S150
S150
S150
1900
8250
420
Bar Dia (m 12
Spacing ( 125
c) Loading: 160 0
S2 UDL for DL+LL ,w =
M
d) Concrete Grade =M
9.45
e) Grade of steel= Fe
Ly=
From Table - 26 of IS: 456 - 2000,Moment Factors and subsequently Moments and reinforcements are obtained
Moments k=1-4.6*r/
Dir. Location Moment Factors r=M/bd^2
(T-M/M run) fck
pt Provided = 0.36 %
Referring to IS: 456 -2000;Cl.23.2.1and FIG. 4
Where,
Effective Span (Lx) = centre to centre dist. of support = 5.01
Mod Factor= depending on pt provided = 1.60
Therefore,
dreqd. = 120.43 mm.<Provided
OK
830729938.xls,S2 12/23/2024
M.N.Consultants(P) Ltd. HSG 010 (Block-A) 1st Floor
1.89 89 80 90
50 6 0.533
= 0.933 T/M2
25
415
160
Slab = D-15-4= 141
Ast
pt=50*p*fc Reqd. Ast
p=1-sqrtk Ast(cm^2/m run) Reinf. Provided
k/Fe (cm2/ Prov.
Mrun)
N/mm2
830729938.xls,S2 12/23/2024
M.N.Consultants(P) Ltd. HSG 010 (Block-A) 1st Floor
c) Loading:
S5 UDL for DL+LL ,w = 1.303 T/M2
M
d) Concrete Grade =M 20
3.81
e) Grade of steel= Fe 415
Ly=
From Table - 26 of IS: 456 - 2000,Moment Factors and subsequently Moments and reinforcements are
obtained as below:
Ast
Moments Reqd. Ast
Dir. Location Moment Factors Reinf. Provided
(T-M/M run) (cm2/ Prov.
Mrun)
Suppt. axs = 0.060 axs.w.lx2 = 0.86 5.04 8 Tor @ 100 c/c 5.03
X-Dir
Span axm = 0.045 axm.w.lx2 = 0.65 3.78 8 Tor @ 125 c/c 4.02
Suppt. ays = 0.047 ays.w.lx2 = 0.68 3.95 8 Tor @ 125 c/c 4.02
Y-Dir
Span aym = 0.035 aym.w.lx2 = 0.50 2.94 8 Tor @ 150 c/c 3.35
pt Provided = 0.50 %
Referring to IS: 456 -2000;Cl.23.2.1and FIG. 4
Where,
Effective Span (Lx) = centre to centre dist. of support = 3.33 M
Mod Factor= depending on pt provided = 1.60
Therefore,
dreqd. = 86.59 mm.<Provided
O.K.
830729938.xls,S2 A 12/23/2024
M.N.Consultants(P) Ltd. HSG 010 (Block-A) 1st Floor
M
d) Concrete Grade =M 20
1.48
e) Grade of steel= Fe 415
Ly=
From Table - 26 of IS: 456 - 2000,Moment Factors and subsequently Moments and reinforcements are
obtained as below:
Ast
Moments Reqd. Ast
Dir. Location Moment Factors Reinf. Provided
(T-M/M run) (cm2/ Prov.
Mrun)
Suppt. axs = 0.060 axs.w.lx2 = 0.13 0.78 8 Tor @ 100 c/c 5.03
X-Dir
Span axm = 0.045 axm.w.lx2 = 0.10 0.59 8 Tor @ 125 c/c 4.02
Suppt. ays = 0.047 ays.w.lx2 = 0.11 0.61 8 Tor @ 150 c/c 3.35
Y-Dir
Span aym = 0.035 aym.w.lx2 = 0.08 0.46 8 Tor @ 200 c/c 2.51
pt Provided = 0.50 %
Referring to IS: 456 -2000;Cl.23.2.1and FIG. 4
Where,
Effective Span (Lx) = centre to centre dist. of support = 1.31 M
Mod Factor= depending on pt provided = 1.80
Therefore,
dreqd. = 30.32 mm.<Provided
O.K.
830729938.xls,S3A 12/23/2024
M.N.Consultants(P) Ltd. HSG 010 (Block-A) 1st Floor
c) Loading:
S4 UDL for DL+LL ,w = 1.230 T/M2
M
d) Concrete Grade =M 20
4.62
e) Grade of steel= Fe 415
Ly=
From Table - 26 of IS: 456 - 2000,Moment Factors and subsequently Moments and reinforcements are
obtained as below:
Ast
Moments Reqd. Ast
Dir. Location Moment Factors Reinf. Provided
(T-M/M run) (cm2/ Prov.
Mrun)
Suppt. axs = 0.053 axs.w.lx2 = 0.69 3.39 8 Tor @ 125 c/c 4.02
X-Dir
Span axm = 0.041 axm.w.lx2 = 0.53 2.62 8 Tor @ 175 c/c 2.87
Suppt. ays = 0.032 ays.w.lx2 = 0.42 2.05 8 Tor @ 175 c/c 2.87
Y-Dir
Span aym = 0.024 aym.w.lx2 = 0.31 1.53 8 Tor @ 200 c/c 2.51
pt Provided = 0.30 %
Referring to IS: 456 -2000;Cl.23.2.1and FIG. 4
Where,
Effective Span (Lx) = centre to centre dist. of support = 3.25 M
Mod Factor= depending on pt provided = 1.60
Therefore,
dreqd. = 84.64 mm.<Provided
O.K.
