Avanto Application
Avanto Application
I-class
www.siemens.com/healthcare
On account of certain regional limitations Local Contact Information
of sales rights and service availability,
we cannot guarantee that all products in the USA
included in this brochure are available Siemens Medical Solutions USA, Inc.
through the Siemens sales organization 51 Valley Stream Parkway
worldwide. Availability and packaging Malvern, PA 19355
may vary by country and is subject to Phone : +1 888-826-9702
change without prior notice. Some / All Phone : +1 610-448-4500
of the features and products described Fax : +1 610-448-2254
herein may not be available in the United
States. In Japan
All devices listed herein may not be Siemens-Asahi
licensed according to Canadian Medical Medical Technologies Ltd.
Devices Regulations. Takanawa Park Tower 14F
The information in this document con- 20-14, Higashi-Gotanda 3-chome
tains general technical descriptions of Shinagawa-ku
specifications and options as well as stan- Tokyo 141-8644
dard and optional features which do not Phone : +81 3 5423 8411
always have to be present in individual
cases. In Asia
Siemens reserves the right to modify the Siemens Pte Ltd
design, packaging, specifications and Healthcare Sector
options described herein without prior Regional Headquarters
notice. Please contact your local Siemens The Siemens Center
sales representative for the most current 60 MacPherson Road
information. Singapore 348615
Note : Any technical data contained in this Phone : +65 6490 6000
document may vary within defined toler- Fax : +65 6490 6001
ances. Original images always lose a cer-
tain amount of detail when reproduced. Global Business Unit
Siemens AG
Please find fitting accessories : Medical Solutions
www.siemens.com/healthcare-accessories Magnetic Resonance
Henkestr. 127
91052 Erlangen
Germany
Phone : +49 9131 84-0
www.siemens.com/healthcare
Order No. A91MR-500-61-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
T-class
www.siemens.com/healthcare
On account of certain regional limitations Local Contact Information
of sales rights and service availability,
we cannot guarantee that all products in the USA
included in this brochure are available Siemens Medical Solutions USA, Inc.
through the Siemens sales organization 51 Valley Stream Parkway
worldwide. Availability and packaging Malvern, PA 19355
may vary by country and is subject to Phone : +1 888-826-9702
change without prior notice. Some / All Phone : +1 610-448-4500
of the features and products described Fax : +1 610-448-2254
herein may not be available in the United
States. In Japan
All devices listed herein may not be Siemens-Asahi
licensed according to Canadian Medical Medical Technologies Ltd.
Devices Regulations. Takanawa Park Tower 14F
The information in this document con- 20-14, Higashi-Gotanda 3-chome
tains general technical descriptions of Shinagawa-ku
specifications and options as well as stan- Tokyo 141-8644
dard and optional features which do not Phone : +81 3 5423 8411
always have to be present in individual
cases. In Asia
Siemens reserves the right to modify the Siemens Pte Ltd
design, packaging, specifications and Healthcare Sector
options described herein without prior Regional Headquarters
notice. Please contact your local Siemens The Siemens Center
sales representative for the most current 60 MacPherson Road
information. Singapore 348615
Note : Any technical data contained in this Phone : +65 6490 6000
document may vary within defined toler- Fax : +65 6490 6001
ances. Original images always lose a cer-
tain amount of detail when reproduced. Global Business Unit
Siemens AG
Please find fitting accessories : Medical Solutions
www.siemens.com/healthcare-accessories Magnetic Resonance
Henkestr. 127
91052 Erlangen
Germany
Phone : +49 9131 84-0
www.siemens.com/healthcare
Order No. A91MR-500-62-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
A Tim System
www.siemens.com/healthcare
Tim
is changing MRI
forever.
Around the world, Tim (Total imaging matrix)
technology has become the new standard in
MRI. With thousands of installations, Tim is
proving it every day, with unprecedented
flexibility, accuracy and speed. Let Tim prove
it to you, too.
33 Magnet System
35 Gradient System
36 AudioComfort
38 Acquisition Parameters
40 syngo MR Software
49 Computer System
50 Installation
Up to 76 seamlessly
integrated coil elements
with 8, 18, respectively
with 32 RF channels1)
Customer’s advantage :
Revolutionary flexibility –
Select exams, not coils.
4
205 cm FoV. Whole Body at PAT. Unlimited
the highest quality
Tim provides total iPAT (integrated Paral-
Tim puts it all together, for the very first lel Acquisition Techniques) functionality,
time. It allows to exploit maximum SNR in all directions, throughout the entire
while enabling seamless, head-to-toe FoV of 205 cm2). Siemens iPAT with Tim
imaging with a total FoV of up to has highest signal-to-noise, provides two
205 cm2) at full surface coil quality. And different PAT algorithms (mSENSE and
all that without the need to reposition the GRAPPA) for Parallel Imaging, and inte-
patient, or to change a single coil, not grates the time-saving AutoCalibration
even once. Tim or Total imaging matrix into a single scan.
revolutionizes MRI and resolves typical
limitations of local anatomy MR imaging. Customer’s advantage :
Revolutionary speed –
Customer’s advantage : Parallel in all directions.
Revolutionary accuracy –
Local and total.
iPAT Extensions
(integrated Parallel
Acquisition Techniques)
5
Matrix coils Matrix Coil Mode
The new multi-element Matrix coil tech- The Matrix Coil Mode is a user-selectable
nology is an essential part supplementing parameter determining the mode
the most innovative Total imaging matrix. extracted from a cluster of receive coil
elements.
Matrix coils have multiple receive coil
elements that are grouped in clusters. There are three Matrix Coil Modes
Each receive coil element is equipped available :
with a low noise preamplifier to maximize
signal-to-noise ratio. The Matrix coil • CP (Circularly Polarized)
technology includes an intelligent logic • Dual
combining signals into various permu- • Triple
tations and combinations to yield best
SNR from the numerous coil elements. The CP Mode is optimized to obtain maxi-
mum signal-to-noise (SNR) at the center
The Head Matrix, Neck Matrix, Spine of the region of interest. The Dual and
Matrix, and Body Matrix are examples Triple modes contain additional informa-
of the new revolutionary multi-element tion which can be used to improve SNR in
Matrix coils. The Head Matrix, for exam- the periphery of the image and / or enable
ple, has 12 receive coil elements. The higher PAT factors.
receive coil elements are grouped in
4 clusters with 3 coil elements per cluster. The Matrix Coil Modes, which are auto-
Since clusters are working in the matically pre-selected by the system, can
left-right direction, they do not compro- be best compared with the mono, stereo
mise image quality. The signals from the and quattro-reception known from audio
receive coil elements within a cluster can receiver systems : While the mono signal
be chosen from three different Matrix Coil already contains the audio information,
Modes. Depending on the Matrix Coil the stereo or quattro signal adds spatial
Mode selected, the Head Matrix can be information.
operated as a 4, 8 or 12 channel array.
6
CP Mode Dual Mode Triple Mode
With the CP Mode selected, the Head With the Dual Mode selected, the Head With the Triple Mode selected, the Head
Matrix can be operated as a 4-element Matrix can be operated as an 8-element Matrix can be operated as a 12-element
CP head array. There are 4 virtual CP ele- CP head array. There are 8 virtual coil head array. The Triple Mode further
ments. Each virtual CP element is gener- elements. The Dual Mode improves SNR improves SNR and CNR, particularly in the
ated from a cluster of 3 receive coil and CNR (contrast-to-noise ratio), parti- periphery of the image, as more coil ele-
elements. This is the standard mode for cularly in the periphery, as more coil ele- ments receive signal and are available for
non-parallel imaging. However, parallel ments receive signal. Higher PAT factors post-processing. In addition, higher PAT
imaging acceleration can be applied and are available for speed, resolution, more factors are available for speed, resolution,
is only limited by the number of virtual slices or coverage, and image quality. more slices or coverage, and image qual-
coil elements. As in conventional CP array ity. This is the standard mode for parallel
coils, the CP Mode guarantees optimum imaging and provides maximum ultra-fast
SNR at the center of the image. acquisition as well as high resolution iPAT
imaging.
In the past, the signals from independent utilized, resulting in higher SNR and CNR, Superior Tim technology, revolutionary
receiver coils within an array were directly particularly in the periphery of the image. multi-element Matrix coils, excellent
connected to independent receiver chan- On one hand, it allows for a higher experience with iPAT and the intelligent
nels. The Matrix coil technology allows flexibility of iPAT as well as higher acceler- logic available with the Coil Mode are
an unprecedented flexible and efficient ation factors. On the other hand, even collectively triggering a revolution in MR
use of receiver channels. The higher the with the CP or Dual Mode selected, the imaging.
Matrix Coil Mode, the more independent SNR at the center of the region of interest
receiver channels per Matrix coil are is always optimal.
7
Tim Application Suite
The Tim Application Suite has a complete Neuro Suite This package includes, for example :
range of clinically optimized examina-
tions for all regions. Excellent head-to-toe The Neuro Suite is a part of the Tim • EPI sequences and protocols for diffu-
imaging can be accomplished with the Application Suite. Comprehensive head sion imaging, perfusion imaging, and
sequences and features included in this and spine examinations can be performed fMRI for advanced neuro applications.
Application Suite. The Tim Application with dedicated programs that are opti- Diffusion-weighted imaging is possible
Suite – which exploits fully the benefits mized for clinical examinations. High with up to 16 b-values in the orthogonal
of Tim – is provided in standard on the resolution protocols and fast protocols for directions. In addition diffusion tensor
MAGNETOM Avanto. uncooperative patients are provided, as imaging measurements can be done
well as protocols optimized for pediatric with multiple diffusion weightings and
There are nine dedicated application applications. Neuro Suite also includes up to 12 directions
packages – all of them have been protocols for diffusion imaging, perfusion • 3D isotropic resolution volume imaging
included as standard applications. imaging, and fMRI. using T1 3D MPRAGE / 3D FLASH,
All of them are based on the revolution- SPACE DarkFluid, T2 SPACE and 3D TSE
ary Tim technology : • T2-weighted high resolution 3D Restore
protocols optimized for inner ear exami-
• Neuro Suite nations
• Angio Suite
• Cardiac Suite
• Body Suite
• Onco Suite
• Breast Suite
• Ortho Suite
• Pediatric Suite and
• Scientific Suite
8
• Whole-spine protocols in multiple
steps with software-controlled table
movement
• 2D and 3D MEDIC protocols for
T2-weighted imaging, particularly
for C-spine examinations in axial
orientation where reproducibility is
difficult due to CSF pulsations and
blood flow artifacts
• 3D Myelo with 3D HASTE and
3D True-FISP for anatomical details
• Dynamic sacro-iliac joint imaging after
contrast administration using a fast
T1-weighted FLASH 2D sequence
• Spine diffusion protocols to differentiate
osteoporosis versus tumor infiltration
and post-radiotherapy changes versus
residual tumor with PSIF sequence
• Precision filter for high spatial accuracy
e.g. for neuro intra-operative imaging
and stereotactic planning
• 3D CISS (Constructive Interference in
Steady State) for excellent visualization
of fine structures such as cranial nerves.
