battery life of 16 hours/ AC-powered IR-to-USB connectivity for data logging to PC
Automated identification
With Ai the testing and measuring experience is easy; eliminating unnecessary trial and error timewith just a single push of a button. This unique feature automatically specifies L, C, or R with parallel and series mode, without the need to manually change buttons.
Figure 1. Automate the recording of continuous readings when you hook the U1731C/U1732C/U1733C to a PC
2
Visible and audible tolerance mode for component sorting Secondary display Maximum, Minimum and Average values recording 20,000 counts resolution Ai helps identify L, C, and R components automatically according to level of impedance ESR function for capacitance series resistance analysis Auto calculation of Phase Angle, Dissipation Factor, and Quality Factor To select desired Z, L, C, or R function To enter rolerance range of 1%, 5%, 10%, and 20% Backlight function to ease viewing in subdued lighting (only in U1732C/U1733C) Data Hold function to freeze and save measured values Allows manual or auto ranging to be used interchangeably
To select desired test frequency: U1731C: Up to 1 kHz U1732C: Up to 10 kHz U1733C: Up to 100 kHz To enable DCR measurement (only in U1733C)
Impedance/Resistance
Accuracy = AZ + Offset Range
2
1 1
Resolution 100 Hz
0.0001 0.001 0.01 0.1 0.001 k 0.01 k 0.1 k 0.001 M 0.01 M 0.7% + 50 0.7% + 8 0.2% + 3 0.2% + 3 0.2% + 3 0.5% + 5 0.5% + 5 2.0% + 8 6.0% + 80
U1731C/U1732C/U1733C 120 Hz
0.7% + 50 0.7% + 8 0.2% + 3 0.2% + 3 0.2% + 3 0.5% + 5 0.5% + 5 2.0% + 8 6.0% + 80
U1732C/U1733C 10 kHz
0.7% + 50 0.7% + 8 0.2% + 3 0.2% + 3 0.2% + 3 0.5% + 5 0.7% + 5 5.0% + 8 NA
1 kHz
0.7% + 50 0.7% + 8 0.2% + 3 0.2% + 3 0.2% + 3 0.5% + 5 0.5% + 5 2.0% + 8 6.0% + 80
DCR
0.7% + 50 0.7% + 8 0.2% + 3 0.2% + 3 0.2% + 3 0.5% + 5 0.5% + 5 2.0% + 8 6.0% + 80
20
1. This accuracy for the ranges of 2~ 200 is specified after Math Null which is used to substrate the resistance of test leads and the contact resistance. Notes: a. For the ranges of 20 M and 200 M, the R.H. is specified for < 60% b. Resistance is specified to Q < 10 and D > 0.1, otherwise the accuracy is (AZ + Offset) x 1 + Q2 c. Equivalence Series Resistance (ESR) measurement is determined by impedance measurement and range. The maximum display is up to 199.99 k and the accuracy is (AZ + Offset) x 1 + Q2
Capacitance
Accuracy = AC + Offset Range
20 mF 2000 F 200 F 20 F 2000 nF 200 nF 20 nF 2000 pF1 200 pF1 20 pF
1
Resolution 100 Hz
0.001 mF 0.1 F 0.01 F 0.001 F 0.1 nF 0.01 nF 0.001 nF 0.1 pF 0.01 pF 0.001 pF 0.5% + 8 0.5% + 5 0.3% + 3 0.2% + 3 0.2% + 3 0.2% + 3 0.5% + 5 0.5% + 10 NA NA
U1731C/U1732C/U1733C 120 Hz
0.5% + 8 0.5% + 5 0.3% + 3 0.2% + 3 0.2% + 3 0.2% + 3 0.5% + 5 0.5% + 10 NA NA
U1732C/U1733C 10 kHz
NA NA 0.5% + 8 0.5% + 5 0.2% + 3 0.5% + 3 0.5% + 3 0.5% + 3 0.8% + 10 1.0% + 20
1 kHz
NA 0.5% + 8 0.5% + 5 0.2% + 3 0.2% + 3 0.2% + 3 0.2% + 3 0.5% + 5 0.5% + 10 NA
1. This accuracy for the ranges of 20 pF~2000 pF is specified after Math Null which is used to substrate the stray capacitances for test leads. Notes: a. The accuracy for the ceramic capacitor will be influenced depending on the dielectric constant (K) of the material used to make the ceramic capacitor. For related influence factors, please refer to the Component dependency factors section in the Impedance Measurement Handbook, downloadable for free at http://www.agilent.com/find/lcrmeters
