Runxin Multiport Control Valves Data Sheet
Runxin Multiport Control Valves Data Sheet
MULTIPORT
Hengshui Snowate Environmental
Technology Co., Ltd.
CONTROL VALVES
2024
EDITION FOR SNOWATE CATALOG
www.snowate.com
HENGSHUI SNOWATE
ENVIRONMENTAL
TECHNOLOGY CO., LTD.
02 www.snowate.com
Contents
Multiple-Valve-In-One 04
Structure – Features 06
Working Principle 08
Applications & Industry 10
Runxin Code System 12
III Appendix 40
www.snowate.com 03
Multiple-Valve-In-One
Runxin Control valves structure is an initial international technology. It
has past International Patent Cooperation Treaty. The research report
indicates this product is creative, novel and practical in industry. It has
gotten patents in many countries such as USA, EU and so on.
04 www.snowate.com www.snowate.com
04 www.snowate.com
VS
Integrate multiple valves into one valve, which 5,7,11 and more valves pipe connections in
make the connection easier and more efficient filtering, softening and ion exchange systems
and significantly reduce leak risk . cause hard installation many potential leak points.
Fewer connections make maintenance easy and Multiple connections make the leak risk increase.
fast. Just replace the worn accessory of Runxin Besides, the repair and maintenance will spend
control valves, which can save more costs and too many labor and downtime time costs.
increase efficiency.
Just set the process in advance, it can achieve Manually operate many valves open and close will
automatic operation. spend long time and easy to have internal water
mixing.
www.snowate.com www.snowate.com 05
www.snowate.com 05
Structure – Features
A
B
Construction F F F
8 7 8 6 7 5 6 4 5 3 4 2 3 1 2
i. High Strength Synthetic material ensure the fixed disk resisting corrosion from many kinds acids
and strong alkalines except hot concentrated Nitric acid.
ii. The fixed disk is grinded to have same flatness as the ceramic moving disk to keep good and
reliable sealing. D
iii. Hermetic head faces construction has better ability to prevent damage from foreign substance
in the water.
For each softener valve, it adopts partly balance construction to prevent big torque as water
pressure increasing.
06 www.snowate.com www.snowate.com
A
B
Operate with Pressure
1
F
Runxin valve uses two high-flatness sealing disks closely located respectively. When
switch the working positions, it could operate with pressure.
While some other valves which uses soft sealing element like rubber parts, it can't operate
E
with pressure. It needs to shut off the inlet valve before switching.
C
C
No Hard Water Bypass Option
B
No Hard Water Bypass (NHWP) means the valve can internally prevent raw water from
getting into service lines during regeneration.
A
1
All Runxin valves can shut off the passage to outlet during regeneration except Model:
F79B, F82B, F92B.
www.snowate.com www.snowate.com 07
Working Principle
Using hermetic head faces theory, Runxin valve is designed to integrate multi-ports round closely to one
valve body. When the rotor rotates, some ports will be shut off and meanwhile some other ports will be
open, and thus the water will flow in and out this valve.
Construction
Runxin valve uses high-flatness moving disk and fixed disk to work as a valve. Fixed disk is fixed and moving disk is driven by
handle or motor to rotate closely over fixed disk. There are several blind via and through-holes on fixed disk and moving disk,
when moving disk stays on different positions of fixed disk, and then different flow passages will be formed:
8 7 6 5 4 3 2 1
D
6E 6D 6E 6D 6E 6D6E 6D 6D
6E 6E 6D6E 6D 6E 6E
6D
5A 5A - Blind hole
6F 6F 6F 6F 6F 6F
5B 5B - Passage to water inlet 6C 6C 6C 6F 6C 6C 6C 6F 6C 6F 6F 6F
4 3 2 1
6G 6G 6G 6G 6G
C
5C 5C - Blind Hole
F
6A 6A 6A 6A 6A 6B 6B
6B 6B 6B 6B 6B
6A 6A 6A 6A 6
6E 6D 6D - Passage to Injector
D
8 7 6 5 4 3 2 1
6F 6C 6C - Passage to Water
6G
Outlet
6A
6B
C
6B - Passage to
Bottom Strainer
4 3 2 1
08
08 www.snowate.com
www.snowate.com www.snowate.com
Controller
The controller gets signal from Timer, Meter or Water Quality Detecting Instrument, and then will initiate the motor
to drive the actuator to rotate the moving disk, and when the moving disk rotates to the correct position, another
signal will be sent to the controller through the locating device, and the controller will stop the moving disk until
it finishes this step; When next new signal is received by the controller, the controller will drive the moving disk to
rotate to a new position and so on until all steps are finished and cycled.
