0% found this document useful (0 votes)
172 views4 pages

General Characteristics: Power Definition

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
172 views4 pages

General Characteristics: Power Definition

Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

J44K

Engine type 3029TF120


Alternator type ECO32-3S

GENERAL CHARACTERISTICS
Frequency (Hz) 50
Reference voltage (V) T51A2
Max power ESP (kVA) 44
Max power ESP (kWe) 35.2
Max power PRP (kVA) 40
Max power PRP (kWe) 32
Intensity (A) 64
Standard Control Panel NEXYS
Optional control panel TELYS

DIMENSIONS AND NOISE LEVELS


DIMENSIONS COMPACT VERSION
Length (mm) 1700
Width (mm) 896
Height (mm) 1221
Dry weight (kg) 820
Tank capacity (L) 100

DIMENSIONS SOUNDPROOFED VERSION


DESCRIPTIVE Canopy M127
Mechanic governor Length (mm). 2080
Mechanically welded chassis with antivibration
Width (mm). 960
suspension
Main line circuit breaker Height (mm). 1415
Radiator for wiring temperature of 48/50°C max with Dry weight (kg). 1040
mechanical fan Tank capacity (L). 100
Protective grille for fan and rotating parts
Acoustic pressure level @1m in dB(A) 73.4
9 dB(A) silencer supplied separately
Sound power level guaranteed (Lwa) 90
Charger DC starting battery with electrolyte
12 V charge alternator and starter
Delivered with oil and coolant -30°C POWERS
Manual for use and installation ESP PRP
Voltage Standby Amps
kWe kVA kWe kVA

415/240 35 44 32 40 61
400/230 35 44 32 40 64
POWER DEFINITION 380/220 35 44 32 40 67
PRP : Prime Power is available for an unlimited number 240 TRI 35 44 32 40 106
of annual operating hours in variable load applications, in
accordance with ISO 8528-1.
230 TRI 35 44 32 40 110
220 TRI 35 44 32 40 115
ESP : The standby power rating is applicable for 220/127 28 35 25 32 92
supplying emergency power in variable load applications in 200/115 35 44 32 40 127
accordance with ISO 8528-1.
Overload is not allowed.

STANDARD TERMS OF USE


27°C/40°C Air Intlet Temp.
1000 m A.S.L.
30% relative humidity.

This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to
improve the quality of its products.
J44K
TECHNICAL SPECIFICATIONS

GENERAL ENGINE DATAS EXHAUST


JOHN DEERE Exhaust gas temperature (°C) 510
3029TF120 ,
Engine model Exhaust gas flow (L/s) 105.6
4-temps, TURBO ,
N/A 3 X Max. exhaust back pressure (mm EC) 625
Cylinder arrangement L
Displacement (C.I.) 2.91
FUEL
Bore (mm) x Stroke (mm) 106 x 110
Consumption @ 110% load (L/h) 10.8
Compression ratio 17.8
Consumption @ 100% load (L/h) 9.8
Speed (RPM) 1500
Consumption @ 75% load (L/h) 7.5
Pistons speed (m/s) 5.5
Maximum stand-by power at rated Consumption @ 50% load (L/h) 5.3
40
RPM (kW) Maximum fuel pump flow (L/h) 111
Frequency regulation (%) 2.5
BMEP (bar) 10
OIL
Governor type MECA
Oil capacity (L) 6
Min. oil pressure (bar) 1
COOLING SYSTEM
Max. oil pressure (bar) 5
Radiator & Engine capacity (L) 16.1
Oil consumption 100% load (L/h) 0.01
Max water temperature (°C) 105
Carter oil capacity (L) 5.3
Outlet water temperature (°C) 93
Fan power (kW) 1.5
HEAT BALANCE
Fan air flow w/o restriction (m3/s) 1.86
Available restriction on air flow (mm Heat rejection to exhaust (kW) 38
20
EC) Radiated heat to ambiant (kW) 5
Type of coolant GENCOOL Haet rejection to coolant (kW) 28
Thermostat (°C) 82-94

AIR INTAKE
EMISSIONS Max. intake restriction (mm EC) 300
Emission PM (g/kW.h) N/A Intake air flow (L/s) 37.8
Emission CO (g/kW.h) N/A
Emission HCNOx (g/kWh) N/A
Emission HC (g/kW.h) N/A

