RUNXIN

MULTIPORT
Hengshui Snowate Environmental
Technology Co., Ltd.

CONTROL VALVES

2024
EDITION FOR SNOWATE CATALOG

www.snowate.com
HENGSHUI SNOWATE
ENVIRONMENTAL
TECHNOLOGY CO., LTD.

A TRUSTWORTHY SOURCING EXPERT


ON WATER TREATMENT FACILITIES

As a senior sourcing expert on water treatment facilities and accessories, Hengshui


Snowate Environmental Technology Co., Ltd. has extensive water treatment expertise,
profound water treatment industry experience and a deep understanding of the
water treatment industry purchasing demands. As a consequence, we are capable of
providing one-stop purchase and technical support on water treatment facilities and
accessories according to our customers' applications, thereby helping our customers
to shorten the procurement cycle, reduce procurement costs and maximize economic
benefits.

We integrate upstream supply chain products of the water treatment industry. In


addition, we work with renowned suppliers and manufacturers. As a result, we can
continuously supply high-quality water treatment components and systems for
customers across the world to meet the needs of a Wide Range of Applications,
Thereby Optimizing Water Resources and Promoting The Sustainable Development of
The Global Environment.

02 www.snowate.com
Contents

I Product Description 04-12

Multiple-Valve-In-One 04
Structure – Features 06
Working Principle 08
Applications & Industry 10
Runxin Code System 12

II Control Valves 14-39

Manual Filter Control Valves 14


Automatic Filter Control Valves 16
Manual Softening Control Valves 19
Automatic Softening Control Valves 21
Continuous Water Supply Control Valves 26
P Series 33
Q Series 34
Floating Bed 35
Residential D Series 36
Special Application Control Valves 38
Bypass Valves Series 39

III Appendix 40

www.snowate.com 03
Multiple-Valve-In-One
Runxin Control valves structure is an initial international technology. It
has past International Patent Cooperation Treaty. The research report
indicates this product is creative, novel and practical in industry. It has
gotten patents in many countries such as USA, EU and so on.

High flatness ceramic Part balance pressure Signal collection points


moving disk and high structure can reduce the set on a circular surface
strength fixed disk pressure acting on the which can realize
guarantee excellent sealing surface and reduce accurate positioning.
sealing the rotational torque

04 www.snowate.com www.snowate.com
04 www.snowate.com
VS

RUNXIN MULTIPORT TRADITIONAL PIPELINE


CONTROL VALVES SYSTEM

Simple installation with Complex connections and


less leak points many leak points

Integrate multiple valves into one valve, which 5,7,11 and more valves pipe connections in
make the connection easier and more efficient filtering, softening and ion exchange systems
and significantly reduce leak risk . cause hard installation many potential leak points.

Easy Maintenance Hard Maintenance

Fewer connections make maintenance easy and Multiple connections make the leak risk increase.
fast. Just replace the worn accessory of Runxin Besides, the repair and maintenance will spend
control valves, which can save more costs and too many labor and downtime time costs.
increase efficiency.

Automatic Operation All-Manual Operation

Just set the process in advance, it can achieve Manually operate many valves open and close will
automatic operation. spend long time and easy to have internal water
mixing.

www.snowate.com www.snowate.com 05
www.snowate.com 05
Structure – Features

A
B

Hermetic Head Faces 8 7 8 6 7 5 6 4 5 3 4 2 3 1 2

Construction F F F

Because of good corrosion resistance,


E E E

Runxin control valve has a very good


application in Anion/Cation ion-exchange
system. D D D

Ceramic Moving Disk


C C C
C
i. Ceramic Disk is sintered at 1680 °C.
ii. Content : Al2O3 ≥ 95%
B B B

iii. HRA≥85°, Flatness≤0.0003 mm, Parallelism≤0.015 mm


iv. Acid and alkaline resistance: Ceramic has excellent stability against Inorganic acid and alkaline
at normal temperature.
A A A

8 7 8 6 7 5 6 4 5 3 4 2 3 1 2

High Strength Synthetic Fixed Disk

i. High Strength Synthetic material ensure the fixed disk resisting corrosion from many kinds acids
and strong alkalines except hot concentrated Nitric acid.
ii. The fixed disk is grinded to have same flatness as the ceramic moving disk to keep good and
reliable sealing. D
iii. Hermetic head faces construction has better ability to prevent damage from foreign substance
in the water.

Partly Balance Construction

For each softener valve, it adopts partly balance construction to prevent big torque as water
pressure increasing.

06 www.snowate.com www.snowate.com
A
B
Operate with Pressure
1

F
Runxin valve uses two high-flatness sealing disks closely located respectively. When
switch the working positions, it could operate with pressure.

While some other valves which uses soft sealing element like rubber parts, it can't operate
E

with pressure. It needs to shut off the inlet valve before switching.

C
C
No Hard Water Bypass Option
B

No Hard Water Bypass (NHWP) means the valve can internally prevent raw water from
getting into service lines during regeneration.
A

1
All Runxin valves can shut off the passage to outlet during regeneration except Model:
F79B, F82B, F92B.

Varieties of Specifications injector


The ratio of injector draw to total flow rate is around 25% to 35%. Each tank has a
specific injector matched.

www.snowate.com www.snowate.com 07
Working Principle

Using hermetic head faces theory, Runxin valve is designed to integrate multi-ports round closely to one
valve body. When the rotor rotates, some ports will be shut off and meanwhile some other ports will be
open, and thus the water will flow in and out this valve.

Construction
Runxin valve uses high-flatness moving disk and fixed disk to work as a valve. Fixed disk is fixed and moving disk is driven by
handle or motor to rotate closely over fixed disk. There are several blind via and through-holes on fixed disk and moving disk,
when moving disk stays on different positions of fixed disk, and then different flow passages will be formed:

For softener valves


These positions are Service, Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse.
For Filter valve
It has 3 positions: Service, Backwash and Fast Rinse.

8 7 6 5 4 3 2 1

Here, we take the F63 as example: E

D
6E 6D 6E 6D 6E 6D6E 6D 6D
6E 6E 6D6E 6D 6E 6E
6D
5A 5A - Blind hole
6F 6F 6F 6F 6F 6F
5B 5B - Passage to water inlet 6C 6C 6C 6F 6C 6C 6C 6F 6C 6F 6F 6F

4 3 2 1
6G 6G 6G 6G 6G
C

5C 5C - Blind Hole
F
6A 6A 6A 6A 6A 6B 6B
6B 6B 6B 6B 6B
6A 6A 6A 6A 6

6F - Passage to Brine Line connector


E Rotation Rotation
direction of moving disk direction of moving disk
6E - Passage to Bottom Strainer
A

6E 6D 6D - Passage to Injector
D
8 7 6 5 4 3 2 1

6F 6C 6C - Passage to Water
6G
Outlet
6A
6B
C

6B - Passage to
Bottom Strainer

6G - Passage to Drain Outlet


B
6A - passage to Top Strainer

Service Position Backwash Position


A

4 3 2 1

08
08 www.snowate.com
www.snowate.com www.snowate.com
Controller

Signal Controller Actuator Moving Locating Controller


Disk Device

The controller gets signal from Timer, Meter or Water Quality Detecting Instrument, and then will initiate the motor
to drive the actuator to rotate the moving disk, and when the moving disk rotates to the correct position, another
signal will be sent to the controller through the locating device, and the controller will stop the moving disk until
it finishes this step; When next new signal is received by the controller, the controller will drive the moving disk to
rotate to a new position and so on until all steps are finished and cycled.

Water passes this part. No water passes this part. (Same as below)

6E 6E6D 6D6E
6D 6D 6E 6E
6D 6E
6E6D 6D6E
6D 6D 6E 6E
6D 6E6D 6D6E 6D 6E 6E
6D 6E6D 6D

6C 6F 6C 6C 6C 6F 6C 6F 6F
6F 6C 6F 6C 6C
6C 6F 6C 6F 6F 6C 6F 6C 6C 6F 6C 6F 6F 6C 6C 6C
6G 6G 6G 6G 6G

6B 6B 6B 6B 6B 6B 6B 6B
6B 6B 6A
6B 6B 6A 6B6B 6A 6A 6A
6A 6A 6A 6A 6A 6A 6B 6B
6A 6B 6A 6B 6A 6A 6A

Rotation Rotation Rotation


direction of moving disk direction of moving disk direction of moving disk

Brine&Slow Rinse Position Brine Refill Position Fast Rinse Position

www.snowate.com www.snowate.com
www.snowate.com 09
09
Applications & Industry

Runxin control valves (filter valves and softening valves) are core component during filtering and softening
system. They are widely used in various fields to guarantee efficient and easier water treatment.