Water passes this part. No water passes this part. (Same as below)
6E 6E6D 6D6E
6D 6D 6E 6E
6D 6E
6E6D 6D6E
6D 6D 6E 6E
6D 6E6D 6D6E 6D 6E 6E
6D 6E6D 6D
6C 6F 6C 6C 6C 6F 6C 6F 6F
6F 6C 6F 6C 6C
6C 6F 6C 6F 6F 6C 6F 6C 6C 6F 6C 6F 6F 6C 6C 6C
6G 6G 6G 6G 6G
6B 6B 6B 6B 6B 6B 6B 6B
6B 6B 6A
6B 6B 6A 6B6B 6A 6A 6A
6A 6A 6A 6A 6A 6A 6B 6B
6A 6B 6A 6B 6A 6A 6A
www.snowate.com www.snowate.com
www.snowate.com 09
09
Applications & Industry
Runxin control valves (filter valves and softening valves) are core component during filtering and softening
system. They are widely used in various fields to guarantee efficient and easier water treatment.
Industrial Fields
Water filtering and softening for boiler, heat exchange equipment,
cooling system and RO system.
Agriculture
Water filtering and softening for crops and flowers irrigation,
livestock drinking, vegetables and fruits washing.
Residential
Water filtering and softening for drinking, bathing, cooking, as
well as for electric boilers, water heaters, underfloor heating and
other installations.
Commercial
Pre-filtering and softening of RO system for drinking and
domestic use. It can be used for swimming pool filtering.
10 www.snowate.com www.snowate.com
Process Water Treatment
Deaeration
Deaeration for boiler water to prevent piping, water tank, and
other metal components from oxygen corrosion.
Defluoridation
Remove excess fluorine in underground water to protect people
from fluorosis.
www.snowate.com www.snowate.com 11
Runxin Code System
53610
5 3 6 10
Application Control Method Handle Type Or Maximum Flow Rate
Regeneration Type
WIFI Control
Examples
For 53610 control valve
5 means filter valve, 3 means LED display automatic control, 6 means meter type, 10 means water treatment capacity is 10 m3/h
That is,
53610 means meter type automatic filter valve with water treatment capacity of 10 m3/h.
12
12 www.snowate.com
www.snowate.com www.snowate.com
Special Application Control Valves
For code beginning with 1 are control valves for special applications, and for code
beginning with 4 are spare parts. The meaning of the first two digits refers to the
following chart.
Code 11 13 15 17 18
Special Control valve for Control valve Control valve for Single valve with Single valve with
Applications fluoride removal for deaerator mixed bed system double tanks triple tanks
Code 41 42 43 44 45 46 47 48
Special Bypass Tee Brine Online Disk Controller Disinfection Salt Shortage
Valve Valve Valve Monitoring Filter Device Alarm Device
Applications Device
53610
www.snowate.com www.snowate.com
www.snowate.com 13
13
Manual Filter Control Valves
Applications
● Household Filter System (F56A/F56E/F56F).
● Activated carbon filter or sand filter system for RO pretreatment system.
● Swimming Pool Filter System (N56D/F77BS).
● N56D/F77BS can be used for Iron/Manganese Removal system if side
mount adapter is installed upside down.
Popular Models
Handle Material Metal (E1) / Plastic (E2) Plastic handwheel Metal (A1) / Plastic (A2)
Mount Type Top Mount Top Mount, Side Control Top Mount
Inlet/Outlet 1/2"F (-1) or 3/4"F (-2) 1/2"F (-1) or 3/4"F (-2) 1"F
Drain 1/2"F (-1) or 3/4"F (-2) 1/2"F (-1) or 3/4"F (-2) 1"F
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
14 www.snowate.com www.snowate.com
51106 (F56F1)
Model 51204C (F56AC) 51204K (F56K)
51206 (F56F2)
Mount Type Top Mount, Side control Top Mount Top Mount
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
51110 (N56D1)
Model 51208 (F56L) 51215 (F77BS) 51240B (F112BS)
51210 (N56D2)
Handle Material Plastic handwheel Metal (D1) / Plastic (D2) Plastic Handwheel Plastic handwheel
Mount Type Top Mount Top/Side Mount Top/Side Mount Side Mount
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
www.snowate.com www.snowate.com 15
Automatic Filter Control Valves
Applications
● Residential Filter System (F71/F67).