830729938.xls,S4 12/23/2024
M.N.Consultants(P) Ltd. HSG 010 (Block-A) 1st Floor
c) Loading:
S5 UDL for DL+LL ,w = 1.300 T/M2
M
d) Concrete Grade =M 20
7.90
e) Grade of steel= Fe 415
Ly=
From Table - 26 of IS: 456 - 2000,Moment Factors and subsequently Moments and reinforcements are
obtained as below:
Ast
Moments Reqd. Ast
Dir. Location Moment Factors Reinf. Provided
(T-M/M run) (cm2/ Prov.
Mrun)
Suppt. axs = 0.060 axs.w.lx2 = 1.69 6.10 10 Tor @ 200 c/c 0.39
X-Dir
Span axm = 0.045 axm.w.lx2 = 1.27 4.58 8 Tor @ 200 c/c 2.51
Suppt. ays = 0.032 ays.w.lx2 = 0.90 3.25 8 Tor @ 250 c/c 2.01
Y-Dir
Span aym = 0.024 aym.w.lx2 = 0.68 2.44 8 Tor @ 200 c/c 2.51
pt Provided = 0.19 %
Referring to IS: 456 -2000;Cl.23.2.1and FIG. 4
Where,
Effective Span (Lx) = centre to centre dist. of support = 4.66 M
Mod Factor= depending on pt provided =
Therefore,
dreqd. = #VALUE! mm.<Provided
O.K.
830729938.xls,S5 12/23/2024
PANEL LIST
1 Column1 Column1 Y
2 Y Y Column1
3 N N Y
4 N N
5
6
7 Y
8 N
9
2
3 Check Box 3
4
Y
5
Column1
Y Y Column1
N N Y
N
W
W
1
3
Column1
1
Column1
PANEL
a
b
c
d
0.028
0.037
Y
Effective Depth
Panel Type Lx (mm) Ly (mm) Overall Depth (mm) (mm) Drop (mm) Floor Finish (mm) Plaster (mm) Loading (t/m^2) Concrete (M)
One Way or k=1- pt=50*p*f Ast(cm^2/
Steel (Fe) Lx/Ly Two Way Coeff. Moment r=M/bd^2 4.6*r/fck p=1-sqrtk ck/Fe m run) Fs
axs Mx Supp.
axm Mx Span.
ays My Supp.
aym My Span.
Depth Mod. Depth
Factor Factor. dreqd. dprov. Checking
INPUT MATERIAL
INPUT PROPERTIES
OUTPUT
OR
POSITIVE
01.00 01.10 01.20 01.30 01.40 01.50 01.75 02.00 ALFAX
1 0.024 0.028 0.032 0.036 0.039 0.041 0.045 0.049 0.024
2 0.028 0.032 0.036 0.039 0.041 0.044 0.048 0.052 0.028
3 0.028 0.033 0.039 0.044 0.047 0.051 0.059 0.065 0.028
4 0.035 0.04 0.045 0.049 0.053 0.056 0.063 0.069 0.035
5 0.035 0.037 0.04 0.043 0.044 0.045 0.049 0.052 0.035
6 0.035 0.043 0.051 0.057 0.063 0.068 0.08 0.088 0.035
7 0.043 0.048 0.053 0.057 0.06 0.064 0.069 0.073 0.043
8 0.043 0.051 0.059 0.065 0.071 0.076 0.087 0.096 0.043
9 0.056 0.064 0.072 0.079 0.085 0.089 0.1 0.107 0.056
c) Loading:
S5 UDL for DL+LL ,w = 0.646 T/M2
M
d) Concrete Grade =M 20
6.12
e) Grade of steel= Fe 415
Ly=
From Table - 26 of IS: 456 - 2000,Moment Factors and subsequently Moments and reinforcements are
obtained as below:
Ast
Moments Reqd. Ast
Dir. Location Moment Factors Reinf. Provided
(T-M/M run) (cm2/ Prov.
Mrun)
Suppt. axs = 0.080 axs.w.lx2 = 0.83 3.68 8 Tor @ 200 c/c 2.51
X-Dir
Span axm = 0.058 axm.w.lx2 = 0.60 2.67 8 Tor @ 200 c/c 2.51
pt Provided = 0.24 %
Referring to IS: 456 -2000;Cl.23.2.1and FIG. 4
Where,
Effective Span (Lx) = centre to centre dist. of support = 4.00 M
Mod Factor= depending on pt provided =
Therefore,
dreqd. = #VALUE! mm.<Provided
O.K.
830729938.xls,S7 12/23/2024
Story Point Load FX FY FZ MX MY MZ
BASE 319 FDN 0.08 -0.93 83.69 0.951 0.092 0
BASE 320 FDN -0.09 -0.93 83.78 0.946 -0.102 0
BASE 321 FDN 0.26 1.07 74.7 -1.314 0.3 0
BASE 322 FDN -0.27 1.06 74.74 -1.308 -0.311 0
BASE 332 FDN -0.31 0.05 64.87 -0.22 -0.359 0
BASE 333 FDN 0.34 0.05 65.41 -0.215 0.381 0
BASE 334 FDN -0.21 -0.16 37.63 0.024 -0.251 0
BASE 335 FDN 0.2 -0.16 37.79 0.028 0.224 0
522.61