hw.1 / PLC_1 [CPU 1516-3 PN/DP] / Program blocks


Main [OB1]
Main Properties
General
Name Main Number 1 Type OB Language LAD
Numbering Automatic
Information
Title "Main Program Sweep (Cy‐ Author Comment Family
cle)"
Version 0.1 User-defined ID

Main
Name Data type Default value Comment
Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant

Network 1:

%I0.0 %I0.2 %Q0.0


"START BATTON" "SENSOR MIDD" "VOLV TANK 1"

%Q0.0
"VOLV TANK 1"

%I0.3
"SENSOR BELOW"

%I0.2 %I0.1 %Q0.1


"SENSOR MIDD" "SENSOR TOP" "VOLV TANK 2"

%Q0.1 %Q0.2
"VOLV TANK 2" "MIXER MOTOR"

%Q0.0 %I0.3 %Q0.3


"VOLV TANK 1" "SENSOR BELOW" "VOLV TANK 3"

%Q0.3
"VOLV TANK 3"
Totally Integrated
Automation Portal

HW.2 / PLC_1 [CPU 1516-3 PN/DP] / Program blocks


Main [OB1]
Main Properties
General
Name Main Number 1 Type OB Language LAD
Numbering Automatic
Information
Title "Main Program Sweep (Cy‐ Author Comment Family
cle)"
Version 0.1 User-defined ID

Main
Name Data type Default value Comment
Input
Initial_Call Bool Initial call of this OB
Remanence Bool =True, if remanent data are available
Temp
Constant

Network 1:

%Q0.0
%I0.0 %I0.5 "motpr of
"1st floor button" "1st floor sensor" elevator"

%Q0.1 %Q0.1
"1st floor led" "1st floor led"

%Q0.4
"the elevator is
working"

%I0.1 %Q0.0
"2nd floor %I0.4 "motpr of
button" "2nd floor sensor" elevator"

%Q0.2 %Q0.2
"2nd floor led" "2nd floor led"

%Q0.4
"the elevator is
working"

%Q0.0
%I0.2 %I0.3 "motpr of
"3rd floor button" "3rd floor sensor" elevator"

%Q0.3 %Q0.3
"3rd floor led" "3rd floor led"

%Q0.4
"the elevator is
working"

%Q0.0 %Q0.5
"motpr of "the elevator is
elevator" off"

You might also like