● Activated carbon filter or sand filter system for RO pretreatment system.
Popular Models
53502 (F71B1)
Model 53502B (F71G1) 56603 (F67M)
53602 (F71B3)
Water Capacity 2 m3/h 2 m3/h 3 m3/h
Running Model Time Clock (B1) / Meter (B3) Time Clock Meter
Mount Type Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"M 3/4"M 3/4"M
Drain 3/4"M 3/4"M 3/4"M
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–10" 6"–10"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 20 FTU < 20 FTU < 20 FTU
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Transformer Output DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A
16 www.snowate.com www.snowate.com
53504 (F67C1) 53504S (F67B1)
Model 53504B (F67G1) 53504C (F67I1)
53604 (F67C3) 53604S (F67B3)
Mount Type Top Mount Top Mount Top Mount Top Mount
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Input Charge Hz 50–60 Hz Hz Hz
Transformer Output DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A
Running Model Time Clock (B1) / Meter (B3) Time Clock (B1) / Meter (B3) Time Clock
Mount Type Top/Side Mount Top/Side Mount Top/Side Mount
Inlet/Outlet 2"M 2"M 2"M
Drain 2"M 2"M 2"M
Base 4"-8UN 4"-8UN 4"-8UN
Riser Pipe 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD 1.5"D-GB or 1.9" OD
Available Tank Size 6"–21" 20"–30" 30"–36"
Working Pressure 0.15–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 20 FTU < 20 FTU < 20 FTU
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Transformer Output DC 24V/1.5A DC 24V/1.5A DC 24V/1.5A
Base - 4"-8UN - -
Side mount top and Side mount, top and Side mount, top and
Riser Pipe bottom distributor 2"M
2"D-GB
bottom distributor DN80 bottom distributor DN100
Available Tank Size 30"–36" 30"–36" 36"–48" 36"–48"
Working Pressure 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Media Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon Sand / Activated Carbon
AC 100V – 240V / 50–60 AC 100V – 240V / AC 100V – 240V / 50–60 AC 100V – 240V / 50–60
Input Charge Hz 50–60 Hz Hz Hz
Transformer Output DC 24V/1.5A DC 24V/1.5A DC 24V/4.0A DC 24V/4.0A
18 www.snowate.com www.snowate.com
Manual Softening Control Valves
Applications
● Residential Softener System(F64A/F64AC/F64B/F64BC).
● Softener system for RO.
● Boiler softener system; ion exchange units.
Popular Models
www.snowate.com www.snowate.com 19
61104 (F64A1)
Model 61204C (F64AC) 61206 (N64F)
61204 (F64A2)
Handle material Metal (A1) / Plastic (A2) Plastic handwheel Plastic handwheel
Mount Type Top Mount Top Mount, Side control Top Mount
20 www.snowate.com www.snowate.com
Automatic Softening Control Valves
● LED display, long time power off indication and data will be saved for three days after power off.
● With signal output connector, remote handling connector which can receive passive signal.
● With interlock connector which can realize service simultaneously and regeneration one by one.
● N77, F95, F111 and F99 adopt ball valve for brine drawing and refill.
● Time clock regeneration option: by days or by hours; Meter valve regeneration option: Meter Delayed (A-01),
Meter Immediate (A-02), Intelligent Meter Delayed (A-03), intelligent Meter Immediate (A-04).
● Up-flow control valve can set interval backwash times F-00, which can realize several times service and one time backwash.
● N77, F95 and F111 have two valve cores, one is for controlling inlet water and brine drawing, another is for outlet water.
