1.A. Colomn Load
1.A. Colomn Load
COLOMN LOAD
Axial Force Pu = 3215 N
Moment Mu = 15514900 Nmm
Shrear Load Vu = 1739 N
1.B. BWRO
Thickness, ht = 12 mm
1.C. BASE PLATE
Yield stress of steel, fy = 250 MPa
p
Ultimate stress of steel, fu = 420 MPa
plate width, B= 210 mm
plate length, L= 200 mm
Thickness of plte tp = 14 mm
Concreate compressive strenght, f c' = 28 MPa
1.D. ANCHOR
b
Tensile stress at break of bolt, fu = 500 MPa
Yield stress of bolt anchor, fy = 440 MPa
Diameter of bolt anchor, d= 16 mm
Number of anchor, tensile side, nt = 2 bh
Number of anchor, compress side, nc = 2 bh
eccentricity of load, e = 4826 mm
Bolt distance to the center of the colomn section, f = 150 mm
Leng of bolt anchor embedded in concreate La = 200 mm
2.LOAD ECCENTRICITY
Tensile force on bolt anchor, Pt = Pu x ec/et = 3482.916667 N
Total compressive force on plate Puc =Pu + Pt = 6698 N
Total number of bolt anchor, n = nt + nc = 4 bh
h = h t - tf = 0 mm
et = f + h / 2 = 156 mm
et = f - h / 2 = 144 mm
3.TENSILE FORCE ON ANCHOR BOLTS
Tensile force in break of bolt, Tu1 = Pt / nct = 1741 N
Bolt breaking tensile stress, fuᵇ = 500 MPa
Bolt anchor cross-sectional area, Ab = π / 4 x d²= 201 mm2
Tensile strenght reduction factor, ɸt = 0.75
Nominal tensile resistance of bolt anchor Tn = 0.75 x Ab x fuᵇ = 75398 N
Bolt anchor tensile resistance, ɸ x Tn = 56549 N
Syarat yang harus dipenuhi :
Tu1 ≤ ɸ x Tn =
1741 < 56549 → SAFE (OK)