0% found this document useful (0 votes)
8 views1 page

A B A B: Locker Locker

Uploaded by

opencityph
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
8 views1 page

A B A B: Locker Locker

Uploaded by

opencityph
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

A B A B

7730 7730

810 6130 790 810 6130 790

1 TO
LPPB
1 1 1
600

600
715

715
Refrigerator Refrigerator
Display Area Display Area
REF CO CO

LOCKER LOCKER
CKT
05

TO
LPPB

TO
LPPB
CO

CO
OFFICE TABLE 2 OFFICE TABLE 2
GLASS PANEL

GLASS PANEL
CO

TO
LPPB

CKT MEETING MEETING


7110

7110
04
TABLE TABLE

7110

7110
ACU

CO

CO
11000

11000

11000

11000
CKT
02

CO

OFFICE TABLE 1 OFFICE TABLE 1


GLASS PANEL

GLASS PANEL
CO

WATER CKT
WATER
DISPENSER 01 DISPENSER
WD

2 2 2 2
TO
CO
LPPB S3 S3
800

800
610

610
CO CO

CKT
06

FLOOR MOUNTED
SOCKET
WAITING WAITING
AREA AREA
RECEPTION DESK

RECEPTION DESK
CO
TO
LPPB
2565

2565
GLASS PANEL

GLASS PANEL
2490

2490
CKT
03
ACU

FLOOR MOUNTED
SOCKET

FLOOR MOUNTED FLOOR MOUNTED FLOOR MOUNTED


SOCKET SOCKET SOCKET

GLASS PANEL ENTRANCE GLASS PANEL GLASS PANEL ENTRANCE GLASS PANEL

2920 2920

2920 1700 3110 2920 1700 3110

7730 7730

A B A B

SCALE: 1:100 MTS. SCALE: 1:100 MTS.

ELECTRICAL ENGINEER : R.A. 9266 SEC. 33 PROJECT TITLE: PROJECT OWNER: ISSUES : SHEET CONTENT/DESCRIPTION: SHEET NO.

DRAWINGS AND SPECIFICATIONS DULY SIGNED ,STAMPED OR


PRC NO. SEALED, AS INSTRUMENTS OF SERVICE , ARE THE INTELLECTUAL NO. DATE: DESCRIPTION DRAWN BY :
PROPERTIES AND DOCUMENTS OF THE ARCHITECT , WHETHER
THE OBJECT FOR WHICH THEY
VALID UNTIL: ARE MADE IS EXECUTED OR NOT,IT SHALL BE UNLAWFUL 1 ISSUE FOR PERMIT CAD BY :

0 1
FOR ANY PERSON, WITHOUT THE CONSENT OF THE ARCHITECT
OR AUTHOR OF SAID DOCUMENTS TO
PTR NO. DUPLICATE OR TO MAKE COPIES FOR USE IN THE
REPETITION OF AND FOR OTHER PROJECTS OR BUILDINGS,
2 ISSUE FOR BID PROPOSED LIGHTING LAYOUT PLAN CHECKED BY :
WHETHER EXECUTED PARTLY OR IN A WHOLE.
PROPOSED POWER LAYOUT PLAN APPROVED BY :

OPEN CITY CONSTRUCTION INC.,


DATE:

ISSUED AT:
PD NO. 49
"PROTECTION OF INTELLECTUAL PROPERTY" NOVEMBER
14,1972.WORK OF ARTS , ARCHITECTURE, MODELS AND DESIGNS ARE
CREATIVE WORK AND CONSIDERED AS A PART OF THE INTELLECTUAL
3

4
ISSUE FOR CONSTRUCTIONS

ISSUE FOR REVISIONS DATE:


E
NAME AND SIGNATURE PROPERTY OF THE AUTHOR DULY PROTECTED UNDER PD 49.
RM. 201 CEMENTINA BUILDING A.ARNAIZ AVE., PASAY CITY TIN NO. LOCATION : VALERO, MAKATI,. METRO, MANILA 5 ISSUE FOR REVISIONS