Applications
Notes
● The model with a “S" means the valve with manual operation function.
www.snowate.com www.snowate.com 21
63502 (F65B1) 63502B (F65G1) 73502 (F69A1)
Model
63602 (F65B3) 63602B (F65G3) 73602 (F69A3)
Water Capacity 2 m3/h 2 m3/h 2 m3/h
Running Model Time Clock (B1) / Meter (B3) Time Clock (G1) / Meter (G3) Time Clock (A1) / Meter (A3)
Regeneration Type Downflow Downflow Upflow
Mount Type Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"F 3/4"F 3/4"F
Drain 1/2"M 1/2"M 1/2"M
Brine Tank
3/8"M 3/8"M 3/8"M
Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–10" 6"–10"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–45 °C 5–45 °C 5–45 °C
Turbidity < 5 FTU < 5 FTU < 2 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A
Running Model Time Clock (G1) / Meter (G3) Time Clock (A1) / Meter (A3) Time Clock (C1) / Meter (C3)
Regeneration Type Upflow Downflow Downflow
Mount Type Top Mount Top Mount Top Mount
Inlet/Outlet 3/4"F 3/4"F 1"M
Drain 1/2"M 3/4"M 1/2"M
Brine Tank
3/8"M 3/8"M 3/8"M
Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–10" 6"–10" 6"–14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 2 FTU < 5 FTU < 5 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A
22 www.snowate.com www.snowate.com
63504B (F63G1) 63504C (F63I1) 63504S (F63B1)
Model
63604B (F63G3) 63604C (F63I3) 63604S (F63B3)
Water Capacity 4 m3/h 4 m3/h 4 m3/h
Running Model Time Clock (G1) / Meter (G3) Time Clock (I1) / Meter (I3) Time Clock (B1)/ Meter (B3)
Regeneration Type Downflow Downflow Downflow
Mount Type Top Mount Side Mount Top Mount
Inlet/Outlet 1"M 1"M 1"M
Drain 1/2"M 1/2"M 1/2"M
Brine Tank
3/8"M 3/8"M 3/8"M
Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–14" 6"–14" 6"–14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 5 FTU < 5 FTU < 5 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A
Running Model Time Clock (C1) / Meter (C3) Time Clock (G1) / Meter (G3) Time Clock (A1) / Meter (A3)
Regeneration Type Upflow Upflow Upflow
Mount Type Top Mount Top Mount Top Mount with handwheel
Inlet/Outlet 1"M 1"M 1"M
Drain 1/2"M 1/2"M 1/2"M
Brine Tank
3/8"M 3/8"M 3/8"M
Connector
Base 2.5"-8NPSM 2.5"-8NPSM 2.5"-8NPSM
Riser Pipe 1.05" OD 1.05" OD 1.05" OD
Available Tank Size 6"–14" 6"–14" 6"–14"
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 2 FTU < 2 FTU < 2 FTU
Input Charge AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz AC 100V – 240V / 50–60 Hz
Output Charge DC 12V/1.5A DC 12V/1.5A DC 12V/1.5A
www.snowate.com www.snowate.com 23
63505 (F116A1) 73505 (F92A1)
Model F116E3 F130A3
63605 (F116A3) 73605 (F92A3)
Water Capacity 4 m3/h 5 m3/h 5 m3/h 4.7 m3/h
Running Model Time Clock (A1) / Meter (A3) Meter Meter Time Clock (A1) / Meter (A3)
Regeneration Type Downflow Downflow Downflow Upflow
Mount Type Top Mount Top Mount Top Mount Top Mount
Inlet/Outlet 1"M 1"M 1"M 1"M
Drain 3/4"M 3/4"M NPT 3/4" 3/4"M
24 www.snowate.com www.snowate.com
63515 (F99A1) 73515 (F99D1) 63518 (N77A1) 63520 (F95A1)
Model
63615 (F99A3) 73615 (F99D3) 63618 (N77A3) 63620 (F95A3)
Water Capacity 15 m3/h 15 m3/h 18 m3/h 21.6 m3/h
Time Clock (A1) / Meter Time Clock (D1) / Meter Time Clock (A1) / Meter Time Clock (A1) / Meter
Running Model (A3) (D3) (A3) (A3)
Regeneration Type Downflow Upflow Downflow Downflow
Mount Type Top/Side Mount Top/Side Mount Top/Side Mount Side Mount
Inlet/Outlet 2"M 2"M 2"M 2"M
Drain 1.5"M 1.5"M 1.5"M 1.5"M
www.snowate.com www.snowate.com 25
Continuous Water Supply Control Valves
This system contains one control valve and two tanks, it can achieve
downflow or upflow regeneration through switch program. Besides, it
adopts top or side mount method according to different output and tank
structure.
This structure can achieve max. output 3.5 m3/h, 6 m3/h, 10 m3/h.
Technical Performance
Item Requirements
Notes
● When the turbidity exceeds the working condition, a filter should be installed on the inlet of control valves.
