PROGRESSING CAVITY PUMP NO.
72X006 - 01
PERFORMANCE CURVES PAGE 1 of 2
MODEL 72X006 DATE MARCH 2006
0.6
1200 RPM
1 2 0 0 RP
0.5 M
FLOW ( GPM )
1000 RPM
1 0 0 0 RP
M
0.4
800 RPM
8 0 0 RP M
0.3
600 RPM
6 0 0 RP M
0.2
400 RPM
4 0 0 RP M
0.1
200 RPM
2 0 0 RP M
0.0
0 30 60 90 120
PRESSURE ( PSI )
70 DUROMETER 50 DUROMETER
16.5
TORQUE ( LBF.IN )
16.0
15.5
15.0
14.5
14.0
13.5
0 30 60 90 120
PRESSURE ( PSI )
CURVES ARE BASED ON 70º F WATER TORQUE(LBF.IN) x SPEED(RPM)
POWER(HP) =
STARTING TORQUE = 18 LBF.IN 63025
Roper Pump Company • 3475 Old Maysville Road • Commerce, GA 30529
PROGRESSING CAVITY PUMP NO. 72X006 - 01
PERFORMANCE CURVES PAGE 2 of 2
MODEL 72X006 DATE MARCH 2006
NPSHR
SPEED (RPM) 200 400 600 800 1000 1200
NPSHR (FT) 0.3 0.6 0.9 1.2 1.5 1.8
TABLE A ABRASIVE CONDITIONS
ABRASION NONE LIGHT MEDIUM HEAVY
MAX. PRESSURE (PSI) 60 50 30 15
MAX. SPEED (RPM) 1200 900 600 300
TABLE B APPARENT VISCOSITY - TORQUE ADDITIVE AND MAXIMUM SPEED
VISCOSITY (CP) 100 1000 2500 5000 10,000 50,000 100,000 150,000 200,000
TORQUE (LBF.IN) 0.5 1.4 2 3 4 8.4 11.6 14 16
SPEED (RPM) 1200 1200 1200 600 320 80 40 30 25
TABLE C WATER BASE SLURRY TORQUE ADDITIVE (LBF.IN)
SOLID PARTICLE SIZE (IN)
CONTENT (%) 0.01 to 0.04 0.04 to 0.08
10 9.4 17.5
30 28 52.5
50 47 87.5
TABLE D STARTING TORQUE MULTIPLIERS
TEMPERATURE (º F)
ROTOR 70 100 125 150 175 200 230 250 275 300 350
STANDARD 1.0 1.1 1.3 1.6 1.8
SINGLE U/S 1.1 1.3 1.6 1.8 2.0
DOUBLE U/S 1.0 1.1 1.3 1.6 1.8
GENERAL INSTRUCTIONS
1) DETERMINE WHICH TABLE (B OR C) APPLIES TO YOUR FLUID AND FIND THE APPROPRIATE
CHARACTERISTICS. DETERMINE THE TORQUE ADDITIVE AND ADD IT TO THE TORQUE FOR
WATER ON THE CURVE. IF YOUR FLUID IS A COMBINATION OF BOTH SLURRY AND VISCOUS
MATERIAL, DETERMINE THE APPROPRIATE TORQUE ADDITIVE FROM BOTH TABLES AND
ONLY USE THE GREATER OF THE TWO TO ADD TO THE TORQUE FOUND FOR WATER.
2) FIND THE FACTOR FROM TABLE TO THE TEMPERATURE OF YOUR FLUID AND STYLE OF
ROTOR. MULTIPLY THE STARTING TORQUE SHOWN BY THIS FACTOR TO OBTAIN THE
CORRECTED STARTING TORQUE.
COMPARE THE RESULTS FROM STEPS 1 AND 2. THE REQUIRED TORQUE WILL BE THE
GREATER OF THE TWO.
Roper Pump Company • 3475 Old Maysville Road • Commerce, GA 30529
PROGRESSING CAVITY PUMP NO. 73X006 - 01
PERFORMANCE CURVES PAGE 1 of 2
MODEL 73X006 DATE MARCH 2006
0.6
1200 RPM
1200 RP
0.5 M
FLOW ( GPM )
1000 RPM
1000 RP
M
0.4
800 RPM
800 RPM
0.3
600 RPM
600 RP
M
0.2
400 RPM
400 RPM
0.1 200 RPM
200 RP
M
0.0
0 50 100 150 200
PRESSURE ( PSI )
70 DUROMETER 50 DUROMETER
24.8
TORQUE ( LBF.IN )
24.0
23.2
22.4
21.6
20.8
20.0
0 50 100 150 200
PRESSURE ( PSI )
CURVES ARE BASED ON 70º F WATER TORQUE(LBF.IN) x SPEED(RPM)
POWER(HP) =
STARTING TORQUE = 18 LBF.IN 63025
Roper Pump Company • 3475 Old Maysville Road • Commerce, GA 30529
PROGRESSING CAVITY PUMP NO. 73X006 - 01
PERFORMANCE CURVES PAGE 2 of 2
MODEL 73X006 DATE MARCH 2006
NPSHR
SPEED (RPM) 200 400 600 800 1000 1200
NPSHR (FT) 0.3 0.6 0.9 1.2 1.5 1.8
TABLE A ABRASIVE CONDITIONS
ABRASION NONE LIGHT MEDIUM HEAVY
MAX. PRESSURE (PSI) 60 50 30 15
MAX. SPEED (RPM) 1200 900 600 300
TABLE B APPARENT VISCOSITY - TORQUE ADDITIVE AND MAXIMUM SPEED
VISCOSITY (CP) 100 1000 2500 5000 10,000 50,000 100,000 150,000 200,000
TORQUE (LBF.IN) 0.7 2 3.2 4.4 6 12.6 17.4 21 24
SPEED (RPM) 1200 1200 1200 600 320 80 40 30 25
TABLE C WATER BASE SLURRY TORQUE ADDITIVE (LBF.IN)
SOLID PARTICLE SIZE (IN)
CONTENT (%) 0.01 to 0.04 0.04 to 0.08
10 11 20.5
30 33 62
50 55 103
TABLE D STARTING TORQUE MULTIPLIERS
TEMPERATURE (º F)
ROTOR 70 100 125 150 175 200 230 250 275 300 350
STANDARD 1.0 1.1 1.3 1.6 1.8
SINGLE U/S 1.1 1.3 1.6 1.8 2.0
DOUBLE U/S 1.0 1.1 1.3 1.6 1.8
GENERAL INSTRUCTIONS
1) DETERMINE WHICH TABLE (B OR C) APPLIES TO YOUR FLUID AND FIND THE APPROPRIATE
CHARACTERISTICS. DETERMINE THE TORQUE ADDITIVE AND ADD IT TO THE TORQUE FOR
WATER ON THE CURVE. IF YOUR FLUID IS A COMBINATION OF BOTH SLURRY AND VISCOUS
MATERIAL, DETERMINE THE APPROPRIATE TORQUE ADDITIVE FROM BOTH TABLES AND
ONLY USE THE GREATER OF THE TWO TO ADD TO THE TORQUE FOUND FOR WATER.
