1. Package Contents Per PoE port 3.

Hardware Introduction DIP Switch Mode Function


 Off: BT/PoH – 802.3bt PoE++/PoH + Legacy 95W
DIP Switch This mode makes the PoE++ Injector Hub operate
PoE output
Thank you for purchasing PLANET Industrial 4-port Gigabit 802.3bt BT /PoH as 802.3bt PoE++ type 4 PSE and PoH (Power
 ON: Force - 60w PoE output 3.1 Device Front Panel over HD-BASE-T) PSE with Legacy function.
PoE++ Injector Hub, IPOE-470/IPOE-470-12V. In the following sections,
the term “Industrial PoE++ Injector Hub” means the IPOE-470 or The front panels of the Industrial PoE++ Injector Hubs consist of
Dimensions 50 x 87.8 x 135 mm (W x D x H)
Ethernet interfaces and LED indicators. This mode makes the PoE++ Injector Hub operate
IPOE-470-12V. Force
Weight 537g 679g as 4-pair 60-watt force PoE PSE.
Open the box of the Industrial PoE++ Injector Hub and carefully unpack  Front View
Enclosure IP30 metal case
it. The box should contain the following items:
Installation DIN-rail kit and wall-mount kit P1 P2 Fault
P1 P2 Fault
PoE 1. After adjusting the DIP switch, the PoE++ Injector Hub
PoE 80W 160W 240W Usage
80W 160W 240W Usage
will stop and then work again.
Industrial PoE++ Injector Hub x 1 User’s Manual x 1

1 2 3 4
System:

ON
1 2 3 4
ON
2. Before connecting the “Data + Power” output port to
Power 1 (Green)

DIP
DIP
powered device (PD), make sure that it accepts PoE
Power 2 (Green) ON OFF PoE
ON OFF PoE

Force BT/PoH Mode


Force BT/PoH Mode
input via DIP switch setting to prevent damage.
Fault (Red)
LED Indicator Note 3. The legacy detection is to identify the PD devices that
PoE Usage:
80W/160W/240W (Amber) do not fully follow the IEEE 802.3af/at/bt standard and
802.3bt PoE++ Port: their unique electrical signatures to enable the PoE
PoE-in-use x 1 (Amber) injector to provide the power to those PD devices.
POE++ DATA
POE++ DATA
ESD Protection 6KV

Surge Protection 6KV


3.3 Device Top Panel
1 1

DIN-rail Kit x 1 RJ45 Dust Caps x 8 Wall-mount Kit x 1


Twisted-pair cable up to 100 meters (328ft) The upper panels of the Industrial PoE++ Injector Hubs consist of one
10BASE-T: 4-pair UTP Cat. 3, 4, 5, 5e, 6 2 2
terminal block connector within two power inputs.
Network Cable
100BASE-TX: 4-pair UTP Cat. 5, 5e, 6
1000BASE-T: 4-pair UTP Cat. 5e, 6 3
3

Power over Ethernet


Max. fault loading: 24V, 1A Max. fault loading: 24V, 1A
4
IEEE 802.3bt PoE++, 4-pair type 4 PSE 4
PoE Standard 1 2 3 4 5 6 1 2 3 4 5 6
Backward compatible with IEEE 802.3at PoE+ PSE
IPOE-470 IPOE-470-12V V1+ V2+ V1+ V2+

If any of these are missing or damaged, please contact your dealer PoE Power 802.3bt PoE++/PoH/Force End-span + Mid-span PWR1 Fault PWR2
DC Input:
48-54V , 5A max. PWR1 Fault PWR2
DC Input:
12-54V , 6A max.

immediately. Supply Type 802.3at PoE+ End-span/Mid-span


Figure 1: Figure 2:
Figure 3: IPOE-470 Top View Figure 4: POE-470-12V Top View
IPOE-470 Front View IPOE-470-12V Front View