● When the water hardness exceeds the working condition, the hardness of treated water can not meet the
needed requirements (for example 0.03 mmol/L for boil water), you should adopt secondary softening.
26 www.snowate.com www.snowate.com
17603 17603 (F73) 17606 (F98A) 17606T (F137) 17610 (F88A) 17610T (F135A)
www.snowate.com www.snowate.com 27
One in service and one standby fixed bed system
17610/17606
Tank U2 in service and Tank U1 in standby Tank U1 in service and Tank U2 in Brine & Slow
Rinse (Upflow regeneration)
Tank U2 in Service and Tank U1 in fast rinse Tank U1 in service and Tank U2 in brine infill
Tank U1 in Service and Tank U2 in Backwash Tank U1 in Service and Tank U2 in Standby
2828www.snowate.com
www.snowate.com www.snowate.com
Control valve for floating bed system
93610/93606
Tank U1 in service and Tank U2 in standby Tank U2 in service and Tank U1 in Brine & Slow Rinse
Tank U1 in Service and Tank U2 in fast rinse Tank U2 in service and Tank U1 in brine infill
Tank U2 in Service and Tank U1 in Setting Bed Tank U2 in Service and Tank U1 in Standby
www.snowate.com www.snowate.com2929
www.snowate.com
One in Service One Standby – Two Valve and Two Tank
F92A3 F92A3
5–6 m3/h
● Suitable for 5-6 m3/h Continuous Water Supplying
● Two F92A3/F130A3 and DN25 Three-way Electronic Bal
Valve (Four Core Plug)
10–20 m3/h
● Suitable for 10-20 m3/h Continuous Water Supplying
● Two N74A3/F99A3/N77A3/F95A3/F111A3 and F80
● Two valves are interlocked as one system, and set the system to
A-02 and b-01; Connect the signal output connector with the
control wire of F80.
● When the flow of working valve reduces to 0, the control valve
regenerates F80 switches by the signal outlet connector controlling,
the other valve turns to service.
● If the other valve is in regeneration, because of the function of interlock,
the working valve still in service.
1# Valve
Main Control Board NC
Blue COM
Black
1#
NO F80 Valve
Main Control Board
Interlock Power cord
2# Valve
Cablel
Main Control Board NC
Blue COM
Black
2# -24DC
NO
+24VDC
40–50 m3/h
● Suitable for 40–50 m3/h Continuous Water Supplying
● Two F112A3/F96A3 and Two DN25 Electronic Ball Valves
● Two valves are connected to signal line of one in service and one
standby system (interlock wire), and set the system to C-02 (One
in Service One Standby System).
● Ordinary F112A3/F96A3 needs to replace brine draw copper tube
and install DN25 ball valve with it.
● Continuous water supplying, one valve in service, the other valve
standby.
30
30 www.snowate.com
www.snowate.com www.snowate.com
Two in Service One Standby
● One valve controls three tanks, two tanks supply with softened water in series, the other tank standby to achieve water supply continuously.
● When service finishes, the first grade in series tums to regenerate, the second grade tums to the first grade and supplies with softened water
together with the standby tank as the second grade in series, which greatly improves the resin efficiency, saves water and salt.
● Regeneration tank keeps standby after switch and starts fast rinse before service.
● Raw water or softened water for regeneration is optional by changing the moving disk.
● Remove one tank to make the system as one in service one standby system.
● There is always two tanks in service in series which could treat the raw water with high
hardness. It has backwash function, which could be used in high turbidity application
which floating bed system can' t be used.
● Suitable for treat high hardness water and continuous water supplying application Right Tank
Middle tank
left tank
18604A (F118A)
Model 18601B (F120B)
18604B (F118B)
Water Capacity 4 m3/h 1.5 m3/h
Note: F118A raw water regeneration mode; F118B soft water regeneration mode.
www.snowate.com www.snowate.com
www.snowate.com 31
31
Softener Flow Chart
Inlet Inlet Inlet
Outlet Outlet Outlet
Softening
Inlet Inlet Inlet
Outlet Outlet Outlet
Left tank + middle tank in serial service, Middle tank + right tank in serial service, Right tank + left tank in serial service,
right tank regeneration and standby left tank regeneration and standby middle tank regeneration and standby
Regeneration It takes left tank and middle tank in serial service and right tank regeneration as sample.
