SINGLE AISLE TECHNICAL TRAINING MANUAL

TOILET SYSTEM CONTROLS AND INDICATING (1)


FAP
The FAP is located in the forward section of the cabin.
WASTE QUANTITY
The FAP displays the waste quantity stored in the waste holding tank
when the VSC is not receiving any flush signals.
LAV INOP
The "LAVatory INOPerative" light comes on when the related lavatory
flush control unit has failed.
SYSTEM INOP
The "SYSTEM INOP" light comes on when the waste holding tank
is full or in case of vacuum generator failure.

NOTE: On ground, when the toilet service panel is open the


"SYSTEM INOP" light comes on.

MAINTENANCE COURSE - T1 & T2 TOILET SYSTEM CONTROLS AND INDICATING (1)


38 - WATER & WASTE Page 58