Filtering & Softening

Industrial Fields
Water filtering and softening for boiler, heat exchange equipment,
cooling system and RO system.

Agriculture
Water filtering and softening for crops and flowers irrigation,
livestock drinking, vegetables and fruits washing.

Residential
Water filtering and softening for drinking, bathing, cooking, as
well as for electric boilers, water heaters, underfloor heating and
other installations.

Commercial
Pre-filtering and softening of RO system for drinking and
domestic use. It can be used for swimming pool filtering.

10 www.snowate.com www.snowate.com
Process Water Treatment

Desalination (Pure and Ultra Pure Water)


Power station boiler make-up water, laboratory, electroplating plant,
integrated circuit manufacturing, pharmaceutical preparations,
biochemistry, drinking water, cosmetics and other fields.

Iron and manganese removal filtration


Mn Mn
Remove extra iron and manganese content in underground water
Mn
for domestic and industrial production use.

Deaeration
Deaeration for boiler water to prevent piping, water tank, and
other metal components from oxygen corrosion.

Defluoridation
Remove excess fluorine in underground water to protect people
from fluorosis.

www.snowate.com www.snowate.com 11
Runxin Code System

53610

5 3 6 10
Application Control Method Handle Type Or Maximum Flow Rate
Regeneration Type

1 Special Application 0 Semi-Automatic 0 No control Type 10 10 m3/h

4 Spare Parts 1 Manual Control 1 Manual control,


metal handle
5 Filter 2 Automatic Control,
LCD Display 2 Manual control,
6 Softener, plastic handle
Downflow regeneration 3 Automatic control,
LED Display 5 Automatic control,
7 Softener, time clock type
Upflow regeneration 4 Automatic Control,
Indicator Light 6 Automatic control,
8 Softener Display meter type
Downflow/Upflow
regeneration 5 Automatic Control, 7 Automatic control,
Digital Tube Display online monitoring
9 Floating Bed type
6 Automatic Control,
53610

WIFI Control

Examples
For 53610 control valve
5 means filter valve, 3 means LED display automatic control, 6 means meter type, 10 means water treatment capacity is 10 m3/h
That is,
53610 means meter type automatic filter valve with water treatment capacity of 10 m3/h.

12
12 www.snowate.com
www.snowate.com www.snowate.com
Special Application Control Valves

For code beginning with 1 are control valves for special applications, and for code
beginning with 4 are spare parts. The meaning of the first two digits refers to the
following chart.

For code beginning with 1

Code 11 13 15 17 18

Special Control valve for Control valve Control valve for Single valve with Single valve with
Applications fluoride removal for deaerator mixed bed system double tanks triple tanks

Control Valve Spare Parts

Code 41 42 43 44 45 46 47 48

Special Bypass Tee Brine Online Disk Controller Disinfection Salt Shortage
Valve Valve Valve Monitoring Filter Device Alarm Device
Applications Device
53610

For 17610 control valve


17 means single valve with double tanks, 6 means meter type automatic softener valve,
10 means water treatment capacity is 10 m3/h,
That is,
17610 means single valve with double tanks, meter type automatic softener valve with water treatment capacity of 10 m3/h.

www.snowate.com www.snowate.com
www.snowate.com 13
13
Manual Filter Control Valves

Structure & Performance Features


● Hermetic head faces structure.
● No hard water bypass and can operate with pressure.
● Manual regeneration. Handel could be rotated and assembled within 180°.

Applications
● Household Filter System (F56A/F56E/F56F).
● Activated carbon filter or sand filter system for RO pretreatment system.
● Swimming Pool Filter System (N56D/F77BS).
● N56D/F77BS can be used for Iron/Manganese Removal system if side
mount adapter is installed upside down.

Popular Models

51102 (F56E1) 51104 (F56A1)


Model 51202C (F56EC)
51202 (F56E2) 51204 (F56A2)

Water Capacity 2 m3/h 2 m3/h 4 m3/h

Handle Material Metal (E1) / Plastic (E2) Plastic handwheel Metal (A1) / Plastic (A2)

Mount Type Top Mount Top Mount, Side Control Top Mount

Inlet/Outlet 1/2"F (-1) or 3/4"F (-2) 1/2"F (-1) or 3/4"F (-2) 1"F

Drain 1/2"F (-1) or 3/4"F (-2) 1/2"F (-1) or 3/4"F (-2) 1"F

Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM

Riser Pipe 1.05" OD 1.05" OD 1.05" OD

Available Tank Size 6"–10" 6"–10" 6"–12"

Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C

Turbidity < 20 FTU < 20 FTU < 20 FTU

Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon

14 www.snowate.com www.snowate.com
51106 (F56F1)
Model 51204C (F56AC) 51204K (F56K)
51206 (F56F2)

Water Capacity 4 m3/h 4 m3/h 6 m3/h

Handle Material Plastic handwheel Plastic Metal (F1) / Plastic (F2)

Mount Type Top Mount, Side control Top Mount Top Mount

Inlet/Outlet 1"F 1"F 1"F Right in & Left Out

Drain 1"F 1"F 1"F

Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM

Riser Pipe 1.05" OD 1.05" OD 1"D-GB

Available Tank Size 6"–12" 6"–12" 6"–14"

Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C

Turbidity < 20 FTU < 20 FTU < 20 FTU

Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon

51110 (N56D1)
Model 51208 (F56L) 51215 (F77BS) 51240B (F112BS)
51210 (N56D2)

Water Capacity 8 m3/h 10 m3/h 15 m3/h 40 m3/h

Handle Material Plastic handwheel Metal (D1) / Plastic (D2) Plastic Handwheel Plastic handwheel

Mount Type Top Mount Top/Side Mount Top/Side Mount Side Mount

Inlet/Outlet 1.5"M 2"F 2"M DN65

Drain 1.5"M 2"F 2"M DN65

Base 4"-8UN 4"-8UN 4"-8UN -


Side Mount, Top and
Riser Pipe 1.25"D-GB / 1.66" OD 1.5"D-GB / 1.9" OD 1.5"D-GB / 1.9" OD
bottom DN80
Available Tank Size 10" – 24" 10" – 24" 30" – 36" 36" – 48"

Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C

Turbidity < 20 FTU < 20 FTU < 20 FTU < 20 FTU


Sand / Activated Sand / Activated Sand / Activated Sand / Activated
Media Carbon Carbon Carbon Carbon

www.snowate.com www.snowate.com 15
Automatic Filter Control Valves

Structure & Performance Features


● LED display, indication of long time power off and data saved after power off (Saved for
three days).
● No hard water bypass in rising cycle.
● With signal output connector and two modes (b-01 or b-02) are optional.
● Can set rinsing frequency F-00, realizing one time service and several times of backwash
and fast rinse.
● With remote control connector to recieve passive signals.
● With interlock connector to realize service simultaneously and rinse one by one.
● Start rising by days or hours.
● N77, F95 and F111 have two valve cores, one is for controlling inlet water, the other is
for outlet water.
● Time clock type or meter type is optional.
● N77/F95 with RS-485 port are optional.

Applications
● Residential Filter System (F71/F67).
● Activated carbon filter or sand filter system for RO pretreatment system.

Popular Models

53502 (F71B1)
Model 53502B (F71G1) 56603 (F67M)
53602 (F71B3)
Water Capacity 2 m3/h 2 m3/h 3 m3/h

Running Model Time Clock (B1) / Meter (B3) Time Clock Meter
Mount Type Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"M 3/4"M 3/4"M
Drain 3/4"M 3/4"M 3/4"M
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–10" 6"–10"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 20 FTU < 20 FTU < 20 FTU
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Transformer Output DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

16 www.snowate.com www.snowate.com
53504 (F67C1) 53504S (F67B1)
Model 53504B (F67G1) 53504C (F67I1)
53604 (F67C3) 53604S (F67B3)

Water Capacity 4 m3/h 4 m3/h 4 m3/h 4 m3/h


Time Clock (C1) Time Clock (B1)
Running Model / Meter (C3) / Meter (B3)
Time Clock Time Clock

Mount Type Top Mount Top Mount Top Mount Top Mount

Inlet/Outlet 1"F 1"F 1"F 1"F

Drain 1"F 1"F 1"F 1"F

Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM

Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD

Available Tank Size 6"–14" 6"–14" 6"–14" 6"–14"

Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C

Turbidity < 20 FTU < 20 FTU < 20 FTU < 20 FTU

Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Input Charge Hz 50–60 Hz Hz Hz
Transformer Output DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

53506S (F67B1-A) 53508 (F134A1) 53510 (N75A1)


