Discovery Sounder Base
Discovery Sounder Base
Connect the device only to control panels using the Discovery protocol.
Warning
The Discovery Sounder Base requires compatible fi re alarm panel software to operate.
Please check with the panel manufacturer before installation.
Function
The Discovery Sounder Base combines a sounder, a detector base and a short circuit isola-
tor in one unit. It has up to 15 tone pairs, 7 volume settings, independent control of sounder
and fast turn-on functions. The configuration of the sounder is set by the control panel.
Please refer to the panel literature for details.
When the integral short circuit isolator operates, a yellow LED is visible through the
moulding opposite the XPERT card (see fig 1.)
Note: The Discovery Sounder Base is not suitable for outdoor use.
Mounting Instructions
The Discovery Sounder Base may be secured to a UK standard conduit box or surface
mounted (providing there is access through the surface for cabling). If a detector is fitted,
lock it if required by screwing in the grub screw in the detector with a 1.5mm hex driver
(part no 29600-095).
Wiring Details
Note: This product is polarity sensitive (supply reversal protected) and will not function if
wired incorrectly.
Terminate all loop cables in the two way terminal blocks. Connect the incoming loop
cables to L1 IN (–) and L2 (+) and the outgoing cables to L1 OUT (–) and L2 (+). Functional
earth or screen may be connected to the EARTH connection.
When using as a stand-alone unit, a cap is available (red cap part no 45681-293 or white
cap part no 45681-292) and is secured with a 1.5mm AF hexagon socket head screw. A
hexagonal driver (part no 29600-095) is available from Apollo.
L1 OUT
L2
EARTH
2
L2
L1 IN
Remote LED
1 Apollo Evacuation Tone * 567Hz for 0.5s, 850Hz for 0.5s T1 Apollo Alert Tone* 1s off, 1s 850Hz T0
2 Alternating -(Hochiki & Fulleon)* 925Hz for 0.25, 626Hz for 0.25s T12 Continuous (Hochiki & Fulleon)* 925Hz T11
5 Dutch Slow Whoop (sweep) * 500 Hz - 1200Hz for 3.5s, 0.5s off T3 Continuous* 850Hz T2
7 Swedish Fire Tone* 660 Hz, 150ms on, 150ms off T18 Swedish all clear signal-Continuous* 660Hz T17
7
8 Aus (fast rise sweep) 3 x (500Hz - 1200Hz for 0.5s), 0.5s off T6 Aus Alert Tone 420Hz, 0.625s, 0.625s off T5
9 NZ (slow rise sweep) 500Hz - 1200Hz for 3.75s, 0.25s off T7 NZ Alert Tone 420Hz, 0.625s, 0.625s off T5
10 US Temporal LF (ISO 8201) 3 x (970Hz, 0.5s on, 0.5s off) 1s off T19 Continuous 970Hz T13
11 US Temporal HF (ISO 8201) 3 x (2850Hz, 0.5s on, 0.5s off) 1s off T20 Continuous 2850Hz T15
13 Emergency Warning Siren N/A T10 Emergency Warning - All clear N/A T10
14 Evacuation Tone* 970Hz continuous T13 Alert Tone Silence for 1s, 970Hz for 1s T19
15 Apollo Evacuation Tone * 567Hz for 0.5s, 850Hz for 0.5s T1 Apollo Alert Tone 1s off, 1s 850Hz T0
* EN54 Compliant
Fault Finding Address Setting
The address of the Discovery Sounder Base is set using segments 1-7 of the DIL switch and
Problem Possible Cause are set to “0” (ON) or “1”, using a small screwdriver or similar tool. A complete list of address
No response or missing Incorrect address setting settings is shown below. If a detector is to be fitted, set the address as described on page 4.