-1- -3- -5- -7-

 System LEDs 3.4 Wiring the Power Inputs


2. Product Specifications Power Pin
Pair 1 End-span: 1/2(-), 3/6(+)
The terminal block connector on the top panel of Industrial PoE++
Pair 2 Mid-span: 4/5(+), 7/8(-) LED Color Function
Assignment Injector Hub is used for two DC redundant power inputs. Please follow
802.3bt/PoH: 1/2(-), 3/6(+), 4/5(+), 7/8(-)
P1 Green Lights to indicate DC power input 1 has power. the steps below to insert the power wire.
Model IPOE-470 IPOE-470-12V
Max. 90 watts to 802.3bt PoE++ PD P2 Green Lights to indicate DC power input 2 has power.
Hardware Specifications PoE Power Max. 95 watts to PoH PD
Output Max. 60 watts to force-powered PD Lights to indicate either power 1 or power 2 has When performing any of the procedures like inserting the
4-pair 10/100/1000BASE-T RJ45 Fault Red wires or tightening the wire-clamp screws, make sure the
Max. 36 watts to 802.3at PoE+ PD no power.
Copper Ports  Data input port 1 to Port 4 power is OFF to prevent from getting an electric shock.
Caution
 Data + PoE output port 1 to Port 4 80W, 160W, 240W
120W@48V DC input 60W@12V-23V DC input
PoE Power Lights to indicate the system consumes over 80-
240W@52V-54V DC 120W@24V-47V DC input
Removable 6-pin terminal block Budget (max.) PoE Usage Amber /160-/240-watt PoE power budget. 1. Insert positive and negative DC power wires into contacts 1 and 2 for
input 240W@48-54V DC input
Pins 1 and 2 for Power 1 Blinks to indicate the system consumes less than POWER 1, or contacts 5 and 6 for POWER 2.
Connector
Pins 5 and 6 for Power 2 Number of 80-/160-/240-watt PoE power budget.
Pins 4 and 4 for fault alarm devices that can 4
be powered  802.3bt PoE++ TP Interface LEDs
Data Rate 10/100/1000Mbps
Standards Conformance
Max. fault loading: 24V, 1A

LED Color Function


48~54V DC, 12~54V DC, 1 2 3 4 5 6
Power redundant power redundant power with reverse Regulatory Lights to indicate that the port is providing PoE
FCC Part 15 Class A, CE
Requirements with reverse polarity polarity protection Compliance 802.3bt in-line power to remote powered device. V1+ V2+
DC Input:

protection PoE++ Amber


PWR1 Fault PWR2 48-54V , 5A max.

IEC 60068-2-32 (free fall) PoE-in-Use Off to indicate that the port is not providing PoE
Stability Testing IEC 60068-2-27 (shock) in-line power to remote powered device. 2. Tighten the wire-clamp screws for preventing the wires from loos-
System ON without System ON without
IEC 60068-2-6 (vibration) ening.
Power loading loading
Consumption 48V DC: 1.92 watts/ 12V DC: 2.52 watts/8.6BTU
IEEE 802.3 Ethernet
(Ethernet Full 6.6BTU 24V DC: 3.6 watts/12.3BTU
IEEE 802.3u Fast Ethernet
3.2 DIP Switch Information
Loading) 54V DC: 2.16 watts/ 48V DC: 3.36 watts/11.5BTU Standards To meet the demand of various powered devices consuming stable PoE
IEEE 802.3ab Gigabit Ethernet
7.4BTU 54V DC: 3.24 watts/11.1BTU Compliance power, the PoE++ Injector Hub provides one DIP switch for three PoE
IEEE 802.3at Power over Ethernet Plus
IEEE 802.3bt Power over Ethernet Plus Plus operation mode options as shown in the following table.
Full loading Full loading
48V DC: 241 watts/ 12V DC: 72 watts/245.7BTU Environment
Power
1 2 3 4
ON

822.3BTU 24V DC: 131 watts/447BTU


Consumption Operating: -40~75 degrees C
54V DC: 244 watts/ 48V DC: 249 watts/ Temperature 1 2 3 4 5 6
DIP

(Ethernet Full Storage: -40~75 degrees C


832.6BTU 849.6BTU V1+ V1- V2+ V2-
Loading) ON OFF PoE
Power 1 Fault Power 2
54V DC: 251 watts/ Operating: 5~90% (non-condensing) Force BT/PoH Mode
856.5BTU Humidity
Storage: 5~90% (non-condensing) Figure 5: PWR1 & PWR2 pins of terminal block

