Configure A Catalyst 9600 Switch
Configure A Catalyst 9600 Switch
Contents
Introduction
Prerequisites
Requirements
Components Used
Background Information
Bring Up
Configure
Verify
Related Information
Introduction
This document describes the initial configuration and verification procedure to set up the Catalyst
9600 switch.
Prerequisites
Requirements
Ensure that the Chassis and Supervisor are installed as per the installation guides.
Components Used
The information in this document is based and configured on these software and hardware
versions:
Background Information
You can boot up, configure and verify Catalyst 9600 in three steps.
Bring Up
●Connect the console
●Power up the system
●Observe console messages
●Select configuration dialog option
Configure
●Device management
●Hostname
●Clock
●Save the configuration
Verify
●Software version and package
●System hardware, power, and so on.
●Management IP connectivity
●System health
●Time
Bring Up
● Connect the PC to Console of Catalyst 9600 with RJ45 or USB
● Power-up the system
● Observe console prints system hardware initialization and other information on the screen
Initial bootup:
Initializing Hardware...
Initializing Hardware......
System Bootstrap, Version 17.3.1r[FC2], RELEASE SOFTWARE (P)
Compiled 30-04-2020 12:00:00.00 by rel
Wait till you see the System Configuration Dialog box. Select the option No in order to enter
manual configuration mode and select Yes in order to terminate autoinstall, to get into the simple
manual configuration.
--- System Configuration Dialog ---
Configure
Note: Use the show running-config command at any point of time in "enable" mode to
check configured values.
Configure Management Port with an IP Address of your network and enable the port.
Switch#configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Switch(config)#interface gigabitEthernet 0/0
Switch(config-if)#ip address 10.122.186.8 255.255.255.240
Switch(config-if)#no shutdown
Configure a static route in order to reach the Default Gateway for Management network, use your
network IP and Gateway.
Switch(config)#line vty 0 4
Switch(config-line)#password cisco
Switch(config-line)#login
Transport input all allows all protocols (eg. ssh, telnet) in order to access the device through VTY
sessions.
Switch(config)#line console 0
Switch(config-line)#password cisco
Switch(config-line)#login
Switch(config-line)#exit
Configure a strong enable mode password.
*Nov 6 04:34:58.910: %SYS-6-CLOCKUPDATE: System clock has been updated from 10:05:58 utc Fri Nov
6 2020 to 10:04:58 utc Fri Nov 6 2020, configured from console by console.
*Nov 6 04:35:59.634: %SYS-5-CONFIG_I: Configured from console by console
*Nov 5 23:00:00.000: %SYS-6-CLOCKUPDATE: System clock has been updated from 10:06:19 utc Fri Nov
6 2020 to 04:30:00 utc Fri Nov 6 2020, configured from console by console.
Nov 5 23:00:00.000: %PKI-6-AUTHORITATIVE_CLOCK: The system clock has been set.
Configure hostname for the system.
Switch(config)#hostname Catalyst-9600
Save the configuration configured so far into startup-config.
Catalyst-9600#write memory
Building configuration...
[OK]
*Nov 5 16:11:46.061: %SYS-2-PRIVCFG_ENCRYPT: Successfully encrypted private config file
Verify
Check the software version on the system, observe the up-time, system details, and so on.
Catalyst-9600#show version
Cisco IOS XE Software, Version 16.12.03a
Cisco IOS Software [Gibraltar], Catalyst L3 Switch Software (CAT9K_IOSXE), Version 16.12.3a,
RELEASE SOFTWARE (fc1)
Technical Support: http://www.cisco.com/techsupport
Copyright (c) 1986-2020 by Cisco Systems, Inc.
Compiled Tue 28-Apr-20 09:37 by mcpre
A summary of U.S. laws governing Cisco cryptographic products may be found at:
http://www.cisco.com/wwl/export/crypto/tool/stqrg.html
------------------------------------------------------------------------------
Technology-package Technology-package
Current Type Next reboot
------------------------------------------------------------------------------
network-advantage Smart License network-advantage
dna-advantage Subscription Smart License dna-advantage
AIR License Level: AIR DNA Advantage
Next reload AIR license Level: AIR DNA Advantage
cisco C9606R (X86) processor (revision V00) with 1867991K/6147K bytes of memory.
Processor board ID FXS2302Q2EP
1 Virtual Ethernet interface
24 Forty/Hundred Gigabit Ethernet interfaces
48 TwentyFive Gigabit Ethernet interfaces
32768K bytes of non-volatile configuration memory.
16009160K bytes of physical memory.
11161600K bytes of Bootflash at bootflash:.
1638400K bytes of Crash Files at crashinfo:.
0K bytes of WebUI ODM Files at webui:.
--------------------------------------------------------------------------------
Auto abort timer: inactive
--------------------------------------------------------------------------------
Check the route for the Management VRF.
Catalyst-9600#show module
Chassis Type: C9606R
Catalyst-9600#show post
Stored system POST messages:
Switch C9606R
--------------
1) TestGoldPktLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
Port 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
2) TestOBFL ------------------------> U
3) TestThermal ---------------------> .
4) TestPortTxMonitoring:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U . U . U U U U U U U U U U . U
Port 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
1) TestOBFL ------------------------> U
2) TestFantray ---------------------> .
3) TestThermal ---------------------> .
4) TestScratchRegister -------------> .
module 4: SerialNo : CAT2252L0SU
1) TestOBFL ------------------------> U
2) TestFantray ---------------------> U
3) TestThermal ---------------------> .
4) TestScratchRegister -------------> U
1) TestGoldPktLoopback:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
Port 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
----------------------------------------------------------------------------
U U U U U U U U U U U U U U U U U U U U U U U U
2) TestOBFL ------------------------> U
3) TestThermal ---------------------> .
4) TestPortTxMonitoring:
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
----------------------------------------------------------------------------
. . U U U . U . U . . . U U . U U U U U U U U U
Port 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
----------------------------------------------------------------------------
U U . U U U U U U U U U U U . U . U U U U . . U
Catalyst-9600#show clock
*16:32:55.196 UTC Thu Nov 5 2020
Check the Power Supplies installed and their health.
Power Out of In
Mod Model No State Budget Instantaneous Peak Reset Reset
--- -------------------- -------- ------ ------------- ---- ------ -----
1 C9600-LC-24C accepted 300 0 0 300 10
3 C9600-SUP-1 accepted 950 0 0 950 202
4 C9600-SUP-1 accepted 950 0 0 950 202
6 C9600-LC-48YL accepted 300 0 0 300 10
FM1 C9606-FAN accepted 300 -- -- 300 --
--- -------------------- -------- ------ ------------- ---- ------ -----
Total allocated power: 2800
Total required power: 2800
Related Information
● Please follow the system management configuration guide for detailed configuration options.
● Technical Support & Documentation - Cisco Systems