High resolution imaging of inner ear
and spine
9
Angio Suite Contrast-enhanced MRA
The Angio Suite is also a part of the Tim • 3D contrast-enhanced MRA protocols
Application Suite. Excellent MR Angiogra- with or without iPAT for head, neck,
phy can be performed to visualize arteries thorax, abdomen, peripheral regions
and veins with or without contrast agent. with the shortest TR and TE. The strong
gradients make it possible to separate
This package includes, for example : the arterial phase from the venous
phase. No venous contamination is seen
due to the ultra-fast ce-MRA protocols
• CareBolus functionality for excellent
results. It supports accurate determina-
tion of the bolus arrival time and the
“Stop and Continue” of the 3D ce-MRA
protocol after the 2D bolus control scan
• Excellent peripheral ce-MRA can be
acquired with Tim’s flexible coil combi-
nations
10
Image processing tools
11
Cardiac Suite Cardiac views
The Cardiac Suite covers a comprehensive • Fast acquisition of the basic cardiac
2D routine cardiac application range from orientations for further examination
morphology, ventricular and valvular planning
function to tissue characterization, coro- • Cardiac scouting provides users with
nary imaging and angiography. Featuring a step-by-step procedure for the
syngo BEAT 2D. visualization and planning of typical
cardiac views, e.g. based on TrueFISP
This package includes, for example : or Dark Blood TurboFLASH : short-axis,
4-chamber and 2-chamber views
syngo BEAT
12
Global and regional ventricular wall
motion analysis with syngo BEAT
13
Body Suite • dynaVIBE – Inline motion correction
of multi-phase VIBE data sets of the
The Body Suite is dedicated for clinical abdomen for increased conspicuity
body applications. Ultra-fast high reso- of small lesions
lution 2D and 3D protocols are provided • High resolution pelvic imaging
for abdomen, pelvis, MR Colonography, (prostate, cervix) for tumor visualization
MRCP, dynamic kidney, and MR Urography with T2 SPACE
applications. Siemens-unique 2D PACE • Colonography bright lumen with
technique makes body imaging simple, T2-weighted TrueFISP and dark lumen
allowing for multi-breath-hold exami- with T1-weighted VIBE
nations as well as free breathing during • Dynamic volume examinations with
the scans. Motion artifacts are mostly 3D VIBE with high spatial and temporal
reduced with the 2D PACE Inline Technol- resolution, available with 2D PACE
ogy. (Prospective acquisition motion under
control), beneficial for patients unable
This package includes, for example : to hold their breath
• syngo REVEAL (diffusion-weighted
• Free breathing 2D PACE applications imaging for liver and whole body),
with 2D / 3D HASTE (Restore) and prerequisite : Inline Diffusion
2D / 3D TSE (Restore) • syngo REVEAL with 2D PACE for respira-
• Optimized fast single-shot HASTE proto- tory synchronized measurements
cols and high resolution 3D Restore
protocols for MRCP and MR Urography
examinations Dedicated workflow and
• Excellent fat suppression protocols with ease-of-use features
Quick FatSat, STIR, HASTE, FLASH, SPAIR
and 3D VIBE (in-phase / opposed-phase) • Matrix coils provide flexibility to
protocols and multi-echo TSE combine coil elements and have a large
• DIXON – 2 point Dixon with 3D VIBE. anatomical coverage for both tall or
The following contrasts can be large patients. Up to 3 Body Matrix*
obtained : in-phase, opposed phase, fat coils can be connected
and water image • Inline Technology reduce post-
• Dynamic 3D VIBE protocols for best processing steps
visualization of focal lesions with high • 2D PACE eliminates the need for
spatial and temporal resolution respiratory belt
14
Onco Suite This package includes, for example :
MR imaging has the advantage of excel- • 3D VIBE, FLASH and STIR-TSE in-phase /
lent soft tissue contrast, multi-planar opposed-phase protocols with a high
capabilities and the possibility of selec- sensitivity to metastases detection
tively suppressing specific tissue e.g. fat • Dynamic imaging protocols for assess-
or water. This helps in the detection ment of the kinetic behavior for lesion
of pathologies, particularly metastases. visualization and characterization,
The Onco Suite features a collection including dynaVIBE, a dynamic 3D VIBE
of sequences as well as protocols and with inline motion correction of multi
evaluation tools that guide through a phase data sets of the abdomen
detailed screening of clinical questions. • Quantitative evaluation and fast
analysis of the data with colorized
Wash-in, Wash-out, Time-To-Peak,
Positive-Enhancement-Integral,
MIP-time, and combination maps
with Inline Technology or for offline
calculation
• Display and analysis of the temporal
behavior in selected regions of interest
with the included MeanCurve post-
processing application. This includes the
capability of using additional datasets as
a guide for defining regions of interest
even faster and easier than before
• syngo REVEAL (diffusion-weighted
imaging for liver and whole body),
prerequisite : Inline Diffusion
• Precision filter for high 3D spatial
accuracy e.g. for radiotherapy planning,
neuro intra-operative imaging and
stereotactic planning
Diffusion-weighted imaging
15
Prostate protocols
16
Breast Suite Siemens Technique : VIEWS
(Volume Imaging with Enhanced Water
MRI has shown to be extremely sensitive Signal)
for the visualization of breast lesions and
MR can be a definitive exam for implant • Bilateral – both breasts are scanned
assessment. simultaneously
• Axial – ductal paths can be directly
High spatial and temporal resolution can visualized
be obtained in extremely short acquisi- • Fat-saturated or water stimulated –
tion times (e.g. 1 minute) supported by fat impedes clinical analysis and
iPAT (GRAPPA and SENSE) techniques. requires suppression
• 3D – utilizing the full potential of MRI
Excellent soft tissue characterization, • Near isotropic – same dimensions in
multi-planar viewing capabilities and all directions
tailored techniques (e.g. fat suppression • Sub-millimeter voxels – high resolution
and water excitation) allow fast, easy for great morphological analyses
and reproducible evaluation of breast • Excellent reconstruction in any plane
MR examinations. • Including RADIANT (ultra-sound like
reconstruction around the nipple)
This package includes, for example :
17
Ortho Suite This package includes, for example :
The Ortho Suite is a comprehensive • 2D TSE protocols for PD, T1, and
collection of protocols for joint imaging T2-weighted contrast with high
including the spine. Avascular necrosis in-plane resolution and thin slices
and internal derangements may benefit • 3D MEDIC, 3D TrueFISP protocols with
from MR. Also in case of tumors and water excitation for T2-weighted
infections, a large amount of additional imaging with high in-plane resolution
information can be acquired using the and thin slices
protocols provided as standard in this • High resolution 3D VIBE protocols for
suite. MR Arthrography (knee, shoulder and
hip)
• 3D MEDIC, 3D TrueFISP, 3D VIBE
protocols with Water Excitation having
high isotropic resolution optimized
for 3D post-processing
• T2 SPACE and PD SPACE, 3D imaging
with high isotropic resolution optimized
for post-processing
• Whole-spine, single-step and
multi-step protocols
• Excellent fat suppression in offcenter
positions, e.g. in the shoulder due to
high magnet homogeneity
• Dynamic TMJ protocol
(different joint positions)
• Dynamic ilio-sacral joint protocol
for contrast dynamics
• Susceptibility-insensitive protocols
• Multi Echo SE sequence with up to
32 echoes for T2 time mapping
• High resolution 3D DESS (Double Echo
Steady State) : T2 / T1-weighted imaging
for excellent fluid-cartilage differentia-
tion
18
Pediatric Suite
Neuro Cardiovascular
19
Scientific Suite Sequences • 2D / 3D MEDIC (Multi Echo Data Image
Combination) for high resolution
The Scientific Suite supports scientific T2-weighted orthopedic imaging and
users by providing easy access to applica- Spin Echo family of sequences excellent contrast
tion-specific data for further processing • 2D / 3D TurboFLASH – 3D MPRAGE ;
and advanced image calculus. • Spin Echo (SE) – Single, Double and single shot T1-weighted imaging e.g.
Multi Echo (up to 32 echoes) ; for abdominal imaging during free
This package includes, for example : Inversion Recovery (IR) breathing
• 2D / 3D Turbo Spin Echo (TSE) – • 3D GRE for field mapping
• Support of USB Memory sticks Restore technique for shorter TR times • 2D / 3D FISP (Fast Imaging with
• Access to file system via a secure while maintaining excellent T2 contrast ; Steady State Precession)
and comfortable File Browser TurboIR : Inversion Recovery for STIR, • 2D / 3D PSIF – PSIF Diffusion
• Anonymization of patient data DarkFluid T1 and T2, TrueIR ; • Echo Planar Imaging (EPI) – diffusion-
• Easy creation of AVIs and screen Echo Sharing for dual-contrast TSE weighted ; single shot SE and FID
snapshots to include in presentations • 2D / 3D HASTE (Half-Fourier Acquisition e.g. for BOLD imaging and Perfusion
or teaching videos with Single Shot Turbo Spin Echo) – weighted imaging ; 2D / 3D Segmented
• Export of tables, statistics and signal Inversion Recovery for STIR and EPI (SE and FID)
time courses to communal exchange DarkFluid contrast ; • 2D / 3D TrueFISP – Shared Phases
formats like e.g. tabulated text files • SPACE for 3D imaging with high isotro- Real-time TrueFISP (w / o ECG gating)
(MeanCurve, Spectroscopy evaluation, pic resolution with T1, T2, PD, and • ce-MRA sequence with Inline
DTI evaluation) DarkFluid contrast subtraction and Inline MIP
• Advanced image calculus including • 2D / 3D Time-of-Flight (ToF) Angio-
T2 and T1 time calculation, addition, graphy – single slab and multi slab ;
subtraction, multiplication, division, Gradient Echo family of sequences triggered and segmented
log and integration of images • 2D / 3D Phase Contrast Angiography –
• 2D / 3D FLASH (spoiled GRE) – dual multiple velocity encoding ; triggered
echo for in- / opposed phase imaging • syngo BEAT Tool – TrueFISP segmented ;
• 3D VIBE (Volume Interpolated Breath- 2D / 3D FLASH segmented ;
hold Examination) – quick fat Magnetization-prepared TrueFISP
saturation ; double echo for in-phase / (IR, SR, FS) ; IR TI scout ; Retrogating
opposed phase 3D imaging ;
DynaVIBE : Inline 3D elastic motion cor-
rection for multi phase data sets of the
abdomen ; Inline Breast Evaluation
20
Tim Application Suite : • Saturation Recovery for 2D TurboFLASH, • MTC (Magnetization Transfer Contrast).
Acquisition and Reconstruction gradient echo, and T1-weighted Off-resonance RF pulses to suppress
Techniques 3D TurboFLASH with short scan time signal from certain tissues, thus enhanc-
(e.g. MPRAGE) ing the contrast. Used e.g. in MRA
• 1D / 2D PACE (Prospective Acquisition • Presaturation Technique. RF saturation • TONE (Tilted Optimized Non-saturating
CorrEction) pulses to suppress flow and motion Excitation). Variable excitation flip angle
• Whisper Mode for scanning with artifacts. Up to six saturation bands may to compensate inflow saturation effects
reduced noise ; beneficial for children, be positioned in any orientation in 3D MRA. TONE pulse selectable
non-cooperative, or anxious patients • Tracking SAT Bands maintain constant depending on the desired flow direction
• LOTA (Long Term Data Averaging) saturation of venous and / or arterial and speed
technique for motion and flow artifact blood flow, e.g. for 2D / 3D sequential • GMR (Gradient Motion Rephasing).
reduction without increasing scan time MRA Sequences with additional bipolar
• Elliptical scanning reduces scan time for • Fat Saturation. Additional frequency gradient pulses, permitting effective
3D imaging selective RF pulses, used to suppress reduction of flow artifacts
• Selectable centric elliptical phase bright signal from fatty tissue. Two • Freely adjustable receiver bandwidth,
reordering via the user interface selectable modes : weak, strong permitting studies with increased
• Inversion Recovery to nullify the signal • Water Saturation. All sequences used signal-to-noise ratio
of fat, fluid or any other tissue for fat saturation can also be used to • Freely adjustable flip angle. Optimized
• True Inversion Recovery to obtain strong suppress the water signal RF pulses for image contrast enhance-
T1-weighted contrast • Quick FatSat ment and increased signal-to-noise ratio
• Dark Blood inversion recovery technique • SPAIR : robust fat suppression for body • PAT averaging for motion artifact
that nulls fluid blood signal imaging using a frequency selective suppression using Self-Calibration
inversion pulse
• Fat Excitation. Spectral selective
RF pulses for exclusive fat excitation
• Water Excitation. Spectral selective
RF pulses for exclusive water excitation
• Silicone detection for breast examina-
tions
21
Highlights Inline Technology –
Processing Instead of
• syngo MR – the cross-modality intuitive Post-processing
user interface
• syngo Scan Assistant Inline Technology helps to streamline
• Inline Technology the clinical workflow by automating
• 1D / 2D PACE Inline motion correction mundane post-processing steps before
• Advanced workflow features such as image viewing. See the clinical results
image stamps, Inline display, Inline immediately.
movie functionality
• iPAT – high-performance and flexible Examples are :
Parallel Imaging. Tim and its Matrix coils
are combined with the most innovative • Automatic subtraction of images, e.g.
implementation of PAT for highest pre- and postcontrast enhancements
speed and resolution • Automatic on-the-fly calculation of stan-
• The Tim Assistant and the Intelligent dard deviation, for better differentiation
Coil Control help maximize PAT factors of arterial and venous phases
according to the selected coils to
achieve exemplary image quality in the
shortest time
• Phoenix functionality for reproducible
image quality and for benefiting from
other MAGNETOM users sharing their
protocols
• scan@center enables maximum image
quality by automatically moving the
table into the magnet isocenter with
every scan
• Argus viewer for reviewing cine studies
• Report Viewer for DICOM structured
reports including report editing
• Dynamic Analysis for addition, subtrac-
tion, division, standard deviation, calcu-
lations of ADC maps, T1 and T2 values,
TTP, t-Test etc.
