M331 Industrial Cellular Router LED Indicators of Ethernet Port

Quick Installation Guide Version: 1.00 There are two LED indicators for each of three LAN ports and one WAN
port.

Install the SIM Card


STEP 1: Before inserting or removing the SIM card, ensure that the
power has been turned off, or the power connector has been
removed from the M331 Cellular Router.
STEP 2: Using a screwdriver to remove the metal protective cover first,
insert the SIM card into the card slots. The cut-off edge of the
SIM card on upper SIM slot 1 (lower SIM slot 2) is to the left
(right).
STEP 3: Push the SIM card and lightly press it to lock into the slot. LED Blinking On Off
STEP 4: Remove the SIM card, lightly press it and it will pop out of the 1000M N/A 1000Mbps 10/100Mbps
slot.
LINK Data Transmitting LINK UP LINK DOWN

RS-232 and RS-485 pinouts

LED Indicators
The following table explains the LED indicators on the front panel.
LED Off On Slow Fast Heartbeat

Power
SYS Power up N/A N/A N/A
down
NOTE:
Not  RS-232 and RS-485 share the common ground pin “G”.
SIM Connected Connecting Error Reading
working

Medium Low RS-232


Signal No signal High signal N/A
signal signal
Pin Signal Direction
TX Transmit Data Output
Reset Button
RX Receive Data Input
G Signal Ground -
Function Operation

Reset Press the button for 1 seconds.


RS-485
Reset to default setting Press the button for more than 5 seconds.
Pin Description
D+ Serial Port, Data+ (A) wire
Connecting I/O Ports D- Serial Port, Data- (B) wire
There are four terminals on the terminal block with two terminals used G Signal Ground
for digital input and two terminals used for digital output.

Pin Description
DI +
Digital Input
DI -
DO +
Digital Output
DO -
DI: Low (+0 to +3V) / High (+8 to +40V)
DO: Open Collect (maximum 30V/300mA)

P/N: 604040000077
-1-
Connecting the Power Supply Wall Mounting
Powering the M331 Cellular Router is by either a terminal block or a DC STEP 1: At the bottom side of the device, use two screws to install each
jack.
bracket.
One terminal block is on the front panel. NOTE:
The power input voltage range is 8 ~ 26 VDC.  Each screw type is flat head M3 x 6 mm.
STEP 2: Use the screws to attach the bracket of the device for wall
mounting.
NOTE:
One DC Jack is on the front panel.  These screws are not included in the package. The head of each screw is less
than 7 mm in diameter, the shaft is less than 3 mm in diameter, and the length
The power input voltage is 12 VDC.
is less than 10 mm in diameter.

Antenna Installation
Three SMA connectors placed on the left panel are for connecting to

external LTE and GPS antennas.

 MAIN: for LTE Transmit and Receive

 AUX: for optional LTE Receive for better downstream speed

 GPS: for GPS

Setup
(1) Access the Web Configurator
a. Type the default URL http://192.168.1.1 in your web browser.
DIN-rail Mounting b. In the login page, enter the default username root and the default

STEP 1: Use the screws to install the DIN-rail kit to attach at the rear side password 2wsx#EDC and then click the Login button.

of the device.
NOTE: (2) Change Password
 Three screw types are flat head M3 x 4 mm. Go to the Management -> Administration and enter the desired New
Password and then scroll down the page and click the Apply button.

NOTE

 Please scan below QR Code to download online resources.


Download link: https://www.proscend.com/en/product/M331.html

STEP 2: Hook the unit onto the DIN-rail.


STEP 3: Push the bottom of the unit towards the DIN-rail until it locks in
place.