INT301 / INT302® Temperature monitor

for Pt100 or Pt1000 sensors


Application:
• motors • transformers
• pumps • gears / bearings

Functional description:
The INT30x devices can be pro- common to all three sensors
grammed to operate in two ways. and to the analogue input. The
Mode 1: An output relay is allo- alarm and trip points can be set
cated to each sensor; the individually for each sensor and
switching point can be individu- for the analogue input. The
ally set for each sensor. alarm relay signals sensor open
Mode 2: The relays are allocated or short circuit.
warning, trip and alarm functions

Special features:
• easy 2-key operation • 3 monitoring circuits in one
• analogue input device
INT30x Temp. monitor • analogue output (option: gal- • easy lead compensation
vanically isolated) • cascade configuration possible
• variable hysteresis • intelligent response to sensor
• password access possible faults

without galvanically All inputs are designed ommend to shield the sensor
isolated analogue for low voltage - do not con- cables and to ground unilater-
output nect to mains voltage. We rec- ally at the switching cabinet.

Technical data
Supply AC/DC 50/60Hz 24V ± 10% 3VA
Ambient temperature range -20...+60°C
Measuring range -50...+250°C (resolution 1K)
Accuracy ± 1% (of measuring range)
Temperature sensor (2-lead) Pt100 / Pt1000 acc. to EN 60751
Relay (3x change-over) AC 250V, max. 6A ohmic,
with galvanically 3A inductive, 300VA inductive
isolated analogue Mechanical service life approx. 1 mio. switching cycles
output Analogue output 0(4)...20mA, active,

Product group A
burden ≤ 500Ω
Analogue input 4...20mA, passive
Screw terminals ≤ 2.5mm2
Housing ABS
Connection diagram Protection class front mounted: IP65 (built-in)
acc. to EN 60529 housing: IP20
Mounting front panel mounting
Dimensions 74 x 34 x 85mm
Weight approx. 130g

Ordering information
Edition: 690.00145.2

INT301 for Pt100 sensors 20 A 501


INT301 with galvanically
isolated analogue output 20 A 501 S21
INT302 for Pt1000 sensors 20 A 502
INT302 with galvanically
isolated analogue output 20 A 502 S21
Transformer AC 50/60Hz
230V 3VA CD4200153F
Transformer AC 50/60Hz
Cut-out: 71 x 29mm
115V 3VA CD4200154F
Dimensions in mm Subject to technical modifications without notice

KRIWAN Industrie-Elektronik GmbH • Allmand 11 • D-74670 Forchtenberg • phone ++49-7947-822-0 • fax ++49-7947-1288 • e-mail: [email protected] • home: www.kriwan.com