MTC Vicat Week 33

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

IS:269

KALBURGI CEMENT PVT. LTD.


Corporate Office: 8-2-626, Reliance Majestic Building, Road No. 10, Banjara Hills,
Hyderabad – 500 034, A.P., India. Ph.: +91 40 3006999; Fax: +91 40 30006955
Works :Chatrasala (V), Kharchkhed (Post) - 585 320, Chincholi (Tq.), Gulbarga Dist.
CM/L :4578077

TEST CERTIFICATE (OPC - 53 Grade)


Product : VICAT - OPTIMATE Week No: 33

Despatched From : 12/8/2024 TO 16/8/2024

A. PHYSICAL REQUIREMENTS
RESULTS As per IS 269 – 2015
(as per IS:4031)

Fineness:
a. Specific Surface (m2/kg) 282 Not less than 225

b. Normal Consistency (%) 29.50 --------

Soundness:

a. By Le-Chatelier Method (mm) 1.25 Not more than 10 mm

b. By Autoclave (%) 0.04 Not more than 0.8 %

Setting Time:

a. Initial Setting Time (minutes) 150 Not less than 30

b. Final Setting Time (minutes) 250 Not more than 600

Compressive Strength (MPa)

a. 3 days 34.71 Not less than 27

b. 7 days Awaited Not less than 37

c. 28 days Awaited Not less than 53

B. CHEMICAL REQUIREMENTS
(as per IS:4032)

a. Lime Saturation Factor 0.89 0.80 – 1.02

b. Aluminum Modules 1.31 Not less than 0.66

c. Insoluble Residue (%) 1.59 Not more than 5.0

d. Magnesia (%) 1.01 Not more than 6.0

e. Sulphuric Anhydride (%) 2.50 Not more than 3.5

f. Loss on Ignition (%) 1.84 Not more than 4.0

g. Chlorides (%) 0.01 Not more than 0.1

h. Alkali Content (%) 0.53 Not more than 0.6


0
i. Temperature During Testing C 27.40 27 ± 2

j. Specific Gravity 3.15 3.15

Asst Manager-QC HOD - QC