Incorrect loop wiring (polarity reversed)
Failure to operate Control panel has incorrect cause and effect DIL switch DIL switch DIL switch DIL switch DIL switch
programming setting setting setting setting setting
addr 1234567 addr 1234567 addr 1234567 addr 1234567 addr 1234567
Technical Data
Operating voltage 17—28V DC 1 1000000 11 1101000 21 1010100 31 1111100 41 1001010
Switch on surge 1.2mA for 1s 2 0100000 12 0011000 22 0110100 32 0000010 42 0101010
Quiescent 400μA 3 1100000 13 1011000 23 1110100 33 1000010 43 1101010
Sounder Operating Variable 4 0010000 14 0111000 24 0001100 34 0100010 44 0011010
5 1010000 15 1111000 25 1001100 35 1100010 45 1011010
Nominal sounder output ± 3dB(A) at 28V 6 0110000 16 0000100 26 0101100 36 0010010 46 0111010
Level 1 (60dB(A))* 1mA 7 1110000 17 1000100 27 1101100 37 1010010 47 1111010
Level 2 (70dB(A)) 1.3mA 8 0001000 18 0100100 28 0011100 38 0110010 48 0000110
Level 3 (74dB(A)) 1.6mA 9 1001000 19 1100100 29 1011100 39 1110010 49 1000110
Level 4 (78dB(A)) 2.1mA 10 0101000 20 0010100 30 0111100 40 0001010 50 0100110
Level 5 (82dB(A)) 2.8mA
Level 6 (86dB(A)) 4mA 51 1100110 61 1011110 71 1110001 81 1000101 91 1101101
Level 7 (90dB(A)) 5.5mA 52 0010110 62 0111110 72 0001001 82 0100101 92 0011101
* Not EN54-3 compliant 53 1010110 63 1111110 73 1001001 83 1100101 93 1011101
IP rating IP21C 54 0110110 64 0000001 74 0101001 84 0010101 94 0111101
55 1110110 65 1000001 75 1101001 85 1010101 95 1111101
Sound pressure level information published in document PP2203 and isolator operation 56 0001110 66 0100001 76 0011001 86 0110101 96 0000011
information published in document PP2090, both available on request. 57 1001110 67 1100001 77 1011001 87 1110101 97 1000011
For further technical information please refer to PP2477. 58 0101110 68 0010001 78 0111001 88 0001101 98 0100011
59 1101110 69 1010001 79 1111001 89 1001101 99 1100011
Analogue Values 60 0011110 70 0110001 80 0000101 90 0101101 100 0010011
Analogue Value Status Analogue Value Status
101 1010011 106 0101011 111 1111011 116 0010111 121 1001111
0 Flash Memory Fail 17 Sounder Volume 1 102 0110011 107 1101011 112 0000111 117 1010111 122 0101111
103 1110011 108 0011011 113 1000111 118 0110111 123 1101111
1 Sounder Fail 18 Sounder Volume 2 104 0001011 109 1011011 114 0100111 119 1110111 124 0011111
4 General Fault 19 Sounder Volume 3 105 1001011 110 0111011 115 1100111 120 0001111 125 1011111
126 0111111
20 Sounder Volume 4
21 Sounder Volume 5
22 Sounder Volume 6
23 Sounder Volume 7
6 3
XPERT Card Addressing Commissioning
Select the desired address for the detector and remove the pips indicated in black. Remove It is important that the device be fully tested after installation. Many fault conditions are the
pips with a small screwdriver. result of simple wiring errors. Check all connections to the unit.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Setup and Test Mode
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
These modes allow volume adjustment and functional testing locally. In test mode no
volume adjustment is possible.
1
1
2
2
4
4
The required mode is entered via the control panel and is confi rmed by a red LED which
8
8
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
fl ashes once a second on the sounder. Sounder state (on/off) is controlled by placing a
magnet adjacent to the fl ashing LED. When all LEDs fl ash, withdraw the magnet. A suitable
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
extendable magnetic wand is available, part no. 29650-001.
16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
In setup mode the volume can be adjusted by holding the magnet adjacent to the fl ash-
1
1
ing LED and removing it at the desired volume level. If min or max volume is reached, the
2
2
4
4
8
8
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
LEDs stop fl ashing. To alter the direction of adjustment, remove the magnet for one second
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
and re-apply. Saving the volume setting is performed at the control panel.
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
1
1
2
2
4
4
8
8
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
1
2
2
4
4
8
8
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75
61 62 63 64 65 66 67 68 69 70 71 72 73 74 75
1
1
2
2
4
4
8
8
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
76 77 78 79 80 81 82 83 84 85 86 87 88 89 90
76 77 78 79 80 81 82 83 84 85 86 87 88 89 90
1
1
2
2
4
4
8
8
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
91 92 93 94 95 96 97 98 99 100 101 102 103 104 105
91 92 93 94 95 96 97 98 99 100 101 102 103 104 105
1
1
2
2
4
4
8
8
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
106 107 108 109 110 111 112 113 114 115 116 117 118 119 120
106 107 108 109 110 111 112 113 114 115 116 117 118 119 120
1
1
2
2
4
4
8
8
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
32
32
32
32
32
32
32
32
32
32
32
32
32
32
32
64
64
64
64
64
64
64
64
64
64
64
64
64
64
64
1
2
2
4
4
8
8
16
16
16
16
16
16
32
32
32
32
32
32
64
64
64
64
64
64
4 5