Longer Cycle Life:Offer up to 10 times longer cycle life and five

times longer float/calendar life than lead acid battery, helping it


minimize re placement cost and reduce total cost of ownership.

Lighter Weight:About 40% of the weight of a comparable lead


acid battery. A'drop in' replacement for lead acid batteries.

Higher Power:Delivers twice power of lead acid battery, even high


discharge rate, while maintaining high energy capacity.

Wider Temperature Range:-20~60℃

Superior Safety:Lithium Iron Phosphate chemistry eliminates the


risk of explosion or combustion due to high impact, overcharging or
short circuit situation.

· Solar/Wind energy Storage


· Golf cart
· Back-up Power for UPS/EPS
· Tools

www.songligroup.com
VRLA Battery MM 100-12 12V100AH

Medium-size Battery
MHB MM Series—Medium-size Battery
l High performance, completely maintenance-free, low self-discharge
l 100% precise quality testing, stable quality and high reliable performance
l Unique grid alloy formula and updated manufacturing technique
l Floating & standby use:up to 8 years
l Cycle use 1: Up to 260 cycles at 100% DOD
l Cycle use 2: Up to 500 cycles at 50% DOD

Application:
l Telecommunications l Alarm and security system
l Uninterruptable Power Supply (UPS) l Communication power supply
l Electric Power System (EPS) l DC power supply
l Emergency backup power supply l Auto control system

Construction:
l Component ......Raw material l Sealant ........Epoxy
l Positive ........Lead dioxide l Safety valve .... Rubber
l Negative ........Lead l Terminal ........Copper/Pb
l Container ........ABS l Separator ........Fiber glass
l Cover ........ABS l Electrolyte ....... Sulfuric acid

B5 Terminal T13 Terminal

Speification:
Battery Model MM 100-12 12V100AH
Designed Floating Life Up to 8 Years
20HR(5.240A,10.8V) 10HR(10.00A,10.8V) 5HR(17.530A,10.5V) 1HR(54.200A,10.5V)
Capacity (25℃)
104.80 AH 100.00 AH 87.65 AH 54.20 AH
Length Width Height Total Height
Dimensions
330 mm 173 mm 217 mm 220 mm
Approx. Weight 29.00 KG±3%
Internal Resistance Full charged at 25℃:≤7.00 mΩ
Self Discharge 2% of capacity declined per month at (25℃)
Capacity Affected 40℃ 25℃ 0℃ -15℃
by Temp.(20HR) 102% 100% 85% 65%
Cycle use Float use
Charge Voltage(25℃)
14.4-14.6V(-30mV/℃), max. Current:25.00A 13.5-13.8V (-20mV/℃)

FUJIAN MINHUA POWER SOURCE CO., LTD.


www.mhb-battery.com
VRLA Battery MM 100-12 12V100AH

Terminal Voltage (V) and Discharge Time Capacity Retention Characteristic

Battery Vlotage and Charge Time for Standby Use Battery Vlotage and Charge Time for Cycle Use

Tickle(or Float) Service Life Cycle Service Life

Battery Vlotage and Charge Time for Cycle Use

Constant Current Discharge(CC,Unit:A) at 25℃(77℉)


F.V/Time 5Min 10Min 15Min 30Min 1Hr 2Hr 3Hr 4Hr 5Hr 6Hr 10Hr 20Hr
1.80V/Cell 309.7 210.7 144.2 87.72 53.75 33.54 26.08 20.51 17.39 11.62 10.00 5.24
1.75V/Cell 312.3 212.5 145.5 88.46 54.20 33.83 26.30 20.68 17.53 11.71 10.15 5.31
1.70V/Cell 320.1 217.8 149.1 90.68 55.56 34.67 26.96 21.20 17.97 12.01 10.30 5.39
1.67V/Cell 327.9 223.1 152.7 92.89 56.91 35.52 27.61 21.72 18.41 12.30 10.45 5.47
1.60V/Cell 342.5 233.0 159.5 97.02 59.45 37.10 28.84 22.69 19.23 12.85 10.60 5.55
Constant Power Discharge (CP,Unit:W) at 25℃(77℉)
F.V/Time 5Min 10Min 15Min 30Min 1Hr 2Hr 3Hr 4Hr 5Hr 6Hr 10Hr 20Hr
1.80V/Cell 603.9 410.8 281.3 171.1 104.8 65.41 50.85 40.00 33.90 22.65 19.50 10.21
1.75V/Cell 609.0 414.3 283.7 172.5 105.7 65.96 51.28 40.34 34.19 22.84 19.79 10.36
1.70V/Cell 624.2 424.7 290.8 176.8 108.3 67.61 52.57 41.34 35.04 23.41 20.09 10.52
1.67V/Cell 639.4 435.0 297.8 181.1 111.0 69.26 53.85 42.35 35.90 23.98 20.38 10.67
1.60V/Cell 667.9 454.4 311.1 189.2 115.9 72.35 56.25 44.24 37.50 25.05 20.67 10.82