Left tank + middle tank in serial service, Left tank + middle tank in serial service, Left tank + middle tank in serial service,
right tank backwash right tank upflow brine draw right tank downflow brine draw
32 www.snowate.com www.snowate.com
P Series
● Hermetic head faces structure, no hard water bypass during regeneration cycle.
● When power on, program run one cycle then locate at the previous position.
● Indicator display
34 www.snowate.com www.snowate.com
Floating Bed
93504 (F83A1)
Model 93606 (F98C) 93610 (F88C) 91215 (F77CS)
93604 (F83A3)
Water Capacity 4 m3/h 6 m3/h 10 m3/h 15 m3/h
Time Clock (A1) / Meter
Running Model (A3)
Meter Meter Manual Softener
93520 (F95C1)
Model 91240B (F112CS) 93640B (F112C3)
93620 (F95C3)
Water Capacity 20.5 m3/h 40 m /h 3
40 m3/h
Running Model Time Clock (C1) / Meter (C3) Manual Softener Meter
Regeneration Type Upflow Upflow Upflow
Mount Type Side Mount Side Mount Side Mount
Inlet/Outlet 2"M DN65 DN65
Drain 1.5"M DN65 DN65
Brine Tank Connector 3/4"M 3/4"M 3/4"M
Base - - -
Side mount, top and bottom Side mount, top and bottom Side mount, top and bottom
Riser Pipe distributor 2"M distributor DN80 distributor DN80
Available Tank Size 20"–30" 36"–40" 36"–40"
Working Pressure 0.2–0.6 MPa 0.2–0.6 MPa 0.2–0.6 MPa
Water Temperature 5–50 °C 5–50 °C 5–50 °C
Turbidity < 2 FTU < 2 FTU < 2 FTU
Input Charge AC 100V – 240V / 50–60 Hz - AC 100V – 240V / 50–60 Hz
Output Charge DC 24V/1.5A - DC 24V/1.5A
www.snowate.com www.snowate.com 35
Residential D Series
● Indication of long time power off, data saved after power off (saved for three days.)
● Up-flow valve can set interval backwash times F-00, which can realize several times service and one time backwash.
● Downflow or Upflow option can be set in the program, and also can mix hard water to the system if required not too soft water.
● With disinfection connector which can be connected with disinfection device to electrolyze brine during regeneration to disinfect.
● D series valve has foreground and background modes to prevent incorrect operation.
● F105 and F97 use soft water for brine refilling, both UF and DF option, have vacation mode and dry brine mode.
● F105 and F79 has the leakage protection function; F105 has the function of proportinally brine draw and brine refill based on the
percentage of real capacity
Application
● Residential Softener or the Whole House Water Softener.
● RO Pre-treatment Softener.
82602 82602
62502 (F65D1) 72502 (F69D1)
Model 52502H (F71D1) (F79A-LCD, LED are (F79B-LCD, LED are
62602 (F65D3) 72602 (F69D3)
also available.) also available.)
Water Capacity 2 m3/h 2 m3/h 2 m3/h 2 m3/h 2 m3/h
Time Clock (D1) / Time Clock (D1) /
Running Model Time Clock
Meter (D3) Meter (D3)
Meter Meter
Working Pressure 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa 0.15–0.6 MPa
36 www.snowate.com www.snowate.com
Model 82602E (F105A3) 82603FD (F136BHW) 82603E (F97B3) 52504H (F67D1)
*Note: A: No raw water passes valve when regeneration; B:With raw water passes valve when regeneration.
www.snowate.com www.snowate.com 37
Special Application Control Valves
F107&F107C
Iron-Manganese Removal Device
It is composed of aeration device and multiport control valves. The device adopts
impeller stirring plus dropping create aeration process.
And automatic air release valve constantly drain off the air and carbon dioxide in water.
Combining with automatic filter control valves, this device can help to remove the iron or manganese from the water
which has a big containing, as a pre-treatment device before industrial softening system or demineralization system.