• Image Filter
• 3D post-processing MPR, MIP, MinIP, SSD
• Software-controlled patient table
movement for a total coverage of
154 cm (standard) • MIP on-the-fly, i.e. MR Angiography
• Flexible film formats and paper print with automatic image subtraction and
• Data storage of images and cine avi files following MIP in three orthogonal
on CD / DVD with DICOM viewer as the planes, stored as a separate study
viewing tool • Prospective motion correction
(1D and 2D PACE) on-the-fly
• Automatic diffusion and perfusion
imaging
• Automatic soft tissue evaluation
22
Scan
Calibration
required each time
the patient moves
Calibration
overall examination time Scan
Scan 1 sec
Initial
calibration Scan
Calibration
1 sec
other PAT techniques Siemens iPAT
iPAT (integrated Parallel • iPAT is the Siemens Parallel Imaging Higher speed and temporal resolution can
Acquisition Techniques) solution. It is fully integrated. be used for :
PAT factors up to 4 are implemented in
the Tim Application Suite • Improved image resolution
• Two algorithms – mSENSE and • Improved image quality due to reduced
GRAPPA – included for maximum quality artifacts
for all applications • More slices and coverage in the same
• Integrated AutoCalibration includes an breath-hold
immediate reference (calibration) scan
to additionally save on total scan time
• TurboCalibration uses a separate
measurement directly before the actual
measurement. Images measured using
TurboCalibration are characterized by
reduced PAT artifacts. TurboCalibration
is only used in conjunction with GRAPPA
• PAT averaging for motion artifact
suppression using Self-Calibration
• iPAT is compatible with all relevant
sequence techniques (e.g. SE, TSE,
Restore, SPACE, MEDIC, TIRM DarkFluid,
HASTE, EPI, MPRAGE, 3D VIBE, FLASH,
TrueFISP, TurboFLASH, FLASH Phase
Contrast, etc)
• iPAT is compatible with all Matrix coils,
all array coils, as well as coil combina-
tions
• Tim Assistant facilitates optimized iPAT
settings
23
1D PACE Fast Navigator
24
syngo BLADE
with
BLADE
25
Tim – Matrix Coils and RF Technology
RF Receiver Technology
26
Matrix coils The following Matrix coils are
standard :
The multi-element Matrix coil technology
is an essential part supplementing the • Head Matrix coil 4-channel CP Mode,
Total imaging matrix. 8-channel Dual Mode, 12-channel
Triple Mode
It is the next generation IPA (Integrated • Neck Matrix coil 2-channel CP Mode,
Panoramic Array) technology from 4-channel Dual Mode
Siemens. With new advances in MR imag- • Spine Matrix coil 8-channel CP Mode,
ing, the IPA coil technology evolved into 16-channel Dual Mode, 24-channel
the Matrix coil technology. The Matrix coil Triple Mode
design has an intelligent logic that com- • Body Matrix coil 2-channel CP Mode,
bines signals in various permutations and 4-channel Dual Mode, 6-channel
combinations to yield best SNR from the Triple Mode (up to 4 Body Matrix coils
numerous coil elements. can be utilized simultaneously)
27
Integrated CP Body Coil
Additional RF Coils
28
Digital Signal Processing System
29
Tim – Workflow and Patient Handling
Tim ensures increased patient comfort The scan range of 205 cm1) allows for
and optimized workflow efficiency. whole body examinations with full usage
of the surface coils, however, without the
• Only one patient setup, no need for patient repositioning. This saves
repositioning, no changing of coils time without compromising image quality.
• Ultra-light weight coils
• Imaging with optimized surface coil
quality
Patient Table
• Remote table move
• Feet-first examinations for many
applications Free-floating table : Free foot room for the
attending staff and better access to the
The majority of applications can be patient (cantilevered table design)
performed in the feet first position, e.g.
cardiac, liver, upper abdomen, pelvis, Table extends approx. 53 cm (104 cm1))
colonography, body angio, reducing the beyond the back of the system for addi-
level of anxiety experienced by highly tional patient access
claustrophobic patients.
Removable tabletop and trolley (optional)
Patient Table
Max. patient weight 250 kg (550 lbs)
(including vertical movement)
Max. scan range 154 cm,
opt. 205 cm1)
Vertical table movement Range 47 − 89 cm
Max. speed 10 cm / s
Longitudinal table movement Max. range 263.5 cm
Max. speed 20 cm / s
30
Patient Positioning Aids Physiological Measurement Unit External Trigger Input Display
(PMU) – Wireless Physio Control
Standard set of cushions for comfortable ECG Triggering
and stable patient positioning together Synchronizes the measurement with the
with safety straps. physiological cycles (triggering to mini- Acquisition of multiple slices, e.g. of the
mize motion artifacts caused by cardiac heart, at different phases of the cardiac
Additional positioning supports and respiratory movements) cycle.
(optional)
Excellent image quality by synchronizing
• Set of vacuum cushions (large, medium, Wireless Sensors data acquisition with the heart motion
small) with vacuum pump
• Cushions filled with gel for improved fat Wireless Vector ECG / respiration and pulse Peripheral Pulse Triggering
saturation sensors for physiologically synchronized
imaging, rechargeable battery-powered – Reduces flow artifacts caused by pulsatile
for optimized patient handling blood flow
Patient Comfort Facilities
• VCG acquires ECG signal from two Excellent image quality by synchronizing
projection directions, for easy identifi- data acquisition to the pulsatile blood
Facilities at the tableside control unit cation of the R-wave flow
and at the syngo Acquisition Workplace • ECG – disposable electrodes
• Pneumatic cushion to be placed on the Respiratory Triggering
• In-bore lighting (3 levels) chest or abdomen
• In-bore ventilation (3 levels) • The signals can be transmitted to an Excellent image quality by synchronizing
• In-bore intercom via loudspeaker, external MRI-compatible Patient Moni- data acquisition with the respiratory
microphone and earphones toring System (option) via a respective motion
• Look-out mirror 90° receiver interface in the Patient Moni-
toring System External Triggering
31
Tableside Control Units Patient Communication
Two ergonomically designed units Assistance call via squeeze-bulb for the
integrated into the front covers patient
(one on each side of the patient tunnel ;
3rd unit at the rear end, optional) Ergonomically designed patient commu-
nication unit – may be placed at any con-
venient location on the Workplace table
Controls
• Intercom communication with the
• Table up / down patient
• Table in / out in 2 speed levels • Response to the patient’s activation
• Table stop of the squeeze-bulb
• Laser light localizer • Table stop
(peak power < 3 mW, • Volume of speaker in control room
wave length 540−700 nm, • Volume of speaker and headphones in
Class II laser product) examination room for voice commands
• Automatic transfer to isocenter • Connection to external audio system
• Home position (auto transfer) • Independent volume control of voice
• Ventilation within the patient tunnel and music
(adjustable in 3 levels) • Pneumatic system of headphones
• Lighting within the patient tunnel • Loudspeaker
(adjustable in 3 levels) • Microphone
• Scan start, scan stop
• Volume of speaker and headphones in Automatic and freely programmable voice
examination room for external audio commands for breath-hold examinations.
system
32
Magnet System
Superconducting Magnet
54.5 cm 88 cm
150 cm
160 cm
Magnet Bore
Magnet length 150 cm
1)
Magnet bore diameter 90 cm
Inner tunnel length 88 cm
Length of flared opening 54.5 cm
2)
Inner diameter 60 cm
System length 160 cm
Magnet Parameters
Operating field strength 1.5 Tesla
Superconductor Niobium-Titanium
Field stability over time < 0.1 ppm / h
Number of field-generating coils 7
33
Homogeneity DSV Guaranteed Typical
(based on highly accurate 24 plane plot) 50 cm < 1.5 ppm 0.8 ppm
45 cm < 1 ppm 0.4 ppm
40 cm < 0.75 ppm 0.2 ppm
30 cm < 0.5 ppm 0.1 ppm
20 cm < 0.25 ppm 0.04 ppm
10 cm < 0.05 ppm 0.01 ppm
DSV = Diameter spherical volume Standard deviation Vrms (volume root-mean
(x, y, and z direction) square) measured with highly accurate
24 plane plot method (20 points per plane)
Standard active shim with 3 linear channels
3D Shim
Patient-specific automated shim
For optimization of the magnetic field homogeneity
Time to shim approx. 20 s
34
Gradient System
35
AudioComfort
36
Sequence Design “Whisper Mode” Clinical Benefits
• Optimized sequence timing The “Whisper Mode” is a user selectable • High performance combined with
• Sequences automatically avoid mode that reduces the max. slew rate quietness. All gradient demanding
parameter settings that cause and max. amplitude of the gradients. protocols using e.g. EPI techniques
the gradient coil to resonate It is compatible with nearly all sequence such as diffusion, perfusion or fMRI
• No relevant application drawbacks – techniques. examinations show a significant
no increase in sequence parameters, acoustic noise reduction, thanks to
i.e. full performance Siemens-unique AudioComfort
• AudioComfort makes MR examinations a
Acoustic Noise
comfortable experience even for
children
Max. acoustic noise level* : < 99 dB(A) • AudioComfort prevents the necessity
of implementing noise-absorbing
With AudioComfort, acoustic noise measures to gain a comfortable noise
is reduced by up to 30 dB as compared level for technologists and neighbors
to conventional systems.
37
Acquisition Parameters*
2D Slices
Number of slices
per single slice stack 1 − 128 (steps of 1)
per series up to 262 144
(total number of slices in one (depending on matrix size)
dynamic measurement)
Slice order ascending, descending or interleaved
3D Slabs / Partitions
Number of 3D partitions 4 − 512
per single slab
Number of 3D slabs 1 − 128 (steps of 1)
(3D volumes)
Acquisition Matrix
Frequency encoding 64 − 1024 (in steps of 64)
(true imaging matrix without
interpolation or oversampling)
Phase encoding 32 − 1024 (in steps of 1)
Averaging
Number of data acquisitions 1 − 32 (steps of 1)
Averaging mode short term, long term (LOTA)
38
Oversampling
Read oversampling 100 % standard
Phase oversampling 0 % − 100 % (steps of 12.5 %)
Slice oversampling 0 % − 100 % (steps of 12.5 %)
(3D volumes)
Interpolation
In-plane interpolation in frequency- selectable (factor of 2)
encoding and phase-encoding direction
3D interpolation (3D volumes) selectable (up to factor of 2)
Slice Orientation
Slice orientations for transverse, sagittal, coronal, oblique,
2D scans and 3D scans double oblique (steps of 0.1°)
Multi-slice multi-angle yes
(simultaneously)
Off-center Shift
Longitudinal direction – 250 mm to + 250 mm
(head-feet)
Horizontal direction – 250 mm to + 250 mm
(left-right)
Vertical direction – 250 mm to + 250 mm
(anterior-posterior)
Serial Acquisitions
Number of repeat scans with constant 1 − 4096
delay times
with different 1 − 65
delay times
Swap
Exchange of read-out and yes
phase-encoding direction
39
syngo MR Software
syngo®, the unique software platform Its intelligent automation features accel-
for medical applications and systems, erate your examination, enabling smooth
integrates all patient related information, efficient workflow, across modalities,
physiological and imaging data across departments and people. With syngo,
your entire clinical workflow. In every your workplace is uniquely customized to
workplace syngo’s innovative user inter- the way you work. The “program“ concept
face allows you to know intuitively what in syngo MR enables scanning patients
to do. with a minimum of mouse clicks. This
speeds up the total examination time.