This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to
improve the quality of its products.
J44K
ALTERNATOR SPECIFICATIONS

GENERAL DATAS OTHER DATAS


Alternator brand MECC ALTE Continuous Nominal Rating 40°C (kVA) 40
Alternator type ECO32-3S Standby Rating 27°C (kVA) 44
Number of phase 3 Efficiencies 4/4 load (%) 87.4
Power factor (Cos Phi) 0.8 Air flow (m3/s) 0.2
Altitude (m) 1000 Short circuit ratio (Kcc) 0.8
Overspeed (rpm) N/A Direct axis synchro reactance unsaturated (Xd) (%) 190
Number of pole 4 Quadra axis synchro reactance unsaturated (Xq) (%) 98
Excitation system NO Open circuit time constant (T'do) (ms) 1.4
Insulation class / T° class, continuous Direct axis transcient reactance saturated (X'd) (%) 14.3
H/H
40°C
Short circuit transcient time constant (T'd) (ms) 61
Regulation AVR
Direct axis subtranscient reactance saturated (X''d)
Harmonic factor, no load TGH/THC N/A 10
(%)
Wave form : NEMA=TIF-(TGH/THC) N/A Subtranscient time constant (T"d) (ms) 15
Wave form : CEI=FHT-(TGH/THC) N/A Quadra axis subtranscient reactance saturated (X"q)
30.6
(%)
Number of bearing 1
Zero sequence reactance unsaturated (Xo) (%) 2.7
Coupling DIRECT
Negative sequence reactance saturated (X2) (%) 21.5
Voltage regulation at established rating
N/A Armature time constant (Ta) (ms) 31
(%)
Recovery time (Delta U = 20% N/A No load excitation current (io) (A) N/A
transcient) (ms)
Full load excitation current (ic) (A) N/A
Full load excitation voltage (uc) (V) N/A
Recovery time (Delta U = 20% transcient) (ms) N/A
Engine start (Delta U = 20% perm. or 50% trans.)
N/A
(kVA)
Transcient dip (4/4 load) - PF : 0,8 AR (%) N/A
No load losses (W) N/A
Heat rejection (W) N/A

DIMENSIONS AND NOISE LEVELS


CONTAINMENT CONTAINMENT 48H
Canopy M127 DW M127
Canopy
Length (mm). 2160 DW48
Width (mm). 966 Length (mm). 2160
Height (mm). 1582 Width (mm). 966
Dry weight (kg). 1227 Height (mm). 1631
Tank capacity (L). 230 Dry weight (kg). 1215
Acoustic pressure level @1m in dB(A) 73.4 Tank capacity (L). 420
Sound power level guaranteed (Lwa) 90 Acoustic pressure level @1m in dB(A) 73.4
Sound power level guaranteed (Lwa) 90

This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to
improve the quality of its products.
J44K
CONTROL PANEL

NEXYS, comprehensive and simple TELYS, ergonomic and user-friendly

The NEXYS is a versatile control unit allowing The highly versatile TELYS control unit is complex yet
operation in manual or automatic mode. Equipped accessible, thanks to the particular attention paid to
with an LCD screen, the user-friendly NEXYS offers optimising its ergonomics and ease of use. With its
high-quality basic functions to guarantee simple, large display screen, buttons and scroll wheel, it
reliable operation of your generating set. places the accent on simplicity and communication.

Offers the following functions: The TELYS offers the following functions:

Standard electrical measurements: voltmeter, Electrical measurements: voltmeter, frequency


frequency meter, ammeter. meter, ammeter.

Engine parameters: working hours counter, Engine parameters: working hours counter, oil
engine speed, battery voltage, fuel level. pressure, coolant temperature, fuel level, engine
speed, battery voltage.
Alarms and faults: oil pressure, coolant
temperature, failure to start, overspeed (> 60 kVA), Alarms and faults: oil pressure, coolant
charging alternator fault, low fuel level, emergency temperature, failure to start, overspeed, alternator
stop. min./max., battery voltage min./max., emergency stop,
fuel level.
For more information, please refer to the sales
documentation. Ergonomics: wheel for navigating around the
various menus.

Communication: remote control and operation


software, USB connections, PC connection.

For more information on the product and its options,


please refer to the sales documentation.

This document is not contractual - The SDMO company reserves the right to modify any of the characteristics stated in this CD Rom without notice, in a constant effort to
improve the quality of its products.

You might also like