2) FIND THE FACTOR FROM TABLE TO THE TEMPERATURE OF YOUR FLUID AND STYLE OF
ROTOR. MULTIPLY THE STARTING TORQUE SHOWN BY THIS FACTOR TO OBTAIN THE
CORRECTED STARTING TORQUE.
COMPARE THE RESULTS FROM STEPS 1 AND 2. THE REQUIRED TORQUE WILL BE THE
GREATER OF THE TWO.
Roper Pump Company • 3475 Old Maysville Road • Commerce, GA 30529
PROGRESSING CAVITY PUMP NO. 76X006 - 01
PERFORMANCE CURVES PAGE 1 of 2
MODEL 76X006 DATE MARCH 2006
0.6
1200 RPM
1200 RP
0.5 M
FLOW ( GPM )
1000 RPM
1000 RP
M
0.4
800 RPM
800 RPM
0.3
600 RPM
600 RP
M
0.2
400 RPM
400 RPM
0.1 200 RPM
200 RP
M
0.0
0 100 200 300 400
PRESSURE ( PSI )
70 DUROMETER 50 DUROMETER
49.6
TORQUE ( LBF.IN )
48.0
46.4
44.8
43.2
41.6
40.0
0 100 200 300 400
PRESSURE ( PSI )
CURVES ARE BASED ON 70º F WATER TORQUE(LBF.IN) x SPEED(RPM)
POWER(HP) =
STARTING TORQUE = 24 LBF.IN 63025
Roper Pump Company • 3475 Old Maysville Road • Commerce, GA 30529
PROGRESSING CAVITY PUMP NO. 76X006 - 01
PERFORMANCE CURVES PAGE 2 of 2
MODEL 76X006 DATE MARCH 2006
NPSHR
SPEED (RPM) 200 400 600 800 1000 1200
NPSHR (FT) 0.3 0.6 0.9 1.2 1.5 1.8
TABLE A ABRASIVE CONDITIONS
ABRASION NONE LIGHT MEDIUM HEAVY
MAX. PRESSURE (PSI) 60 50 30 15
MAX. SPEED (RPM) 1200 900 600 300
TABLE B APPARENT VISCOSITY - TORQUE ADDITIVE AND MAXIMUM SPEED
VISCOSITY (CP) 100 1000 2500 5000 10,000 50,000 100,000 150,000 200,000
TORQUE (LBF.IN) 1.4 4.2 6.3 9 12 26 35 42 48
SPEED (RPM) 1200 1200 1200 600 320 80 40 30 25
TABLE C WATER BASE SLURRY TORQUE ADDITIVE (LBF.IN)
SOLID PARTICLE SIZE (IN)
CONTENT (%) 0.01 to 0.04 0.04 to 0.08
10 15 27
30 44 82
50 73 136
TABLE D STARTING TORQUE MULTIPLIERS
TEMPERATURE (º F)
ROTOR 70 100 125 150 175 200 230 250 275 300 350
STANDARD 1.0 1.1 1.3 1.6 1.8
SINGLE U/S 1.1 1.3 1.6 1.8 2.0
DOUBLE U/S 1.0 1.1 1.3 1.6 1.8
GENERAL INSTRUCTIONS
1) DETERMINE WHICH TABLE (B OR C) APPLIES TO YOUR FLUID AND FIND THE APPROPRIATE
CHARACTERISTICS. DETERMINE THE TORQUE ADDITIVE AND ADD IT TO THE TORQUE FOR
WATER ON THE CURVE. IF YOUR FLUID IS A COMBINATION OF BOTH SLURRY AND VISCOUS
MATERIAL, DETERMINE THE APPROPRIATE TORQUE ADDITIVE FROM BOTH TABLES AND
ONLY USE THE GREATER OF THE TWO TO ADD TO THE TORQUE FOUND FOR WATER.
2) FIND THE FACTOR FROM TABLE TO THE TEMPERATURE OF YOUR FLUID AND STYLE OF
ROTOR. MULTIPLY THE STARTING TORQUE SHOWN BY THIS FACTOR TO OBTAIN THE
CORRECTED STARTING TORQUE.
COMPARE THE RESULTS FROM STEPS 1 AND 2. THE REQUIRED TORQUE WILL BE THE
GREATER OF THE TWO.
Roper Pump Company • 3475 Old Maysville Road • Commerce, GA 30529