Cast Steel Flange End Basket Strainers185 Mueller
Cast Steel Flange End Basket Strainers185 Mueller
Cast Steel Flange End Basket Strainers185 Mueller
Max. temp. can be limited by gasket • Tapped and plugged NPT drain on the strainer bottom enables easy self-cleaning on open
material. Consult factory. bottom baskets. Simply open the valve or plug on the outlet to flush accumulated particles.
• Bodies can be tapped for pressure gauges, or per customer requirement, consult factory.
185 Class 150
186 Class 300 Construction
• Cover is a flanged bolted design for easy basket removal.
Capacity
• Large bodies and generous sized baskets
• Minimum 6 to 1 ratio.
Steam Jacketing
Available on request, consult factory.
Baskets
Models 185, 186 STANDARD (WATER) STEAM RECOMMENDATION
MODEL SIZES MATERIAL OPENING MATERIAL OPENING
185, 186 11⁄2" – 4" 304SS .062 perf 304SS .045 perf
185, 186 5" and Up 304SS .125 perf Consult Factory
Pressure Drop
See Pressure Drop Charts in Technical Data section of the Mueller Steam Specialty
Engineering binder.
Mueller Steam Specialty product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure-
ments, please contact Mueller Steam Specialty Technical Service. Mueller Steam Specialty reserves the right to change or modify product design, construction,
specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Mueller Steam Specialty products
previously or subsequently sold.
A Watts Water Technologies Company USA: St. Pauls, NC • Tel. 1-800-334-6259 • Fax 1-800-421-6772 • www.muellersteam.com
ES-MS-185_186 1020 © 2010 Mueller Steam Specialty
IOM-MS-Simplex
Installat i o n , O p e r a t i o n a n d M a i n t e n a n c e
Simplex Basket Strainers
Cover Knobs Warning
O-Ring
Individuals performing removal and disassembly should be provided
Cover with suitable protection from possibly hazardous liquids.
Knob and clamp type quick opening covers should not be used for high
temperature service. Consult factory for recommendations.
Installation
Before installing the simplex basket strainer, be sure its pressure rating
O-Ring is correct for the system. If the end connections are threaded, be sure
the piping is straight and not at an angle or offset. If the strainer has
Body flanged ends, be sure the flanges of the connecting piping are square
Basket with the pipe so that no undue stresses are put on the strainer or pip-
ing when tightening flange bolts. Tighten bolts in sequence crossing
to opposites.
NPT Plug
Maintenance
For maximum efficiency, a differential pressure gauge installed across
Cover
Cover Bolts the inlet and outlet will indicate pressure loss due to clogging and
Gasket may be used, as a guide to determine when cleaning is required. If
the strainer is not set up for backwash cleaning, remove the cover
access to the basket. After cleaning, replace the basket in the same
position as before and tighten cover. Replace the gasket or O-ring if
necessary.
Keeping a spare, clean basket will minimize shut down time.
Spare Parts
To order replacement baskets or gaskets and O-rings, which are the
only items normally required, specify the following.
A. Size and model number of strainer or casting number as it appears
on the body of the strainer.
B. Specify service. For example: water, steam, gas, air, oil. The work-
Body ing pressure and temperature of the system and particle size to be
strained out should also be specified.
Basket
NPT Plug
Limited Warranty: Mueller Steam Specialty warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment.
In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge. This shall constitute the sole and exclusive remedy for breach of
warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including without limitation, lost profits or the cost of repairing or replacing other property which is
damaged if this product does not work properly, other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemical,
or any other circumstances over which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product. THIS WARRANTY IS IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Any implied warranties that are
imposed by law are limited in duration to one year.
Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow the exclusion or limitation of incidental or consequential damages. Therefore the above limitations
may not apply to you. This Limited Warranty gives you specific legal rights, and you may have other rights that vary from State to State. You should consult applicable state laws to determine your rights.
USA: 1491 NC Hwy 20 West, St. Pauls, NC 28384; www.muellersteam.com A Watts Water Technologies Company
Tel: 910-865-8241 Fax: 910-865-6220
Toll Free Phone 1-800-334-6259 Toll Free Fax: 1-800-421-6772
IOM-MS-Simplex 1020 EDP# 1915979 © 2010 Mueller Steam Specialty