4
Resolution 100 Hz
0.001 H 0.01H 0.1 H 0.001 mH 0.01 mH 0.1 mH 0.001 H 0.01 H 0.1 H NA NA 0.7% + 10 0.5% + 3 0.5% + 3 0.2% + 3 0.2% + 3 0.7% + 5 1.0% + 5
U1731C/U1732C/U1733C 120 Hz
NA NA 0.7% + 10 0.5% + 3 0.5% + 3 0.2% + 3 0.2% + 3 0.7% + 5 1.0% + 5
U1732C/U1733C 10 kHz
1.0% + 5 0.7% + 3 0.5% + 3 0.3% + 3 0.2% + 3 0.5% + 5 1.0% + 5 2.0% + 8 NA
1 kHz
NA 1.0% + 5 0.5% + 3 0.2% + 3 0.2% + 3 0.2% + 3 0.5% + 5 1.0% + 5 2.0% + 8
Resolution
0.1/1
Accuracy (e)
(AZ + Offset/Zx) x180/
Condition
D < 1 or Q > 1
Impedance
1999.9 199.9 19.9 1.9 Notes:
Zx
19999 1999 199 19
AZ
0.2% 0.2% 0.2% 0.2%
Offset
3 3 3 3
e
0.12 0.20 0.98 9.16
a. Specifications are applicable to all models (U1731C, U1732C, and U1733C) unless specified b. The AZ and Offset are the accuracy specified at impedance c. The is approximately 3.14159
Dissipation/Quality Factor
Function
Z L C
Range
0.001~999 0.001~999 0.001~999
Accuracy (De)
AZ + Offset/Zx x 100% + 3 AL + Offset/Lx x 100% + 3 AC + Offset/Cx x 100% + 3
Condition
D < 1 or Q > 1 D < 1 or Q > 1 D < 1 or Q > 1
Capacitance
88.88 F
Cx
8888
AC
0.2%
Offset
3
De
0.203% + 3
Notes:
1. Specifications are applicable to all models (U1731C, U1732C, and U1733C) unless specified 2. The AZ, AL, AC and Offset are the accuracy specified at Impedance, Inductance, and Capacitance, respectively 3. The Zx, Lx, and Cx are the display count of the reading. For example, the Cx is 8888 as if the capacitance is 88.88 F for the range of 200 F. 4. The Quality Factor is the reciprocal of Dissipation Factor
5
Selection
100 Hz 120 Hz 1 kHz
Level
0.74 Vrms 0.74 Vrms 0.74 Vrms 0.70 Vrms 0.70 Vrms +1.235 V
Accuracy
0.05 Vrms 0.05 Vrms 0.05 Vrms 0.05 Vrms 0.05 Vrms 0.05 V
Accuracy
0.01% 0.01% 0.01% 0.01% 0.01% NA
U1732C/1733C U1733C
U1731C/U1732C/U1733C 120 Hz
100 100 100 1 k 10 k 100 k 100 k 100 k 100 k
U1732C/U1733C 10 kHz
100 100 100 1 k 10 k 10 k 10 k 100 k NA
1 kHz
100 100 100 1 k 10 k 100 k 100 k 100 k 100 k
DCR
100 100 100 1 k 10 k 100 k 100 k 100 k 100 k
U1731C/U1732C/U1733C 120 Hz
100 100 100 100 1 k 10 k 100 k 100 k NA NA
U1732C/U1733C 10 kHz
NA NA 100 100 100 100 1 k 10 k 10 k 100 k
1 kHz
NA 100 100 100 100 1 k 10 k 100 k 100 k NA
U1731C/U1732C/U1733C 120 Hz
NA NA 100 100 100 100 1 k 10 k 100 k
U1732C/U1733C 10 kHz
100 100 100 100 1 k 10 k 10 k 100 k NA
1 kHz
NA 100 100 100 100 1 k 10 k 100 k 100 k
General Specifications
Parameter
Measurements Display
U1731C
Z/L/C/R/D/Q//ESR
U1732C
Z/L/C/R/D/Q//ESR
U1733C
Z/L/C/R/D/Q//ESR/DCR
Primary display: Maximum display 19,999 counts Secondary display: Maximum display 999 counts Automatic polarity indication 100 Hz, 120 Hz, 1 kHz No Selection 100 Hz 120 Hz 1 kHz 10 kHz DCR
2 1
Test frequency (Accuracy = 0.1% of actual test frequency) Backlight Test signal level
100 Hz, 120 Hz, 1 kHz, 10 kHz Yes Test signal level 0.74 Vrms 0.74 Vrms 0.74 Vrms 0.74 Vrms 0.74 Vrms +1.235 V
100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz Yes Test frequency 100 Hz 120.481 Hz 1 kHz 10 kHz 100 kHz NA