Model 52504E (F67K)
53606S (F67B3-A) 53608 (F134A3) 53610 (N75A3)
Water Capacity 4 m3/h 4 m3/h 8 m3/h 10 m3/h
Time Clock (B1) Time Clock (A1) Time Clock (A1)
Running Model Time Clock
/ Meter (B3) / Meter (A3) / Meter (A3)
Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 1"M 1"F 1.5"M 2"M
Drain 1/2"M 1"F 1.5"M 2"M
Base 2.5"-8NPSM 2.5"-8NPSM 4"-8UN 4"-8UN
Riser Pipe 1.05" OD 1"D-GB 1.25"D-GB or 1.66" OD 1.5"D-GB or 1.9" OD
Available Tank Size 6"–14" 6"-14" 16"–18" 16"–21"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.2–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 20 FTU < 20 FTU < 20 FTU < 20 FTU
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Input Charge Hz 50–60 Hz Hz Hz
Transformer Output DC 12V/1.5A DC 12V/1.5A DC 24V/1.5A DC 24V/1.5A
www.snowate.com www.snowate.com 17
53510B (N75B1) 53515 (F99B1)
Model 53518 (N77B1)
53610B (N75B3) 53615 (F99B3)
Water Capacity 10 m3/h 15 m3/h 18 m3/h

Running Model Time Clock (B1) / Meter (B3) Time Clock (B1) / Meter (B3) Time Clock
Mount Type Top/Side Mount Top/Side Mount Top/Side Mount
Inlet/Outlet 2"M 2"M 2"M
Drain 2"M 2"M 2"M
Base 4"-8UN 4"-8UN 4"-8UN
Riser Pipe 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD
Available Tank Size 6"–21" 20"–30" 30"–36"
Working Pressure 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 20 FTU < 20 FTU < 20 FTU
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Transformer Output DC 24V/1.5A DC 24V/1.5A DC 24V/1.5A

53520 (F95B1) 53520T (F111B1) 53540B (F112B1) 53550 (F96B1)


Model
53620 (F95B3) 53620T (F111B3) 53640B (F112B3) 53650 (F96B3)

Water Capacity 21.6 m3/h 20 m3/h 40 m3/h 50 m3/h


Time Clock (B1) Time Clock (B1) Time Clock (B1) Time Clock (B1)
Running Model / Meter (B3) / Meter (B3) / Meter (B3) / Meter (B3)
Mount Type Side Mount Top Mount Side Mount Side Mount

Inlet/Outlet 2"M 2"M DN65 DN80

Drain 2"M 2"M DN65 DN80

Base - 4"-8UN - -
Side mount top and Side mount, top and Side mount, top and
Riser Pipe bottom distributor 2"M
2"D-GB
bottom distributor DN80 bottom distributor DN100
Available Tank Size 30"–36" 30"–36" 36"–48" 36"–48"

Working Pressure 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C

Turbidity < 20 FTU < 20 FTU < 20 FTU < 20 FTU

Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Input Charge Hz 50–60 Hz Hz Hz
Transformer Output DC 24V/1.5A DC 24V/1.5A DC 24V/4.0A DC 24V/4.0A

18 www.snowate.com www.snowate.com
Manual Softening Control Valves

Structure & Performance Features


● Hermetic head faces structure.
● No hard water bypass and can operate with pressure.
● Start regeneration by manual, and handle can be rotated 360° cycle.
● F64BC, F64AC could be side-operated.

Applications
● Residential Softener System(F64A/F64AC/F64B/F64BC).
● Softener system for RO.
● Boiler softener system; ion exchange units.

Popular Models

Model 61202 (F64B) 61202C (F64BC)

Water Capacity 2 m3/h 2 m3/h

Regeneration Type Downflow Downflow

Handle material Plastic handwheel Plastic handwheel

Mount Type Top Mount Top Mount

Inlet/Outlet 3/4"F 3/4"F

Drain 1/2"M 1/2"M


Brine Tank
3/8"M 3/8"M
Connector
Base 2.5"-8NPSM 2.5"-8NPSM

Riser Pipe 1.05" OD 1.05" OD

Available Tank Size 6"–10" 6"–10"

Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa

Water Temperature 5–50 °C 5–50 °C

Turbidity < 5 FTU < 5 FTU

www.snowate.com www.snowate.com 19
61104 (F64A1)
Model 61204C (F64AC) 61206 (N64F)
61204 (F64A2)

Water Capacity 4.5 m3/h 4.5 m3/h 8 m3/h

Regeneration Type Downflow Downflow Downflow

Handle material Metal (A1) / Plastic (A2) Plastic handwheel Plastic handwheel

Mount Type Top Mount Top Mount, Side control Top Mount

Inlet/Outlet 1"F 1"F 1.5"M

Drain 1/2"M 1/2"M 3/4"M

Brine Tank Connector 3/8"M 3/8"M 1/2"M

Base 2.5"-8NPSM 2.5"-8NPSM 4"-8UN

Riser Pipe 1.05" OD 1.05" OD 1.25"D-GB

Available Tank Size 6"–16" 6"–16" 6"–21"

Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C

Turbidity < 5 FTU < 5 FTU < 5 FTU

Model 61210 (N64D) 61215 (F77AS) 61240B (F112AS)

Water Capacity 10 m3/h 15 m3/h 40 m3/h

Regeneration Type Downflow Downflow Downflow

Handle material Plastic handwheel Plastic handwheel Plastic handwheel

Mount Type Top/Side Mount Top/Side Mount Side Mount

Inlet/Outlet 2"M 2"M DN65


2"M, connect 1.5"M current
Drain 1"M
limiting parts
DN65

Brine Tank Connector 1/2"M 3/4"M 3/4"M

Base 4"-8UN 4"-8UN -


Side mount, top and bottom
Riser Pipe 1.5"D-GB 1.5"D-GB or 1.9"OD
distributor DN80
Available Tank Size 6"–21" 30"–36" 40"–48"

Working Pressure 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C

Turbidity < 5 FTU < 2 FTU < 5 FTU

20 www.snowate.com www.snowate.com
Automatic Softening Control Valves

Structure & Performance Features

● LED display, long time power off indication and data will be saved for three days after power off.

● No hard water bypass in regeneration cycle (except F92 and F130).

● With signal output connector, remote handling connector which can receive passive signal.

● With interlock connector which can realize service simultaneously and regeneration one by one.

● N77, F95, F111 and F99 adopt ball valve for brine drawing and refill.

● Time clock regeneration option: by days or by hours; Meter valve regeneration option: Meter Delayed (A-01),
Meter Immediate (A-02), Intelligent Meter Delayed (A-03), intelligent Meter Immediate (A-04).

● Up-flow control valve can set interval backwash times F-00, which can realize several times service and one time backwash.

● N77, F95 and F111 have two valve cores, one is for controlling inlet water and brine drawing, another is for outlet water.

● N77 and F95 with RS-485 port are optional.

Applications

● Residential Softener Systems (F63/F65/F68/F69).


● Softener for RO pretreatment System.
● Boiler Softening System, lon exchange system.

Notes
● The model with a “S" means the valve with manual operation function.

● N77,F95,F111 brine refilled while service, brine refilling controlled by


electronic ball valve.

● F63, F65, F68 and F69 have a variety of appearances optional.

● N74B is optional which can be top or side-mounted.

www.snowate.com www.snowate.com 21
63502 (F65B1) 63502B (F65G1) 73502 (F69A1)
Model
63602 (F65B3) 63602B (F65G3) 73602 (F69A3)
Water Capacity 2 m3/h 2 m3/h 2 m3/h

Running Model Time Clock (B1) / Meter (B3) Time Clock (G1) / Meter (G3) Time Clock (A1) / Meter (A3)
Regeneration Type Downflow Downflow Upflow
Mount Type Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"F 3/4"F 3/4"F
Drain 1/2"M 1/2"M 1/2"M
Brine Tank
3/8"M 3/8"M 3/8"M
Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–10" 6"–10"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–45 °C 5–45 °C 5–45 °C
Turbidity < 5 FTU < 5 FTU < 2 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

73502B (F69G1) 63503 (F117A1) 63504 (F63C1)


Model
73602B (F69G3) 63603 (F117A3) 63604 (F63C3)
Water Capacity 2 m3/h 2 m3/h 4 m3/h

Running Model Time Clock (G1) / Meter (G3) Time Clock (A1) / Meter (A3) Time Clock (C1) / Meter (C3)
Regeneration Type Upflow Downflow Downflow
Mount Type Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"F 3/4"F 1"M
Drain 1/2"M 3/4"M 1/2"M
Brine Tank
3/8"M 3/8"M 3/8"M
Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–10" 6"–14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 2 FTU < 5 FTU < 5 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

22 www.snowate.com www.snowate.com
63504B (F63G1) 63504C (F63I1) 63504S (F63B1)
Model
63604B (F63G3) 63604C (F63I3) 63604S (F63B3)
Water Capacity 4 m3/h 4 m3/h 4 m3/h