Intelligent Features
40
Tim Assistant Image Filter Scan Open Protocol
Helps to make Parallel Imaging easy The Image Filter Software uses adaptive Allows faster workflow for breath-hold
by automatically recommending the filtering and adjusts to the local image exam.
appropriate PAT factor for the selected content automatically. The Image Filter is
application. Tim Assistant always knows available “inline” and “offline” on the
the selected coil elements and the syngo Acquisition Workplace and “offline” Table Positioning Interface
MR protocol, ensuring the optimal iPAT on the syngo MR Workplace. Default and
configuration for each application. freely definable image filter values are Remote software control of table move
provided. and patient comfort facilities, such as
in-bore ventilation and lighting.
scan@center
Inline Applications Card
Easy planning – best position scanning. Physiological Display
scan@center automatically moves the Programming of Inline processes for
table so that the scan is performed in the the current protocol Displays the pulse, ECG or respiration
magnet isocenter. This enables best signal, combined with a graphical indica-
image quality especially for fat saturation • Subtraction tion of the acquisition window.
techniques. Extended Field of View exam- • Standard deviation
inations benefit from this functionality as • MIP
well as multi-stage examinations. • Soft tissue evaluation Automatic Voice Command
Inline Movie
41
Phoenix is standard on all MAGNETOM
systems
PhoenixZIP
42
syngo MR Examination Autoscout
43
syngo MR Image Viewing Evaluation 2D Post-processing
and Filming
Parallel evaluation of up to Image manipulations
40 regions of interest
Image Recall • Reversal of gray-scale values
• Circle • Image rotation by 90° or by
Images are stored in DICOM format, • Rectangle user-defined angle
allowing fast image access and recall • Freehand ROI • Flip horizontally / vertically
• Pixel lens with position marker • Image zoom and pan
• Combines images in a new series, • Statistical evaluation • Shutter
e.g. post-processed images • Area • Annotation
• Loads images automatically • Standard deviation
• Inline Display • Mean value
• Min / max values Argus Viewer
• Image scrolling
Image Display • Magnification Viewing software for cardiac MR studies
• Distance and large data sets
• Various display layouts selectable • Angle
• Up to 3 patients can be simultaneously • Efficient cine review of cardiac and
active in the viewer other dynamic data sets
• Image annotation and labeling Position display • Multiple sorting options
• Non-interpolated display • Single movie as well as 2, 4, or 8
• Fast paging through up to 500 images Displays measured slice positions on simultaneous slices together in movie
with 15 images / s for full screen display localizer image and selected series. mode
• Rapid avi creation of 1 to 8 slices
simultaneously
Windowing • Creates and edits DICOM structured
reports
• Freely selectable window width and
center
• Windowing on succeeding images
• Auto-windowing for optimized contrast
• Saves and sends window values
44
Mean Curve Dynamic Analysis
45
syngo MR 3D Post-processing
46
MinIP – Minimum Intensity Projection syngo MR Network
Communication
Similar to MIP but reconstructs the
minimum intensity (e.g. for Dark Blood
techniques) DICOM Services (Digital Imaging and
Communications in Medicine)
• Volume of Interest (VoI) defined to
increase reconstruction speed and to Interface for transmitting medical
improve image quality images and information in the DICOM 3.0
• Freehand minMIP : virtually eliminating industrial standard
interfering overlays by manually drawn,
irregular contours in all dimensions Allows for communication between
• Arbitrary views along any direction can devices from different manufacturers
be defined interactively with mouse-
driven virtual trackball • DICOM Send / Receive
• Multiple view angles around any ortho- • DICOM Query / Retrieve
gonal axis • DICOM SC Storage commitment
• Projections displayed as single images, • DICOM Basic Print
as interactive movie or by fast paging • DICOM Modality Worklist
• MinIP thin / MinIP thick • DICOM MPPS Modality performed
procedure steps ; communication
back to information system
SSD – Shaded Surface Display • DICOM Structured Reports
47
DICOM Study Split • Overlapping region images can be Provided in conjunction with a service
copied to both studies contract with Siemens (UPTIME Services)
DICOM Study Split provides the mapping
of one study acquired based on multiple • Remote access granted only with per-
requests to multiple studies directly at the Exchange Media mission of the institution. Data security
scanner. For example, two requests for is ensured by secure access
head and neck acquisition can be regis- Storage of images and additional data
tered once, scanned once and immedi- (e.g. avi files) on CD / DVD.
ately mapped to two separate studies for Virus Protection
individual reading. A viewing tool (DICOM Viewer) can be
stored together with images on a DICOM Permanent scanning for malicious
Multiple requested procedures can be CD / DVD to be handed out to the patient. software in the background to provide
combined in a time saving manner by maximum security
scanning a larger body region and then
splitting them to individual billing Remote Diagnostics Via Remote Access over secure network
relevant studies for separate reading. connection the latest virus scanner
Direct computer link to the local Siemens updates and operating system hotfixes
This package allows : service department or the Siemens are installed automatically
service centers (via router with telephone
• Time saving simple mapping of multiple connection) Provided in conjunction with a service
requested procedures to multiple contract with Siemens (UPTIME Services)
acquired series with one scan Image transfer for further evaluation
• Simple creation of studies with individ-
ual billing based on one scan workflow • Image and file transfer in batch mode MPPS
• Improvement for departmental • Reading of entries in the error logbook
workflow by eliminating need to load / • Remote trouble shooting DICOM Modality Performed Procedure
change and to request / execute splitting • Remote access to service manuals Steps (MPPS) allows communication of
on a separate workstation after the scan written in easy-to-use HTML format information about the examinations from
• Immediate visual selection, check • Remote access to Service Site Database the MR system to an information system
and correction of images to study • Start of preventive maintenance and (such as RIS systems). MPPS enables pro-
assignments. quality assurance routines vision of data for billing, documentation
and planning purposes to an information
system.
Image Transfer
Local network Ethernet
Data transfer rate max. 1 Gbit / s
Transfer rate (256 x 256 image) approx. 20 images / s
48
Computer System
syngo Acquisition Workplace Color LCD Monitor Host Computer and MCPro
Multi2 Image Processor :
Full multi-tasking for High resolution flicker-free Technical Data
simultaneous functionality, flat-screen monitor
e.g. : > Refer to appendix
Horizontally tiltable, forward “Computer System”
• Patient registration and backward
and pre-registration
• Scanning Automatic backlight control
• Reconstruction for long-term brightness stability
• Viewing
• Post-processing
• Filming
• Data storage
49
Installation
Magnetic Shielding
Room shielding For additional reduction of the
magnetic fringe field, suitable iron
shielding can be installed in the walls
of the examination room. The room
shielding can be used to create a
magnetic shielding enclosure
One-Floor Installation A combination of active shielding and
a special shielding installed on the
ceiling of the magnet room or below it
will keep the 0.5 mT line within the
same floor as the MAGNETOM Avanto,
even in case of very low room heights
50
System Electronics Cabinets
2 cabinets which may be placed directly against the wall or even in a corner
Require service access only from the front, saving considerable space
Integrated water cooling eliminates the need for a dedicated computer room
Power Requirements
Line voltage 380, 400, 420, 440, 460, 480 V
Stability tolerances ± 10 %
Line frequency 50 / 60 Hz, ± 1 Hz
Connection value* 110 kVA for SQ-engine gradients
70 kVA for Q-engine gradients
* Long-term average in full operation
Power Consumption
System off 1) ≤ 5.0 kW
1)
Stand-by ≤ 5.7 kW
1)
Ready for measurement ≤ 11.5 kW
1)
Typical measurement ≤ 15.5 kW for Q-Engine
≤ 16.0 kW for SQ-Engine
Space Requirements
Min. total space requirement (for ≤ 27 m2 (290 sq ft)
magnet, electronics and console room)
51
Dimensions Component Width Depth Height Weight Heat
[cm] [cm] [cm] [kg] Dissipa-
tion [kW]
Examination Room
Magnet 1.5 Tesla AS 207 150 210 4050 ± 80
(incl. Helium)
Magnet in operation, incl. 229.5 405 230 5850 3
gradient coil, body coil,
patient table, and covers
Patient table 54 (top) 243 47 − 89 350
Required min. room height 235
clearance
Min. transport dimensions 230 / 305 / 210*
207* 170*
Control Room
syngo Acquisition 120 80 117 2
Workplace (72+45)
(table + monitor)
Host computer 22 46 47
syngo MR Workplace 120 80 117
(optional) (72+45)
(table + monitor)
Equipment Room
Electronics cabinet, 160 65 189** 1500 5
incl. system control,
RF system, gradient power
system, image processor
Cooling system 65 65 189** 500
* Without covers, electronics, table and table bracket
** Without attachments
52
System Cover
53
On account of certain regional limitations Medical images courtesy of : Local Contact Information
of sales rights and service availability, Fremantle Hospital, Fremantle, Australia
we cannot guarantee that all products St. Vincent’s Hospital, Melbourne, Australia in the USA
included in this brochure are available Imaging Science Institute Charité, Berlin, Siemens Medical Solutions USA, Inc.
through the Siemens sales organization Germany 51 Valley Stream Parkway
worldwide. Availability and packaging MR Bremen-Mitte, Bremen, Germany Malvern, PA 19355
may vary by country and is subject to University Hospital Rechts der Isar, Phone : +1 888-826-9702
change without prior notice. Some / All Munich, Germany Phone : +1 610-448-4500
of the features and products described University Hospital Grosshadern, Munich, Fax : +1 610-448-2254
herein may not be available in the United Germany
States. University Hospital, Erlangen, Germany In Japan
All devices listed herein may not be University Hospital, Essen, Germany Siemens-Asahi
licensed according to Canadian Medical University Hospital, Tuebingen, Germany Medical Technologies Ltd.
Devices Regulations. Aarthi Advanced CT + MRI, Chennai, India Takanawa Park Tower 14F
The information in this document con- Krystal Diagnostic, New Delhi, India 20-14, Higashi-Gotanda 3-chome
tains general technical descriptions of Hospital Ca’ Foncello, Treviso, Italy Shinagawa-ku
specifications and options as well as stan- Jikei University Hospital, Tokyo, Japan Tokyo 141-8644
dard and optional features which do not Tokyo Medical University, Tokyo, Japan Phone : +81 3 5423 8411
always have to be present in individual St. Paul’s Hospital, Hongkong, P.R. China
cases. Singapore General Hospital, Singapore, In Asia
Siemens reserves the right to modify the Singapore Siemens Pte Ltd
design, packaging, specifications and Children’s Hospital, Philadelphia, USA Healthcare Sector
options described herein without prior First Hill Diagnostic Imaging, Seattle, USA Regional Headquarters
notice. Please contact your local Siemens Foothills Medical Centre, Calgary, USA The Siemens Center
sales representative for the most current University Hospital NYU, New York, USA 60 MacPherson Road
information. University Hospital UCLA, Los Angeles, Singapore 348615
Note : Any technical data contained in this USA Phone : +65 6490 6000
document may vary within defined toler- Washington Hospital, Washington, USA Fax : +65 6490 6001
ances. Original images always lose a cer-
tain amount of detail when reproduced. Global Business Unit
Siemens AG
Please find fitting accessories : Medical Solutions
www.siemens.com/healthcare-accessories Magnetic Resonance
Henkestr. 127
91052 Erlangen
Germany
Phone : +49 9131 84-0
www.siemens.com/healthcare
Order No. A91MR-500-63-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
T-class. Get ready for a new kind of workflow
www.siemens.com/healthcare
T-class is the next generation of syngo TimCT is built on the highly
trendsetting Tim-based MRI scanners. advanced T-class patient table :
T-class systems enable for the first
time CT-like scanning in MRI with the • High positioning accuracy
Continuous Table move examinations, • RF shielded table drive
syngo TimCT, and support workflow
at the scanner through automated MAGNETOM Tim Systems with T-class
functionalities. feature syngo TimCT FastView. The fast
and efficient Continuous Table move
localizer for large body regions.
syngo TimCT
syngo TimCT FastView
The trendsetting TimCT – Continuous
Table move powered by Tim – opens the syngo TimCT FastView is the “one go”
door to a revolutionary way of scanning – localizer for the whole body or large body
namely from stepping to continuous regions such as the whole spine or the
movement measurements, a world first whole abdomen. It acquires the complete
from Siemens. extended Field of View in one volume
with isotropic resolution. Transverse,
With “MR as simple as CT”, syngo TimCT coronal and sagittal reformats of the vol-
on MAGNETOM T-class systems provides ume are calculated Inline and displayed
a smooth workflow and the most for planning subsequent exams.
homogeneous image quality. The
image quality profits from continuously • Inline reconstruction of the localizer
scanning at the iso-center, the most images during the scan
homogeneous region of the magnet. • Localizing images in the three planes
The seamless scanning of large FoVs over the maximum Field of View
removes boundary artifacts inherent to available for subsequent planning in
stepping techniques. all orientations.
