Logging into Network Element – CIENA 6200

Method of Procedure

MOP Author: Sean Proctor

Final Document Verification Date: 01‐09‐2014

Ciena 6200
Page 1 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
DOCUMENT CHANGE HISTORY

Version Status Reason for Change / Reissue Engineer Date

R1 F Document Content S. Proctor 01‐09‐2014

I = Initial

T= Template

D= Draft

F = Final

Ciena 6200
Page 2 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
PROJECT OVERVIEW

This document describes the initial turn‐up and provisioning of the Ciena 6200.

REQUIRED EQUIPMENT

1. Laptop
2. Ciena 6200 Network Element
3. Straight thru Ethernet cable
4. Intuition

LIGHTRIVER CONTACT LIST

Name Title Phone Email


Associate Field
Sean Proctor 925‐878‐8152 [email protected]
Engineer

Ciena 6200
Page 3 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
METHOD OF PROCEDURE – NETWORK ELEMENT AUDIT

Step 1: Log into the System

Logging in locally using Web Browser

1. Verify that you have an Ethernet straight‐through cable to connect to your laptop and to the Craft terminal
on the Fan or Fan+OAM card.
2. Ensure that the 15G MRO XC or 60G MRO XC card is fully seated.
3. If logging in via Ethernet, verify that you have the proper network information (i.e. IP Address, Subnet Mask,
User name, and Password) of the Network Element that you are logging into
4. Change your PC’s IP Address to automatically obtain an IP address and select “OK”:

When connected to the Craft port, the DHCP setting can be used to obtain an IP address automatically from
the network element. When connected to the LAN port, a static IP address must be used that is on the same
subnet mask as the network element.
a. The default IP address of the 6200 is:
i. 192.168.1.254:20080
ATTENTION: If the session is logged out of the node and won’t let the user log back in, switch the laptop IP
setting to a static IP on the same subnet as the 6200.

5. Connect the Ethernet straight through cable to the Craft port on the Fan or Fan+OAM card on the 6200 and
to the Ethernet port on the PC.

Ciena 6200
Page 4 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
6. Launch a web browser and enter the URL:
a. http://192.168.1.254:20080
7. Enter the User Name and Password of the Network Element provided by the customer.
a. The default user name and password are:
i. User name: ADMIN
ii. Password: ADMIN

For a brand new node, the Node Configuration page will display prompting to Restore from a previously backed up
configuration or to Initialize Node Parameters.

Ciena 6200
Page 5 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
A brand new node must be configured. The options are: Initialize Node Parameters or Configure Network Element
from existing Backup.

To Initialize Node Parameters:

1. Click Initialize Node Parameters.


2. Enter the network element name in the name field.
3. Enter the functional router ID of the network in the router ID field of the NE information page. Network
element uses same entered ID for communication over ECC path.
4. In the Ethernet IP field the IP address must be entered. The Ethernet IP of each network element in the
network must be in different networks and unique.
a. CAUTION: Changing any settings will kick you off the system and prevent login for an extended
period. Therefore, don’t change any settings!
5. Select the SDH or SONET for the mode in which the network element needs to function.

6. Click Submit
7. Click Accept Valid Modifications.
Ciena 6200
Page 6 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
To restore from a previously backed up configuration:

1. Click on the Restore from a previously backed up configuration.

2. Enter the parameters for restoring configuration.


3. Click Submit.
4. Click Accept Valid Modifications.

Ciena 6200
Page 7 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
Step 2: Entering Network Element Information

Once the initial setup has been completed, log into the network element to see the Network Element Information
screen. From this screen, the TID, IP Address, Router IP, Contact Name, and Location can be changed.

1. The Site Manager Network Element view will be displayed after logging into the node.

2. Enter new Shelf TID, IP Address, and Router ID (Gateway Address).


3. Select Submit.
4. NE will reboot and kick you out for 10‐15 minutes.

Ciena 6200
Page 8 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
Step 3: Navigating the Network Element

1. To view the Node Slot View, select the Node Slot view in the left‐hand menu.

View Active Alarms


1. View Active Alarms by selecting the Faults menu on the left and selecting Active Alarms.

Step 4: Create Cross Connect


Ciena 6200
Page 9 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
1. Click Configuration in the Navigation menu.
2. Click Cross‐connect.

3. Click Add Cross‐connect.

Ciena 6200
Page 10 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
4. Select from the pull down list or enter the appropriate values against the fields.

Ciena 6200
Page 11 Version 1.0 Date: 1/9/14
Method of Procedure

LightRiver Technologies – Proprietary


Use pursuant to company instructions – All Rights Reserved
5. Click Submit.
A confirmation page is displayed.
6. Click Yes.
A success message is displayed.

Log out of 6200 Node


End