Running Model Time Clock (G1) / Meter (G3) Time Clock (I1) / Meter (I3) Time Clock (B1)/ Meter (B3)
Regeneration Type Downflow Downflow Downflow
Mount Type Top Mount Side Mount Top Mount
Inlet/Outlet 1"M 1"M 1"M
Drain 1/2"M 1/2"M 1/2"M
Brine Tank
3/8"M 3/8"M 3/8"M
Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–14" 6"–14" 6"–14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 5 FTU < 5 FTU < 5 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

73504 (F68C1) 73504B (F68G1) 73504S (F68A1)


Model
73604 (F68C3) 73604B (F68G3) 73604S (F68A3)
Water Capacity 4 m3/h 4 m3/h 4 m3/h

Running Model Time Clock (C1) / Meter (C3) Time Clock (G1) / Meter (G3) Time Clock (A1) / Meter (A3)
Regeneration Type Upflow Upflow Upflow
Mount Type Top Mount Top Mount Top Mount with handwheel
Inlet/Outlet 1"M 1"M 1"M
Drain 1/2"M 1/2"M 1/2"M
Brine Tank
3/8"M 3/8"M 3/8"M
Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–14" 6"–14" 6"–14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 2 FTU < 2 FTU < 2 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

www.snowate.com www.snowate.com 23
63505 (F116A1) 73505 (F92A1)
Model F116E3 F130A3
63605 (F116A3) 73605 (F92A3)
Water Capacity 4 m3/h 5 m3/h 5 m3/h 4.7 m3/h
Running Model Time Clock (A1) / Meter (A3) Meter Meter Time Clock (A1) / Meter (A3)
Regeneration Type Downflow Downflow Downflow Upflow
Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 1"M 1"M 1"M 1"M
Drain 3/4"M 3/4"M NPT 3/4" 3/4"M

Brine Tank Connector 3/8"M 3/8"M 3/8"M 3/8"M

Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM


Riser Pipe 1.05" OD 1.05" OD 1"D-GB 1"D-GB
Available Tank Size 6"–14" 10"–20" 7"–22" 9"–16"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 5 FTU < 5 FTU < 5 FTU < 2 FTU
AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V /
Input Charge Hz Hz 50–60 Hz
AC 100V – 240V / 50–60 Hz

Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/2A DC 12V/2.0A

63508 (F133A1) 63510 (N74A1) 63510B (N74B1)


Model 73605E (F92E3)
63608 (F133A3) 63610 (N74A3) 63610B (N74B3)
Water Capacity 5 m3/h 8 m3/h 10 m3/h 10 m3/h
Time Clock (A1) / Meter Time Clock (A1) / Meter Time Clock (B1) / Meter
Running Model Meter
(A3) (A3) (B3)
Regeneration Type Upflow Downflow Downflow Downflow
Mount Type Top Mount Top Mount Top Mount Top/Side Mount
Inlet/Outlet 1"M 1.5"M 2"M 2"M
Drain NPT 3/4" 3/4"M 1"M 1"M
Brine Tank Connector 3/8"M 1/2"M 1/2"M 1/2"M
Base 2.5"-8NPSM 4"-8UN 4"-8UN 4"-8UN
Riser Pipe 1"D-GB 1.25"D-GB or 1.66" OD 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD
Available Tank Size 7"–22" 16"–18" 20"–21" 20"–21"
Working Pressure 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–45 °C 5–45 °C
Turbidity < 2 FTU < 5 FTU < 5 FTU < 5 FTU
AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V /
Input Charge Hz Hz Hz 50–60 Hz
Output Charge DC 12V/1.5A DC 24V/1.5A DC 24V/1.5A DC 24V/1.5A

24 www.snowate.com www.snowate.com
63515 (F99A1) 73515 (F99D1) 63518 (N77A1) 63520 (F95A1)
Model
63615 (F99A3) 73615 (F99D3) 63618 (N77A3) 63620 (F95A3)
Water Capacity 15 m3/h 15 m3/h 18 m3/h 21.6 m3/h
Time Clock (A1) / Meter Time Clock (D1) / Meter Time Clock (A1) / Meter Time Clock (A1) / Meter
Running Model (A3) (D3) (A3) (A3)
Regeneration Type Downflow Upflow Downflow Downflow
Mount Type Top/Side Mount Top/Side Mount Top/Side Mount Side Mount
Inlet/Outlet 2"M 2"M 2"M 2"M
Drain 1.5"M 1.5"M 1.5"M 1.5"M

Brine Tank Connector 3/4"M 3/4"M 3/4"M 3/4"M

Base 4"-8UN 4"-8UN 4"-8UN -


Side mount, top and
Riser Pipe 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD
bottom distributor 2"M
Available Tank Size 30" 30" 30"–36" 36"–40"
Working Pressure 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 5 FTU < 2 FTU < 5 FTU < 5 FTU
AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Input Charge 50–60 Hz Hz Hz Hz
Output Charge DC 24V/1.5A DC 24V/1.5A DC 24V/1.5A DC 24V/1.5A

63520T (F111A1) 73520 (F95D1) 63540B (F112A1) 63550 (F96A1)


Model
63620T (F111A3) 73620 (F95D3) 63640B (F112A3) 63650 (F96A3)
Water Capacity 21.1 m3/h 21.6 m3/h 40 m3/h 50 m3/h
Time Clock (A1) / Meter Time Clock (D1) / Meter Time Clock (A1) / Meter Time Clock (A1) / Meter
Running Model (A3) (D3) (A3) (A3)
Regeneration Type Downflow Upflow Downflow Downflow
Mount Type Top Mount Side Mount Side Mount Side Mount
Inlet/Outlet 2"M 2"M DN65 DN80
Drain 1.5"M 1.5"M DN65 DN80
Brine Tank Connector 3/4"M 3/4"M 3/4"M 3/4"M
Base 4"-8UN - - -
Side mount, top and Side mount, top and Side mount, top and
Riser Pipe 2"D-GB
bottom distributor 2"M bottom distributor DN80 bottom distributor DN100
Available Tank Size 36"–40" 36"–40" 40"–48" 60"–63"
Working Pressure 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 5 FTU < 2 FTU < 5 FTU < 5 FTU
AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz

Output Charge DC 24V/1.5A DC 24V/1.5A DC 24V/4.0A DC 24V/4.0A

www.snowate.com www.snowate.com 25
Continuous Water Supply Control Valves

One in Service One Standby – One Valve on Duplex Tank


To satisfy markets continuous water supply requirements, Runxin develop
the first control valve, which can control two tanks one time to achieve one
in service and one standby and guarantee continuous water supply.

This system contains one control valve and two tanks, it can achieve
downflow or upflow regeneration through switch program. Besides, it
adopts top or side mount method according to different output and tank
structure.

This structure can achieve max. output 3.5 m3/h, 6 m3/h, 10 m3/h.

Technical Performance

Item Requirements

Water Pressure 0.2–0.6 MPa


Working Condition
Water Temperature 5–50 °C

Environment Temperature 5–50 °C

Working Environment Relative Humidity ≤95% (25 °C)

Electrical Facility AC 100V – 240V / 50–60 Hz

Water Turbidity Upflow regeneration < 2FTU | Downflow regeneration < 5FTU


First Grade Na+:
Water Hardness
93610/93606 < 15 mmol/L | 17610/17606 < 6.5 mmol/L
Inlet Water Quality Free Chlorine < 0.1 mg/L

Iron2+ < 0.3 mg/L

CODMn < 2 mg/L (O2)

Notes

● First grade Na refers to First grade NA ion exchanger

● When the turbidity exceeds the working condition, a filter should be installed on the inlet of control valves.

● When the water hardness exceeds the working condition, the hardness of treated water can not meet the
needed requirements (for example 0.03 mmol/L for boil water), you should adopt secondary softening.