• syngo TimCT FastView can be run
With syngo TimCT no time is lost for without laser light positioning to further
table moves between stations. streamline the workflow
www.siemens.com/healthcare
Order No. A91MR-500-64-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Tim [76 x 32]
SQ-engine
www.siemens.com/healthcare
Tim – Total imaging matrix
Gradients
General
Gradient duty cycle 100 %
Gradient performance for each axis
Max. amplitude 45 mT / m1)
Min. rise time 200 µs from 0 to 40 mT / m
Max. slew rate 200 T / m / s
Vector gradient performance
(vector summation of all 3 gradient axes)
Max. eff. amplitude 72 mT / m
Max. eff. slew rate 346 T / m / s
1) Value is valid for longitudinal direction. Max. amplitude for horizontal and vertical direction :
40 mT / m
Gradient Amplifier
Water-cooled, highly compact, modular design
Ultra-fast solid-state technology with very low switching losses
Max. output voltage2) 2000 V
Max. output current2) 625 A
2) Values for each of the 3 gradient axes
Resolution Parameters
Min. FoV 5 mm
Max. FoV 500 mm
Min. slice thickness 2D 0.1 mm
Max. slice thickness 2D 200 mm
Min. partition thickness 3D 0.05 mm
Max. partition thickness 3D 20 mm
Min. slab thickness 3D 5.4 mm
Max. slab thickness 3D 500 mm
Max. matrix 1024
Highest in-plane resolution 9 µm
www.siemens.com/healthcare
Order No. A91MR-500-65-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Tim [76 x 18]
SQ-engine
www.siemens.com/healthcare
Tim – Total imaging matrix
Gradients
General
Gradient duty cycle 100 %
Gradient performance for each axis
Max. amplitude 45 mT / m1)
Min. rise time 200 µs from 0 to 40 mT / m
Max. slew rate 200 T / m / s
Vector gradient performance
(vector summation of all 3 gradient axes)
Max. eff. amplitude 72 mT / m
Max. eff. slew rate 346 T / m / s
1) Value is valid for longitudinal direction. Max. amplitude for horizontal and vertical direction :
40 mT / m
Gradient Amplifier
Water-cooled, highly compact, modular design
Ultra-fast solid-state technology with very low switching losses
Max. output voltage2) 2000 V
Max. output current2) 625 A
2) Values for each of the 3 gradient axes
Resolution Parameters
Min. FoV 5 mm
Max. FoV 500 mm
Min. slice thickness 2D 0.1 mm
Max. slice thickness 2D 200 mm
Min. partition thickness 3D 0.05 mm
Max. partition thickness 3D 20 mm
Min. slab thickness 3D 5.4 mm
Max. slab thickness 3D 500 mm
Max. matrix 1024
Highest in-plane resolution 9 µm
www.siemens.com/healthcare
Order No. A91MR-500-66-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Tim [76 x 18]
Q-engine
www.siemens.com/healthcare
Tim – Total imaging matrix
Gradients
General
Gradient duty cycle 100 %
Gradient performance for each axis
Max. amplitude 33 mT / m
Min. rise time 264 µs from 0 to 33 mT / m
Max. slew rate 125 T / m / s
Vector gradient performance
(vector summation of all 3 gradient axes)
Max. eff. amplitude 57 mT / m
Max. eff. slew rate 216 T / m / s
Gradient Amplifier
Water-cooled, highly compact, modular design
Ultra-fast solid-state technology with very low switching losses
Max. output voltage1) 1250 V
1)
Max. output current 460 A
1) Values for each of the 3 gradient axes
Resolution Parameters
Min. FoV 5 mm
Max. FoV 500 mm
Min. slice thickness 2D 0.1 mm
Max. slice thickness 2D 200 mm
Min. partition thickness 3D 0.05 mm
Max. partition thickness 3D 20 mm
Min. slab thickness 3D 6.8 mm
Max. slab thickness 3D 500 mm
Max. matrix 1024
Highest in-plane resolution 11 µm
www.siemens.com/healthcare
Order No. A91MR-500-67-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Tim [32 x 8]
Q-engine
www.siemens.com/healthcare
Tim – Total imaging matrix
Gradients
General
Gradient duty cycle 100 %
Gradient performance for each axis
Max. amplitude 33 mT / m
Min. rise time 264 µs from 0 to 33 mT / m
Max. slew rate 125 T / m / s
Vector gradient performance
(vector summation of all 3 gradient axes)
Max. eff. amplitude 57 mT / m
Max. eff. slew rate 216 T / m / s
Gradient Amplifier
Water-cooled, highly compact, modular design
Ultra-fast solid-state technology with very low switching losses
Max. output voltage1) 1250 V
1)
Max. output current 460 A
1) Values for each of the 3 gradient axes
Resolution Parameters
Min. FoV 5 mm
Max. FoV 500 mm
Min. slice thickness 2D 0.1 mm
Max. slice thickness 2D 200 mm
Min. partition thickness 3D 0.05 mm
Max. partition thickness 3D 20 mm
Min. slab thickness 3D 6.8 mm
Max. slab thickness 3D 500 mm
Max. matrix 1024
Highest in-plane resolution 11 µm
www.siemens.com/healthcare
Order No. A91MR-500-68-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Head Matrix Coil
www.siemens.com/healthcare
Head Matrix Coil Applications
• Head examination
General • MR Angiography
• Combined head / neck examination
The Head Matrix coil is part of the • TMJ (temporo mandibular joints)
standard system configuration.
www.siemens.com/healthcare
Order No. A91MR-500-A601-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Neck Matrix Coil
www.siemens.com/healthcare
Neck Matrix Coil Applications
• Cervical Spine
General • Neck
• Larynx / Esophagus
The Neck Matrix coil is part of the • MR Angiography
standard system configuration. • Mediastinum
• Combined head / neck examination
• 4-element design with
4 integrated preamplifiers,
2 clusters of 2 elements each Can be combined with
• Upper coil part removable
• Lower coil part may stay on • Head Matrix coil
the patient table for most of the • Spine Matrix coil
examinations • Body Matrix coils
• Operates in an integrated fashion • Peripheral Angio Matrix coil
with the Head Matrix coil and Spine • All flexible coils
Matrix coil, for coverage of the
posterior and anterior neck region
• No coil tuning Matrix Coil Mode
• iPAT-compatible
• 2-channel CP Mode
• 4-channel Dual Mode
Technical Data
• Weight : 2.6 kg
• Dimensions :
190 mm × 330 mm × 332 mm
(L × W × H)
www.siemens.com/healthcare
Order No. A91MR-500-A602-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Spine Matrix Coil
www.siemens.com/healthcare
Spine Matrix Coil Applications
• 8-channel CP Mode
• 16-channel Dual Mode
• 24-channel Triple Mode
Technical Data
• Weight : 11 kg ;
may remain on the patient
table for almost all exams
• Dimensions :
1185 mm × 485 mm × 33 mm
(L × W × H)
www.siemens.com/healthcare
Order No. A91MR-500-A603-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Body Matrix Coil
www.siemens.com/healthcare
Body Matrix Coil Applications
• 2-channel CP Mode
• 4-channel Dual Mode
• 6-channel Triple Mode
Technical Data
• Weight : 1.5 kg ;
“patient-felt” weight of
coil only 950 g
• Dimensions :
322 mm × 520 mm × 70 mm
(L × W × H)
www.siemens.com/healthcare
Order No. A91MR-500-A604-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Peripheral Angio Matrix Coil
www.siemens.com/healthcare
Peripheral Angio Matrix Coil Applications
• Weight : 5.75 kg
• Dimensions :
970 mm × 300 − 600 mm × 270 mm
(L × W × H)
www.siemens.com/healthcare
Order No. A91MR-500-A605-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Breast Matrix Coil
www.siemens.com/healthcare
Breast Matrix Coil Applications
• 2-channel CP Mode
• 4-channel Dual Mode
Technical Data
• Weight : 7.5 kg
• Dimensions :
500 mm × 520 mm × 135 mm
(L × W × H)
www.siemens.com/healthcare
Order No. A91MR-500-A606-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Loop Flex Coil, large
www.siemens.com/healthcare
Loop Flex Coil, large Applications
• Weight : 400 g
4-Channel Flex Coil Interface • Diameter : 190 mm
General
www.siemens.com/healthcare
Order No. A91MR-500-A608-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Loop Flex Coil, small
www.siemens.com/healthcare
Loop Flex Coil, small Applications
www.siemens.com/healthcare
Order No. A91MR-500-A609-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
4-Channel Flex Coil
www.siemens.com/healthcare
4-Channel Flex Coil Technical Data :
• Weight : 550 g
4-Channel Flex Coil Interface • Dimensions : 516 mm × 224 mm
www.siemens.com/healthcare
Order No. A91MR-500-A610-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Loop Coils
www.siemens.com/healthcare
Loop Coils Applications
www.siemens.com/healthcare
Order No. A91MR-500-A611-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Endorectal Coil
www.siemens.com/healthcare
Endorectal Coil Applications
• Excellent visualization
Flex Coil Interface of the prostate, colon, rectum
and cervix without the risk
• Integrated dual ultra low-noise of invasive procedures
preamplifiers • Non-invasive preoperative
• Allows flexible coil positioning diagnostic evaluation and
• Only one interface necessary treatment planning
for all Flex coils
• Several Flex Coil Interfaces
can be used simultaneously Can be combined with
to connect several Flex coils
• Body Matrix coil
• All additional flexible coils
General (second Flex Coil Interface required)
www.siemens.com/healthcare
Order No. A91MR-500-A612-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Shoulder Array Coil
www.siemens.com/healthcare
Shoulder Array Coil Applications
• Opening : 200 mm
• Weight : 1.6 kg
Base plate
• Dimensions :
445 mm × 490 mm (L × W)
• Weight : approx. 5 kg
www.siemens.com/healthcare
Order No. A91MR-500-A613-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
CP Extremity Coil
www.siemens.com/healthcare
CP Extremity Coil Applications
• Knee
General • Ankle
• Peripheral MR Angiography
• Transmit / receive coil
• CP coil with 2 integrated
preamplifiers Technical Data
• Upper coil part removable
• Holder allows off-center • Weight : 6.5 kg
positioning to keep knee or • Dimensions :
foot which is not under 405 mm × 270 mm × 290 mm
examination in a comfortable (L × W × H)
position
• No coil tuning
www.siemens.com/healthcare
Order No. A91MR-500-A614-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
8-Channel Knee Coil
www.siemens.com/healthcare
8-Channel Knee Coil Applications
www.siemens.com/healthcare
Order No. A91MR-500-A615-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Double Loop Array Coil
www.siemens.com/healthcare
Double Loop Array Coil Applications
• Simultaneous visualization
General of the left and right TMJs
(temporo mandibular joints)
• Circular coil pair with with high resolution
Double-Loop Array Holder • High resolution imaging
• No coil tuning of the eye
• Extra arm rest for wrist imaging • High resolution imaging
• iPAT-compatible of the wrist
Technical Data
• Weight : 1.1 kg
• Dimensions :
82 mm × 135 mm × 82 mm
(L × W × H)
www.siemens.com/healthcare
Order No. A91MR-500-A616-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
CP Head Array Coil
www.siemens.com/healthcare
CP Head Array Coil Applications
• Head examinations
General • Head examinations with utilization
of a stereotactic frame
• CP coil design with 2 integrated • Pediatric imaging
preamplifiers
• Upper coil part removable
• Lower coil part usable without Can be combined with
upper part
• Open patient-friendly design • Body Matrix coil
• Highly homogenous illumination • All flexible coils
• No coil tuning • Double Loop Array coil
• Cushioned head stabilizers
(removable)
• Detachable double mirror Technical Data
• Also compatible with
MAGNETOM Symphony • Weight : 5.7 kg
and Sonata systems • Dimensions :
480 mm × 330 mm (L × W)
www.siemens.com/healthcare
Order No. A91MR-500-A617-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Tx / Rx 15-Channel Knee Coil
www.siemens.com/healthcare
Tx / Rx 15-Channel Knee Coil Applications
www.siemens.com/healthcare
Order No. A91MR-500-A618-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
8-Channel Wrist Coil
www.siemens.com/healthcare
8-Channel Wrist Coil Applications
www.siemens.com/healthcare
Order No. A91MR-500-A619-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
8-Channel Foot-Ankle Coil
www.siemens.com/healthcare
8-Channel Foot-Ankle Coil Applications
www.siemens.com/healthcare
Order No. A91MR-500-A620-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
32-Channel Body Coil
www.siemens.com/healthcare
32-Channel Body Coil Applications
Technical Data
www.siemens.com/healthcare
Order No. A91MR-500-A621-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
4-Channel BI Breast Coil
www.siemens.com/healthcare
4-Channel BI Breast Coil Applications
Technical Data
• Weight :
Coil and frame 11 kg
• Dimensions :
880 mm × 470 mm × 210 mm
(L × W × H)
www.siemens.com/healthcare
Order No. A91MR-500-A622-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
32-Channel Head Coil
www.siemens.com/healthcare
32-Channel Head Coil Applications
www.siemens.com/healthcare
Order No. A91MR-500-A623-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
16-Channel AI Breast Coil
www.siemens.com/healthcare
16-Channel AI Breast Coil Applications
• Frame
• Positioning cushion Can be combined with
• Head rest
• iPAT compatible • Body Matrix coil
• All flexible coils for even more
axillary coverage
Technical Data
• Weight :
Coil and frame 11 kg
• Dimensions :
710 mm × 470 mm × 200 mm
(L × W × H)
www.siemens.com/healthcare
Order No. A91MR-500-A624-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Sentinelle Vanguard for Siemens
www.siemens.com/healthcare
Sentinelle Vanguard for Applications
Siemens
• Simultaneous imaging of both breasts
in all directions
General • Uni- or bi-lateral imaging of the breasts
in sagittal direction
• Patient Frame • Uni-lateral biopsy imaging for lateral
• Immobilization plate and medial access
• Slider • High-resolution 2D and 3D imaging
• Two 3-channel diagnostic insert coils ; • Good iPAT capabilities, iPAT factors
two 1-channel biopsy insert coils ; up to 3
one 2-channel medial coil
• The coil can be used in the following
configurations : Can be combined with
8-channel diagnostic imaging ;
4-channel biopsy (bilateral) ; • Body Matrix coil
2-channel biopsy (unilateral) • All flexible coils for even more
• Breast cushion set axillary coverage
• Height adjustable head rest
• Head rest cushion
• Contralateral support plate for use Technical Data
in all unilateral biopsy
• Weight : 14 kg
• Dimensions :
1097 mm × 582 mm × 279 mm
(L × W × H)
www.siemens.com/healthcare
Order No. A91MR-500-A625-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Tx / Rx CP Head Coil
www.siemens.com/healthcare
Tx / Rx CP Head Coil Applications
• Head examinations
General • High resolution brain
spectroscopy
• CP Send / Receive head coil
with integrated preamplifier
• Upper coil part removable Technical Data
• Open patient-friendly design
• No coil tuning • Weight : 5.2 kg
• Cushions for patient comfort and • Dimensions :
stabilization of the head 315 mm × 475 mm × 360 mm
• Detachable mirror (L × W × H)
www.siemens.com/healthcare
Order No. A91MR-500-A626-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Application Packages
I-class. It's all about Innovations.
