Bearing

Travelling ShaftNet Reaction Force Motor


Height Length Weight Power
Model
R1 R2 R3
H (mm) L (mm) KN KN KN KN (KW)
6000 16537 91 59 50 82 8
FJF-W-6000-2-30° 6500 17403 94 61 52 89 8
-600k 7000 18269 97 63 54 95 11
A A 3600 person/hours 7500 19135 100 66 56 101 11
L=α+5745=17437 +10
0
Speed : 0.5m/s 8000 20001 104 67 58 109 11
2688 α=1.732XH=11691 3057 100 8500 20867 107 69 60 115 11
Satety barrier 1400 1400
Openimg length LB≥(2300+S)*1.732+3057 9000 21733 110 72 63 122 11
(By customer’s expense) 1110 1110
500 6000 16137 95 62 53 90 11
B 800 800
R1 FJF-W-6000-2-30° 6500 17003 98 64 55 97 11
-800k 7000 17869 101 67 58 103 11

min300
7500 18735 104 69 60 110 15

1200
S
A 4800 person/hours
8000 19601 108 71 62 117 15

min2300
Speed : 0.5m/s
Anti-collision baffle 8500 20467 111 73 64 123 15

Travelling height H=6750±5


(By customer’s expense) 9000 * 21333 114 76 67 130 15

310
6000 16137 100 65 56 100 15
FJF-W-6000-2-30° 6500 17003 103 67 59 107 15
R3
-1000k 7000 17869 106 70 61 113 15
788 6000 person/hours 7500 18735 109 73 64 120 15

2530
500 Speed : 0.5m/s 8000 19601 113 75 66 127 16
995

R2 8500 20467 116 78 69 133 16


900

1400 50 9000 21333 119 80 71 140 22


2900
min1450
1200

Endurance (customer responsibility) min3000 Escalator shaft construction technical conditions


Oil water separator
1.When the escalator installed on the second floor above, pit cancelled, civil infrastructure and upper symmetry
min5200 2. a When the depth dimension is at least 2500 mm from the end of the handrail device, the step width is 1000 mm、
Exhaust hole installed outdoors
(By customer’s expense) 10218 800 mm、 600mm type, evacuation space width values ​were 1600mm、1400mm and 1200mm;
min2500 Evacuation space b When the depth dimension is at least 2000 mm from the end of the handrail device, the step width is 1000 mm、
(upper and lower 800 mm、600mm type, evacuation space width values ​were 2960mm、2560mm and 2160mm;
min2000 3.With the escalator handrail - any obstacle distance not less than 400 mm。
Less than 400 mm, provide safety signs head) A 4.Motor power supply single 380VAC±7%,50HZ,40A。
(By customer’s expense) Lighting power supply 220VAC,15A。
5.The user provides a grounding resistance not bigger than 4Ω grounding。
6.Power supply wiring can three-phase five wire system。
400

7.Thiscvltechnialconditsforecaltorisanmportanprtofheconstruionpla,mustberictlyobservd。
Ø100 Othermatsnometiondherin,pleasrfetoherlvantprovisnofatinlstadrGB1689-201。

min2760
min3990
8.Ifcivlnotacrdingtohecnditosandlyoutfheconstruion,auserisponibleforthecifaton,

100
The resulting consequences shall be borne by the user
80KN 9.Above the shaft size of any change, please inform me of the company in writing,
and change need to be recognised by my company。
Silica gel filled after installation 10.Truss on three sides decoration users themselves or contract separately。
(By customer’s expense) 200 40
Ground after installation
Confirm: The user totally agree according to the figure size
135

δ20*400*350
Confirm: Company seal>
300

(By customer’s expense)


Date:
310

Round steel Project name M.KSA-Nagran mall


or dovetail bolt (R45) Remark: Contract NO Lift type code
(By customer’s expense) FDF(SW)
It is upper part for the dynamic force 1.R1, R2, is the bearing capacity for single elevator, First
(single set) Embedded structure δ20X200X1400 and inlluminating mains entrance holeφ80 Round steel 4-φ16X150 Designer Escalator
Using double row and bearing capacity of double. Min500 or dovetail bolt
edition
(By customer’s expense) B (By customer’s expense) 2.When the step width is 600mm,lengthened 400mm on the machine。
Reviewer construction in 2020
(By customer’s expense)
Approved 2024/12/17 total 1 page Page 1
3.2 Levels。
1:6