Combinador

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Typical applications:

• Satellite operators, VSAT,


teleports, and broadcasters
• High resilience RF
distribution, and optimum
satellite signal quality
• Redundancy applications for
remote satellite ports

50 - 1000 MHz Resilience from dual Signal monitoring Local Monitoring via
operating frequency redundant amplifiers via –20dB monitor port front panel status LEDs
range (OPT-R) for amplifier & PSU

Front view of similar model

Remote control & Dry contact alarm Reliability from dual


Compact housed in a monitoring via RJ45 port for amplifier &
1U high chassis redundant power supplies
Ethernet port with SNMP & power supply status
web browser interface

V 1.0 E&OE
Technical specifications and operating parameters

RF Parameters Environmental
Capacity 8 way Combiner Operating temperature 0 to 50˚C
50 to 1000MHz (IF)
Frequency Location Indoor use only

50Ω 50Ω 50Ω 75Ω 75Ω Storage temperature -20˚C to +75˚C


Connector &
impedances SMA N-Type BNC BNC F-Type Humidity 85% non-condensing. Relative Humidity.
Gain 0±1.0 dB Mean across band
Altitude 10,000 feet AMSL
Full band ±0.8 dB ±0.8 dB ±0.8 dB ±1.0 dB ±1.0 dB
Gain flatness
Any 36MHz ±0.25 dB ±0.25 dB ±0.25 dB ±0.3 dB ±0.3 dB
Power
Typical 21 dB 21 dB 21 dB 21 dB 21 dB
Input Return Loss PSU Power 85-264Vac 50-60Hz Fused 2A
Minimum 16 dB 16 dB 16 dB 16 dB 16 dB
BUC Power None
Typical 20 dB 20 dB 20 dB 20 dB 20 dB
Output Return Dual redundant with dual Diode OR. Not
PSU
Loss
Minimum 16 dB 16 dB 16 dB 16 dB 16 dB IEC hot-swap

2 ns maximum AC Consumption <15W At steady state


Full band
Group Delay
Variation 1 ns maximum
Any 36MHz

Amplification Single path amplifier (standard model) System Control & Alarms
Dual redundant amplifier Local Control Via Front Panel LCD
Options OPT-R Selectable hot or cold standby, 1:1 redundancy with auto switch-
over based on amplifier current monitoring. Via RJ45 Ethernet port, TCP/IP, SNMP & Web
Remote Control
Typical 30 dB 30 dB 30 dB 30 dB 30 dB browser interface.
Isolation at
70MHz Minimum 20 dB 20 dB 20 dB 20 dB 20 dB Indication LEDs with an SMA monitor port (on
Local front panel)
Typical 21 dB 21 dB 21 dB 21 dB 21 dB
Isolation at PSU and Summary dry contact alarms.
1000MHz 16 dB 16 dB 16 dB 16 dB 16 dB Monitoring
Minimum Alarms: Dry contact, change-over via 9-way D-
Noise Figure 24 dB Remote type. Full status and alarms are also available
via the Ethernet interface.
Output 1dB GCP +10 dBm

OIP3 +20 dBm

OIP2 +30 dBm Physical


-40 dBc With 2 equi-magnitude -13 dBm carriers. Total Dimensions 1U high x 350mm deep x 19” wide
3rd Order intermodulation level
power ‑10 dBm.
Input RF Power 16 dBm Absolute maximum Weight 3.05 kg

In Band Spurious < -80 dBm Colour RAL9003- White (semi-matte)


PRELIMINARY SPECIFICATIONS

Note 1: The specification is subject to regular reviews and will be updated from time to time as part of our continuing product development and improved spec accuracy.
Note 2: Operation beyond the quoted limits stated above may cause instantaneous and permanent damage.

ETL SYSTEMS LIMITED TELEPHONE FACSIMILE


Coldwell Radio Station +44 (0)1981 259020 +44 (0)1981 259021
Madley
Hereford EMAIL WEB
England HR2 9NE [email protected] www.etlsystems.com
V 1.0 E&OE