www.siemens.com/healthcare
Tim Whole Body Suite syngo Security
2
Tim Planning Suite syngo MapIt
Easy planning of extended Field of View syngo MapIt allows the early detection of
examinations in an efficient way using osteo arthritic pathology based on the T1
Set-n-Go protocols. and T2 and T2* properties of the carti-
lage. As well the assessment of T1, T2
It allows planning of several stations at and T2* properties of tissues in other
once e.g. on composed localizer images. body regions is possible.
The overlap of slice groups can be
adjusted. All stations can have indepen- syngo MapIt provides the Inline calcula-
dent parameter settings although they tion of parametric maps for the
are displayed together. T1, T2 and T2* properties of the imaged
tissue and the necessary measurements.
A special coupling mode allows easy
positioning of all stations at once accord- • 3D VIBE sequence for Inline T1 mapping
ing to the patient’s anatomy. • Multiecho spin echo sequence for Inline
T2 mapping
Fully supports scan@center and Phoenix • Multiecho gradient echo sequence for
functionality. Inline T2* mapping
• Protocols for fully automated Inline
• Tim Planning UI with optimized layout parametric mapping
for slice positioning
• Ready to use Set-n-Go protocols for
different clinical questions
• Integrated toolbar for fast advanced
slice planning : FoV-Plus, FoV-Minus,
AlignParallel, AlignFieldOfViews
3
syngo SWI (Susceptibility
Weighted Imaging)
Siemens-unique sequence technique
for Susceptibility Weighted Imaging
4
AutoAlign Head Landmark
Survey (LS)
Automated positioning and alignment of
the anatomy-related sagittal, coronal and
axial localizer slices using anatomical
landmarks. Independent of patient age,
head position, disease or user selected
positioning standards, the system auto-
matically finds the correct position.
AutoAlign Head LS is independent of
the coil setup or the sequence.
AutoAlign Spine
AutoAlign Knee
5
Advanced Cardiac Ventricular function and
regional wall motion evaluation
This package contains special sequences with syngo BEAT
and protocols for advanced cardiac imag-
ing including 3D and 4D syngo BEAT • Retrospectively triggered TrueFISP with
functionalities. It allows comprehensive iPAT for full coverage of the cardiac cycle
exams covering morphology, function, • T-PAT with GRAPPA for highly accelerated
dynamic imaging, tissue characterization, image acquisition.
coronary imaging, plaque characteriza- • Arrythmia rejection for patients with
tion and more. extrasystoles.
• 3D cine imaging, complete coverage of
This package includes, for example : the heart in just one go
• Real-time cine TrueFISP imaging with
iPAT : no need for ECG triggering or
syngo BEAT breath-hold commands, thus beneficial
in patients with arrhythmia or breath-
• Unique tool for fast and easy cardiovas- holding difficulties
cular MR imaging • Real-time radial imaging for high speed
• 1-click change from FLASH to TrueFISP and high-resolution cine studies
for easy contrast optimization • Visualization of myocardial contractility
• 1-click to switch arrhythmia rejection using various tagging techniques
on/off
• 1-click change from Cartesian to radial
sampling to increase effective image Cardiac and vessel morphology
resolution (e.g. in pediatric patients)
and avoid folding artifacts in large • High resolution morphological imaging
patients using bright- and dark-blood sequences
• 1-click switch from cine imaging to tag- with free breathing
ging for wall motion evaluation • Multiple contrasts such as T1- and
• 1-click switch from 2D to 3D imaging T2-weighted imaging for use in diseases
• syngo BEAT automatically adjusts all such as myocarditis (inflammation /
parameters associated with the changes hyperaemia), ARVD (fibrous-fetty
degeneration) or acute myocardial
infarction (edema)
6
Tissue characterization with
syngo BEAT
7
TGSE (Turbo Gradient
Spin Echo)
Ultra-fast sequence providing high
resolution imaging or extremely short
acquisition times
Inline Diffusion
Inline Perfusion
8
Inline BOLD Imaging (Blood
Oxygen Level Dependent)
Examination of intrinsic susceptibility
changes in different areas of the brain,
induced by external stimulation (e.g.
motor or visual)
Inline Composing
9
3D PACE
10
syngo ASL Diffusion Tensor Imaging (DTI)
(Arterial Spin Labeling)
Acquisition of data sets with multi-direc-
Arterial Spin Labeling (ASL) is an MR tech- tional diffusion weighting to assess aniso-
nique using the water in arterial blood as tropic diffusion properties of brain tissue
an endogenous contrast agent to evalu-
ate perfusion non-invasively. syngo ASL • Measurement of up to 256 directions
provides unique insight into human brain of diffusion weighting with up to
perfusion and function physiology by 16 different b-values
evaluating cerebral blood flow. syngo ASL • Inline calculation of the diffusion tensor
is capable of high spatial resolution perfu- • Inline calculation of Fractional Aniso-
sion imaging, making the technique very tropy (FA) maps (grey-value as well as
appealing in the evaluation of stroke, color-coded for principle diffusion direc-
tumors, degenerative diseases, epilepsy tion), Apparent Diffusion Coefficient
but also in basic neuroscience, e.g. for (ADC) maps and trace-weighted images
studies of functional CBF changes. based on the tensor
Prerequisites :
11
syngo DTI Tractography Single Voxel Spectroscopy
syngo DTI Tractography allows the visual- Integrated software package with
ization of multiple white matter tracts sequences and protocols for proton
based on diffusion tensor imaging data. spectroscopy. Streamlined for easy
DTI Tractography is optimized to support push-button operation
the presurgical planning and to allow for
neuro physiological research with respect • Matrix Spectroscopy – phase-coherent
to connectivity and white matter patho- signal combination from several coil
logy. elements for maximum SNR based on
the head matrix coil
• Advanced 3D visualization of white • Spectral suppression (user definable
matter tracts in the context of 2D or 3D parameter) to avoid lipid superposition
anatomical and DTI datasets in order to reliably detect e.g. choline in
• Texture Diffusion, a highly versatile the breast
in-plane visualization of white matter • Up to 8 regional saturation (RSat) bands
tracts, allows to display and read DTI for outer volume suppression can be
Tractography results on PACS reading defined by the user.
stations and in the OR. • Physiological triggering (ECG, pulse,
• Seed points for tracking with single ROI respiratory or external trigger) in order
and with multiple ROIs to assess connec- to avoid e.g. breathing artefacts.
tivity
• Tract and seeding ROI statistics Clinical application :
(mean / max FA value, min / mean / max
ADC value, and more) • Brain, liver, neck soft tissue, spine
• DICOM export of views, HTML export
of Tract and seeding ROI statistics
• Interactive QuickTracking displays SVS techniques SE and STEAM
the tract originating from the mouse
pointer position while moving over • Short TEs available
the DTI data set. • Fully automated adjustments including
localized shimming and adjustment of
water suppression pulses
• Also available : Interactive adjustments
and control of adjustments
• Optimized protocols for brain applica-
tions
12
syngo GRACE (GeneRAlized Multinuclear Support
breast speCtroscopy Exam)
Integrated hardware and system software
SVS (Single Voxel Spectroscopy) tech- package to prepare the MAGNETOM
nique (spin echo sequence) optimized for system for imaging and spectroscopy with
breast spectroscopy. nuclei other than 1H.
• The technique contains a special spec- Coils, pre-amplifiers and optimized pulse
tral lipid suppression pulse (user defin- sequences are not included.
able) for lipid signal reduction.
• Siemens unique water reference • Supports the generation of RF pulses for
3
detection to visualize the normalized He, 7Li, 13C, 19F, 23Na, 31P and 129Xe and
choline ratio allows to receive signals at the respec-
• Online frequency shift correction for tive frequencies
reduction of breathing related artifacts, • Supports mono and double resonant
inline implementation, no additional send / receive coils (1H / x-nucleus)
user interaction is required. • Imaging with the nuclei 3He, 7Li, 13C,
19 23
F, Na, 31P and 129Xe and spectros-
Clinical applications: copy with the nuclei 7Li, 13C, 19F, and 31P
• Spectroscopic and imaging experiments
• syngo GRACE may assist the physician using the 1H Nuclear Overhauser Effect
to improve the specificity of tumor (NOE) and using 1H decoupling
diagnoses • A basic pulse sequence serves as a start-
• syngo GRACE aids in evaluating the ing point for flexible design of x-nucleus
response to neoadjuvant chemotherapy sequences using the development envi-
ronment IDEA (see below) Multinuclear Spectroscopy
The Siemens Breast Matrix coil, the
16-channel AI Breast coil and the CSI spectroscopy sequence and protocols
2-, 4-, 8-channel Sentinelle coils are for x-nuclei
recommended to obtain best spectral
quality. • The CSI sequence supports measure-
ments with all frequencies supported
by the hardware
• For 31P spectroscopy at 1.5T dedicated
applications including measurement
and post-processing protocols are
included for heart, liver and muscle
• Basic measurement and post-process-
ing protocols for 7Li, 13C, 19F and 31P
• The sequence supports NOE (Nuclear
Overhauser Effect) and 1H decoupling
• ECG triggering available
• Weighted acquisition available
13
syngo CSI 2D : Chemical Shift syngo CSI 3D : Chemical Shift
Imaging Imaging
Integrated software package with Integrated software package with
sequences and protocols for Chemical sequences and protocols for Chemical
Shift Imaging (CSI). Shift Imaging (CSI).
Extension of the SVS package, offering Extension of the SVS package, offering
the same level of user-friendliness and the same level of user-friendliness and
automation. automation.
Advanced High Order Shim Option required Advanced High Order Shim Option required
14
IDEA Integrated Development syngo Expert-i
Environment for Applications
Interactive remote assistance during the
Extensive programming environment MR exam. Get real-time access to imaging
used to create and modify pulse data and exam information from any net-
sequences, offering a maximum of worked PC within the hospital network.
flexibility.
Until now, radiologists or other experts
Based on C++ for Windows XP. had to stop what they were doing and
go to the MR scanner when complex
Sequences and RF pulses are displayed clinical questions arose.
in a visual interface.