26 www.snowate.com www.snowate.com
17603 17603 (F73) 17606 (F98A) 17606T (F137) 17610 (F88A) 17610T (F135A)

Water Capacity 3.5 m3/h 6 m3/h 6 m3/h 10 m3/h 10 m3/h

Running Model Meter Meter Meter Meter Meter


Regeneration Type Upflow/Downflow Upflow Downflow Upflow Downflow
Mount Type Top Mount Side Mount Top Mount Side Mount Top Mount
Inlet/Outlet 1"M 1"M 1"M 1.5"M 1.5"M
Drain 1/2"M 3/4"M 3/4"M 1"M 3/4"M

Brine Tank Connector 3/8"M 1/2"M 1/2"M 1/2"M 1/2"M

Base 2.5"-8NPSM - 4"-8UN - 4"-8UN


Side mount, Side mount,
1.5"D-GB 1.5"D-GB or
Riser Pipe 1.05" OD top and bottom top and bottom
(32 mm OD) 1.9"OD
distributor 1"M distributor 1.5"M
Available Tank Size 12"-14" 20"–21" 16"–24" 20"–30" 20"–30"
Turbidity < 2 FTU or < 5 FTU < 2 FTU < 5 FTU < 2 FTU < 5 FTU

One in Service One Standby – Floating Bed

Model 93606 (F98C) 93610 (F88C)

Water Capacity 6 m3/h 10 m3/h

Running Model Meter Meter


Regeneration Type Upflow Upflow
Mount Type Side Mount Side Mount
Inlet/Outlet 1"M 1.5"M
Drain 3/4"M 1"M
Brine Tank Connector 1/2"M 1/2"M
Base - -
Riser Pipe Side mount, top and bottom distributor 1"M Side mount, top and bottom distributor 1.5"M

Available Tank Size 14"–16" 20"–21"


Turbidity < 2 FTU < 2 FTU

www.snowate.com www.snowate.com 27
One in service and one standby fixed bed system
17610/17606

Tank U2 in service and Tank U1 in standby Tank U1 in service and Tank U2 in Brine & Slow
Rinse (Upflow regeneration)

Tank U2 in Service and Tank U1 in fast rinse Tank U1 in service and Tank U2 in brine infill

Tank U1 in Service and Tank U2 in Backwash Tank U1 in Service and Tank U2 in Standby

2828www.snowate.com
www.snowate.com www.snowate.com
Control valve for floating bed system
93610/93606

Tank U1 in service and Tank U2 in standby Tank U2 in service and Tank U1 in Brine & Slow Rinse

Tank U1 in Service and Tank U2 in fast rinse Tank U2 in service and Tank U1 in brine infill

Tank U2 in Service and Tank U1 in Setting Bed Tank U2 in Service and Tank U1 in Standby

www.snowate.com www.snowate.com2929
www.snowate.com
One in Service One Standby – Two Valve and Two Tank

F92A3 F92A3
5–6 m3/h
● Suitable for 5-6 m3/h Continuous Water Supplying
● Two F92A3/F130A3 and DN25 Three-way Electronic Bal
Valve (Four Core Plug)

● Two F92A3/F130A3 are interlocked as one system, and set


C-02 (a connection for one in service one standby softening system)

10–20 m3/h
● Suitable for 10-20 m3/h Continuous Water Supplying
● Two N74A3/F99A3/N77A3/F95A3/F111A3 and F80
● Two valves are interlocked as one system, and set the system to
A-02 and b-01; Connect the signal output connector with the
control wire of F80.
● When the flow of working valve reduces to 0, the control valve
regenerates F80 switches by the signal outlet connector controlling,
the other valve turns to service.
● If the other valve is in regeneration, because of the function of interlock,
the working valve still in service.

1# Valve
Main Control Board NC
Blue COM
Black
1#
NO F80 Valve
Main Control Board
Interlock Power cord
2# Valve
Cablel
Main Control Board NC
Blue COM
Black
2# -24DC
NO
+24VDC

40–50 m3/h
● Suitable for 40–50 m3/h Continuous Water Supplying
● Two F112A3/F96A3 and Two DN25 Electronic Ball Valves
● Two valves are connected to signal line of one in service and one
standby system (interlock wire), and set the system to C-02 (One
in Service One Standby System).
● Ordinary F112A3/F96A3 needs to replace brine draw copper tube
and install DN25 ball valve with it.
● Continuous water supplying, one valve in service, the other valve
standby.

30
30 www.snowate.com
www.snowate.com www.snowate.com
Two in Service One Standby

● One valve controls three tanks, two tanks supply with softened water in series, the other tank standby to achieve water supply continuously.

● When service finishes, the first grade in series tums to regenerate, the second grade tums to the first grade and supplies with softened water
together with the standby tank as the second grade in series, which greatly improves the resin efficiency, saves water and salt.

● Regeneration tank keeps standby after switch and starts fast rinse before service.

● Only need one brine tank. Inlet


Outlet
● It adopts hermetic head faces structure with ceramic sealing, reliable and duration.

● Up-flow or down-flow regeneration is optional by program.

● Raw water or softened water for regeneration is optional by changing the moving disk.

● Remove one tank to make the system as one in service one standby system.

● There is always two tanks in service in series which could treat the raw water with high
hardness. It has backwash function, which could be used in high turbidity application
which floating bed system can' t be used.

● Suitable for treat high hardness water and continuous water supplying application Right Tank
Middle tank
left tank

18604A (F118A)
Model 18601B (F120B)
18604B (F118B)
Water Capacity 4 m3/h 1.5 m3/h

Running Model Meter Meter


Regeneration Type Downflow/Upflow Downflow/Upflow
Mount Type Top Mount Top Mount
Inlet/Outlet G1" G3/4"
Drain NPT 3/4" NPT 3/4"
Brine Tank Connector G3/8" G3/8"
Base 3 × 2.5"-8NPSM 3 × 2.5"-8NPSM
Riser Pipe 3 × 1.05" OD 3 × 1.05" OD
Available Tank Size 10"–18" 10"–12"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C

Downflow < 5 FTU Downflow < 5 FTU


Turbidity
Upflow < 2 FTU Upflow < 2 FTU

Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz


Transformer Output DC 12V/2A DC 12V/2A

Note: F118A raw water regeneration mode; F118B soft water regeneration mode.

www.snowate.com www.snowate.com
www.snowate.com 31
31
Softener Flow Chart
Inlet Inlet Inlet
Outlet Outlet Outlet
Softening
Inlet Inlet Inlet
Outlet Outlet Outlet

Right Tank Right Tank Right Tank


Middle tank Middle tank Middle tank
left tank Right Tank left tank Right Tank left tank Right Tank
Middle tank Middle tank Middle tank
left tank left tank left tank

Left tank + middle tank in serial service, Middle tank + right tank in serial service, Right tank + left tank in serial service,
right tank regeneration and standby left tank regeneration and standby middle tank regeneration and standby

Regeneration It takes left tank and middle tank in serial service and right tank regeneration as sample.

Left tank + middle tank in serial service, Left tank + middle tank in serial service, Left tank + middle tank in serial service,
right tank backwash right tank upflow brine draw right tank downflow brine draw

Inlet Inlet Inlet


Outlet Outlet Outlet
Inlet Inlet Inlet
Outlet Outlet Outlet

Right Tank Right Tank Right Tank


Middle tank Middle tank Middle tank
left tank Right Tank left tank Right Tank left tank Right Tank
Middle tank Middle tank Middle tank
Inlet
Inlet Inlet
left tank left tank left tank Outlet
Outlet Outlet
Inlet Inlet Inlet
Outlet Outlet Outlet

Right Tank Right Tank Right Tank


Middle tank Middle tank Middle tank
left tank Right Tank left tank left tank Right Tank
Right Tank
Middle tank Middle tank Middle tank
left tank left tank left tank
Left tank + middle tank in serial service, Left tank + middle tank in serial service, Left tank + middle tank in serial service,
right tank fast rinse right tank standby right tank brine refill

32 www.snowate.com www.snowate.com
P Series

Structure & Performance Features


● Locate by optocoupler, more stable performance. F63P, F67P and F68P adopt the same locating board, while F65P, F69P
and F71P use the same locating board. They all use the same main control board.

● Hermetic head faces structure, no hard water bypass during regeneration cycle.

● When power on, program run one cycle then locate at the previous position.

● Cheaper and simpler.

● Indicator display

64502 (F65P1) 74502 (F69P1)


Model 54502 (F71P1) 74502Y (F69P1Y)
64602 (F65P3) 74602 (F69P3)
3
Water Capacity 2 m /h 2 m3/h 2 m3/h 2 m3/h
Time Clock (P1) / Meter Time Clock (P1) / Meter
Running Model Time Clock
(P3) (P3)
Time Clock

Regeneration Type - Downflow Upflow Upflow


Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"M 3/4"M 3/4"F 3/4"M
Drain 3/4"M 1/2"M 1/2"M 1/2"M
Brine Tank Connector - 3/8"M 3/8"M 3/8"M
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–10" 6"–10" 6"–10"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 20 FTU < 5 FTU < 2 FTU < 2 FTU
AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz Hz 50–60 Hz 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

64504 (F63P1) 74504 (F68P1)


Model 54504 (F67P1) 74504Y (F68P1Y)
64604 (F63P3) 74604 (F68P3)
Water Capacity 4 m3/h 4 m3/h 4 m3/h 4 m3/h
Time Clock (P1) / Meter Time Clock (P1) / Meter
Running Model Time Clock
(P3) (P3)
Time Clock

Regeneration Type - Downflow Upflow Upflow


Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 1"F 1"M 1"M 1"M
Drain 1"F 1/2"M 1/2"M 1/2"M
Brine Tank Connector - 3/8"M 3/8"M 3/8"M
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–14" 6"–14" 6"–14" 6"–14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 20 FTU < 5 FTU < 2 FTU < 2 FTU
AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz Hz 50–60 Hz 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A
www.snowate.com www.snowate.com 33
Q Series

Structure & Performance Features Application


● Integrate main board and display board on one board. ● Residential softener or filter system.
● Four digital display. ● Boiler softener, lon-exchange equipment.
● With interlock connector and signal output connector.
● Parameters will be saved after power off.

