28 NB PULSE JET SOLENOID VALVE
TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE
NC 1
24108 0.5 - 8.5 bar
24108ET 0.5 - 8.5 bar
2
FEATURES
• Hytrel Diaphragm
• Larger exhaust area protected with silencer for
reducing noise
• Solenoid capable of turning 360º
WETTED PARTS
Code B12
Body and Aluminium SS 316
Internals Die Cast Cast
Guide Assembly SS 304
Shadow-Ring Copper
Plunger, Insert SS 430
Diaphragm Hytrel, Viton, NBR
Fasteners SS 304
Seat, Seals NBR, Viton, PTFE
SPECIFICATION IN
FLOW FACTOR
SIZE 3/4” 1”
(kv) Ipm 280 310 SPARES (Refer page 25 for ordering code)
RESPONSE TIME 30 ms SPARE KIT CODE
MINIMUM ELECTRICAL PULSE 50 ms
Diaphragm Kit : Diaphragm Kit 100
AMBIENT TEMPERATURE Seal Kit : Oring Set, Diaphragm Kit,
98
-5 ºC to 85 ºC
Plunger Assembly
Repair Kit : Oring Set, Diaphragm Kit,
Plunger Assembly, Fastener, Springs,
99
11
Silencer, Guide Assembly
FLUID TEMPERATURE
Solenoid Kit : Solenoid, Gasket and Nut 34
-5 ºC to 85 ºC
SPECIAL VERSIONS AND SUFFIX APPROVAL
Suffix : (Valve) AM
TYPE 4X, 6P
Ex ia IIC T6
or T5 or T6
Ex d IIC T4
Special versions : (Solenoid) CO, FR, SS
Approval
DGMS
CCOE
IP67
IP66
IP67
PORT CONNECTION
FUNCTION
OUTLET
INLET
UL *
NC 2 1
Contact Rotex for
• Any other Ambient, Fluid Temperature, Media and application
Specifications are subject to change without notice 345
5
28 NB PULSE JET SOLENOID VALVE
SPECIFICATION
PRE- SOLENOID ENCLOSURE
(LPM OF WATER @ 1 bar ΔP)
PORT BODY MATERIAL MANUAL POWER
SSURE SEALS
REFERENCE NUMBER
CONNECTION AND INTERNALS OVERRIDE WEATHER EXPLOSION VA
PILOT PRESSURE
bar PROOF PROOF
FLOW FACTOR kv
CONSTRUCTION
ORIFICE (mm)
VALVE TYPE
LARGE ENCLOSURE
Viton (S2)/ Viton+PTFE (S8)
TERMINAL BOX IP67
SQ. PLUG IN, IP67
(STD. PORT NPT)
(STD. PORT NPT)
EXPLOSION PROOF
ALUMINIUM + SS
SOLENOID SIZE
STAYPUT CUM
PLUG IN, IP67
MOMENTARY
FLYING LEAD
MOMENTARY
AC HOLDING
ALUMINIUM
AC INRUSH
SS 316/ CF8
MAXIMUM
MINIMUM
HYTREL
BRASS
BSP(F)
NPT(F)
EPDM
PTFE
IIC, IP67
SIZE
NBR
NIL
DC
INTEGRAL PILOT
3/4” 6G 6R 0.5 8.5 28 280 24108 ø B12 S0 S2 ø 22 T E 14 18 12 8 P3
3/4” 6G 6R 0.5 8.5 28 280 24108ET ø B12 S8 22 T E 14 18 12 8 P3
1” 8G 8R 0.5 8.5 28 310 24108 ø B12 S0 S2 ø 22 T E 14 18 12 8 P3
1” 8G 8R 0.5 8.5 28 310 24108ET ø B12 S8 22 T E 14 18 12 8 P3
Cable Entry T E = Do not specify when opted for. Refer Page 22 for Value of
Ex d Ex emb
M20 x 1.5 19 39 87MS 58MS 58LTMS
M25 x 1.5 87 58 58LT
1/2” NPT 16 37 87NS 58NS 58LTNS
ORDERING CODE, EXAMPLE VALVE + SOLENOID
TYPE ORIFICE PORT CONNECTION BODY AND INTERNALS SEAL +
VOLTAGE CURRENT SOLENOID ENCLOSURE APPROVAL INSULATION
e.g. 24108-28-8G+110V 50Hz-16, 24108ET-28-8G-S8+110V 50Hz-16
DIMENSIONS All Dimensions are in mm
CONSTRUCTION REFERENCE P3
85
11
M20 x 1.5(F)
1/2” NPT(F)
A
2 2
IN
C
C
B
C 1
C 1
D
TERMINAL BOX/ D
Ex d TYPE 16, 19, 37, 39, 58, 58LT
E
Ex ia SOLENOID WITH BOOSTER CIRCUIT
E
VALVE TYPE PIPE A B C D E VALVE TYPE PIPE A B C D E
CONN. CONN.
24108-28 3/4” 82 99 135 51 24 24108ET-28 3/4” 82 99 135 51 24
24108-28 1” 82 99 135 51 24 24108ET-28 1” 82 99 135 51 24
346
Specifications are subject to change without notice