-2- -4- -6- -8-


4.3 Side Wall-mount Plate Mounting
PWR1 and PWR2 must provide the same DC voltage
while operating with dual power input.
Caution

The wire gauge for the terminal block should be in the


range between 12 and 24 AWG.
Note

You must use the screws supplied with the wall-mounting


3.5 Grounding the Device brackets. Damage caused to the parts by using incorrect
Users MUST complete grounding wired with the device; otherwise, a Caution screws would invalidate your warranty.
sudden lightning could cause fatal damage to the device.

Max. fault loading: 24V, 1A

1 2 3 4 5 6

V1+ V2+
DC Input:
PWR1 Fault PWR2 48-54V , 5A max.

Earth Ground

EMD (Lightning) DAMAGE IS NOT CONVERED UNDER


WARRANTY.
Note

-9- - 11 -

 IPOE-470-12V
4. Installation 5. Three-View Diagram 163.00 Customer Support
This section guides you to installing the Industrial PoE++ Injector Hub Thank you for purchasing PLANET products. You can browse our online
 IPOE-470 FAQ resource on PLANET web site first to check if it could solve your
on the DIN rail and wall. Please read this chapter completely before
continuing. 163.00 issue. If you need more support information, please contact PLANET
40.00 28.00
support team.

Mounting Kit

Mounting Kit
DIN-Rail Kit
50.00 18.00 PLANET online FAQs:
In the installation steps below, this manual uses PLANET http://www.planet.com.tw/en/support/faq
IGS-801 8-port Industrial Gigabit Switch as an example. 40.00 28.00
Support team mail address:
The steps for PLANET Industrial Slim-type Switch,
[email protected]
Mounting Kit

Mounting Kit
DIN-Rail Kit

Industrial Media/Serial Converter and Industrial PoE

Rear View
Note 50.00 18.00 18.00

devices are similar. Copyright © PLANET Technology Corp. 2020.


Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
Rear View

18.00 All other trademarks belong to their respective owners.


4.1 DIN-rail Mounting Installation

V1+

1 2 3 4 5 6

Bottom View
PWR1

Max. fault loading: 24V, 1A


FCC Warning

Side View
Top View
97.10

Fault
87.80 87.80

V2+
PWR2
This device has been tested and found to comply with the limits

12-54V , 6A max.
DC Input:
1 for a Class A digital device, pursuant to Part 15 of the FCC Rules.
V1+

1 2 3 4 5 6

Bottom View
PWR1

These limits are designed to provide reasonable protection against


Max. fault loading: 24V, 1A

Side View
Top View

97.10
Fault

2
87.80 87.80 135.00
harmful interference when the equipment is operated in a commercial
V2+
PWR2
48-54V , 5A max.
DC Input:

environment. This equipment generates, uses, and can radiate radio

Front View

IPOE-470-12V
DATA
80W 160W 240W Usage
PoE
50.00

BT/PoH Mode
frequency energy and, if not installed and used in accordance with

PoE
Fault

OFF

POE++
P2

Force
1 2 3 4

ON
P1
ON DIP

135.00
the Instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
Front View

is likely to cause harmful interference in which case the user will be


IPOE-470
DATA
80W 160W 240W Usage
PoE

50.00
BT/PoH Mode
PoE
Fault

OFF

POE++

4.2 Wall-mount Plate Mounting


P2

required to correct the interference at his own expense


Force

1 2 3 4
ON
P1

ON DIP
Side View

WEEE Warning
Side View

Unit: mm
To avoid the potential effects on the environment and human
health as a result of the presence of hazardous substances in
Unit: mm Figure 7: IPOE-470-12V Three-View Diagram electrical and electronic equipment, end users of electrical and
electronic equipment should understand the meaning of the
Figure 6: IPOE-470 Three-View Diagram crossed-out wheeled bin symbol. Do not dispose of WEEE as unsorted
municipal waste and have to collect such WEEE separately.