55502 (F71Q1) 75502 (F69Q1) 65503 (F117Q1) 55504 (F67Q1)


Model
55602 (F71Q3) 75602 (F69Q3) 65603 (F117Q3) 55604 (F67Q3)
Water Capacity 2 m3/h 2 m3/h 2 m3/h 4 m3/h
Time Clock (Q1) / Meter Time Clock (Q1) / Meter Time Clock (Q1) / Meter Time Clock (Q1) / Meter
Running Model (Q3) (Q3) (Q3) (Q3)
Regeneration Type - Upflow Downflow -
Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"M 3/4"M 3/4"F 1"F
Drain 3/4"M 3/4"NPT 3/4"NPT 1"F
Brine Tank Connector - 3/8"M 3/8"M -
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–10" 6"–10" 6"–10"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–45 °C
Turbidity < 20 FTU < 2 FTU < 5 FTU < 20 FTU
AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz
Output Charge DC 12V/1.0A DC 12V/1.0A DC 12V/1.0A DC 12V/1.5A

75504 (F68Q1) 65505 (F116Q1) 65510 (N74Q1)


Model 55510 (N75Q1)
75604 (F68Q3) 65605 (F116Q3) 65610 (N74Q3)
Water Capacity 4 m3/h 4 m3/h 10 m3/h 10 m3 /h
Time Clock (Q1) / Meter Time Clock (Q1) / Meter Time Clock (Q1) / Meter
Running Model (Q3) (Q3) (Q3)
Time clock

Regeneration Type Upflow Downflow Downflow -


Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 1"M 1"M 2"M 2"M
Drain 3/4"NPT 3/4"NPT 1"M 2"M
Brine Tank Connector 3/8"M 3/8"M 1/2"M -
Base 2.5"-8NPSM 2.5"-8NPSM 4"-8UN 4"-8UN
Riser Pipe 1.05" OD 1.05" OD 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD
Available Tank Size 6"–14" 6"–14" 20"–30" 16"–24"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.2–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–45 °C 5–45 °C 5–50 °C 5–50 °C
Turbidity < 2 FTU < 5FTU < 5 FTU < 20 FTU
AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 24V/1.5A DC 24V/1.5A

34 www.snowate.com www.snowate.com
Floating Bed

Structure & Performance Features


● Hermetic head faces structure (F112 has piston structure)
● For F88, F98 valve, one valve on twin tanks, one in service, the other standby.
● F83, F77CS and F112CS adopt hard water for regeneration, others adopt soft water for regeneration.
● Adopt the working process: up-flow service – brine draw – brine refill – fast rinse.
● Suitable for high hardness (less than 15 mmo/L) water treatment applications.

93504 (F83A1)
Model 93606 (F98C) 93610 (F88C) 91215 (F77CS)
93604 (F83A3)
Water Capacity 4 m3/h 6 m3/h 10 m3/h 15 m3/h
Time Clock (A1) / Meter
Running Model (A3)
Meter Meter Manual Softener

Regeneration Type Upflow Upflow Upflow Upflow


Mount Type Top Mount Side Mount Side Mount Top/Side Mount
Inlet/Outlet 1"M 1"M 1.5"M 2"M
Drain 1/2"M 3/4"M 1"M 2"M
Brine Tank Connector 3/8"M 1/2"M 1/2"M 3/4"M
Base 2.5"-8NPSM - - 4"-8UN
Side mount, top and Side mount, top and bottom
Riser Pipe 1.05" OD
bottom distributor 1"M distributor 1.5"M
1.5"D-GB

Available Tank Size 10"–14" 14"–16" 20"–21" 20"–30"


Working Pressure 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–45 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 2 FTU < 2 FTU < 2 FTU < 2 FTU
AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz
-

Output Charge DC 12V/1.5A DC 24V/1.5A DC 24V/1.5A -

93520 (F95C1)
Model 91240B (F112CS) 93640B (F112C3)
93620 (F95C3)
Water Capacity 20.5 m3/h 40 m /h 3
40 m3/h
Running Model Time Clock (C1) / Meter (C3) Manual Softener Meter
Regeneration Type Upflow Upflow Upflow
Mount Type Side Mount Side Mount Side Mount
Inlet/Outlet 2"M DN65 DN65
Drain 1.5"M DN65 DN65
Brine Tank Connector 3/4"M 3/4"M 3/4"M

Base - - -
Side mount, top and bottom Side mount, top and bottom Side mount, top and bottom
Riser Pipe distributor 2"M distributor DN80 distributor DN80
Available Tank Size 20"–30" 36"–40" 36"–40"
Working Pressure 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 2 FTU < 2 FTU < 2 FTU
Input Charge AC 100V – 240V / 50–60 Hz - AC 100V – 240V / 50–60 Hz
Output Charge DC 24V/1.5A - DC 24V/1.5A

www.snowate.com www.snowate.com 35
Residential D Series

Structure & Performance Features

● LCD display, intuitional and convenient.

● Indication of long time power off, data saved after power off (saved for three days.)

● Up-flow valve can set interval backwash times F-00, which can realize several times service and one time backwash.

● Downflow or Upflow option can be set in the program, and also can mix hard water to the system if required not too soft water.

● With disinfection connector which can be connected with disinfection device to electrolyze brine during regeneration to disinfect.

● D series valve has foreground and background modes to prevent incorrect operation.

● F105 and F97 use soft water for brine refilling, both UF and DF option, have vacation mode and dry brine mode.

● F105 and F79 has the leakage protection function; F105 has the function of proportinally brine draw and brine refill based on the
percentage of real capacity

Application
● Residential Softener or the Whole House Water Softener.
● RO Pre-treatment Softener.

82602 82602
62502 (F65D1) 72502 (F69D1)
Model 52502H (F71D1) (F79A-LCD, LED are (F79B-LCD, LED are
62602 (F65D3) 72602 (F69D3)
also available.) also available.)
Water Capacity 2 m3/h 2 m3/h 2 m3/h 2 m3/h 2 m3/h
Time Clock (D1) / Time Clock (D1) /
Running Model Time Clock
Meter (D3) Meter (D3)
Meter Meter

Regeneration Type - Downflow Upflow Downflow/Upflow Downflow/Upflow


Mount Type Top Mount Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"M 3/4"F 3/4"F 3/4"M 3/4"M
Drain 3/4"M 1/2"M 1/2"M 1/2"M 1/2"M
Brine Tank
- 3/8"M 3/8"M 3/8"M 3/8"M
Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM

Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD 1.05" OD


Available Tank Size 6"–10" 6"–10" 6"–10" 6"–10" 6"–10"

Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa

Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C 5–50 °C


Turbidity < 20 FTU < 5 FTU < 2 FTU < 5 FTU < 5 FTU
AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz

Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

36 www.snowate.com www.snowate.com
Model 82602E (F105A3) 82603FD (F136BHW) 82603E (F97B3) 52504H (F67D1)

Water Capacity 2 m3/h 3 m3/h 4 m3/h 4 m3/h


Running Model Meter Meter Meter Time Clock
Regeneration Type Downflow/Upflow Downflow/Upflow Downflow/Upflow -
Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"M G1" 3/4"M 1"M
Drain 1/2"M NPT 3/4" 1/2"M 1"M
Brine Tank Connector 3/8"M 3/8"M 3/8"M -
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–12" 6"–18" 6" to 14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Downflow < 5 FTU, Downflow < 5 FTU Downflow < 5 FTU
Turbidity Upflow < 2 FTU Upflow < 2 FTU Upflow < 2 FTU
< 20 FTU
AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60 AC 100V – 240V /
Input Charge 50–60 Hz Hz Hz 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/2A DC 12V/1.5A

62504 (F63D1) 72504 (F68D1) 82604 (F82A-LCD) * 82604 (F82A-LED) *


Model
62604 (F63D3) 72604 (F68D3) 82604B (F82B-LCD) 82604B (F82B-LED)

Water Capacity 4 m3/h 4 m3/h 4 m3/h 4 m3/h


Time Clock (D1) / Meter Time Clock (D1) / Meter
Running Model (D3) (D3)
Meter Meter

Regeneration Type Downflow Upflow Downflow/Upflow Downflow/Upflow


Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 1"M 1"M 1"M 1"M
Drain 1/2"M 1/2"M 1/2"M 1/2"M
Brine Tank Connector 3/8"M 3/8"M 3/8"M 3/8"M
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6" to 18" 6" to 18" 6" to 18" 6" to 18"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C 5–50 °C
Turbidity < 5 FTU < 2 FTU < 5 FTU < 5 FTU
AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Input Charge 50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

*Note: A: No raw water passes valve when regeneration; B:With raw water passes valve when regeneration.

www.snowate.com www.snowate.com 37
Special Application Control Valves

F107&F107C
Iron-Manganese Removal Device
It is composed of aeration device and multiport control valves. The device adopts
impeller stirring plus dropping create aeration process.
And automatic air release valve constantly drain off the air and carbon dioxide in water.
Combining with automatic filter control valves, this device can help to remove the iron or manganese from the water
which has a big containing, as a pre-treatment device before industrial softening system or demineralization system.