38 www.snowate.com www.snowate.com
Bypass Valves Series
www.snowate.com www.snowate.com 39
Appendix-1
Bypass Valve
Filter Manual Softener Automatic Downflow Automatic Upflow
New Model Old Model Remark
Water Capacity Manual Automatic Downflow/Upflow Time Clock Type Meter Type Time Clock Type Meter Type 41104 F70A Suited with F63/F68
41102 F70B Suited with F65/F69
51201A/51201B/51201C 53502/52502H/53502B 63502/62502/63502B 63602/62602/63602B/ 73502/72502/73502B 73602/72602/73602B
61202/61202C 41204 F70C Suited with F63/F68/F82
51102/51202C 64502/55502 64502/65502 64602/65602 74502/74502Y 74602
1–2 m3/h 41202 F70D Suited with F79
F52/F56B/F56C/F56E/ F71B1/F71D1/F71G1/ F65B1/F65D1/F65G1 F65B3/F65D3/F65G3 F69A1/F69D1/F69G1 F69A3/F69D3 41206 F70F Suited with F97/92
F64B/F64BC
F56EC F71P/F71Q F65P1/F117Q1 65P3/F117Q3 F69P1/F69PY F69G3/F69P3 41304 F70G Suited withF63/F68/F79/F82/F105
41302 F70H Suited with F67N/F122
41103 F70I Suited with F79
53504S/53504/52504H/
63504S/63504/62504/ 63604S/63604/63604B 73504S/73504/72504 73604S/73604/72604/
51104/51204C/51240 53504B/54504/55504/ 61104/61204C
63504B/64504/65504 64604/65604 73504B/74504/74504Y 73604B/74604
56603/52504E
3–4 m3/h
Others
F67B/F67C1/F67D1/ Water Treatment
F63B1/F63C1/F63D1 F63B3/F63C3/F63G3 F68A1/F68C1/F68D1/F68G1/ F68A3/F68C3/F68D3 Product New Model Old Model
F56A/F56K/F56AC F67G1/F67P/F67Q/F67N/ F64A/F64AC Capacity
F63G1/F63P1/F116Q1 F63P3/116Q3 F68P1/F68PY F68G3/F68P3
F67K
83602 F79 2 m3/h
Downflow/Upflow 82602 F105 2 m3/h
51106 53506S/53504-A 61206 63505E/63505 63605E/63605 72505/73505 72605/73605
Softener 82603E F97A3 3 m3/h
3
5–6 m /h 83604 F82A3 4 m3/h
F56F F67B-A/F67C1-A N64F F116A1/F130A1 F116A3/F130A3 F92A1-LCD/F92A1-LED F92A-LCD/F92A-LED 93604 F83A3 4 m3/h
93606 F98C 6 m3/h
53508/53510/ 63508/63510 Control Valve for Floating 93610 F88C 10 m3/h
51208/51210 61210 63610/63610B
53510B/55510 /63510B/65510 Bed 92115 F77CS 15 m3/h
8-10 m3/h 93620 F95C3 20 m3/h
F134A/N75A1/N75B1/ F133A/N74A1 93640 F112C3 40 m3/h
F56L/N56D N64D N74A3/N74B3
N75Q N74B1/N74Q
17603 F73 3.5 m3/h
17606 F98A 6 m3/h
51215 53518/53515/53615 61215 63518/63515 63618/63615 73515 73615 One Valve on Duplex
17606T F137 6 m3/h
12–18 m3/h Tanks
17610T F135 10 m3/h
F77BS N77B1/F99B1/F99B3 F77AS N77A1/F99A1 N77A3/F99A3 F99D1 F99D3 17610 F88A 10 m3/h
Electronic Three-way
53520/53620 63520/63520T 63620/63620T 73520 73620 42020 F80 20 m3/h
3 Valve
20 m /h
F95B1/F95B3 F95A1/F111A1 F95A3/F111A3 F95D1 F95D3
On-line Sampling
44310 F84
51240B 53540B/53640B 61240B 63540B 63640B Monitory Device
30–40 m3/h
F112BS F112B1/F112B3 F112AS F112A1. F112A3 45006 F90A 6 m3/h
45012 F90B 12 m3/h
53550/53650 63550 63650 Disc Filter
3
50 m /h 45020 F90C 20 m3/h
F96B1/F96B3 F96A1 F96A3 45040 F90D 40 m3/h
40 www.snowate.com www.snowate.com 41
Appendix-2
Type New Model Old Model Inlet/Outlet Drain Base Riser Pipe Brine Line Connector Water Capacity (m3/h) Tank Size Regeneration Mode Water Pressure Turbidity
