CM3140 en Balancing Module - Three Point Circle Method 090611
CM3140 en Balancing Module - Three Point Circle Method 090611
130°
250°
Figure 2. Mark the respective positions of points A, B and C on the circle.
Start the rotor and run it at the same speed as for the initial run. Measure and record the new vibration amplitude as 0' + T1. Stop the rotor
and move the trial weight to position “B”. Using point “A” of our circle as the center point, draw a circle with a radius equal to 0' + T1 (in this
example, we will use 4 mils).
1
+T
0´
2
Start the rotor and run it at the same speed as for the initial run. Measure and record the new vibration amplitude as 0' + T2. Stop the rotor
and move the trial weight to position “C”. Using point “B” of our circle as the center point, draw a circle with a radius equal to 0' + T2 (in this
example, we will use 8 mils).
+T 2
0´
C
Start the rotor and run it at the same speed as for the initial run. Measure and record the new vibration amplitude as 0' + T3. Stop the rotor
and remove the trial weight. Using point “C” of our circle as the center point, draw a circle with a radius equal to 0' + T3 (in this example, we
will use 8 mils).
B
3
+T
0´
Note: The three circles drawn at “A”, “B” and “C” intersect at a common point “D”.
3
Draw a line from the center “0” of the original circle to point “D”, as shown. Label this line “T”. Measure the length of line “T” using the same
scale used in drawing the circles (in our example, line “T” is 5,25).
D
T
Figure 6. Draw a line from the center of the original circle "0" to point D.
• CW = TW (0'/T)
Where:
– CW = Correction weight
– TW = Trial weight
– 0' = The original unbalance reading
– T = The measured resultant vector
4
Using a protractor, measure the angle between line “T” and line “0A”. This measured angle is the angular location for the correction
weight, located relative to point “A” on the rotor. Attach the correction weight derived from your calculations to the rotor at the angular
position as determined above.