Grid Summary
Grid Summary
Report Documents
Project: Experiencia 2(1) Study Case: Study Case Study Time: 23-11-2024 14:16:52
Table of Contents
Grid Summary...............................................................................................................................................................................
3
1 Grid Summary............................................................................................................................................................................
3
2 Grid.............................................................................................................................................................................................
4
2.1 Overview.............................................................................................................................................................................
4
2.2 Power Summary.................................................................................................................................................................
4
2.3 Additional Power Summary..............................................................................................................................................
5
2.4 Maximum/Minimum Summary........................................................................................................................................ 5
2.5 Interchange Power Flow Summary.................................................................................................................................. 5
Grid Summary
1 Grid Summary
Number of Grids: 1
Grid
2 Grid
2.1 Overview
Number of Voltage Number of
No. of Substations No. of Busbars No. of Terminals No. of Lines
Levels Connected Grids
1 0 0 7 15 21
0 0 0 0 0 0
No. of Other
No. of PV Systems No. of Loads No. of SVS No. of Shunts/Filters No. of Isolated Areas
Elements
0 14 0 7 1 7
No. of Unsupplied
Isolated Areas
Generators, Nominal Active Power Generators, Nominal Reactive Power Generators, Nominal Apparent Power
MW Mvar MVA
0,0 0,0
Loads, Nominal Active Power Loads, Nominal Reactive Power Loads, Nominal Apparent Power
MW Mvar MVA
Loads, difference between nominal and Loads, difference between nominal and
actual active power actual reactive power
MW Mvar
-0,0 -0,0
Motor Loads, Active Power Motor Loads, Reactive Power Motor Loads, Apparent Power
MW Mvar MVA
0,0 -0,2
0,0 0,0
Losses, Active Power (no load) Losses, Reactive Power (no load)
MW Mvar
0,0 -0,3
External Networks, Active Power External Networks, Reactive Power External Networks, Apparent Power
MW Mvar MVA
0,0 -0,2
Generators, Power Factor Loads, Power Factor Motor Loads, Power Factor
- - -
1,000 0,991
Maximum Loading
%
58,7