Ecologone ReleaseNotes
Ecologone ReleaseNotes
ecologOne
1.1 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 Instructions - Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Purpose
This document is intended for specialists. These specialists are people who are qualified by their appropriate training
and their experience to see risks and to avoid possible hazards that may be caused during operation or maintenance of
the device.
The document contains additional information about the correct handling of the device and provides information about
known issues and addition release information. Read this document before use to familiarize yourself with the additional
information and known issues. Keep this document during the entire duration of use of the device.
WARNING!
Warning of serious personal injury. Death or serious irreversible injuries may result.
CAUTION!
Warning of personal injury. Slight reversible injuries may result. Damage on the machine may result when
instructions are not followed by the system integrator.
NOTICE!
Warning of damage to property.
Safety related Important warning Safety related Known issue which can cause serious
personal injury or damage property. Death or serious
irreversible injuries or damage on the machine may
result when instructions are not followed by the system
integrator.
Safety related Important note, non-compliance Safety related Known issue which can cause
may result in malfunction or interference. availability problems of the machine . Damage on the
machine may result when instructions are not followed
by the system integrator.
Safety related Information, supplementary note. Safety related Additional information for the integration
such as restrictions, implementation hints and
implementation examples.
Important note, non-compliance may result in Known issue which can cause availability problems of
malfunction or interference. the machine . Damage on the machine may result
when instructions are not followed by the system
integrator.
Software Feature Description of the new feature that was added in the
software version.
► Instruction Instruction
→ Cross-reference Cross-reference
WARNING! 2217
When installing ecologOne, the application is provided as a trusted application by ifm electronic gmbh, but
when uninstalling the application from the computer the process is declared as untrusted.
2217
Uninstalling process of ecologOne is not licensed
When installing ecologOne, the application is provided as a trusted application by ifm electronic gmbh, but
when uninstalling the application from the computer the process is declared as untrusted.
2014
User configurations do not remain after updating ecologOne
At the present stage of a fresh ecologOne installation, all configurations will revert to their
default settings. Any modifications executed via the system-tray will be reset to default,
necessitating manual reconfiguration.
2602
Communication timeout bigger than 21 second not effective
When setting the communication timeout to a value bigger than 21 seconds the timeout will appear after 21
seconds.
Every timeout below is effective.
After updating ecomatController / ecomatBasic, the device needs to be disconnected and 2190
connected again
1845
Connection ends in timeout when updating communication settings
If the communication settings of the connected device are changed over the 'Software' tab, the update never
shows that it has completed.
Instead the UI displays a timeout.
Error handling:
Workflow:
Version V1.2.4
New Features and Changes
2732
Connection timeout setting
The ecologOneServiceManager provides the possibility to set a connection timeout between 3s and 60s.
This is the timeout the application is waiting for a devices response.
2733
Displaying picture of connected device
If there is an internet connection, a picture of the device is displayed within the Identification tab.
2734
Opening ecologOneServiceManager
The ecologOneServiceManager can be opened by left or right clicking the ifm icon in the tray bar.
Fixed Issues
1936
ecologOne on Windows 11 not startable
2191
Application shows device tabs after update
After updating a device and refreshing the page it can happen, that the device tabs will be shown in the
connected devices page.
2216
Parallel use of Peak can adapter with ecologOne and CODESYS gateway not possible
When trying to use a peak can adapter within ecologOne and any other application (for example CODESYS),
only one application is possible to use the adapter.
That means the user has to stop either ecologOne or the other application that the Peak can adapter works.
2132
Setup of ecologOne needs .NET 6.0
Before installing the ecologOne-setup.exe, there is the need to install the .NET 6.0 Framework on the PC.
Please refer to the attached document 'ecologOne_SetupNotes_V1.1.2'.
Version V1.1.2
New Features and Changes
2228
Supported USB-to-CAN adapter
CANFox
IXXAT
Peak
2227
Supported devices
ecomatController
ecomatBasic
BasicSystem including:
BasicController
BasicDisplay
ioControl
SmartController
2229
Added ecologOneServiceManager
The ecologOneServiceManager can be reached through the System tray menu and supports the following
functionalities:
Start/Stop ecologOne
Changing the application port
Fixed Issues
2032
Overlapping in list of can adapter
When more than one can adapter was recognized, they are displayed overlapped in the selection.
1827
Updating ecomatController in bootloader mode fails
When updating a ecomatController that is in bootloader mode, the update is not possible.