Model F107 F107C


Water Capacity 2 m3/h 10 m3/h
Outlet Water Iron Content Iron content < 0.3 mg/L Iron content < 0.3 mg/L
Outlet Water Manganese Content < 0.1 mg/L < 0.1 mg/L
Outlet Water Turbidity < 5 mg/L < 5 mg/L
Inlet Water Iron Content Iron content < 20 mg/L Iron content < 20 mg/L
Inlet Water Manganese Content < 3 mg/L < 3 mg/L
Inlet Water Turbidity < 15 mg/L < 15 mg/L
Alkalinity < 2 mg/L < 2 mg/L
pH Value 6.8–9 6.8–9
Water Temperature 6–10 °C 6–10 °C

Control Valve for Achieving One Valve on Duplex Tanks and


Working in Series

● Patented design: one valve on duplex tanks, working in series;


● Under 0.1 MPa pressure drop, the flow rate is 4 m3/h;
● Filter + softening duplex tanks work in series system;
● Ozone + filter duplex tanks for iron and manganese removal system works in series;
● Duplex tanks softener system works in series;
● Three or more tanks can be realized in series.

Model 12504 (F142A1) 12604 (F142A3) 12504 (F142B1) 12604 (F142B3)


Water Capacity 4 m3/h 4 m3/h 4 m3/h 4 m3/h
Running Model Time Clock Meter Time Clock Meter
Downflow, Downflow, Downflow, Downflow,
Regeneration Type
brine drawing brine drawing Ozone drawing Ozone drawing
Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet G1" G1" G1" G1"
Drain NPT 3/4" NPT 3/4" NPT 3/4" NPT 3/4"
Brine Tank Connector G3/8" G3/8" G3/8" G3/8"
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1"D-GB 1"D-GB 1"D-GB 1"D-GB
Turbidity < 5 FTU < 5 FTU < 5 FTU < 5 FTU
AC 100V – 240V / AC 100V – 240V / AC 100V – 240V / AC 100V – 240V /
Transformer Input
50–60 Hz 50–60 Hz 50–60 Hz 50–60 Hz
Transformer Output DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A

38 www.snowate.com www.snowate.com
Bypass Valves Series

Model 41104 (F70A) 41102 (F70B) 41204 (F70C)


Water Capacity 4 m3/h 2 m3/h 4 m3/h
Inlet 1"M 3/4"M 1"M
Outlet 1"M 3/4"M 1"M
Valve Size 1"F 3/4"M 1"F
Inlet & Outlet Distance 50 mm 65/70 mm 50 mm
Working Pressure 0.6 MPa 0.6 MPa 0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Remark Suited for F63/F68 Valve Suited for F65/F69 Valve Suited for F63/F68/F82 Valve

Model 41202 (F70D) 41206 (F70F) 41205 (F70G)


Water Capacity 2 m3/h 6 m3/h 5 m3/h
Inlet 3/4"M 1"M NPT 3/4"M or 1"M or NPT 1"M
Outlet 3/4"M 1"M NPT 3/4"M or 1"M or NPT 1"M
Valve Size 3/4"M NPT 1" or 1"M 3/4"M or 1"M or NPT 1"M
Inlet & Outlet Distance 50 mm 50 mm 50 mm
Working Pressure 0.6 MPa 0.6 MPa 0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Suited for F63/F68/F79/F82/F105/
Remark Suited for F79 Valve Suited for F92/F97 Valve
F136 Valve

Model 41302 (F70H) 41103 (F70I) 41302Y (F70HYL)


Water Capacity 2 m3/h 3 m3/h 2 m3/h
Inlet 3/4"M 1"M 3/4"M
Outlet 3/4"M 1"M 3/4"M
Valve Size 3/4"M 1"M 3/4"M
Inlet & Outlet Distance 50 mm 50 mm 50 mm
Working Pressure 0.6 MPa 0.6 MPa 0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Remark Suited for F67N/F122 Valve Suited for F79BD Valve Suited for F105/F126 Valve

www.snowate.com www.snowate.com 39
Appendix-1

Bypass Valve
Filter Manual Softener Automatic Downflow Automatic Upflow
New Model Old Model Remark
Water Capacity Manual Automatic Downflow/Upflow Time Clock Type Meter Type Time Clock Type Meter Type 41104 F70A Suited with F63/F68
41102 F70B Suited with F65/F69
51201A/51201B/51201C 53502/52502H/53502B 63502/62502/63502B 63602/62602/63602B/ 73502/72502/73502B 73602/72602/73602B
61202/61202C 41204 F70C Suited with F63/F68/F82
51102/51202C 64502/55502 64502/65502 64602/65602 74502/74502Y 74602
1–2 m3/h 41202 F70D Suited with F79
F52/F56B/F56C/F56E/ F71B1/F71D1/F71G1/ F65B1/F65D1/F65G1 F65B3/F65D3/F65G3 F69A1/F69D1/F69G1 F69A3/F69D3 41206 F70F Suited with F97/92
F64B/F64BC
F56EC F71P/F71Q F65P1/F117Q1 65P3/F117Q3 F69P1/F69PY F69G3/F69P3 41304 F70G Suited withF63/F68/F79/F82/F105
41302 F70H Suited with F67N/F122
41103 F70I Suited with F79
53504S/53504/52504H/
63504S/63504/62504/ 63604S/63604/63604B 73504S/73504/72504 73604S/73604/72604/
51104/51204C/51240 53504B/54504/55504/ 61104/61204C
63504B/64504/65504 64604/65604 73504B/74504/74504Y 73604B/74604
56603/52504E
3–4 m3/h
Others
F67B/F67C1/F67D1/ Water Treatment
F63B1/F63C1/F63D1 F63B3/F63C3/F63G3 F68A1/F68C1/F68D1/F68G1/ F68A3/F68C3/F68D3 Product New Model Old Model
F56A/F56K/F56AC F67G1/F67P/F67Q/F67N/ F64A/F64AC Capacity
F63G1/F63P1/F116Q1 F63P3/116Q3 F68P1/F68PY F68G3/F68P3
F67K
83602 F79 2 m3/h
Downflow/Upflow 82602 F105 2 m3/h
51106 53506S/53504-A 61206 63505E/63505 63605E/63605 72505/73505 72605/73605
Softener 82603E F97A3 3 m3/h
3
5–6 m /h 83604 F82A3 4 m3/h
F56F F67B-A/F67C1-A N64F F116A1/F130A1 F116A3/F130A3 F92A1-LCD/F92A1-LED F92A-LCD/F92A-LED 93604 F83A3 4 m3/h
93606 F98C 6 m3/h
53508/53510/ 63508/63510 Control Valve for Floating 93610 F88C 10 m3/h
51208/51210 61210 63610/63610B
53510B/55510 /63510B/65510 Bed 92115 F77CS 15 m3/h
8-10 m3/h 93620 F95C3 20 m3/h
F134A/N75A1/N75B1/ F133A/N74A1 93640 F112C3 40 m3/h
F56L/N56D N64D N74A3/N74B3
N75Q N74B1/N74Q
17603 F73 3.5 m3/h
17606 F98A 6 m3/h
51215 53518/53515/53615 61215 63518/63515 63618/63615 73515 73615 One Valve on Duplex
17606T F137 6 m3/h
12–18 m3/h Tanks
17610T F135 10 m3/h
F77BS N77B1/F99B1/F99B3 F77AS N77A1/F99A1 N77A3/F99A3 F99D1 F99D3 17610 F88A 10 m3/h
Electronic Three-way
53520/53620 63520/63520T 63620/63620T 73520 73620 42020 F80 20 m3/h
3 Valve
20 m /h
F95B1/F95B3 F95A1/F111A1 F95A3/F111A3 F95D1 F95D3
On-line Sampling
44310 F84
51240B 53540B/53640B 61240B 63540B 63640B Monitory Device
30–40 m3/h
F112BS F112B1/F112B3 F112AS F112A1. F112A3 45006 F90A 6 m3/h
45012 F90B 12 m3/h
53550/53650 63550 63650 Disc Filter
3
50 m /h 45020 F90C 20 m3/h
F96B1/F96B3 F96A1 F96A3 45040 F90D 40 m3/h