63504S/63504/63504B/63504C/63504P/62504/65505/63505E F63B/F63C/F63G/F63I/F63P/F63D/F116Q/F116E 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Downflow <5FTU
0.15–0.6 MPa
73504S/73504/73504B/73504P/72504/75504 F68A/F68C/F68G/F68P/F68D/F68Q 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Upflow <2FTU
63505/63605 F116A1/F116A3 1"M 3/4"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Downflow <5FTU
73505/73605 F92A1/F92A3 1"M 3/4"M 2.5"-8NPSM 1"D-GB 3/8"M 5 10"-24" Upflow <2FTU
1.25"D-GB
63508/63608 F133A1/F133A3 1.5"M 3/4"M 4"-8UN 1/2"M 8 24"-30" Downflow <5FTU
1.66" OD
1.5"D-GB
63510/63510B N74A/N74B 2"M 1"M 4"-8UN 1/2"M 10 20"-30" Downflow <5FTU
1.9" OD
Automatic Softener 1.5"D-GB F99A Downflow Downflow<5FTU
63515/73615 F99A/F99D 2"M 1.5"M 4"-8UN 3/4"M 15 30"-40"
1.9" OD F99D Upflow Upflow<2FTU
1.5"D-GB 0.2–0.6 MPa
63518/63618 N77A1/N77A3 2"M 1.5"M 4"-8UN 3/4"M 18 30"-40" Downflow <5FTU
1.9" OD
F95A Downflow Downflow<5FTU
63520/73520 F95A/F95D 2"M 1.5"M Side-Mounted / 3/4"M 20 30"-48" F95D Upflow Upflow<2FTU
63520T F111A 2"M 1.5"M 4"-8UN 2"D-GB 3/4"M 20 36"-48" Downflow <5FTU
63540B F112A DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 3/4"M 40 48"-60" Downflow <5FTU
63550 F96A DN80 DN80 Side-Mounted, DN100 Top and bottom strainer connector 3/4"M 50 60"-72" Downflow <5FTU
82602/82602B F79A-LCD/F79B-LCD 3/4"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 2 6"-18" Down/Upflow <5FTU or <2FTU
0.15–0.6 MPa
83604/82604B F82A-LCD/F82B-LCD 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 6"-18" Down/Upflow <5FTU or <2FTU
17603 F73 1"M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 3.5 12"-14" Down/Upflow <5FTU or <2FTU
17606 F98A 1"M 3/4"M Side-Mounted, 1"M Top and bottom strainer connector 1/2"M 6 20"-24" Upflow 0.15–0.6 MPa <2FTU
One Valve On Duplex Tanks 17610 F88A 1.5"M 1"M Side-Mounted, 1.5"M Top and bottom strainer connector 1/2"M 10 20"-30" Upflow <2FTU
1.5"D-GB
17610T F135A 1.5"M 3/4"M 4"-8UN 1/2"M 10 20"-30" Downflow <5FTU
1.9" OD 0.2–0.6 MPa
17606T F137 1"M 3/4"M 4"-8UN 1.5"D-GB (32 mm OD) 1/2"M 6 16"-24" Top mounted Downflow <5FTU
93504 F83A 1"'M 1/2"M 2.5"-8NPSM 1.05" OD 3/8"M 4 10"-14" 0.15–0.6 MPa <2FTU
93606 F98C 1"M 3/4"M Side-Mounted, 1"M Top and bottom strainer connector 1/2"M 6 18"-24" <2FTU
93610 F88C 1.5"M 1"M Side-Mounted, 1.5"M Top and bottom strainer connector 1/2"M 10 20"-24" <2FTU
Control Valve for Floating Bed Floating Bed
91215 F77CS 2"M 2"M 4"-8UN 1.5"D-GB 3/4"M 15 20"-30" 0.2–0.6 MPa <2FTU
93520/93620 F95C1/F95C3 2"M 1.5"M 3/4"M 2"M 3/4"M 20 30"-36" <2FTU
91240B/93540B F112CS/F112C DN65 DN65 Side-Mounted, DN80 Top and bottom strainer connector 3/4"M 40 36"-48" <2FTU
Control valve for achieving 12604 F142A 1"M NPT3/4 2.5"-8NPSM 1"D-GB 3/8"M 4 6"-18" Downflow (Brine Draw) <5FTU
one valve on duplex tanks and 0.15–0.6 MPa
working in series 12504 F142B 1"M NPT3/4 2.5"-8NPSM 1"D-GB 3/8"M 4 6"-18" Downflow (Air Draw) <5FTU
42 www.snowate.com www.snowate.com 43