Now, questions can be addressed quickly
• Allows direct access to the Image and efficiently via networked PC.
Calculation Environment (ICE), and
to all protocols Some of the benefits of syngo Expert-i
• Testing the generated code is exten- are :
sively supported by the debugger and
the simulation program • Excellent results right from the first
• IDEA is also usable on any standard PC examination
with operating system Windows XP • Streamlined workflow & faster patient
making developments independent of throughput
the MR system • Reduces repeat rates with a check on
images while the patient is still in the
examination room
Processing Plug-ins • Reduces training effort by enabling
expert assistance for specialized
For development or modification of user- procedure
defined image processing steps which
may be integrated into the measurement
protocols.
Prerequisite :
IDEA training course
15
On account of certain regional limitations Medical images courtesy of : Local Contact Information
of sales rights and service availability, SKG Radiology Murdoch, Australia
we cannot guarantee that all products St. Vincent’s Hospital, Melbourne, in the USA
included in this brochure are available Australia Siemens Medical Solutions USA, Inc.
through the Siemens sales organization DKD, Wiesbaden, Germany 51 Valley Stream Parkway
worldwide. Availability and packaging MR Bremen-Mitte, Bremen, Germany Malvern, PA 19355
may vary by country and is subject to University Hospital Rechts der Isar, Phone : +1 888-826-9702
change without prior notice. Some / All Munich, Germany Phone : +1 610-448-4500
of the features and products described University Hospital Grosshadern, Fax : +1 610-448-2254
herein may not be available in the United Munich, Germany
States. Praxis Loebau, Loebau, Germany In Japan
All devices listed herein may not be University Hospital NYU, New York, USA Siemens-Asahi
licensed according to Canadian Medical University Hospital UCLA, Los Angeles, USA Medical Technologies Ltd.
Devices Regulations. Takanawa Park Tower 14F
The information in this document con- 20-14, Higashi-Gotanda 3-chome
tains general technical descriptions of Shinagawa-ku
specifications and options as well as stan- Tokyo 141-8644
dard and optional features which do not Phone : +81 3 5423 8411
always have to be present in individual
cases. In Asia
Siemens reserves the right to modify the Siemens Pte Ltd
design, packaging, specifications and Healthcare Sector
options described herein without prior Regional Headquarters
notice. Please contact your local Siemens The Siemens Center
sales representative for the most current 60 MacPherson Road
information. Singapore 348615
Note : Any technical data contained in this Phone : +65 6490 6000
document may vary within defined toler- Fax : +65 6490 6001
ances. Original images always lose a cer-
tain amount of detail when reproduced. Global Business Unit
Siemens AG
Please find fitting accessories : Medical Solutions
www.siemens.com/healthcare-accessories Magnetic Resonance
Henkestr. 127
91052 Erlangen
Germany
Phone : +49 9131 84-0
www.siemens.com/healthcare
Order No. A91MR-500-B6-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Application Packages
T-class. Trendsetting applications. Powered by Tim.
www.siemens.com/healthcare
T-class is the next generation of TGSE (Turbo Gradient
trendsetting Tim-based MRI scanners. Spin Echo)
T-class systems enable for the first
time CT-like scanning in MRI with the Ultra-fast sequence providing high
Continuous Table move examinations, resolution imaging or extremely short
syngo TimCT, and support workflow acquisition times
at the scanner through automated
functionalities. Hybrid Turbo Spin Echo / Gradient Echo
used primarily for T2-weighted imaging
2
syngo MapIt
3
syngo SWI (Susceptibility
Weighted Imaging)
Siemens-unique sequence technique for
Susceptibility Weighted Imaging
4
AutoAlign Head Landmark
Survey (LS)
Automated positioning and alignment of
the anatomy-related sagittal, coronal and
axial localizer slices using anatomical
landmarks. Independent of patient age,
head position, disease or user selected
positioning standards, the system auto-
matically finds the correct position.
AutoAlign Head LS is independent of
the coil setup or the sequence.
AutoAlign Spine
AutoAlign Knee
5
Advanced Cardiac Ventricular function and
regional wall motion evaluation
This package contains special sequences with syngo BEAT
and protocols for advanced cardiac imag-
ing including 3D and 4D syngo BEAT • Retrospectively triggered TrueFISP with
functionalities. It allows comprehensive iPAT for full coverage of the cardiac cycle
exams covering morphology, function, • T-PAT with GRAPPA for highly accelerated
dynamic imaging, tissue characterization, image acquisition.
coronary imaging, plaque characteriza- • Arrythmia rejection for patients with
tion and more. extrasystoles.
• 3D cine imaging, complete coverage of
This package includes, for example : the heart in just one go
• Real-time cine TrueFISP imaging with
iPAT : no need for ECG triggering or
syngo BEAT breath-hold commands, thus beneficial
in patients with arrhythmia or breath-
• Unique tool for fast and easy cardiovas- holding difficulties
cular MR imaging • Real-time radial imaging for high speed
• 1-click change from FLASH to TrueFISP and high-resolution cine studies
for easy contrast optimization • Visualization of myocardial contractility
• 1-click to switch arrhythmia rejection using various tagging techniques
on/off
• 1-click change from Cartesian to radial
sampling to increase effective image Cardiac and vessel morphology
resolution (e.g. in pediatric patients)
and avoid folding artifacts in large • High resolution morphological imaging
patients using bright- and dark-blood sequences
• 1-click switch from cine imaging to tag- with free breathing
ging for wall motion evaluation • Multiple contrasts such as T1- and
• 1-click switch from 2D to 3D imaging T2-weighted imaging for use in diseases
• syngo BEAT automatically adjusts all such as myocarditis (inflammation /
parameters associated with the changes hyperaemia), ARVD (fibrous-fetty
degeneration) or acute myocardial
infarction (edema)
6
Tissue characterization with
syngo BEAT
7
Inline BOLD Imaging (Blood
Oxygen Level Dependent)
Examination of intrinsic susceptibility
changes in different areas of the brain,
induced by external stimulation (e.g.
motor or visual)
Inline Composing
8
3D PACE
9
syngo ASL Diffusion Tensor Imaging (DTI)
(Arterial Spin Labeling)
Acquisition of data sets with multi-direc-
Arterial Spin Labeling (ASL) is an MR tech- tional diffusion weighting to assess aniso-
nique using the water in arterial blood as tropic diffusion properties of brain tissue
an endogenous contrast agent to evalu-
ate perfusion non-invasively. syngo ASL • Measurement of up to 256 directions
provides unique insight into human brain of diffusion weighting with up to
perfusion and function physiology by 16 different b-values
evaluating cerebral blood flow. syngo ASL • Inline calculation of the diffusion tensor
is capable of high spatial resolution perfu- • Inline calculation of Fractional Aniso-
sion imaging, making the technique very tropy (FA) maps (grey-value as well as
appealing in the evaluation of stroke, color-coded for principle diffusion direc-
tumors, degenerative diseases, epilepsy tion), Apparent Diffusion Coefficient
but also in basic neuroscience, e.g. for (ADC) maps and trace-weighted images
studies of functional CBF changes. based on the tensor
Prerequisites :
10
syngo DTI Tractography Single Voxel Spectroscopy
syngo DTI Tractography allows the visual- Integrated software package with
ization of multiple white matter tracts sequences and protocols for proton
based on diffusion tensor imaging data. spectroscopy. Streamlined for easy
DTI Tractography is optimized to support push-button operation
the presurgical planning and to allow for
neuro physiological research with respect • Matrix Spectroscopy – phase-coherent
to connectivity and white matter patho- signal combination from several coil
logy. elements for maximum SNR based on
the head matrix coil
• Advanced 3D visualization of white • Spectral suppression (user definable
matter tracts in the context of 2D or 3D parameter) to avoid lipid superposition
anatomical and DTI datasets in order to reliably detect e.g.choline in
• Texture Diffusion, a highly versatile the breast
in-plane visualization of white matter • Up to 8 regional saturation (RSat) bands
tracts, allows to display and read DTI for outer volume suppression can be
Tractography results on PACS reading defined by the user.
stations and in the OR. • Physiological triggering (ECG, pulse,
• Seed points for tracking with single ROI respiratory or external trigger) in order
and with multiple ROIs to assess connec- to avoid e.g. breathing artefacts.
tivity
• Tract and seeding ROI statistics Clinical application :
(mean / max FA value, min / mean / max
ADC value, and more) • Brain, liver, neck soft tissue, spine
• DICOM export of views, HTML export
of Tract and seeding ROI statistics
• Interactive QuickTracking displays SVS techniques SE and STEAM
the tract originating from the mouse
pointer position while moving over • Short TEs available
the DTI data set. • Fully automated adjustments including
localized shimming and adjustment of
water suppression pulses
• Also available : Interactive adjustments
and control of adjustments
• Optimized protocols for brain applica-
tions
11
syngo GRACE (GeneRAlized Multinuclear Support
breast speCtroscopy Exam)
Integrated hardware and system software
SVS (Single Voxel Spectroscopy) tech- package to prepare the MAGNETOM
nique (spin echo sequence) optimized for system for imaging and spectroscopy with
breast spectroscopy. nuclei other than 1H.
• The technique contains a special spec- Coils, pre-amplifiers and optimized pulse
tral lipid suppression pulse (user defin- sequences are not included.
able) for lipid signal reduction.
• Siemens unique water reference • Supports the generation of RF pulses for
3
detection to visualize the normalized He, 7Li, 13C, 19F, 23Na, 31P and 129Xe and
choline ratio allows to receive signals at the respec-
• Online frequency shift correction for tive frequencies
reduction of breathing related artifacts, • Supports mono and double resonant
inline implementation, no additional send / receive coils (1H / x-nucleus)
user interaction is required. • Imaging with the nuclei 3He, 7Li, 13C,
19 23
F, Na, 31P and 129Xe and spectros-
Clinical applications: copy with the nuclei 7Li, 13C, 19F, and 31P
• Spectroscopic and imaging experiments
• syngo GRACE may assist the physician using the 1H Nuclear Overhauser Effect
to improve the specificity of tumor (NOE) and using 1H decoupling
diagnoses • A basic pulse sequence serves as a start-
• syngo GRACE aids in evaluating the ing point for flexible design of x-nucleus
response to neoadjuvant chemotherapy sequences using the development envi-
ronment IDEA (see below) Multinuclear Spectroscopy
The Siemens Breast Matrix coil, the
16-channel AI Breast coil and the CSI spectroscopy sequence and protocols
2-, 4-, 8-channel Sentinelle coils are for x-nuclei
recommended to obtain best spectral
quality. • The CSI sequence supports measure-
ments with all frequencies supported
by the hardware
• For 31P spectroscopy at 1.5T dedicated
applications including measurement
and post-processing protocols are
included for heart, liver and muscle
• Basic measurement and post-process-
ing protocols for 7Li, 13C, 19F and 31P
• The sequence supports NOE (Nuclear
Overhauser Effect) and 1H decoupling
• ECG triggering available
• Weighted acquisition available
12
syngo CSI 2D : Chemical Shift syngo CSI 3D : Chemical Shift
Imaging Imaging
Integrated software package with Integrated software package with
sequences and protocols for Chemical sequences and protocols for Chemical
Shift Imaging (CSI). Shift Imaging (CSI).
Extension of the SVS package, offering Extension of the SVS package, offering
the same level of user-friendliness and the same level of user-friendliness and
automation. automation.
Advanced High Order Shim Option required Advanced High Order Shim Option required
13
syngo TimCT Oncology
14
IDEA Integrated Development syngo Expert-i
Environment for Applications
Interactive remote assistance during the
Extensive programming environment MR exam. Get real-time access to imaging
used to create and modify pulse data and exam information from any net-
sequences, offering a maximum of worked PC within the hospital network.
flexibility.
Until now, radiologists or other experts
Based on C++ for Windows XP. had to stop what they were doing and
go to the MR scanner when complex
Sequences and RF pulses are displayed clinical questions arose.
in a visual interface.
Now, questions can be addressed quickly
• Allows direct access to the Image and efficiently via networked PC.
Calculation Environment (ICE), and
to all protocols Some of the benefits of syngo Expert-i are:
• Testing the generated code is exten-
sively supported by the debugger and • Excellent results right from the first
the simulation program examination
• IDEA is also usable on any standard PC • Streamlined workflow & faster patient
with operating system Windows XP throughput
making developments independent of • Reduces repeat rates with a check on
the MR system images while the patient is still in the
examination room
• Reduces training effort by enabling
Processing Plug-ins expert assistance for specialized
procedure
For development or modification of user-
defined image processing steps which
may be integrated into the measurement
protocols.