40 www.snowate.com www.snowate.com 41
Appendix-2

Type New Model Old Model Inlet/Outlet Drain Base Riser Pipe Brine Line Connector Water Capacity (m3/h) Tank Size Regeneration Mode Water Pressure Turbidity

51102/51202/51202C F56E1/F56E2/F56EC 1/2"F or 3/4"F 1/2"F or 3/4"F 2.5"-8NPSM 1.05" OD 2 6"-10"

51104/51204C/51104K F56A/F56AC/F56K 1"F 1"F 2.5"-8NPSM 1.05" OD 4 6"-12"


51106/51206 F56F1/F56F2 1"F 1"F 2.5"-8NPSM 1"D-GB 6 6"-14"
1.25"D-GB 0.15–0.6 MPa
51208 F56L 1.5"M 1.5"M 4"-8UN 8 10"-24"
Manual Filter 1.66" OD <20FTU
1.5"D-GB
51110/51210 N56D1/N56D2 2"F 2"F 4"-8UN 10 10"-24"
1.9" OD
1.5"D-GB
51215 F77BS 2"M 2"M 4"-8UN 15 30" – 40"
1.9" OD
51240B F112BS DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 40 36"-48" 0.2–0.6 MPa
53502/53602/53502B/53502P/52502H/55502 F71B1/F71B3/F71G1/F71P/F71D/F71Q 3/4"M 3/4"M 2.5"-8NPSM 1.05" OD 2 6"-10"
1"F
53504/53504S/53504B/53504C/53504P/52504H/55504/56603M/52504E F67C/F67B/F67G/F67I/F67P/F67D/F67Q/F67M/F67K F67D/F67K: 1"M 2.5"-8NPSM 1.05" OD 4 6"-24" 0.15–0.6 MPa
F67M: 3/4"M - -

53506S F67B1-A 1"F 1"F 2.5"-8NPSM 1"D-GB 6 6"-24"


1.25"D-GB
53508/53608 F134A1/F134A3 1.5"M 1.5"M 4"-8UN 8 16"-24"
1.66" OD
1.5"D-GB
53510/53510B N75A/N75B 2"M 2"M 4"-8UN 10 6"-24"
1.9" OD
Automatic Filter <20FTU
1.5"D-GB
53515 F99B 2"M 2"M 4"-8UN 15 20"-30"
1.9" OD
1.5"D-GB 0.2–0.6 MPa
53518 N77B1 2"M 2"M 4"-8UN 18 24"-30"
1.9" OD
53520T/53620T F111B1/F111B3 2"M 2"M 4"-8UN 2"D-GB 20 36"-48"
53520/53620 F95B1/F95B3 2"M 2"M Side-Mounted, 2"M Top and bottom strainer connector 20 30"-36"
53540B/53640B F112B1/F112B3 DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 40 36"-48"
53550/53650 F96B1/F96B3 DN80 DN80 Side-Mounted, DN100 Top and bottom strainer connector 50 36"-48"
61202/61202C/71202C F64B/F64BC/F64C 3/4"F 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 2 6"-12"
61104/61204/61204C F64A1/F64A3/F64AC 1"F 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18"
0.15–0.6 MPa
61206 N64F 1.5"M 3/4"M 4"-8UN 1.25"D-GB 1/2"M 6 10"-28"
Manual Soften Downflow <5FTU
61210 N64D 2"M 1"M 4"-8UN 1.5"D-GB 1/2"M 10 10"-30"
61215 F77AS 2"M 2"M 4"-8UN 1.5"D-GB 3/4"M 15 30"-40"
0.2–0.6 MPa
61240B F112AS DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 3/4"M 40 48"-60"
63502/63502B/63502P/62502/65503 F65B/F65G/F65P/F65D/F117Q 3/4"F 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 2 6"-12" Downflow <5FTU
73502/73502B/73502P/72502/75502 F69A/F69G/F69P/F69D/F69Q 3/4"F 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 2 6"-12" Upflow <

63504S/63504/63504B/63504C/63504P/62504/65505/63505E F63B/F63C/F63G/F63I/F63P/F63D/F116Q/F116E 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Downflow <5FTU
0.15–0.6 MPa
73504S/73504/73504B/73504P/72504/75504 F68A/F68C/F68G/F68P/F68D/F68Q 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Upflow <2FTU
63505/63605 F116A1/F116A3 1"M 3/4"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Downflow <5FTU
73505/73605 F92A1/F92A3 1"M 3/4"M 2.5"-8NPSM 1"D-GB 3/8"M 5 10"-24" Upflow <2FTU
1.25"D-GB
63508/63608 F133A1/F133A3 1.5"M 3/4"M 4"-8UN 1/2"M 8 24"-30" Downflow <5FTU
1.66" OD
1.5"D-GB
63510/63510B N74A/N74B 2"M 1"M 4"-8UN 1/2"M 10 20"-30" Downflow <5FTU
1.9" OD
Automatic Softener 1.5"D-GB F99A Downflow Downflow<5FTU
63515/73615 F99A/F99D 2"M 1.5"M 4"-8UN 3/4"M 15 30"-40"
1.9" OD F99D Upflow Upflow<2FTU
1.5"D-GB 0.2–0.6 MPa
63518/63618 N77A1/N77A3 2"M 1.5"M 4"-8UN 3/4"M 18 30"-40" Downflow <5FTU
1.9" OD
F95A Downflow Downflow<5FTU
63520/73520 F95A/F95D 2"M 1.5"M Side-Mounted / 3/4"M 20 30"-48" F95D Upflow Upflow<2FTU
63520T F111A 2"M 1.5"M 4"-8UN 2"D-GB 3/4"M 20 36"-48" Downflow <5FTU
63540B F112A DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 3/4"M 40 48"-60" Downflow <5FTU
63550 F96A DN80 DN80 Side-Mounted, DN100 Top and bottom strainer connector 3/4"M 50 60"-72" Downflow <5FTU
82602/82602B F79A-LCD/F79B-LCD 3/4"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 2 6"-18" Down/Upflow <5FTU or <2FTU
0.15–0.6 MPa
83604/82604B F82A-LCD/F82B-LCD 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Down/Upflow <5FTU or <2FTU
17603 F73 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 3.5 12"-14" Down/Upflow <5FTU or <2FTU
17606 F98A 1"M 3/4"M Side-Mounted, 1"M Top and bottom strainer connector 1/2"M 6 20"-24" Upflow 0.15–0.6 MPa <2FTU

One Valve On Duplex Tanks 17610 F88A 1.5"M 1"M Side-Mounted, 1.5"M Top and bottom strainer connector 1/2"M 10 20"-30" Upflow <2FTU
1.5"D-GB
17610T F135A 1.5"M 3/4"M 4"-8UN 1/2"M 10 20"-30" Downflow <5FTU
1.9" OD 0.2–0.6 MPa
17606T F137 1"M 3/4"M 4"-8UN 1.5"D-GB (32 mm OD) 1/2"M 6 16"-24" Top mounted Downflow <5FTU
93504 F83A 1"'M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 10"-14" 0.15–0.6 MPa <2FTU
93606 F98C 1"M 3/4"M Side-Mounted, 1"M Top and bottom strainer connector 1/2"M 6 18"-24" <2FTU
93610 F88C 1.5"M 1"M Side-Mounted, 1.5"M Top and bottom strainer connector 1/2"M 10 20"-24" <2FTU
Control Valve for Floating Bed Floating Bed
91215 F77CS 2"M 2"M 4"-8UN 1.5"D-GB 3/4"M 15 20"-30" 0.2–0.6 MPa <2FTU
93520/93620 F95C1/F95C3 2"M 1.5"M 3/4"M 2"M 3/4"M 20 30"-36" <2FTU
91240B/93540B F112CS/F112C DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 3/4"M 40 36"-48" <2FTU
Control valve for achieving 12604 F142A 1"M NPT3/4 2.5"-8NPSM 1"D-GB 3/8"M 4 6"-18" Downflow (Brine Draw) <5FTU
one valve on duplex tanks and 0.15–0.6 MPa
working in series 12504 F142B 1"M NPT3/4 2.5"-8NPSM 1"D-GB 3/8"M 4 6"-18" Downflow (Air Draw) <5FTU

42 www.snowate.com www.snowate.com 43