100 kHz2 Tolerance mode Ranging mode Measurement rate Response time Auto power-off Power supply Power consumption Input protection fuse Battery life Low battery indicator Operating temperature Storage temperature Temperature coefficient Relative humidity Weight Dimensions (H x W x D) Safety and EMC Compliance Calibration Warranty 1. Only applicable for U1732C/U1733C 2. Only applicable for U1733C 1%, 5%, 10%, 20% Auto and manual 1 time/second, nominal
Approximately 1 second/DUT (Device Under Test) ~0-99 mins without operation Single standard 9 V battery (alkaline or carbon-zinc) or optional power adaptor 225 mVA maximum without backlight Resettable over-current protection 16 hours based on alkaline battery [ ] will appear when voltage drops below ~7.2 V 10 to 55 C, 0 to 80% R.H. 20 to 70 C, 0 to 80% R.H. without battery 0.1 (specified accuracy)/C (from 10 to 18 C or 28 to 55 C) Maximum 80% R.H. for temperature up to 30 C decreasing linearly to 50% R.H. at 55 C 337 grams with battery 184 mm x 87 mm x 41 mm In compliance with EN61010-1 (IEC61010-1:2001) for low voltage directive and Pollution Degree II Environment. Susceptibility and Emissions (EMC): Commercial Limits per EN61326-1 One-year calibration cycle recommended 3 years for main unit 3 months for standard shipped accessories
Ordering Information
Recommended accessories
U1731P Combo Kit Includes one U1731C handheld and four accessories: U5491A soft carrying case U5481A IR-to-USB cable U1780A AC adaptor U1782A SMD tweezer Combo Kit Includes one U1732C handheld and four accessories: U5491A soft carrying case U5481A IR-to-USB cable U1780A AC adaptor U1782A SMD tweezer Combo Kit Includes one U1733C handheld and four accessories: U5491A soft carrying case U5481A IR-to-USB cable U1780A AC adaptor U1782A SMD tweezer Soft carrying case
U1732P
U1733P
U1174A
U5481A
IR-to-USB cable
U1782A
SMB tweezer
U1780A
U1781A
www.agilent.com
www.agilent.com/find/handheldlcr
For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: Agilent Advantage Services is committed to your success throughout your equipments lifetime. To keep you competitive, we continually invest in tools and processes that speed up calibration and repair and reduce your cost of ownership. You can also use Infoline Web Services to manage equipment and services more effectively. By sharing our measurement and service expertise, we help you create the products that change our world.
www.agilent.com/find/advantageservices
www.agilent.com/find/emailupdates Get the latest information on the products and applications you select.
www.agilent.com/find/contactus Americas Canada Brazil Mexico United States Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries
www.axiestandard.org AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium.
(877) 894 4414 (11) 4197 3500 01800 5064 800 (800) 829 4444 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 375 8100
www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of the LXI consortium.
www.agilent.com/quality
www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based highperformance measurement and automation system.
Europe & Middle East Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700*
*0.125 /minute
49 (0) 7031 464 6333 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 44 (0) 131 452 0200
Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2011 Published in USA, June 24, 2011 5990-7778EN