Prerequisite :
IDEA training course
15
On account of certain regional limitations Medical images courtesy of : Local Contact Information
of sales rights and service availability, SKG Radiology Murdoch, Australia
we cannot guarantee that all products St. Vincent’s Hospital, Melbourne, in the USA
included in this brochure are available Australia Siemens Medical Solutions USA, Inc.
through the Siemens sales organization DKD, Wiesbaden, Germany 51 Valley Stream Parkway
worldwide. Availability and packaging MR Bremen-Mitte, Bremen, Germany Malvern, PA 19355
may vary by country and is subject to University Hospital Rechts der Isar, Phone : +1 888-826-9702
change without prior notice. Some / All Munich, Germany Phone : +1 610-448-4500
of the features and products described University Hospital Grosshadern, Fax : +1 610-448-2254
herein may not be available in the United Munich, Germany
States. Praxis Loebau, Loebau, Germany In Japan
All devices listed herein may not be University Hospital NYU, New York, USA Siemens-Asahi
licensed according to Canadian Medical University Hospital UCLA, Los Angeles, USA Medical Technologies Ltd.
Devices Regulations. Takanawa Park Tower 14F
The information in this document con- 20-14, Higashi-Gotanda 3-chome
tains general technical descriptions of Shinagawa-ku
specifications and options as well as stan- Tokyo 141-8644
dard and optional features which do not Phone : +81 3 5423 8411
always have to be present in individual
cases. In Asia
Siemens reserves the right to modify the Siemens Pte Ltd
design, packaging, specifications and Healthcare Sector
options described herein without prior Regional Headquarters
notice. Please contact your local Siemens The Siemens Center
sales representative for the most current 60 MacPherson Road
information. Singapore 348615
Note : Any technical data contained in this Phone : +65 6490 6000
document may vary within defined toler- Fax : +65 6490 6001
ances. Original images always lose a cer-
tain amount of detail when reproduced. Global Business Unit
Siemens AG
Please find fitting accessories : Medical Solutions
www.siemens.com/healthcare-accessories Magnetic Resonance
Henkestr. 127
91052 Erlangen
Germany
Phone : +49 9131 84-0
www.siemens.com/healthcare
Order No. A91MR-500-C6-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
syngo Chorus MR
www.siemens.com/healthcare
syngo Chorus MR
The workflow in radiology requires the tions at the Radiology Information System Centralized services for protocol update
connectivity and interoperability of differ- (RIS), thus eliminating exam planning and protocol distribution ensure defined
ent systems. In order to reach a smooth efforts at the scanner. high-quality scanning results across MR
and integrated workflow of these sys- The follow-up examination workflow is scanners.
tems, Siemens Healthcare Sector provides systematically supported to reproduce
a solution for setting up MRI examina- examination results for comparison.
Protocol Planning
Inline-Follow up
RIS
PACS
(syngo workflow)
Protocol Distribution
www.siemens.com/healthcare
Order No. A91MR-500-D6-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Post-processing Packages
www.siemens.com/healthcare
All post-processing packages are sepa-
rately available for the syngo Acquisition
Workplace or the syngo MR Workplace
2
Argus Flow
3
Vessel View
4
Composing*
Fly Through
5
syngo BOLD 3D Evaluation
6
Functional and anatomical image data
can be exported for surgical planning as
DICOM datasets, additionally all color
fused images and results can be stored or
printed
7
Neuro Perfusion Evaluation
8
DTI Evaluation
9
syngo DTI Tractography
10
Image Fusion
11
syngo Tissue 4D
Visualization features
Additional visualization of 2D or
3D morphological dataset.
12
Post-processing features :
Pharmacokinetic model
13
Spectroscopy Evaluation
14
Soft Tissue Motion Correction
15
On account of certain regional limitations Medical images courtesy of : Local Contact Information
of sales rights and service availability, Imaging Science Institute Charité, Berlin,
we cannot guarantee that all products Germany in the USA
included in this brochure are available Hospital Ca’ Foncello, Treviso, Italy Siemens Medical Solutions USA, Inc.
through the Siemens sales organization 51 Valley Stream Parkway
worldwide. Availability and packaging Malvern, PA 19355
may vary by country and is subject to Phone : +1 888-826-9702
change without prior notice. Some / All Phone : +1 610-448-4500
of the features and products described Fax : +1 610-448-2254
herein may not be available in the United
States. In Japan
All devices listed herein may not be Siemens-Asahi
licensed according to Canadian Medical Medical Technologies Ltd.
Devices Regulations. Takanawa Park Tower 14F
The information in this document con- 20-14, Higashi-Gotanda 3-chome
tains general technical descriptions of Shinagawa-ku
specifications and options as well as stan- Tokyo 141-8644
dard and optional features which do not Phone : +81 3 5423 8411
always have to be present in individual
cases. In Asia
Siemens reserves the right to modify the Siemens Pte Ltd
design, packaging, specifications and Healthcare Sector
options described herein without prior Regional Headquarters
notice. Please contact your local Siemens The Siemens Center
sales representative for the most current 60 MacPherson Road
information. Singapore 348615
Note : Any technical data contained in this Phone : +65 6490 6000
document may vary within defined toler- Fax : +65 6490 6001
ances. Original images always lose a cer-
tain amount of detail when reproduced. Global Business Unit
Siemens AG
Please find fitting accessories : Medical Solutions
www.siemens.com/healthcare-accessories Magnetic Resonance
Henkestr. 127
91052 Erlangen
Germany
Phone : +49 9131 84-0
www.siemens.com/healthcare
Order No. A91MR-500-E6-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Parts & Accessories
www.siemens.com/healthcare
Patient Video Monitoring In-Room syngo Acquisition Prerequisites :
Workplace
Special video camera integrated in the • Loop Flex coil, large
back magnet cover for observing the Operation and evaluation Workplace, • Breast Biopsy Software
patient. placed in the examination room close to
the patient. Operates in parallel to the
Color 640 × 480 pixel LCD monitor may be syngo Acquisition Workplace.
Removable Patient Table
positioned at the syngo Acquisition
Workplace or at a convenient wall loca- • MR-compatible trackball as input device
and Trolley
tion. • Moveable, height-adjustable Workplace
trolley with connection cable Enables patient positioning and prepara-
tion outside the examination room.
High resolution LCD monitor :
Remote Viewing Monitor
• Max. patient weight – 200 kg (440 lbs)
• Screen size (diagonal) – 46 cm (18”) • Precise docking mechanism with auto-
Color LCD monitor (1280×1024) to be • Screen matrix – 1280 × 1024 matic electronic interlock
connected in parallel to the Workplace • The trolley is adjustable for height and
monitor. has integrated controls for the table
movement of the system
Workplace Table
• Data transfer via fiber optic cables for
high signal quality over a long distance
• Max. distance from Workplace – 150 m Ergonomically designed table for :
Second Removable Tabletop
(492 feet)
• Color monitor
and Trolley
• Keyboard
• Mouse Enables preparation and positioning of
Third Tableside Control Unit
• Patient communication unit the next patient on the trolley outside the
• Patient supervision display examination room while the current
Additional tableside control unit, e.g. for patient is being scanned.
interventional procedures. Located at the
rear end of the system. • Prerequisite : Removable patient table
Advanced High Order Shim
and trolley
System • Max. patient weight – 200 kg (440 lbs)
syngo MR Workplace
Additional 5 channel non-linear 2nd order
electronic shim system, including 32 coils.
PMU Examination Room Display
Additional integrated Workplace with
host computer for post-processing and For optimizing higher order field terms
image evaluation. and fine-tuning homogeneity once the LCD monitor mounted on the magnet
patient is positioned. cover for display of physiological signals
• Same user interface as the syngo in the examination room.
Acquisition Workplace, except for
scan control. • Provides for the display of the 2 ECG-
Breast Biopsy Device
• Shared database with syngo Acquisition channels I and aVF, for optimal signal
Workplace, therefore eliminating image quality, pulse signal, respiratory signal
copy time • Used to perform biopsy of a lesion seen and external trigger input
in MR images
• Used to mark the lesion seen in MR with
Host Computer (syngo MR Workplace) a wire
Technical Data : • Includes compression device, spacer,
aiming device, needle holder, holder for
> Refer to appendix “Computer biopsy gun, pads and cushions
System”
Comfort Kit
www.siemens.com/healthcare
Order No. A91MR-500-F6-7600 | Printed in Germany | MC.MR-00500 PA 0910 POD | © 09.2010, Siemens AG
MAGNETOM Avanto
Computer System
www.siemens.com/healthcare
Host Computer
(syngo Acquisition Workplace) Processor 1 × Intel® Xeon® Quad-Core
Clock rate ≥ 2.66 GHz
Main memory (RAM) 6 GB
st
1 hard disk (system SW) 300 GB
nd
2 hard disk (data base) 300 GB
rd
3 hard disk (images) 300 GB
(approx. 110 000 images, square
matrix 2562 and 5122 uncompressed)
CD-R writer approx. 4000 images 2562 ;
DICOM Standard, ISO 9660
DVD-R writer approx. 25 000 images 2562 ;
DICOM Standard, ISO 9660
Media drives CD / DVD drive
Color LCD monitor Screen matrix 1280 × 1024 pixels
MCPro X Image Processor
Processor ≥ 1 × Intel® Xeon® Quad-Core
Clock rate ≥ 2.33 GHz
Main memory (RAM) ≥ 8 GB
1 hard disk (system SW) 146 GB
4 hard disks (raw data) 2 × 146 GB
Reconstruction speed ≥ 7324 recons per second
(2562 FFT, full FoV)
≥ 27 776 recons per second
(2562 FFT, 25 % recFoV)
Parallel Scan & Recon Simultaneous scan and reconstruction
of up to 8 data sets
Media drives CD / DVD drive
syngo MR Workplace
(optional) Processor 1 × Intel® Xeon® Quad-Core
Clock rate ≥ 2.66 GHz
Main memory (RAM) 6 GB
1st hard disk (system SW) 300 GB
2nd hard disk (images) 300 GB
CD-R writer approx. 4000 images 2562 ;
DICOM Standard, ISO 9660
DVD-R writer approx. 25 000 images 2562 ;
DICOM Standard, ISO 9660
Media drives CD / DVD drive
Color LCD monitor Screen matrix 1280 × 1024 pixels
On account of certain regional limitations Local Contact Information
of sales rights and service availability,
we cannot guarantee that all products in the USA
included in this brochure are available Siemens Medical Solutions USA, Inc.
through the Siemens sales organization 51 Valley Stream Parkway
worldwide. Availability and packaging Malvern, PA 19355
may vary by country and is subject to Phone : +1 888-826-9702
change without prior notice. Some / All Phone : +1 610-448-4500
of the features and products described Fax : +1 610-448-2254
herein may not be available in the United
States. In Japan
All devices listed herein may not be Siemens-Asahi
licensed according to Canadian Medical Medical Technologies Ltd.
Devices Regulations. Takanawa Park Tower 14F
The information in this document con- 20-14, Higashi-Gotanda 3-chome
tains general technical descriptions of Shinagawa-ku
specifications and options as well as stan- Tokyo 141-8644
dard and optional features which do not Phone : +81 3 5423 8411
always have to be present in individual
cases. In Asia
Siemens reserves the right to modify the Siemens Pte Ltd
design, packaging, specifications and Healthcare Sector
options described herein without prior Regional Headquarters
notice. Please contact your local Siemens The Siemens Center
sales representative for the most current 60 MacPherson Road
information. Singapore 348615
Note : Any technical data contained in this Phone : +65 6490 6000
document may vary within defined toler- Fax : +65 6490 6001
ances. Original images always lose a cer-
tain amount of detail when reproduced. Global Business Unit
Siemens AG
Please find fitting accessories : Medical Solutions
www.siemens.com/healthcare-accessories Magnetic Resonance
Henkestr. 127
91052 Erlangen
Germany
Phone : +49 9131 84-0
www.siemens.com/healthcare
Order No. A91MR-500-G6-7600 | Printed in Germany | MC.MR-00500 PA 1111 POD | © 11.2011, Siemens AG
MAGNETOM Avanto Sales Project / Customer
Datasheet-Box Content
www.siemens.com/healthcare
Order No. A91MR-500-60-7600 | Printed in Germany | MC.MR-00500 PA 1111 POD | © 11.2011, Siemens AG