B217-DR Data Recorder – Technical Data

The B217-DR Data Recorder


is an indispensable measuring system for accurately
measuring transient & time phenomena of various
applications. It is a small and compact desk top device
containing a charge amplifier, AD-Converter and time
measuring system. It is software operated by our custom
made B3000 BWF Work Frame

System requirements:
- Win7 / Win10 operating system, MS Office
- B3000 BWF Ballistic Workframe
- B217 BWF Software Module

Maximum stackable desk top units: Example of measuring result, by showing filtered and
• 4 Analog Channels (pressure) unfiltered pressure curve in one graphic
• 8-time input channels (for 4 time or velocity
phenomena)
Desk Top Unit including:
• 1 Transient channel
• Amplitude resolution 16 Bit (18 Bit oversampling)
• Max. sampling rate 10MHz
• Input memory 2 MWords
• Voltage input range +/- 10 Volt
• Input impedance 100 kOhm/10pF
• 2-time input channels
• Power input DC 15-30 Volt, 15 Watt via external
power supply 85 - 265 V, 50/60 Hz
• Link connection to synchronize up to 4 B217-DR Selectable Digital Filters:
• 2 LAN interfaces min. 100 Mbit/s with built in switch • Bessel
• Butterworth
• Data transfer via optional W-LAN unit
• Moving Average
• Built in calibration/test signal • Others on Request
Charge input:
• 1 Charge input for a piezoelectric transducer
• Input range: +/- 50000 pC
• Frequency range: 250 kHz (-3dB)
• Drift: ≤ 0.05 pC/s
• Cut off Frequency > 0.01 kHz
Time Channel:
Example for CIP Measurement:
• Time measurement, 1 start and 1 stop input (1x max pressure / 1x gas pressure curve / 1x time/velocity):
• Counter resolution 0.05μs (20MHz)
• Software selectable signal conditioner
• TTL/Pulse mode for different sensors (e.g. light
screens, etc., ...)
• Contact mode for insulated start pin
• Piezo mode (charge input) for accelerometer and
blast wave sensor

Dimensions: 270x175x50mm
Example for NATO Measurement:
Weight: 1.8 kg
(2x max pressure / 2x gas pressure curve / 2x time/Velocity):

Subject to change without notice page 1 / 1 07/2024EN